Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface failure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fiber-matrix interface failures

Interface fractures of aluminum-graphite composites under transverse loading are expected to occur within the graphite fibers, but very near the interface. Residual stresses in aluminum, reinforced with the new high modulus pitch-based fibers, are much lower than would be expected based on simple elasticity calculations. The excess stress may be relaxed by shearing internal to the fibers or at the interface rather than by plastic flow of the matrix. The internal shearing also occurs during repeated thermal cycling of these composites; the fibers are repeatedly intruded, then extruded, during repeated temperature excursions.

Rabenberg, Lew↗

An analysis of fiber-matrix interface failure stresses for a range of ply stress states

A graphite/bismaleimide laminate was prepared without the usual fiber treatment and was tested over a wide range of stress states to measure its ply cracking strength. These tests were conducted using off-axis flexure specimens and produced fiber-matrix interface failure data over a correspondingly wide range of interface stress states. The absence of fiber treatment, weakened the fiber-matrix interfaces and allowed these tests to be conducted at load levels that did not yield the matrix. An elastic micromechanics computer code was used to calculate the fiber-matrix interface stresses at failure. Two different fiber-array models (square and diamond) were used in these calculations to analyze the effects of fiber arrangement as well as stress state on the critical interface stresses at failure. This study showed that both fiber-array models were needed to analyze interface stresses over the range of stress states. A linear equation provided a close fit to these critical stress combinations and, thereby, provided a fiber-matrix interface failure criterion. These results suggest that prediction procedures for laminate ply cracking can be based on micromechanics stress analyses and appropriate fiber-matrix interface failure criteria. However, typical structural laminates may require elastoplastic stress analysis procedures that account for matrix yielding, especially for shear-dominated ply stress states.

Crews, J. H.↗

Determination of fiber-matrix interface failure parameters from off-axis tests

Critical fiber-matrix (FM) interface strength parameters were determined using a micromechanics-based approach together with failure data from off-axis tension (OAT) tests. The ply stresses at failure for a range of off-axis angles were used as input to a micromechanics analysis that was performed using the personal computer-based MICSTRAN code. FM interface stresses at the failure loads were calculated for both the square and the diamond array models. A simple procedure was developed to determine which array had the more severe FM interface stresses and the location of these critical stresses on the interface. For the cases analyzed, critical FM interface stresses were found to occur with the square array model and were located at a point where adjacent fibers were closest together. The critical FM interface stresses were used together with the Tsai-Wu failure theory to determine a failure criterion for the FM interface. This criterion was then used to predict the onset of ply cracking in angle-ply laminates for a range of laminate angles. Predictions for the onset of ply cracking in angle-ply laminates agreed with the test data trends.

Naik, Rajiv A.↗

Preliminary System Interface Failure Mode Analysis for Two Advanced Reactors

This study explores two distinct Balance of Plant (BOP) configurations: the Rankine cycle for a sodium-cooled fast reactor (SFR) and the Brayton cycle for a gas-cooled reactor (GCR). As representative designs, the Power Reactor Innovative Small Module (PRISM) by GE Hitachi Nuclear Energy was selected for the SFR, while the Gas Turbine Modular Helium Reactor (GT MHR) by General Atomics was chosen for the gas-cooled reactor. Both configurations were adapted to deliver high-quality heat for industrial applications. A Failure Modes and Effects Analysis (FMEA) was conducted for each system to identify critical failure modes affecting key components. This study marks the first phase of a two-step design optimization approach, integrating FMEA into the design process. Based on the analysis, design modifications and mitigation strategies were proposed to enhance system resilience. The second phase, to be detailed in a subsequent report, will focus on the role of the control system in mitigating these failures. The FMEA serves as a foundation for defining the control topology, ensuring system resilience against component failures that could compromise essential functions, such as electricity and heat production.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interfacial Atomistic Mechanisms of Lithium Metal Stripping and Plating in Solid–State Batteries

All-solid-state batteries based on a Li metal anode represent a promising next-generation energy storage system, but are currently limited by low current density and short cycle life. Further research to improve the Li metal anode is impeded by the lack of understanding in its failure mechanisms at lithium–solid interfaces, in particular, the fundamental atomistic processes responsible for interface failure. Here, using large-scale molecular dynamics simulations, the first atomistic modeling study of lithium stripping and plating on a solid electrolyte is performed by explicitly considering key fundamental atomistic processes and interface atomistic structures. In the simulations, the interface failure initiated with the formation of nano-sized pores, and how interface structures, lithium diffusion, adhesion energy, and applied pressure affect interface failure during Li cycling are observed. By systematically varying the parameters of solid-state lithium cells in the simulations, the parameter space of applied pressures and interfacial adhesion energies that inhibit interface failure during cycling are mapped to guide selection of solid-state cells. Furthermore, this study establishes the atomistic modeling for Li stripping and plating, and predicts optimal solid interfaces and new strategies for the future research and development of solid-state Li-metal batteries.

