Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The silicon vidicon: Integration, storage and slow scan capability - Experimental observation of a secondary mode of operation.

Description of the performance of the silicon diode array vidicon - an imaging sensor which possesses wide spectral response, high quantum efficiency, and linear response. These characteristics, in addition to its inherent ruggedness, simplicity, and long-term stability and operating life make this device potentially of great usefulness for ground-base and spaceborne planetary and stellar imaging applications. However, integration and charged storage for periods greater than approximately five seconds are not possible at room temperature because of diode saturation from dark current buildup. Since dark current can be reduced by cooling, measurements were made in the range from -65 to 25 C. Results are presented on the extension of integration, storage, and slow scan capabilities achievable by cooling. Integration times in excess of 20 minutes were achieved at the lowest temperatures. The measured results are compared with results obtained with other types of sensors and the advantages of the silicon diode array vidicon for imaging applications are discussed.

Ando, K. J.↗

Integral storage-bulb and microwave cavity for masers

Mechanically-stable integral storage-bulb/microwave cavity made out of single piece of fused quartz improves frequency stability. Single-piece construction eliminates joints, making cavity dimensionally and hence frequency-stable. Fused quartz is used because of its low thermal expansion coefficient.

Reinhardt, V. S.↗

Zero-Boiloff Cryogenic Storage Cryocooler Integration Test

Developments in NASA Glenn Research Center's Centaur work have led to an exciting new cryogenic storage concept being considered for future NASA space missions. With long-duration cryogenic storage, propellants will boil off because of the environmental heating of the tank. To accommodate these losses, extra propellant is required along with larger propellant tanks. Analyses of space transportation concepts show that spacetransfer cryogenic stages with the zero boiloff (ZBO) cryogenic storage concept reduce the stage mass for missions longer than approximately 45 days in low Earth orbit. The ZBO system consists of an active cryocooling system using a cryocooler in addition to traditional passive thermal insulation. Engineers at Glenn analyzed, designed, built, and bench tested a heat exchanger and integration hardware for a large-scale ZBO demonstration for the NASA Marshall Space Flight Center. The heat exchanger, which transfers the heat that enters the tank from the fluid to the cryocooler, must limit the temperature difference across it to limit the cryocooler size and power requirements. With a low temperature difference, the system efficiency is improved. For that temperature difference to be reduced, the thermal conductivity must be as high as possible at liquid hydrogen temperatures, around 25 K (-248 C). In addition, it is important for the heat exchanger to be welded to a stainless steel flange and have enough strength to accommodate piping stress. High-conductivity copper was selected and fabricated, then integrated with the stainless steel piping tee as shown in the cutaway representation. Literature showed that this conductivity might range from 2 to 100 W/cm/K but that is was likely to be around 13 W/cm/K. Unexpectedly, this conductivity was measured to be 23 W/cm/K, which limited the temperature increase along the heat exchanger to just 2 K. This limited temperature increase, compared with the predicted difference of 3.5 K, improves the overall system efficiency by 7.4 percent and limits the expected integration losses to a projected 4 percent with a flight design for liquid hydrogen storage. These results improve the cryocooler integration concept by allowing the cryocooler to operate at a lower input power, or by potentially permitting a smaller cryocooler to be selected.

Plachta, David W.↗

Long term cryogenic storage system integration

Investigations have revealed significant increases in performance when a reliquefier and solar shield in conjunction with a zero-gravity vapor vent system are utilized. Application of a reliquefier and solar shield in long term deep space missions may effect a 60% reduction in propellant loss, compared to that associated with the vapor vent system only. Significant improvements in storage system performance are possible for low earth orbit applicatons; for the typical system that was evaluated, system performance gains were realized for mission durations exceeding 7 days. Spherical solar shields are generally not competitive for low earth orbit applications.

Stonemetz, R. E.↗

Habituation and adaptation of the vestibuloocular reflex: a model of differential control by the vestibulocerebellum

We habituated the dominant time constant of the horizontal vestibuloocular reflex (VOR) of rhesus and cynomolgus monkeys by repeated testing with steps of velocity about a vertical axis and adapted the gain of the VOR by altering visual input with magnifying and reducing lenses. After baseline values were established, the nodulus and ventral uvula of the vestibulocerebellum were ablated in two monkeys, and the effects of nodulouvulectomy and flocculectomy on VOR gain adaptation and habituation were compared. The VOR time constant decreased with repeated testing, rapidly at first and more slowly thereafter. The gain of the VOR was unaffected. Massed trials were more effective than distributed trials in producing habituation. Regardless of the schedule of testing, the VOR time constant never fell below the time constant of the semicircular canals (approximately 5 s). This finding indicates that only the slow component of the vestibular response, the component produced by velocity storage, was habituated. In agreement with this, the time constant of optokinetic after-nystagmus (OKAN) was habituated concurrently with the VOR. Average values for VOR habituation were obtained on a per session basis for six animals. The VOR gain was adapted by natural head movements in partially habituated monkeys while they wore x 2.2 magnifying or x 0.5 reducing lenses. Adaptation occurred rapidly and reached about +/- 30%, similar to values obtained using forced rotation. VOR gain adaptation did not cause additional habituation of the time constant. When the VOR gain was reduced in animals with a long VOR time constant, there were overshoots in eye velocity that peaked at about 6-8 s after the onset or end of constant-velocity rotation. These overshoots occurred at times when the velocity storage integrator would have been maximally activated by semicircular canal input. Since the activity generated in the canals is not altered by visual adaptation, this finding indicates that the gain element that controls rapid changes in eye velocity in the VOR is separate from that which couples afferent input to velocity storage. Nodulouvulectomy caused a prompt and permanent loss of habituation, returning VOR time constants to initial values. VOR gain adaptation, which is lost after flocculectomy, was unaffected by nodulouvulectomy. Flocculectomy did not alter habituation of the VOR or of OKAN. Using a simplified model of the VOR, the decrease in the duration of vestibular nystagmus due to habituation was related to a decrement in the dominant time constant of the velocity storage integrator (1/h0).(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Large Scale Production of Densified Hydrogen Using Integrated Refrigeration and Storage

