Search NASA⌕ Search

SEARCH · Search NASA

Results for “insulation damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of space station multilayer insulation damage due to hypervelocity space debris impact

Four main tasks were accomplished. The first three tasks were related to the goal of measuring the degradation of the insulating capabilities of Space Station multilayer insulation (MLI) due to simulated space debris impacts at hypervelocities. The last task was associated with critically reviewing a Boeing document on the fracture characteristics of the Space Station pressure wall when subjected to a simulated hypervelocity space debris impact. In Task 1, a thermal test procedure for impact damaged MLI specimens was written. In Task 2, damaged MLI specimens were prepared. In Task 3, a computer program was written to simulate MLI thermal tests. In Task 4, the author reviewed a Boeing document describing hypervelocity impact testing on biaxially stressed plates.

Rule, William Keith↗

A Method to have Multi-Layer Thermal Insulation Provide Damage Detection

Design and testing of a multi-layer thermal insulation system that also provides debris and micrometeorite damage detection is presented. One layer of the insulation is designed as an array of passive open-circuit electrically conductive spiral trace sensors. The sensors are a new class of sensors that are electrically open-circuits that have no electrical connections thereby eliminating one cause of failure to circuits. The sensors are powered using external oscillating magnetic fields. Once electrically active, they produce their own harmonic magnetic fields. The responding field frequency changes if any sensor is damaged. When the sensors are used together in close proximity, the inductive coupling between sensors provides a means of telemetry. The spiral trace design using reflective electrically conductive material provides sufficient area coverage for the sensor array to serves as a layer of thermal insulation. The other insulation layers are designed to allow the sensor s magnetic field to permeate the insulation layers while having total reflective surface area to reduce thermal energy transfer. Results of characterizing individual sensors and the sensor array s response to punctures are presented. Results of hypervelocity impact testing using projectiles of 1-3.6 millimeter diameter having speeds ranging from 6.7-7.1 kilometers per second are also presented.

Woodward, Stanley E.↗

Sunspot: A program to model the behavior of hypervelocity impact damaged multilayer insulation in the Sunspot thermal vacuum chamber of Marshall Space Flight Center

The development of a computer program to predict the degradation of the insulating capabilities of the multilayer insulation (MLI) blanket of Space Station Freedom due to a hypervelocity impact with a space debris particle is described. A finite difference scheme is used for the calculations. The computer program was written in Microsoft BASIC. Also described is a test program that was undertaken to validate the numerical model. Twelve MLI specimens were impacted at hypervelocities with simulated debris particles using a light gas gun at Marshall Space Flight Center. The impact-damaged MLI specimens were then tested for insulating capability in the space environment of the Sunspot thermal vacuum chamber at MSFC. Two undamaged MLI specimens were also tested for comparison with the test results of the damaged specimens. The numerical model was found to adequately predict behavior of the MLI specimens in the Sunspot chamber. A parameter, called diameter ratio, was developed to relate the nominal MLI impact damage to the apparent (for thermal analysis purposes) impact damage based on the hypervelocity impact conditions of a specimen.

Rule, W. K.↗

Evaluating Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381) with Ultrasound

A series of experiments to investigate the use of ultrasound for measuring wire insulation have been conducted. Initial laboratory tests were performed on MIL-W-81381/7,/12, and /21 aviation wire, a wire that has polyimide (Kapton Registered Trademark) layers for insulation. Samples of this wiring were exposed to 370C temperatures for different periods of time to induce a range of thermal damage. For each exposure, 12 samples of each gauge (12, 16, and 20 gauges) were processed. The velocity of the lowest order axisymmetric ultrasonic guided mode, a mode that is sensitive to the geometry and stiffness of the wire conductor and insulation, was measured. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 +/- 78 m/s. After exposure to the high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 +/- 20 m/s after 100 hours exposure. Similar behavior was measured for the 16 gauge MIL-W-81381/21 wire and 12 gauge MIL-W-81381/12 wire which had baseline values of 3225 +/- 22 m/s and 3403 +/- 33 m/s respectively, and reached asymptotic values of 3668 +/- 19 m/s, and 3679 +/- 42 m/s respectively. These measured velocity changes represent changes of 19, 14, and 8 percent respectively for the 20, 16, and 12 gauge wires. Finally, some results for a wire with an ethylene tetrafluoroethylene insulation are reported. Qualitatively similar behaviors are noted ultrasonically.

