Search NASA⌕ Search

SEARCH · Search NASA

Results for “insulation installation quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DOE Residential Energy Code Field Study - Pennsylvania

This project consisted of three distinct phases – all focused on residential one- and two-family dwellings and townhouses. Phase 1 included a baseline field study with inspections and performance testing to assess construction practices with respect to the energy code. PNNL used the data to perform EUI and savings potential analyses. Phase 2 consisted of training, education, and outreach to building industry professionals with content based on the findings from Phase 1. Phase 3 was a post-program field study using the same methodology as Phase 1 and was intended to measure the impact of Phase 2. During Phase 1 of the project, PSD collected data from 171 job sites across eastern Pennsylvania, a territory bounded by PECO, PPL, and Met-Ed electric distribution territories, to reach the required 63 “home equivalents” deemed necessary by PNNL for a representative sample. Based on subsequent analysis, four key items were identified as having significant savings potential from improvement in compliance, including duct leakage, above-grade wall insulation (specifically insulation installation quality), foundation insulation, and high-efficacy lighting. About half the total savings potential is from duct leakage, so that was the primary focus. The goal of Phase 2 was to improve upon these key compliance weaknesses through an intensive training, education, and outreach program. PSD dubbed this effort the Penn Energy Codes Program. For Phase 3, PSD obtained a new sample plan from PNNL, obtained permit data from sample municipalities, and made substitutions where necessary. PSD field staff visited 165 job sites to collect the required 504 key observations. PSD submitted all data collection sheets to PNNL for their analysis to determine if there was a measurable change due to Phase 2 activities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Building Energy Code Field Study

This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data set to represent baseline construction practices across U.S. states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Air Leakage Evaluation: A Modular Case Study

The purpose of this case study is to compare the air leakage rates of modular and site-built multifamily dwelling units. The methods, materials, and equipment were observed to be very similar in the modular and site-constructed units in this case study. The installation quality of building envelope measures such as insulation and air barrier appeared to be better for modular construction, because they were installed in a controlled, factory setting. Through field observations, we identified cosmetic damage to the envelope of modular units following transport to the building site, but with no resulting significant air leakage pathways. However, we did see air leakage pathways resulting from field modifications to the envelope of modular units to accommodate structural and mechanical connections. We found that the extensive use of through-wall HVAC systems, combined with the transport, placement, and rework of modular units may compromise the high-quality envelope installation and airtightness observed in the factory without careful planning and/or design. Opportunities for improvement identified from the tested modular dwelling units include minimizing and optimally locating penetrations, pre-cutting and detailing penetrations at the factory where possible, properly sealing field modifications, and using split HVAC systems in place of through-wall packaged systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Watt Count System

The Watt Count System combines aerospace and computer technology, an engineering systems design approach and the environmental control expertise of a group of engineers who worked on Apollo. First step of the system is a computerized energy consumption analysis based on plans for a new home. Company calculates heating and cooling loads and customizes the most energy efficient system for the particular structure analyzed. A quality control engineer assures that insulation and ducting are installed to specifications. Analysis and design techniques are so accurate that company is able to give homeowner a two-year guarantee that the home's energy consumption will not exceed the kilowatt hour level determined by the computer in step one. In an annual energy performance comparison, a Watt Count home used 45 percent less energy than a conventionally equipped home.

Source record↗

Cryogenic Testing of Different Seam Concepts for Multilayer Insulation Systems

Recent testing in a cylindrical, comparative cryostat at the Cryogenics Test Laboratory has focused on various seam concepts for multilayer insulation systems. Three main types of seams were investigated: straight overlap, fold-over, and roll wrapped. Each blanket was comprised of 40 layer pairs of reflector and spacer materials. The total thickness was approximately 12.5-mm, giving an average layer density of 32 layers per centimeter. The blankets were tested at high vacuum, soft vacuum, and no vacuum using liquid nitrogen to maintain the cold boundary temperature at 77 K. Test results show that all three seam concepts are all close in thermal performance; however the fold-over method provides the lowest heat flux. For the first series of tests, seams were located 120 degrees around the circumference of the cryostat from the previous seam. This technique appears to have lessened the degradation of the blanket due to the seams. In a follow-on test, a 20 layer blanket was tested in a roll wrapped configuration and then cut down the side of the cylinder, taped together, and re-tested. This test result shows the thermal performance impact of having the seams all in one location versus having the seams clocked around the vessel. This experimental investigation indicates that the method of joining the seams in multilayer insulation systems is not as critical as the quality of the installation process.