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage (IRAS) technology at NASA Kennedy Space Center led to the production of large quantities of solid densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. System energy balances and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing (up to 1 K), and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. Twenty silicon diode temperature sensors were recorded over approximately one month for testing at two different fill levels (33 67). The phenomenon, observed at both two fill levels, is described and presented detailed and explained herein., and The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Notardonato, William U.↗

Resolution of sensory ambiguities for gaze stabilization requires a second neural integrator

The ability to simultaneously move in the world and maintain stable visual perception depends critically on the contribution of vestibulo-ocular reflexes (VORs) to gaze stabilization. It is traditionally believed that semicircular canal signals drive compensatory responses to rotational head disturbances (rotational VOR), whereas otolith signals compensate for translational movements [translational VOR (TVOR)]. However, a sensory ambiguity exists because otolith afferents are activated similarly during head translations and reorientations relative to gravity (i.e., tilts). Extra-otolith cues are, therefore, necessary to ensure that dynamic head tilts do not elicit a TVOR. To investigate how extra-otolith signals contribute, we characterized the temporal and viewing distance-dependent properties of a TVOR elicited in the absence of a lateral acceleration stimulus to the otoliths during combined translational/rotational motion. We show that, in addition to otolith signals, angular head position signals derived by integrating sensory canal information drive the TVOR. A physiological basis for these results is proposed in a model with two distinct integration steps. Upstream of the well known oculomotor velocity-to-position neural integrator, the model incorporates a separate integration element that could represent the "velocity storage integrator," whose functional role in the oculomotor system has so far remained controversial. We propose that a key functional purpose of the velocity storage network is to temporally integrate semicircular canal signals, so that they may be used to extract translation information from ambiguous otolith afferent signals in the natural and functionally relevant bandwidth of head movements.

Non-NASA Center↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Mass storage system reference model, Version 4

The high-level abstractions that underlie modern storage systems are identified. The information to generate the model was collected from major practitioners who have built and operated large storage facilities, and represents a distillation of the wisdom they have acquired over the years. The model provides a common terminology and set of concepts to allow existing systems to be examined and new systems to be discussed and built. It is intended that the model and the interfaces identified from it will allow and encourage vendors to develop mutually-compatible storage components that can be combined to form integrated storage systems and services. The reference model presents an abstract view of the concepts and organization of storage systems. From this abstraction will come the identification of the interfaces and modules that will be used in IEEE storage system standards. The model is not yet suitable as a standard; it does not contain implementation decisions, such as how abstract objects should be broken up into software modules or how software modules should be mapped to hosts; it does not give policy specifications, such as when files should be migrated; does not describe how the abstract objects should be used or connected; and does not refer to specific hardware components. In particular, it does not fully specify the interfaces.

Coleman, Sam↗

High temperature thermal energy storage, including a discussion of TES integrated into power plants

Storage temperatures of 260 C and above are considered. Basic considerations concerning energy thermal storage are discussed, taking into account general aspects of thermal energy storage, thermal energy storage integrated into power plants, thermal storage techniques and technical considerations, and economic considerations. A description of system concepts is provided, giving attention to a survey of proposed concepts, storage in unpressurized fluids, water storage in pressurized containers, the use of an underground lined cavern for water storage, a submerged thin insulated steel shell under the ocean containing pressurized water, gas passage through solid blocks, a rock bed with liquid heat transport fluid, hollow steel ingots, heat storage in concrete or sand, sand in a fluidized bed, sand poured over pipes, a thermal energy storage heat exchanger, pipes or spheres filled with phase change materials (PCM), macroencapsulated PCM with heat pipe concept for transport fluid, solid PCM removed from heat transfer pipes by moving scrapers, and the direct contact between PCM and transport fluid.