Madaras, Eric I.↗

Comparison of Ultrasound with Tensile Testing of Thermally Damaged Polyimide Insulated Wiring (MIL-W-81381)

Ultrasonic measurements were performed on MIL-W-81381/7, /12, and /21 wire, a polyimide (Kapton) insulated wire. The phase velocity for the 20-gauge MIL-W-81381/7 wire had a baseline value of 3023 plus or minus 78 m/s. After exposure to high temperatures, the wire's phase velocity rapidly increased, and reached an asymptotic value of 3598 plus or minus 20 m/s after 100 hours exposure. Similar responses were measured in other gauges. The baseline measurements of Young's moduli resulted in values of 5636 plus or minus 486, 7714 plus or minus 505, and 8767 plus or minus 292 KSI for the 20 ga, 16 ga, and 12 ga. wires respectively.

Madaras, Eric I.↗

Interpolation/extrapolation technique with application to hypervelocity impact of space debris

A new technique for the interpolation/extrapolation of engineering data is described. The technique easily allows for the incorporation of additional independent variables, and the most suitable data in the data base is automatically used for each prediction. The technique provides diagnostics for assessing the reliability of the prediction. Two sets of predictions made for known 5-degree-of-freedom, 15-parameter functions using the new technique produced an average coefficient of determination of 0.949. Here, the technique is applied to the prediction of damage to the Space Station from hypervelocity impact of space debris. A new set of impact data is presented for this purpose. Reasonable predictions for bumper damage were obtained, but predictions of pressure wall and multilayer insulation damage were poor.

Rule, William K.↗

The mechanical properties of polyimide films after exposure to high pH

Wiring failures linked to insulation damage have drawn much attention in the aerospace industry and concerns have developed regarding the stability and safety of polyimide insulated electrical wire. Several polyimides were selected for evaluation for resistance to degradation by various aqueous alkaline solutions. The polyimides under evaluation include commercially available films such as Kapton (tk), Apical (tk), LaRC(tk)-TPI, and Upilex(tk)R and S, as well as a number of experimental films prepared by NASA Langley. Thermally imidized films were studied for their retention of mechanical properties after exposure to high pH solutions under stressed conditions.

Croall, Catharine I.↗

The mechanical stability of polyimide films at high pH

Polyimide insulated electrical wire has been widely used in the aerospace industry in commercial, military, and to a lesser degree, general aviation aircraft since the early 1970s. Wiring failures linked to insulation damage have drawn much attention in the media and concerns have developed regarding the long term stability and safety of polyimide insulated electrical wire. The mechanical durability and chemical stability of polyimide insulated wire are affected by hydrolysis, notch propagation, wet and dry arc tracking, topcoat flaking, and degradation due to high pH fluids. Several polyimides were selected for evaluation for resistance to degradation by various aqueous alkaline solutions. The polyimides under evaluation include commercially available films such as KAPTON (tradename), APICAL (tradename), LARC-TPI, and UPILEX (tradename) R and S, as well as a number of experimental films prepared at NASA-Langley. Material properties investigated include viscosity, solubility, moisture absorption, glass transition temperature, dielectric constant, and mechanical properties before and after exposure to various conditions.

Croall, Catharine I.↗

Magnet-wire wrapping tool for integrated circuits

Wire-dispensing tool which resembles mechanical pencil is used to wrap magnet wire around integrated circuit terminals uniformly and securely without damaging insulative coating on wire. Tool is hand-held and easily manipulated to execute wire wrapping movements.

Takahashi, T. H.↗

Effects of thermal and electrical stressing on the breakdown behavior of space wiring

Several failures in the electrical wiring systems of many aircraft and space vehicles have been attributed to arc tracking and damaged insulation. In some instances, these failures proved to be very costly as they have led to the loss of many aircraft and imperilment of space missions. Efforts are currently underway to develop lightweight, reliable, and arc track resistant wiring for aerospace applications. In this work, six wiring constructions were evaluated in terms of their breakdown behavior as a function of temperature. These hybrid constructions employed insulation consisting of Kapton, Teflon, and cross-linked Tefzel. The properties investigated included the 400 Hz AC dielectric strength at ambient and 200 C, and the lifetime at high temperature with an applied bias of 40, 60, and 80% of breakdown voltage level. The results obtained are discussed, and conclusions are made concerning the suitability of the wiring constructions investigated for aerospace applications.

Hammoud, Ahmad↗

Next Generation Life Support: High Performance EVA Glove

The objectives of the High Performance EVA Glove task are to develop advanced EVA gloves for future human space exploration missions and generate corresponding standards by which progress may be quantitatively assessed. New technologies and manufacturing techniques will be incorporated into the new gloves to address finger and hand mobility, injury reduction and durability in nonpristine environments. Three prototypes will be developed, each focusing on different technological advances. A robotic assist glove will integrate a powered grasping system into the current EVA glove design to reduce astronaut hand fatigue and hand injuries. A mechanical counter pressure (MCP) glove will be developed to further explore the potential of MCP technology and assess its capability for countering the effects of vacuum or low pressure environments on the body by using compression fabrics or materials to apply the necessary pressure. A gas pressurized glove, incorporating new technologies, will be the most flight-like of the three prototypes. Advancements include the development and integration of aerogel insulation, damage sensing components, dust-repellant coatings, and dust tolerant bearings.