25 ENERGY STORAGE↗

Interfaces and failure mechanisms in Al-SiC composites

Aluminum alloys reinforced with silicon carbide whiskers exhibit significantly higher strength and modulus than the unreinforced alloys. However, the composites also exhibit low ductility and poor fracture toughness for reasons which are not well-understood. In this study, high resolution and conventional TEM techniques are used to analyze interface microstructure and failure mechanisms in P/M 2124 and 6061 aluminum alloys reinforced with silicon carbide whiskers. Interfacial oxides are typical of both composite materials, often distributed in clusters or in a discrete layer 2-5 nm thick along the whisker-matrix interface. Highly deformed regions beneath bulk tensile fracture surfaces reveal possible fracture nucleation centers as well as sites of stress concentration where intense plastic strain has occurred. Observations of such highly deformed regions include (1) void initiation at whisker ends, (2) interface decohesion involving the thin oxide layer, (3) transverse cracks in whiskers, and (4) cracks in large constituent particles. TEM results are presented and discussed in relation to mechanisms of composite failure.

Nutt, S. R.↗

An IIPG-Based Finite Element Framework in MOOSE for Modeling Fiber Reinforced Composite Failure Governed by Extrinsic Cohesive Laws

Many material and structure failures are initiated at the interface between two distinctive materials, such as the debonding of interfaces of matrix/fiber of composites or bulk matrix/inclusion in metals at micro-scales. Accurate and robust modeling of these interface failures is critical to the design of novel material and structure with improved functionality. This paper presents a robust implementation of a discontinuous Galerkin finite element method in MOOSE based on the Incomplete Interior Penalty Galerkin scheme for modeling material interface behavior. This DG-based interface method naturally accommodates important extrinsic cohesive zone material models and is capable of modeling the failures of material interfaces across which material properties are highly distinctive. We demonstrate a good performance of the proposed method using single fiber and multiple fiber debonding problems.

97 MATHEMATICS AND COMPUTING↗

An IIPG-based finite element framework in MOOSE for modeling fiber reinforced composite failure governed by extrinsic cohesive laws

Fiber reinforced composites (FRC) are widely applied to many important engineering structures such as silicon carbide ceramic matrix composite (SiC CMC) of nuclear fuel claddings. Many material and structure failures are initiated at the interface between two distinctive materials, such as the debonding of interfaces of matrix/fiber of composites or bulk matrix/inclusion in metals at micro-scales. Accurate and robust modeling of these interface failures is critical to the development of novel material and structure with improved functionality. This paper presents a discontinuous Galerkin (DG) finite element method based on the Incomplete Interior Penalty scheme and its implementation in MOOSE for modeling material interface behaviors. The proposed method naturally accommodates important extrinsic cohesive zone material models and is capable of modeling the failures of material interfaces across which material properties are highly distinctive. We demonstrate a good performance of the proposed method using single fiber and multiple fiber debonding problems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feedstock-Conversion Interface Consortium: Failure Mode and Effects Analysis Summary Report (FY2022)

This report provides an overview of the development of failure modes and effects analysis (FMEA) and its implementation as a systematic criticality and risk assessment tool supporting a quality by design (QbD) approach for FCIC research. This report also provides a high-level overview of the results for the FMEA evaluation of two feedstock preprocessing system configurations: (1) generation of pine residue materials for high-temperature pyrolysis conversion and (2) generation of corn stover materials for low-temperature conversion using deacetylation and disc mechanical refining pretreatment for fermentation to hydrocarbons. For the results presented in this report, our FMEA interviews included two approaches. The first approach was to perform FMEA interviews for the entire system of unit operations giving a wholistic system level view. The second approach consisted of detailed interviews for each individual unit operation within the system allowing for a “deep dive” into the specific failures for the individual components within the configuration. These two approaches provide different resolutions of information. The FMEA results of this report were focused on failures associated with meeting critical quality attributes (CQAs) identified for the target conversion processes for each processed feedstock type. The information gathered through the FMEA interviews include estimations of risk scores for meeting each given CQA specification, identification of the impacts for not meeting a CQA specification, capturing causes associated with material attributes and process parameters for each failure, identification of current detection methods, and speculation of potential mitigation strategies for decreasing a failure’s risk score. The complete results of all FMEA interviews are provided in the Appendices of this report.

