Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface mechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanism of generating fast electrons by an intense laser at a steep overdense interface

The acceleration and heating of electrons by an intense laser normally incident on a steep overdense plasma interface is investigated using the particle-in-cell code osiris. Energetic electrons are generated by the laser's electric field in the vacuum region within {lambda}/4 of the surface. Only those electrons which originate within the plasma with a sufficiently large transverse momentum can escape the plasma. This mechanism relies on the standing wave structure created by the incoming and reflected wave and is therefore very different for linear and circularly polarized light.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanisms of nonequilibrium electron-phonon coupling and thermal conductance at interfaces

We study the electron and phonon thermal coupling mechanisms at interfaces between gold films with and without Ti adhesion layers on various substrates via pump-probe time-domain thermoreflectance. The coupling between the electronic and the vibrational states is increased by more than a factor of five with the inclusion of an ∼3 nm Ti adhesion layer between the Au film and the non-metal substrate. Furthermore, we show an increase in the rate of relaxation of the electron system with increasing electron and lattice temperatures induced by the laser power and attribute this to enhanced electron-electron scattering, a transport channel that becomes more pronounced with increased electron temperatures. The inclusion of the Ti layer also results in a linear dependence of the electron-phonon relaxation rate with temperature, which we attribute to the coupling of electrons at and near the Ti/substrate interface. This enhanced electron-phonon coupling due to electron-interface scattering is shown to have negligible influence on the Kapitza conductances between the Au/Ti and the substrates at longer time scales when the electrons and phonons in the metal have equilibrated. These results suggest that only during highly nonequilibrium conditions between the electrons and phonons (T{sub e} ≫ T{sub p}) does electron-phonon scattering at an interface contribute to thermal boundary conductance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of fluid injection-induced fault reactivation using coupled fluid flow and mechanical interface model

The present study is aimed at developing a numerical model to reproduce coupled hydro-mechanical processes associated with fault reactivation by fluid injection in low permeability rock, as part of the DECOVALEX-2019 project Task B. We proposed a modeling approach for simulating the processes using the TOUGH-FLAC simulator, and modeled a fault reactivation experiment conducted at Mont Terri Rock Laboratory in Switzerland. The first step of the study involved benchmark calculations considering a simplified fault plane and geometry. Fluid flow along a fault was modeled using elements of aperture-sized thickness on the basis of Darcy's law and the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by zero-thickness interface elements in FLAC3D upon which a slip and/or separation is allowed. A methodology to connect a TOUGH2 volume element to a FLAC3D interface element was developed for handling the hydro-mechanical interactions on the fault during fluid injection. Two different fault models for describing the evolutions of hydraulic aperture by elastic fracture opening and failure-induced aperture increase were considered in the benchmark calculations. In the coupling process, the changes in geometrical features and hydrological properties induced by mechanical deformation were continuously updated. The transient responses of the fault and host rock to stepwise pressurization were examined during the simulation. The hydro-mechanical behavior, including the injection flow rate, pressure distribution around the borehole, stress conditions, and displacements in normal and shear directions were monitored in the surrounding rock and along the fault. The results of benchmark calculations suggest that the developed model reasonably represents the hydro-mechanical behavior of a fault and the surrounding rock. This modeling approach was applied to the fault reactivation experiment of the Mont Terri Rock Laboratory. In this interpretive modeling, a parametric study was conducted to examine the effects of input parameters regarding in situ stress and fault properties on the hydro-mechanical responses of the fault to water injection. Then, an optimal parameter set to reproduce the field experiment results was chosen by trial-and-error. The injection flow rate and pressure response during fault reactivation closely matched those obtained at the site, which indicates the capability of the model to appropriately capture the progressive pathway evolution during fault reactivation tests at the site. Finally, the anchor displacements were overestimated by the model, but a fair agreement was obtained in terms of the order of magnitude and the variation tendency.

58 GEOSCIENCES↗

Interface mechanics of carbon fibers with radially-grown carbon nanotubes

An atomistic modeling framework to investigate the interface/interphase of composite architecture with carbon fibers containing radially-grown carbon nanotubes (often called fuzzy fibers) is detailed in this paper. A polymeric functional coating for the carbon fiber surface, which also serves as a substrate for the CNT growth, is explicitly modeled. The tensile and transverse moduli of the fuzzy fiber/epoxy interphase is computed from virtual deformation simulations and compared to experimental values reported in literature, in order to validate the nanoscale model. Furthermore, the effect of the polymer substrate is studied by modeling the local interphase mechanics. Various modes of virtual loading provide the cohesive behavior of the local substrate/epoxy interphase. Conclusions are presented by comparing the material response of the interphase with and without the polymeric substrate. In this study, the integration of results from the nanoscale to an atomistically-informed subcell-based continuum level model is also demonstrated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In-situ, nanoscale fracture toughness measurements for improved mechanical interfaces

In this project, we demonstrated stable nanoscale fracture in single-crystal silicon using an in-situ wedge-loaded double cantilever beam (DCB) specimen. The fracture toughness KIC was calculated directly from instrumented measurement of force and displacement via finite element analysis with frictional corrections. Measurements on multiple test specimens were used to show K IC = 0.72 ± 0.07 MPa m 1/2 on {111} planes and observe the crack-growth resistance curve in <500 nm increments. The exquisite stability of crack growth, instrumented measurement of material response, and direct visual access to observe nanoscale fracture processes in an ideally brittle material differentiate this approach from prior DCB methods.