Walsh, Sarah K.↗

Electron-beam induced damage in thin insulating films on compound semiconductors

Phosphorus rich plasma enhanced chemical vapor deposition (PECVD) of silicon nitride and silicon dioxide films on n-type indium phosphide (InP) substrates were exposed to electron-beam irradiation in the 5 to 40 keV range for the purpose of characterizing the damage induced in the dielectric. The electron-beam exposure was on the range of 10(exp -7) to 10(exp -3) C/sq cm. The damage to the devices was characterized by capacitance-voltage (C-V) measurements of the metal insulator semiconductor (MIS) capacitors. These results were compared to results obtained for radiation damage of thermal silicon dioxide on silicon (Si) MOS capacitors with similar exposures. The radiation induced damage in the PECVD silicon nitride films on InP was successfully annealed out in an hydrogen/nitrogen (H2/N2) ambient at 400 C for 15 min. The PECVD silicon dioxide films on InP had the least radiation damage, while the thermal silicon dioxide films on Si had the most radiation damage.

Pantic, Dragan M.↗

Repairing Damaged Power-Cable Insulation

Simple method saves time, money, and material. In new method cable remains in place while new insulation is applied to damaged portion. Method results in new terminations with safety factor equal to that of any portion of cable.

Baker, G. E.↗

Track damage and erosion of insulators by ion-induced electronic processes

Track damage and the associated ejection of atoms and molecules from insulators, which occur as a result of ion-induced electronic excitation, are of interest both in their own right and because of the mechanisms through which the energy in the excited electrons is transformed into atomic motion. In this paper an overview is given of the phenomena that are observed. We show that there is a remarkable similarity between the damage profile along the ion's track in the solid and the yield of ejected atoms at the energy that corresponds to each point on the track. It is also seen that the density of extended defects (or, correspondingly, the ejected particle yield) appears to have a 'universal' form that is weakly dependent on the type of material. In the model presented this is a consequence of the inner-shell ionization of light elements in the solid by the incident ion; the resulting Auger decay produces an intense ionization spike that locally triggers the track formation/erosion process. This model allows the estimation of erosion yields/damage profiles for different ions and materials.

Tombrello, T. A.↗

Testing and numerical modeling of hypervelocity impact damaged Space Station multilayer insulation

Results are presented of experiments measuring the degradation of the insulating capabilities of the multilayer insulation (MLI) of the Space Station Freedom, when subjected to hypervelocity impact damage. A simple numerical model was developed for use in an engineering design environment for quick assessment of thermal effect of the impact. The model was validated using results from thermal vacuum tests on MLI with simulated damage. The numerical model results agreed with experimental data.

Rule, William K.↗

Plasma Interactions with a Negative Biased Electrodynamic Tether

The ProSEDS conductive tether design incorporates two distinct types of tethers from a plasma interaction viewpoint. The 200 m closest to the Delta 11 spacecraft is insulated from the plasma, and the remaining 5000 m is semi-bare. This latter portion is semi-bare because it has a conductive coating applied to the wires to permit electron collection while also regulating the overall tether temperature. Because the tether possesses these two distinct types of tethers, a transition point exists between the two types that form a triple point with the space plasma. Insulated tethers can suffer from a second plasma interaction if the insulation is weakened or breached, such as by pinholes caused by small particle debris strikes. Because electrodynamic tethers are typically long, they have a high probability of such impacts. These impacting particles may not be of sufficient size to severe the tether, but they can easily be of sufficient size to damage the tether insulation. Samples of both the ProSEDS tether transition region and the insulated tether section (with various degrees of pinhole damage) were placed into the MSFC plasma chamber and biased to typical ProSEDS open circuit tether potentials (-500 V to -1600 V). The results of the testing showed that the transition region of the tether (i.e. the triple point) arced and burned the tether in two at -900 V, and the damaged insulated sections arced and burned in two between -1000 V and -1600, depending on the pinhole damage geometry. tether design and make the tether ready for flight. To reduce the pinhole arcing risk, ProSEDS mission operations were changed to eliminate the negative potential on the tether. The results of the testing campaign and the design changes implemented to ensure a successful flight will be described.

Vaughn, Jason A.↗