Johnson, Wesley L.↗

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)↗

Manufacture and Quality Control of Insert Coil with Real ITER TF Conductor

JAEA successfully completed the manufacture of the toroidal field (TF) insert coil (TFIC) for a performance test of the ITER TF conductor in the final design in cooperation with Hitachi, Ltd. The TFIC is a single-layer 8.875-turn solenoid coil with 1.44-m diameter. This will be tested for 68-kA current application in a 13-T external magnetic field. TFIC was manufactured in the following order: winding of the TF conductor, lead bending, fabrication of the electrical termination, heat treatment, turn insulation, installation of the coil into the support mandrel structure, vacuum pressure impregnation (VPI), structure assembly, and instrumentation. Here in this presentation, manufacture process and quality control status for the TFIC manufacturing are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prototype solar heating and hot water systems

Alternative approaches to solar heating and hot water system configurations were studied, parametrizing the number and location of the dampers, the number and location of the fans, the interface locations with the furnace, the size and type of subsystems, and operating modes. A two-pass air-heating collector was selected based on efficiency and ease of installation. Also, an energy transport module was designed to compactly contain all the mechanical and electrical control components. System performance calculations were carried out over a heating season for the tentative site location at Tunkhnana, Pa. Results illustrate the effect of collector size, storage capacity, and use of a reflector. Factors which affected system performance include site location, insulative quality of the house, and of the system components. A preliminary system performance specification is given.

Source record↗

Determination and Assessment of Optimum Internal Thermal Insulation for Masonry Walls in Historic Multifamily Buildings

A large portion of existing building stock is comprised of load-bearing masonry buildings, particularly in the Midwest and on the East Coast, though such buildings are distributed across the US. Most of them have uninsulated walls or suffer from insufficient thermal insulation materials. These buildings are inseparable parts of the cultural, social, and economic characteristics of their cities. Due to heritage and preservation concerns, zoning, and space restrictions, they cannot be retrofitted with exterior insulation. Interior insulation must therefore be considered as an alternative. Lack of insulation directly results in energy waste as well as heat loss and gain. Furthermore, it adversely affects heating, ventilation, and air conditioning (HVAC) loads, equipment sizing, indoor air quality, and thermal comfort for residents. The objective of this study is to simulate and evaluate the effects of various internal thermal insulation materials and strategies on mass masonry load-bearing walls in multifamily buildings with attention to various variables and parameters. It not only addresses the energy performance and cost savings associated with an interior insulation retrofit, but also outlines other variables and parameters that are factors in the selection of optimum insulation material, including installations costs, payback periods, useful internal space loss, and options for the depth of the interior insulation retrofit. In conclusion, the audience for this paper is diverse: homeowners, contractors and remodelers, architects and designers, engineers, housing and preservation authorities, and more can benefit from understanding the results outlined in this study.

42 ENGINEERING↗

Akiachak Energy Efficiency Retrofit Project

The goal of the project is to reduce the overall energy use of the Akiachak Native Community (ANC) by implementing energy efficiency measures in five high-use Tribal buildings. This project will have the following outcomes: Projected annual energy savings of $17,369; projected annual reduction in fuel oil #1 of 1,200 gallons and electricity of 17,751 kWh; annual reduction in carbon dioxide emissions of approximately 60,340 pounds/year. ANC will install energy efficiency measures in the Laundry, Tribal Indian Reorganization Act (IRA) Office, Clinic, Daycare, and Police Station. ANC obtained energy audits on these buildings in 2018, and this project will implement high-payback recommendations such as replacing lighting with LEDs, installing setback thermostats and occupancy sensors, replacing furnaces with more efficient models, replacing the circulation pumps with variable speed ones, air tightening, and adding insulation. Buildings will see energy cost reductions from 15% to 40%. These retrofits will help build ANC’s long-term vision for sustainable energy usage and address the first goal of the Tribal IRA Council’s Energy Efficiency and Conservation Strategy, to “create and maintain functionally appropriate, sustainable, accessible, high quality tribal infrastructure and facilities.” ANC intends to replicate this project by using the resulting energy savings to address audit recommendations in other buildings as well as to demonstrate the value of energy efficiency to community members. Other outcomes will include an increase in community resiliency, reduced dependence on outside shipments of fuel oil, training for maintenance staff, and no-touch control of building appliances to reduce transmission of diseases such as COVID-19.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Wire Crimp Termination Verification Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

Perey, Daniel F.↗

Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

BSC TO5 Task 2.5 Field Testing of an Un-vented Roof with Fibrous Insulation and Tiles - Winter Park, FL 32789 Field test data available for wood moisture contents, temperature, and relative humidity. Un-vented roofs (aka cathedral-ized attics) are an established presence in Florida residential building markets. These roofs are built with a layer of spray polyurethane foam (SPF) on the underside of the roof deck. Such a roof configuration positions the heating, ventilating, and air-conditioning equipment and ductwork within the conditioned space and improves airtight-ness in practice (by shifting the air barrier from the ceiling to the roofline). However, SPF is more expensive than fibrous insulation. Some builders have also become wary of using SPF because of liability concerns about indoor air quality and off-gassing. Unfortunately, un-vented roofs that use only air-permeable fibrous insulation (cellulose or fiberglass) have been demonstrated to be at risk of moisture issues in climate zone 2A because condensation and moisture accumulation occur at the ridge. This report describes research about a test implementation of an un-vented tile roof assembly in a hot-humid climate (Orlando, Florida; climate zone 2A); the roof was insulated with air-permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous work, the U.S. Department of Energy's Building America research team Building Science Corporation theorized that installation of diffusion vents might allow for the wintertime release of moisture to safe levels. Diffusion vents are open slots at the roof's highest points (the ridge and hips) that are covered with a water-resistant but vapor-open (500+ perm) air barrier membrane. The test home is a two-story slab-on-grade structure (3,600 ft2 ); the roof was insulated with a prototype insulation system (called boxed netting), which allows full depth insulation (i.e., it is not limited by the depth of the truss top chord). As a control comparison, one part of the roof was constructed as a typical un-vented roof (with a self-adhered membrane at the ridge). Ideally, failure would occur in the control roof and the experimental (diffusion vent) roofs would show sufficient drying to avoid failure. No intentional space conditioning was provided in the un-vented attic so worst-case humidity buildup conditions could be observed.

