Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrating sphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Optical multiple sample vacuum integrating sphere

An integrating sphere comprised of a uniform difusely reflecting spherical cavity, having mutually transverse input and output ports, and a linear sample transport mechanism is described. The sample transport mechanism is secured so that the multiple samples can be brought into registration with the input port, one at a time, without having to open or disassemble the apparatus when a change of sample is desired. A vacuum tight seal is provided between the cavity and the transport mechanism. This maintains the integrity of a vacuum generated with the sphere when attached to the source of optical energy. The device is utilized to test emissive characteristics such as the relative fluorescence quantum efficiency of a dye sample placed in the path of a monochromatic optical energy source coupled to the input port while having a light detector coupled to the output port.

Butner, C. L.↗

Integrating sphere theory

Integrating sphere theory with wall mounted specular sample in reflectance and transmittance measurements

Finkel, M. W.↗

Optical Integrating Sphere for Vacuum Ultraviolet

Optical integrating sphere with integral sliding sample holder saves time by allowing radiometric measurements made on each of four samples without breaking vacuum. Designed to operate with interior evacuated so dye samples illuminated with short-wavelength ultraviolet strongly absorbed by air; need not be evacuated when using longer wavelengths. Device mounts on monochromator and evacuated through port that admits light from monochromator.

Butner, C. L.↗

Development and Performance of a Filter Radiometer Monitor System for Integrating Sphere Sources

The NASA Goddard Space Flight Center (GSFC) Radiometric Calibration Laboratory (RCL) maintains several large integrating sphere sources covering the visible to the shortwave infrared wavelength range. Two critical, functional requirements of an integrating sphere source are short and long-term operational stability and repeatability. Monitoring the source is essential in determining the origin of systemic errors, thus increasing confidence in source performance and quantifying repeatability. If monitor data falls outside the established parameters, this could be an indication that the source requires maintenance or re-calibration against the National Institute of Science and Technology (NIST) irradiance standard. The GSFC RCL has developed a Filter Radiometer Monitoring System (FRMS) to continuously monitor the performance of its integrating sphere calibration sources in the 400 to 2400nm region. Sphere output change mechanisms include lamp aging, coating (e.g. BaSO4) deterioration, and ambient water vapor level. The Filter Radiometer Monitor System (FRMS) wavelength bands are selected to quantify changes caused by these mechanisms. The FRMS design and operation are presented, as well as data from monitoring four of the RCL s integrating sphere sources.

Ding, Leibo↗

Prediction of tissue optical properties using the Monte Carlo modeling of photon transport in turbid media and integrating spheres

Monte Carlo methods are an established technique for simulating light transport in biological tissue. Integrating spheres make experimental measurements of the reflectance and transmittance of a sample straightforward and inexpensive. This work presents an extension to existing Monte Carlo photon transport methods to simulate integrating sphere experiments. Crosstalk between spheres in dual-sphere experiments is accounted for in the method. Analytical models, previous works on Monte Carlo photon transport, and experimental measurements of a synthetic tissue phantom validate this method. We present two approaches for using this method to back-calculate the optical properties of samples. Experimental and simulation uncertainties are propagated through both methods. Both back-calculation methods find the optical properties of a sample accurately and precisely. Our model is implemented in standard Python 3 and CUDA C++ [J. Nickolls, I. Buck, M. Garland, and K. Skadron, ACM Queue 6 , 40 ( 2008 ) ] and is publicly available in Code 1.

Cook, Patrick D. (ORCID:0000000279345428)↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗

Characterization of Lubricants on Ball Bearings by FT-IR Using an Integrating Sphere

Fourier Transform-Infrared reflectance microspectroscopy has been used extensively for the examination of coatings on nonplanar surfaces such as ball bearings. While this technique offers considerable advantages, practical application has many drawbacks, some of which are easily overcome by the use of integrating sphere technology. This paper describes the use of an integrating sphere for the quantification of thin layers of lubricant on the surface of ball bearings and the parameters which require optimization in order to obtain reliable data. Several applications of the technique are discussed including determination of lubricant load on 12.7 mm steel ball bearings and the examination of degraded lubricant on post mortem specimens.

Street, K. W.↗

Comparing optical four-flux model results with experimental data obtained by integrating sphere measurements

Four-flux theory is a way to model scattering through multiple layers of a system based on diffuse and collimated properties. When compared with measurement results obtained using an integrating sphere or a goniophotometer, an approximation is often made as the physical instrument cannot separate the collimated component from the diffuse light scattered in the forward direction. This paper tries to clarify the meaning of the word diffuse for the different cases and outlines simple corrections to improve the accuracy when comparing four-flux models and measured data based on sample haze and the geometry of the integrating sphere.

Bilokur, Maryna (ORCID:0000000191839650)↗

Optical integrating sphere operates at visible and infrared wavelengths

An optical integrating sphere with a faceted reflective lining on the inside surface will provide light randomization /mixing of diffusely and specularly reflected light/ with relatively few reflections. The improved sphere has a sufficiently high reflectivity for both visible and infrared radiation.

Aisenberg, S.↗

Integrating sphere transmissometer for field measurement of leaf transmittance

A simple field-rated transmissometer is described for rapidly determining the normal hemispherical transmittance T(0 deg, 2 pi) of leaves measured in situ in the four Landsat wavelength bands. The transmissometer requires direct solar illumination of the leaf sample. It collects the transmitted light with an integrating sphere and measures the collected light using a commercially available radiometer. The transmittances determined by the transmissometer are comparable with those measured by a labortory spectrophotometer with an integrating sphere attachment.

Vanderbilt, V. C.↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 26-October 7, 2022

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 26 to October 7, 2022. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS varied from -0.80 W/m2 to 0.29 W/m2 and standard deviation (sd) from 0.98 W/m2 to 1.78 W/m2. The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 2.07 to 5.03 W/m2 with sd from 2.64 W/m2 to 2.67 W/m2.

14 SOLAR ENERGY↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 25-October 6, 2023

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 25 to October 6, 2023. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS9 varied from -0.75 W/m 2 to 0.76 W/m 2 , standard deviation (sd) from 0.78 W/m 2 to 1.04 W/m 2 , and uncertainty U95 from 1.96 W/m 2 to 2.07 W/m 2 . The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 1.64 to 3.96 W/m 2 , sd from 1.70 W/m 2 to 1.86 W/m 2 , and uncertainty U 95 from 3.78 W/m 2 to 5.42W/m 2 . Note that from September 25th at 18:31 to September 29 th at 5:30 ACP96F3 irradiance is calculated using Bruce, et al 2023 method.

47 OTHER INSTRUMENTATION↗