36 MATERIALS SCIENCE↗

Mechanisms of Interface Cleaning in Heterostructures Made from Polymer‐Contaminated Graphene

Abstract Heterostructures obtained from layered assembly of 2D materials such as graphene and hexagonal boron nitride have potential in the development of new electronic devices. Whereas various materials techniques can now produce macroscopic scale graphene, the construction of similar size heterostructures with atomically clean interfaces is still unrealized. A primary barrier has been the inability to remove polymeric residues from the interfaces that arise between layers when fabricating heterostructures. Here, the interface cleaning problem of polymer‐contaminated heterostructures is experimentally studied from an energy viewpoint. With this approach, it is established that the interface cleaning mechanism involves a combination of thermally activated polymer residue mobilization and their mechanical actuation. This framework allows a systematic approach for fabricating record large‐area clean heterostructures from polymer‐contaminated graphene. These heterostructures provide state‐of‐the‐art electronic performance. This study opens new strategies for the scalable production of layered materials heterostructures.

Huang, Zhujun↗

Capturing the softening in T91 steel annealed with molten LBE through interfacial gradient plasticity

In order to study the effect of annealing with molten lead–bismuth eutectic alloy (mLBE) on the mechanical properties of T91 steel, micropillar compression tests were analyzed through the consideration of mechanical interface energy terms within gradient plasticity. The stress–strain curves of the micropillars showed significant stochastic effects, characterized by a different elastic and plastic behavior response for each pillar. Among the various pillars, some exhibited a similar trilinear behavior. Scanning electron microscopy (SEM) images of these specimens demonstrated localized slip deformation and slip planes after compression, while transmission electron microscopy (TEM) images showed the presence of a severe slip zone along the random grain boundaries (RGBs), indicating that the GBs played a dominant role in the deformation/slip. By employing interfacial gradient plasticity that can explicitly account for the presence of GBs, the trilinear response was captured, allowing for the determination of the mechanical interface parameter. As anticipated the pillars which underwent severe slip at the GBs had a lower value for the mechanical interface parameter. Finally, annealing with mLBE can, therefore, in some cases result in softening in the overall stress–strain, as it lowers the mechanical interface energy of GBs.

36 MATERIALS SCIENCE↗

Nanoporous framework materials interfaced with mechanical sensors for highly-sensitive chemical sensing.

We will describe how novel nanoporous framework materials (NFM) such as metal-organic frameworks (MOFs) can be interfaced with common mechanical sensors, such as surface acoustic wave (SAW), microcantilever array, and quartz crystal microbalance (QCM) devices, and subsequently be used to provide selectivity and sensitivity to a broad range of analytes including explosives, nerve agents, and volatile organic compounds (VOCs). NFM are highly ordered, crystalline materials with considerable synthetic flexibility resulting from the presence of both organic and inorganic components within their structure. Chemical detection using micro-electro-mechanical-systems (MEMS) devices (i.e. SAWs, microcantilevers) requires the use of recognition layers to impart selectivity. Unlike traditional organic polymers, which are dense, the nanoporosity and ultrahigh surface areas of NFM allow for greater analyte uptake and enhance transport into and out of the sensing layer. This enhancement over traditional coatings leads to improved response times and greater sensitivity, while their ordered structure allows chemical tuning to impart selectivity. We describe here experiments and modeling aimed at creating NFM layers tailored to the detection of water vapor, explosives, CWMD, and volatile organic compound (VOCs), and their integration with the surfaces of MEMS devices. Molecular simulation shows that a high degree of chemical selectivity is feasible. For example, a suite of MOFs can select for strongly interacting organics (explosives, CWMD) vs. lighter volatile organics at trace concentrations. At higher gas pressures, the CWMD are deselected in favor of the volatile organics. We will also demonstrate the integration of various NFM on the surface of microcantiliver arrays, QCM crystals, and SAW devices, and describe new synthetic methods developed to improve the quality of NFM coatings. Finally, MOF-coated MEMS devices show how temperature changes can be tuned to improve response times, selectivity, and sensitivity.

36 MATERIALS SCIENCE↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