air leakage↗

Report on Initial Sodium Testing on the Thermal Hydraulic Experimental Test Article (THETA) (Fiscal Year 2024 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as to acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal thermal hydraulic conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. In fiscal year 2023, thermal stratification tests were completed with the primary system online, while the secondary system was being constructed [1]. These tests had shown that the core barrel and intermediate heat exchanger (IHX) outlet required increased thermal insulation. The THETA primary system was removed from METL, cleaned, thermal insulators installed, and then inserted into METL Test Vessel 4. At the time of this writing the THETA primary and secondary system are operational. During this fiscal year 100+ hours of testing was completed to characterize thermal hydraulic phenomena associated with steady state and transient conditions in a pool type liquid metal cooled reactor. A majority of the testing campaign was completed to satisfy the experimental data acquisition requirements for the GAIN Voucher with Oklo, CRADA 2021-21121. THETA is still operational at the time of this publication and future testing is planned for fiscal year 2025. Work is underway to publish existing and future data to an online database to facilitate collaboration with SFR engineers looking to validate their systems code or computational fluid dynamics models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PV backsheets survey protocol: A framework for geo-spatial field surveys for bulk material characterization and reliability analysis applied across 41 PV systems

As widespread adoption of photovoltaic (PV) technologies continues, understanding the lifetime of modules is paramount to the viability of the industry as an environmentally conscious alternative to traditional energy generation. Although power degradation can affect the total energy production of a module over its lifetime, module safety failures necessitate the removal of a module leading to a loss of not only the particular asset, but the earning potential of the device. Therefore, it is critical to ensure that the components that provide essential safety functions for PV module operate for their entire rated lifetime. PV backsheets provide necessary electrical insulation to the completed device and failure of this component is cause for a immediate removal of the module. Degradation of the PV module backsheet has led to module safety failures in large-scale installations, costing millions of dollars in damages and lost potential revenue. The spatio-temporal degradation of fielded PV modules is important to study in order to identify which modules within installations are experiencing the greatest exposure conditions and in turn have the highest chance of failure. This paper describes a comprehensive field survey protocol developed for monitoring PV module backsheet performance using solely non-destructive methods in commercial PV fields. The protocol establishes a field naming convention, sampling method, data handling requirements, and measurement procedures. By ensuring consistent data collection practices, the field survey protocol enables research groups to obtain data of uniform quality on backsheet performance over multiple years and locations. In this study, the developed protocol was implemented at forty-one PV sites. Eight different types of airside layer backsheet materials including poly(vinylidene fluoride) (PVDF), acrylic PVDF, poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), fluoroethylene vinyl ether (FEVE), polyethylene naphthalate (PEN), and glass were identified using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The field survey results show that the spatial distribution of degradation indicators are non-uniform within a particular module, individual site, and across site locations. The degradation of PV modules increased in severity for modules mounted at the edge of rows (across a field) and near the junction box (within a module). This study demonstrates the sensitivity of material performance to exposure length across different materials and climates.

14 SOLAR ENERGY↗

Provisions for nonintrusive flow-evaluation tools in the National Transonic Facility

The national transonic facility fan driven, closed circuit, continuous flow, pressurized wind tunnel is examined. The test section is 2.500 m x 2.500 m and 7.620 m long with a slotted wall configuration. There are six slots each in the top and bottom walls and two slots per sidewall. To maintain good flow quality and aerodynamic efficiency over the wide range of test capabilities the test section geometry is variable. The position of the test section and bottom walls, the reentry flaps at the rear of the test section slots, and the step height for reentering slot flow are remotely controlled. The test gas may be dry air or nitrogen, which for the elevated temperature (340 K) mode of operation the test medium is normally air, and heat removal is by a water cooled heat exchanger (cooling coil) located at the upstream end of the settling chamber. For the cryogenic mode of operation, heat removal is by evaporation of liquid nitrogen, which is sprayed into the circuit upstream of the fan. By utilizing liquid nitrogen as a coolant, the tunnel test temperature range is variable from 340 to 78 K. When nitrogen is injected into the circuit, venting must occur to maintain a constant pressure. Thermal insulation is installed internal to the pressure shell to minimize energy consumption.

Fuller, D. E.↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