Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Field-gradient measurement using a Stern-Gerlach atomic interferometer with butterfly geometry

Atomic interferometers have been studied as a promising device for precise sensing of external fields. Among various configurations, a particular configuration with a butterfly-shaped geometry has been designed to sensitively probe field gradients. Here, we introduce a Stern-Gerlach (SG) butterfly interferometer by incorporating magnetic field in the conventional butterfly-shaped configuration. Atomic trajectories of the interferometer can be flexibly adjusted by controlling magnetic fields to increase the sensitivity of the interferometer, while the conventional butterfly interferometer using Raman transitions can be understood as a special case. We also show that the SG interferometer can keep high contrast against a misalignment in position and momentum caused by the field gradient.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strongly coupled edge states in a graphene quantum Hall interferometer

Electronic interferometers using the chiral, one-dimensional (1D) edge channels of the quantum Hall effect (QHE) can demonstrate a wealth of fundamental phenomena. The recent observation of phase jumps in a Fabry-Pérot (FP) interferometer revealed anyonic quasiparticle exchange statistics in the fractional QHE. When multiple integer edge channels are involved, FP interferometers have exhibited anomalous Aharonov-Bohm (AB) interference frequency doubling, suggesting putative pairing of electrons into 2e quasiparticles. Here, we use a highly tunable graphene-based QHE FP interferometer to observe the connection between interference phase jumps and AB frequency doubling, unveiling how strong repulsive interaction between edge channels leads to the apparent pairing phenomena. By tuning electron density in-situ from filling factor v < 2 to v > 7, we tune the interaction strength and observe periodic interference phase jumps leading to AB frequency doubling. Our observations demonstrate that the combination of repulsive interaction between the spin-split v = 2 edge channels and charge quantization is sufficient to explain the frequency doubling, through a near-perfect charge screening between the localized and extended edge channels. Our results show that interferometers are sensitive probes of microscopic interactions and enable future experiments studying correlated electrons in 1D channels using density-tunable graphene.

42 ENGINEERING↗

The design of a line velocity interferometer for any reflector for inertial confinement experiments on the Z-machine

A line VISAR (Velocity Interferometer System for Any Reflector) has been designed and commissioned at the Sandia National Laboratory’s Z-machine. The instrument consists of an F/2 collection system, beam transport, and an interferometer table that contains two Mach–Zehnder type interferometers and an eight channel Gated Optical Imaging (GOI) system. The VISAR probe laser operates at the 532 nm wavelength, and the GOI bandpass is 540–600 nm. The output of each interferometer is passed to an optical streak camera with four selectable sweep speeds. The system is designed with three interchangeable optics modules to select a full field of view of 1 mm, 2 mm, or 4 mm. The optical beam transport system connects the target image plane to the interferometers and the gated optical imagers. The target is integrated into a sacrificial final optics assembly that is integral to the transport beamline.

Datte, P.↗

Machine-learning-based automatic small-angle measurement between planar surfaces in interferometer images: A 2D multilayer Laue lenses case

Here, we report a new machine-learning-based approach to automatically measure the small angle between multiple planar surfaces characterized by white light interferometers. By applying an unsupervised clustering algorithm, DBSCAN (Density-Based Spatial Clustering of Applications with Noise), the multiple surfaces in an interferometer image are automatically identified as distinct surfaces. The angles between every two surfaces are then calculated through the surface fitting. This method can be applied to multiple surfaces regardless of their shapes and locations and significantly simplifies the angle measurement procedure. Using the developed method, we have demonstrated a quick and precise angle measurement for the alignment of 2D Multilayer Laue Lenses (MLLs) for the development of high-resolution x-ray microscopy. This automatic, accurate, and robust small-angle measurement method is compatible with widely used white light interferometers and can be further applied to other metrology applications of interferometer results.

36 MATERIALS SCIENCE↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Slow Quasiparticle Dynamics and Anyonic Statistics in a Fractional Quantum Hall Fabry-Pérot Interferometer

Anyons are two-dimensional particles with fractional exchange statistics that emerge as elementary excitations of fractional quantum Hall phases. Experimentally, their exchange statistics can be measured in the edge-state Fabry-Pérot interferometer, wherein the presence of 𝑁 𝑞⁢𝑝 localized anyons contributes a phase 𝑁 𝑞⁢𝑝⁢ 𝜃 𝑎 to the interference pattern where 𝜃 𝑎 is twice the exchange phase. Here we report the observation of large, hysteretic phase jumps in a monolayer graphene Fabry-Pérot interferometer at 𝜈 = 1/3. When the filling factor is increased from 𝜈 < 1/3 toward the center of the plateau, we observe phase slips with magnitude Δ⁢𝜃 ≈ 2⁢𝜋/3, consistent with the addition of individual quasiparticles to the interferometer bulk. These phase slips occur as instantaneous jumps in the interference signal, with intervals between the jumps indicating quasiparticle equilibration times exceeding 20 min. We use this long timescale to investigate the effect of changes in interferometer area 𝐴 𝐼 and 𝑁 𝑞⁢𝑝 independently at fixed magnetic field, revealing a striking memory effect in the phase slip magnitude. In particular, as the 𝜈 =1/3 plateau is approached from higher filling, we observed phase slips with Δ⁢𝜃 significantly larger than 2⁢𝜋/3 over the same range of gate voltage where quantized jumps are seen for increasing 𝜈. We discuss this asymmetry in terms of bulk-edge coupling of quasiparticles localized near the edge or in the bulk, and argue that this effect can be qualitatively reconciled with theoretical expectations for strongly interacting quasiparticles in the presence of weak disorder and strongly nonequilibrium charge dynamics. Besides providing a replication of interferometric measurements sensitive to 𝜃 𝑎 , our results highlight the key role played by charge dynamics on signatures of the anyon phase, and demonstrate that fractional quasiparticles can be indefinitely localized in nonequilibrium configurations.

