Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnected systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III – Grid Interconnection System Evaluator

This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

14 SOLAR ENERGY↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Process for making a multilayer interconnect system

A process for making an interconnect system for a multilayer circuit pattern. The interconnect system is formed having minimized through-hole space consumption so as to be suitable for high density, closely meshed circuit patterns.

Zachry, Clyde L.↗

Random vibration of interconnected systems.

Random vibration of interconnected systems, analyzing power flow and energy levels in linear oscillator interacting with environments, using Thevenin-Norton representations

Crandall, S. H.↗

Toward Interpreting Failure in Sintered-Silver Interconnection Systems

The mechanical strength and subsequent reliability of a sintered-silver interconnection system is a function of numerous independent parameters. That system is still undergoing process development. Most of those parameters (e.g., choice of plating) are arguably and unfortunately taken for granted and are independent of the silver s cohesive strength. To explore such effects, shear strength testing and failure analyses were completed on a simple, mock sintered-silver interconnection system consisting of bonding two DBC ceramic substrates. Silver and gold platings were part of the test matrix, as was pre-drying strategies, and the consideration of stencil-printing vs. screen-printing. Shear strength of sintered-silver interconnect systems was found to be was insensitive to the choice of plating, drying practice, and printing method provided careful and consistent processing of the sintered-silver are practiced. But if the service stress in sintered silver interconnect systems is anticipated to exceed ~ 60 MPa, then the system will likely fail.

Wereszczak, Andrew A↗

Interconnect system with friction fit backshell

Various technologies described herein pertain to interconnect systems for electrical cables. An interconnect system can include a connector, an adapter ring, and a backshell. The connector includes a threaded distal coupling portion. The adapter ring includes a threaded proximal coupling portion and a non-threaded distal coupling portion. The backshell includes a proximal coupling portion and a port. The threaded proximal coupling portion of the adapter ring and the threaded distal coupling portion of the connector can be mechanically attached. Additionally, the proximal coupling portion of the backshell and the non-threaded distal coupling portion of the adapter ring can be mechanically attached. A wire bundle can enter the backshell through the port, pass through the adapter ring, and terminate at the connector. A shield that encloses the wire bundle can terminate at the backshell such that an end of the shield is positioned around an outer surface of the port.

42 ENGINEERING↗

Interconnect system with friction fit backshell

Various technologies described herein pertain to interconnect systems for electrical cables. An interconnect system can include a connector, an adapter ring, and a backshell. The connector includes a threaded distal coupling portion. The adapter ring includes a threaded proximal coupling portion and a non-threaded distal coupling portion. The backshell includes a proximal coupling portion and a port. The threaded proximal coupling portion of the adapter ring and the threaded distal coupling portion of the connector can be mechanically attached. Additionally, the proximal coupling portion of the backshell and the non-threaded distal coupling portion of the adapter ring can be mechanically attached. A wire bundle can enter the backshell through the port, pass through the adapter ring, and terminate at the connector. A shield that encloses the wire bundle can terminate at the backshell such that an end of the shield is positioned around an outer surface of the port.

42 ENGINEERING↗

Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Open System Interconnection - NASA program communications of the future

Open Systems Interconnection (OSI) standards are being developed by the ISO and the Consultative Committee on International Telephone and Telegraph with the support of industry. These standards are being developed to allow the interconnecting of computer systems and the interworking of applications such that the applications can be independent of any equipment manufacturer. Significant progress has been made, and the establishment of government OSI standards is being considered. There is considerable interest within NASA in the potential benefits of OSI and in communications standards in general. The OSI standards are being considered for possible application in the Space Station onboard data management system. The OSI standards have reached a high level of maturity, and it is now imperative that NASA plan for future migration to OSI where appropriate.

Brady, Charles D.↗

Renewable Systems Interconnection: Executive Summary

The U.S. Department of Energy launched the Renewable Systems Interconnection (RSI) study in 2007 to address the challenges to high penetrations of distributed renewable energy technologies. The RSI study consists of 14 additional reports.

14 SOLAR ENERGY↗

A reference model for space data system interconnection services

The widespread adoption of standard packet-based data communication protocols and services for spaceflight missions provides the foundation for other standard space data handling services. These space data handling services can be defined as increasingly sophisticated processing of data or information received from lower-level services, using a layering approach made famous in the International Organization for Standardization (ISO) Open System Interconnection Reference Model (OSI-RM). The Space Data System Interconnection Reference Model (SDSI-RM) incorporates the conventions of the OSIRM to provide a framework within which a complete set of space data handling services can be defined. The use of the SDSI-RM is illustrated through its application to data handling services and protocols that have been defined by, or are under consideration by, the Consultative Committee for Space Data Systems (CCSDS).

Pietras, John↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Panel C report: Standards needed for the use of ISO Open Systems Interconnection - basic reference model

The use of an International Standards Organization (ISO) Open Systems Interconnection (OSI) Reference Model and its relevance to interconnecting an Applications Data Service (ADS) pilot program for data sharing is discussed. A top level mapping between the conjectured ADS requirements and identified layers within the OSI Reference Model was performed. It was concluded that the OSI model represents an orderly architecture for the ADS networking planning and that the protocols being developed by the National Bureau of Standards offer the best available implementation approach.

Source record↗

Vector Lyapunov Functions for Stochastic Interconnected Systems

Theoretical paper presents set of sufficient conditions for asymptotic and exponential stability with probability 1 for class of stochastic interconnected systems. Theory applicable to complicated, large-scale mechanical or electrical systems, and, for several design problems, it reduces computational difficulty by relating stability criteria to fundamental structural features of system.

Boussalis, D.↗