09 BIOMASS FUELS↗

Influence of interface on composite failure

The influence of the interface on the composite system behavior is investigated by analytical modeling. The stress analysis is based on the two-dimensional finite element procedure in which twelve-node isoparametric elements with cubic shape functions are used. The location of possible failure sites is predicted by the strain energy density (SED) failure theory which assumes failure to coincide with locations of minimum SED while the locations of maximum SED correspond to regions of excessive distortion or yielding. The results of the analysis show that the way in which the modulus of elasticity varies within the interface is as important in modeling as the average interface modulus.

Sih, G. C.↗

Application of fiber bridging models to fatigue crack growth in unidirectional titanium matrix composites

Several fiber bridging models were reviewed and applied to study the matrix fatigue crack growth behavior in center notched (0)(sub 8) SCS-6/Ti-15-3 and (0)(sub 4) SCS-6/Ti-6Al-4V laminates. Observations revealed that fatigue damage consisted primarily of matrix cracks and fiber matrix interfacial failure in the (0)(sub 8) SCS-6/Ti-15-3 laminates. Fiber-matrix interface failure included fracture of the brittle reaction zone and cracking between the two carbon rich fiber coatings. Intact fibers in the wake of the matrix cracks reduce the stress intensity factor range. Thus, an applied stress intensity factor range is inappropriate to characterize matrix crack growth behavior. Fiber bridging models were used to determine the matrix stress intensity factor range in titanium metal matrix composites. In these models, the fibers in the wake of the crack are idealized as a closure pressure. An unknown constant frictional shear stress is assumed to act along the debond or slip length of the bridging fibers. The frictional shear stress was used as a curve fitting parameter to available data (crack growth data, crack opening displacement data, and debond length data). Large variations in the frictional shear stress required to fit the experimental data indicate that the fiber bridging models in their present form lack predictive capabilities. However, these models provide an efficient and relatively simple engineering method for conducting parametric studies of the matrix growth behavior based on constituent properties.

Bakuckas, J. G., Jr.↗

Interfaces - Weak Links, Yet Great Opportunities

Inadequate turbomachine interface design can rapidly degrade system performance, yet provide great opportunity for improvements. Engineered coatings of seals and bearing interfaces are major issues in the operational life of power systems. Coatings, films, and combined use of both metals and ceramics play a major role in maintaining component life. Interface coatings, like lubricants, are sacrificial for the benefit of the component. Bearing and sealing surfaces are routinely protected by tribologically paired coatings such as silicon diamond like coatings (SiDLC) in combination with an oil lubricated wave bearing that prolongs bearing operational life. Likewise, of several methods used or researched for detecting interface failures, dopants within coatings show failures in functionally graded ceramic coatings. The Bozzolo-Ferrante-Smith (BFS) materials models and quantum mechanical tools, employed in interface design, are discussed.

Hendricks, Robert C.↗

Rethinking PCMI Failures Under Transient Conditions

Under PCMI conditions, the cladding strain is driven by either pellet swelling during normal operation or pellet thermal expansion in transients. The loading in PCMI is displacement controlled because friction between the pellet and the cladding results in a strain compatibility at the pellet/cladding interface. Failure is known to occur under PCMI loading conditions during operation when normal power changes result in release of iodine (and other fission products) causing stress corrosion cracking where the crack-propagation rate is dependent upon the cladding stress but slow relative to strictly mechanical failures. Failures after normal power changes are often referred to as failure by pellet-cladding interaction or PCI to distinguish it from PCMI. Such failures are considered displacement-controlled failures, as noted above, and occur with limited plastic strain. This is different to what is typically thought of as PCMI failure under transient conditions, either Anticipated Operational Occurrences (AOOs) or Reactivity Insertion Accidents (RIAs), which is generally assumed to occur once the cladding reaches a mechanical strain limit. But there are two features in the typical PCMI failure in an RIA that are not consistent with the PCMI assumptions. The first is the ductile shear failure feature in cross section and the second is a large crack opening post failure (e.g., see OI-11 failure in NSRR program). The ductile feature is indicative of a plastic instability that requires very large local strains, and the large crack opening must be the result of a release of energy, both of which are not expected if stress in the cladding was only driven by thermal expansion in the pellet. It is concluded that there must be a mechanism (likely related to rod internal pressure) that eliminates strain compatibility between the pellet and cladding – allowing strain localization to occur in what are known as PCMI transient failures. In some sense, these PCMI failures may actually be early burst failures that occur when thermal expansion causes uniform strains greater than a defined limit and fission gas pressure eliminate the strain compatibility