Turner, R. H.↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Transient Modeling of Large Scale Integrated Refrigeration and Storage Systems

Recently, next generation techniques and designs were demonstrated using Integrated Refrigeration and Storage (IRAS) for large scale storage of liquid hydrogen at NASA Kennedy Space Center (KSC) in Florida. Zero boil-off, densification, and in-situ liquefaction of hydrogen were achieved at various fill levels inside a custom-built 125,000 liter, horizontal-cylindrical IRAS tank, validating the applicability of the concept for large scale cryo-fluid storage architectures. This paper will discuss a number of transient physics models developed to predict the bulk behavior of large IRAS systems, and the comparison of those models to data gathered during the KSC test campaign. In an attempt to extent their usefulness to future IRAS designs, these models were agnostic with respect to stored fluid, tank size and geometry. Behavior during densification testing was examined at three fill levels, and ultimately the depressurization and bulk temperature trends of the KSC tests were predicted with good accuracy.

Swanger, Adam M.↗

Experimental Results of Integrated Refrigeration and Storage System Testing

Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

Notardonato, W. U.↗

Modeling the spatiotemporal organization of velocity storage in the vestibuloocular reflex by optokinetic studies

1. A generalized three-dimensional state space model of visual vestibular interaction was developed. Matrix and dynamical system operators associated with inputs from the semicircular canals, otolith velocity estimator, and the visual system have been incorporated into the model, which focus on their relationship to the velocity storage integrator. 2. A relationship was postulated between the eigenvalues and the direction of the eigenvectors of the system matrix and the orientation of the spatial vertical. It was assumed that the system matrix for a tilted position was a composition of two linear transformations of the system matrix for the upright position. One transformation modifies the eigenvalues of the system matrix, whereas another rotates the eigenvectors of the system matrix. The pitch and roll eigenvectors rotate with the head, whereas the yaw axis eigenvector remains approximately spatially invariant. 3. Based on the three-dimensional model, a computational procedure was formulated to identify the eigenvalues and eigenvectors of the system matrix with the use of a modification of the marquardt algorithm. With the use of data obtained from a monkey, it was shown that the three-dimensional behavior of velocity storage cannot be predicted solely in terms of its time constants, i.e., the inverse of its eigenvalues. With the use of the same eigenvalues the data could either be fit or not fit, depending on the eigenvector directions. Therefore, it is necessary to specify eigenvector directions when characterizing velocity storage in three dimensions. 4. Parameters found with the use of the Marquardt algorithm were incorporated into the model. Diagonal matrices in a head coordinate frame were introduced for coupling the visual system to the integrator and to the direct optokinetic pathway. Simulations of optokinetic nystagmus (OKN) and optokinetic after-nystagmus (OKAN) were run. The model predicted the behavior of yaw and pitch OKN and OKAN when the animal is upright. It also predicted the cross-coupling in the side down position. The trajectories in velocity space were also accurately simulated. 5. One of the predictions of the model is that when the stimulus direction is along an eigenvector, the trajectory in velocity space is a straight line. Using the "spectral width" of the residuals from a straight line sequence during OKAN, we developed a methodology to estimate how close the OKAN decay was to an eigenvector trajectory. 6. Thus we have developed a model-based approach for studying and interpreting the response characteristics of velocity storage in three dimensions.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

National Aeronautics and Space Administration fundamental research program. Information utilization and evaluation

In the second half of the 1980's NASA can expect to face difficult choices among alternative fundamental and applied research, and development projects that could potentially lead to improvements in the information systems used to manage renewable resources. The working group on information utilization and evaluation believes that effective choices cannot be made without a better understanding of the current and prospective problems and opportunities involved in the application of remote sensing to improve renewable research information systems. A renewable resources information system is defined in a broad context to include a flow of data/information from: acquisition through processing, storage, integration with other data, analysis, graphic presentation, decision making, and assessment of the affects of those decisions.

Estes, J. E.↗

Thermal storage analysis for large manned space platforms

High electrical power and waste heat rejection is projected for future manned low earth orbit space platforms, such as Space Station. The high heat rejection, optical coating degradation, long operating life with minimum maintenance requirements pose a challenging thermal management design problem. System optimization, with respect to radiator area and weight, indicate the requirement for thermal storage. This paper examines the thermal storage benefits, determines the characteristics as applied to different TMS concepts (e.g., centralized, decentralized), and examines the similarities and differences of thermal storage integration with single-phase and two-phase systems for a study baseline 75 kWe low earth orbit platform.

Lehtinen, A. M.↗

A new light on caloric test--what was disclosed by three dimensional analysis of caloric nystagmus?

For better understanding of caloric nystagmus, this phenomenon will be reviewed historically in three stages. 1) The first light on caloric nystagmus was thrown by Barany 1906. Through direct observation of eye movements, Barany established the caloric test as an important tool to determine the side of lesion for vertigo. 2) The second light is shed by electrooculogram (EOG) from the late 1950th. EOG enabled qualitative analysis of caloric nystagmus, and proved Barany's convection theory, but resulted in neglect of vertical and roll eye movements. 3) The third light is gained by 3D recording of eye movements started from the late 1980th. 3D recordings of eye movements enabled us to analyze the spatial orientation of caloric nystagmus, and disclose the close correlation of the nystagmus components in the head vertical and the space vertical planes, suggesting a contribution of the velocity storage integrator. The 3D property of caloric nystagmus will be explained in detail.

Caloric Tests/history↗