anyons↗

Dynamical quantum phase transitions in interacting atomic interferometers

Particle-wave duality has allowed physicists to establish atomic interferometers as celebrated complements to their optical counterparts in a broad range of quantum devices. In particular, interactions give rise to multiparticle correlations unavailable in linear interferometers. Here, we show that interactions lead to dynamical quantum phase transitions (DQPTs) between NOON states in an atomic interferometer. These transition points result from zeros of the Loschmidt echo, which approach the real axis of the complex time plane in the large-particle-number limit, and signify pair condensates, another type of exotic quantum states featured with prevailing two-body correlations. Such DQPTs thus provide us with a new angle to understand many-body states emergent from quantum nonequilibrium dynamics. Further, our work also suggests interacting atomic interferometers as a new tool for creating highly entangled states to beat the standard quantum limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometer response to geontropic fluctuations

We model vacuum fluctuations in quantum gravity with a scalar field, characterized by a high occupation number, coupled to the metric. The occupation number of the scalar is given by a thermal density matrix, whose form is motivated by fluctuations in the vacuum energy, which have been shown to be conformal near a light-sheet horizon. For the experimental measurement of interest in an interferometer, the size of the energy fluctuations is fixed by the area of a surface bounding the volume of spacetime being interrogated by an interferometer. We compute the interferometer response to these “geontropic” scalar-metric fluctuations, and apply our results to current and future interferometer measurements, such as LIGO and the proposed GQuEST experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Features of correlation measurements of the parameters of pulsed hyperspectral optical fields using an asymmetric interferometer

Differences in correlation measurements of the parameters of pulsed hyperspectral optical fields using symmetric and asymmetric interferometers are considered. It is shown analytically that the resulting cross-correlation function is sensitive to phase perturbations in the original wave field. The considered setup, which contains a telescopic reflective 4f system of parabolic mirrors in one arm, demonstrates that in the case of an asymmetric interferometer, the presence of aberrations leads to degradation of the reconstructed image, whereas in the case of symmetric interferometers these aberrations do not affect the result. (paper)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma↗

Impact of bulk-edge coupling on observation of anyonic braiding statistics in quantum Hall interferometers

Abstract Quantum Hall interferometers have been used to probe fractional charge and statistics of quasiparticles. We present measurements of a small Fabry–Perot interferometer in which the electrostatic coupling constants which affect interferometer behavior can be determined experimentally. Near the center of the ν = 1/3 state this device exhibits Aharonov–Bohm interference interrupted by a few discrete phase jumps, and Φ 0 oscillations at higher and lower magnetic fields, consistent with theoretical predictions for detection of anyonic statistics. We estimate the electrostatic parameters K I and K I L by two methods: using the ratio of oscillation periods in compressible versus incompressible regions, and from finite-bias conductance measurements. We find that the extracted K I and K I L can account for the deviation of the phase jumps from the theoretical anyonic phase θ a = 2 π /3. At integer states, we find that K I and K I L can account for the Aharonov–Bohm and Coulomb-dominated behavior of different edge states.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Correlation polarimeter-interferometer in the DIII-D tokamak

A correlation polarimeter-interferometer system has been developed for the DIII-D tokamak to detect small amplitude magnetic and density fluctuations. Two collinear, frequency-offset (5–15 MHz), orthogonally polarized (right- and left-handed, circularly polarized) electromagnetic waves at 650 GHz probing the plasma are used to detect the Faraday effect. A third, linearly polarized, electromagnetic wave serves as the local-oscillator to provide a measure of the line-averaged density. Correlation polarimetric measurement is accomplished by correlating the Faraday effect measured along the same line of sight using two independent detectors, whereas simultaneous correlation interferometric measurement is realized by correlating the line-averaged density measured at two different intermediate frequencies. The noise floor of the correlation polarimeter-interferometer has been demonstrated to be more than one order of magnitude lower than that of a standard polarimeter-interferometer measurement. Line-averaged correlation polarimetric-interferometric measurements in DIII-D H-mode plasmas show broadband (up to 750 kHz) magnetic and density fluctuations with amplitudes as low as 0.03 $Gauss$/$\sqrt{kHz}$ and 4 × 10 13 m –3 /$\sqrt{kHz}$, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust Quantum Control via Multipath Interference for Thousandfold Phase Amplification in a Resonant Atom Interferometer

We introduce a novel technique for enhancing the robustness of light-pulse atom interferometers against the pulse infidelities that typically limit their sensitivities. The technique uses quantum optimal control to favorably harness the multipath interference of the stray trajectories produced by imperfect atom-optics operations. We apply this method to a resonant atom interferometer and achieve thousandfold phase amplification, representing a 50-fold improvement over the performance observed without optimized control. Moreover, we find that spurious interference can arise from the interplay of spontaneous emission and many-pulse sequences and demonstrate optimization strategies to mitigate this effect. Given the ubiquity of spontaneous emission in quantum systems, these results may be valuable for improving the performance of a diverse array of quantum sensors. We anticipate our findings will significantly benefit the performance of matter-wave interferometers for a variety of applications, including dark matter, dark energy, and gravitational wave detection.

47 OTHER INSTRUMENTATION↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