Cantonwine, Paul↗

Measurement of multiaxial ply strength by an off-axis flexure test

An off-axis flexure (OAF) test was performed to measure ply strength under multiaxial stress states. This test involves unidirectional off-axis specimens loaded in bending, using an apparatus that allows these anisotropic specimens to twist as well as flex without the complications of a resisting torque. A 3D finite element stress analysis verified that simple beam theory could be used to compute the specimen bending stresses at failure. Unidirectional graphite/epoxy specimens with fiber angles ranging from 90 deg to 15 deg have combined normal and shear stresses on their failure planes that are typical of 45 deg plies in structural laminates. Tests for a range of stress states with AS4/3501-6 specimens showed that both normal and shear stresses on the failure plane influenced cracking resistance. This OAF test may prove to be useful for generating data needed to predict ply cracking in composite structures and may also provide an approach for studying fiber-matrix interface failures under stress states typical of structures.

Crews, John H., Jr.↗

Advanced composites structural concepts and materials technologies for primary aircraft structures: Structural response and failure analysis

Non-linear analysis methods were adapted and incorporated in a finite element based DIAL code. These methods are necessary to evaluate the global response of a stiffened structure under combined in-plane and out-of-plane loading. These methods include the Arc Length method and target point analysis procedure. A new interface material model was implemented that can model elastic-plastic behavior of the bond adhesive. Direct application of this method is in skin/stiffener interface failure assessment. Addition of the AML (angle minus longitudinal or load) failure procedure and Hasin's failure criteria provides added capability in the failure predictions. Interactive Stiffened Panel Analysis modules were developed as interactive pre-and post-processors. Each module provides the means of performing self-initiated finite elements based analysis of primary structures such as a flat or curved stiffened panel; a corrugated flat sandwich panel; and a curved geodesic fuselage panel. This module brings finite element analysis into the design of composite structures without the requirement for the user to know much about the techniques and procedures needed to actually perform a finite element analysis from scratch. An interactive finite element code was developed to predict bolted joint strength considering material and geometrical non-linearity. The developed method conducts an ultimate strength failure analysis using a set of material degradation models.

Dorris, William J.↗

Characterization of unnotched SCS-6/Ti-15-3 metal matrix composites at 650 C

Ti-15-3 reinforced with SCS-6 silicon carbide fibers, in five different layups, was tested at 650 C to determine monotonic and fatigue strengths, basic mechanical properties, and damage initiation and progression. The elevated temperature results were compared to those obtained at room temperature. Analytical predictions were made of the monotonic stress-strain response as well as cyclic stress-strain hysteresis. The fiber reinforcement was found to significantly increase the static and fatigue strengths of the laminates over that of the matrix material at elevated temperature while the increase was insignificant at room temperature. Initial damage, in either the fibers or the matrix, was partitioned as a function of the life and applied strain range in the constituents. High strains and short lives resulted in multiple fiber failure with no signs of matrix fatigue cracking. Low strains and long lives resulted in extensive matrix cracking and no fiber breaks away from the fracture surface. At 650 C the matrix was too weak to cause fiber-matrix interface failure prior to matrix yielding. Laminate fatigue lives were hypothesized to be a function of the 0 deg fiber stress. More scatter was found in the 0 deg fiber stress vs. high temperature fatigue life data than for the room temperature data. An initial unloading modulus that was greater than the initial loading modulus was observed in the elevated temperature fatigue tests.

Pollock, W. D.↗

Characterization of unnotched SCS-6/Ti-15-3 metal matrix composites at 650 C

Ti-15-3 reinforced with SCS-6 silicon carbide fibers, in five different layups, was tested at 650 C to determine monotonic and fatigue strengths, basic mechanical properties, and damage initiation and progression. The elevated temperature results were compared to those obtained at room temperature. Analytical predictions were made of the monotonic stress-strain response as well as cyclic stress-strain hysteresis. The fiber reinforcement was found to significantly increase the static and fatigue strengths of the laminates over that of the matrix material at elevated temperature while the increase was insignificant at room temperature. Initial damage, in either the fibers or the matrix, was partitioned as a function of the life and applied strain range in the constituents. High strains and short lives resulted in multiple fiber failure with no signs of matrix fatigue cracking. Low strains and long lives resulted in extensive matrix cracking and no fiber breaks away from the fracture surface. At 650 C the matrix was too weak to cause fiber-matrix interface failure prior to matrix yielding. Laminate fatigue lives were hypothesized to be a function of the 0 deg fiber stress. More scatter was found in the 0 deg fiber stress vs. high temperature fatigue life data than for the room temperature data. An initial unloading modulus that was greater than the initial loading modulus was observed in the elevated temperature fatigue tests.

Pollock, William D.↗