Search NASA⌕ Search

SEARCH · Search NASA

Results for “interferometry real-time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Range and Performance Optimized Version of the Computer-Aided Speckle Interferometry Algorithm for Real-Time Displacement-Strain Field Monitoring

Abstract This work presents an optimized implementation of the Computer-Aided Speckle Interferometry algorithm which enables full-field determination of displacements and strains on commodity Graphics Processing Units at high resolution and frame rates. By combining careful control of the average speckle size in a laser speckle pattern with a simple sampling rate conversion scheme, a compact representation of the optical speckle is achieved. This allows for optimal use of Graphics Processing Unit architecture with robust range extension. The optimal mapping of the Computer-Aided Speckle Interferometry algorithm to Graphics Processing Unit architecture is shown in detail, and a straightforward method for disambiguating large displacements is illustrated. Lastly, this paper demonstrates a two-step subimage-tapering modification to the original algorithm that enables robust range enhancement while maintaining resolution. Results from numerical simulations on synthetic speckle patterns are shown, and runtime performance metrics are provided, with performance ranging up to 60 frames per second in some cases. The method is suitable for interactive experimental mechanics research, process and testing or any application where real-time high-resolution displacement-strain monitoring is needed. A .NET Framework class library enabling the incorporation of the algorithm into 3rd -party applications is available for download.

42 ENGINEERING↗

Real-Time FPGA Implementation For Frequency Sweep Interferometry In The LBNF Complex

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, A. Jacob [Fermilab; Unlisted]↗

$Z$-Pinch Interferometry Analysis With the Fourier-Based TNT Code

Here, we present the analysis of interferometry diagnostics with the user-friendly Talbot Numerical Tool (TNT), a Fourier-based postprocessing code that enables real-time assessment of plasma systems. TNT performance was explored with visible and infrared interferometry in pulsed-power-driven Z -pinch configurations to expand its capabilities beyond Talbot X-ray interferometry in the high-intensity laser environment. TNT enabled accurate electron density characterization of magnetically driven plasma flows and shocks through phase-retrieval methods that did not require data modification or masking. TNT demonstrated enhanced resolution, detecting below 4 % fringe shift, which corresponds to 8.7 × 10 15 cm –2 within 28 μ m, approaching the laser probing system limit. TNT was tested against a well-known interferometry analysis software, delivering an average resolving power nearly ten times better (~28 μ m versus ~ 210 μ m) when resolving plasma ablation features. TNT demonstrated higher sensitivity when probing sharp electron density gradients in supersonic shocks. A maximum electron areal density of 4.1 × 10 17 cm –2 was measured in the shocked plasma region, and a minimum electron density detection of ~ 1.0 × 10 15 cm –2 was achieved. When probing colliding plasma flows, the calculations of the effective adiabatic index and the associated errors were improved from γ* = 2.6 ± 1.6 – 1.4 ± 0.2 with TNT postprocessing, contributing valuable data for the interpretation of radiative transport. Additional applications of TNT in the characterization of pulsed-power plasmas and beyond are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

White-light interferometry for early-stage metal oxide growth characterization

Oxidation of metals can provide a functional oxide film or an oxide layer that can lead to material degradation causing performance limiting concerns. Because of the technological and economic impacts of oxidation, understanding early-stage oxidation growth and its mechanisms is of high importance. Unfortunately, poor empirical data during early-stage oxidation has left our current understanding of oxidation incomplete and woefully inadequate. Measurement techniques previously used for oxidation kinetics characterization include microbalance, x-ray diffraction, Fourier-transform infrared spectroscopy, and spectroscopic ellipsometry. However, these techniques lack the necessary time-resolution or vertical resolution in addition to not providing any spatial data, which is essential to early-stage oxidation studies to understand both oxidation kinetics and mechanisms. Here, a novel rapid and surface-sensitive data collection technique that provides three-dimensional spatial data of a growing oxide layer with sub-nanometer thickness resolution using white-light interferometry has been developed. This technique will be the first technique capable of providing real-time spatial results of early-stage oxidation growth. The effectiveness of this characterization tool is shown by observing the early-stage oxidation kinetics and film cracking of uranium heated to 90 °C under 500 torr of pure O 2 . Initially a parabolic oxidation growth is observed. Once the oxide layer reaches ≈ 30 nm, the epitaxial stresses between the uranium substrate and oxide film layer causes localized cracking in addition to the observed transition of the parabolic growth rate to a linear growth rate. The results of the white-light interferometry are verified by glancing incidence x-ray diffraction.

47 OTHER INSTRUMENTATION↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

SFAI and Related Technologies

Researchers at Los Alamos have developed Swept-Frequency Acoustic Interferometry (SFAI) a technology that enables businesses to have greater control over their industrial processes, allowing for significantly improved efficiency by giving operators vital composition and flow rate information in real-time. This technology fills the information gap by providing this data non-invasively and at a fraction of the cost of traditional composition meters. SFAI uses engineered ultrasound and advanced signal processing to characterize multiphase flow (e.g., liquids, gasses, multi-phase mixtures) and other flows inside sealed containers and flow pipes. By being both low-cost and non-invasive, this technology is set to disrupt the current oil field monitoring state-of-the-art by providing individual well-level composition data, compared to the multi-well macroscopic information that is currently available. We are seeking a commercialization partner to license the technology or fund us through a Cooperative Research and Development Agreement (CRADA) to a further develop a usable product for commercial purposes.

03 NATURAL GAS↗

Measurement of 2D density profiles using a second-harmonic, dispersion interferometer

A second-harmonic, dispersion interferometer is used to image large-area (≃5 cm 2 ) plasma-jet and gas-jet density profiles. Achromatic telescopes magnify the diameters of the primary-laser beam (1064 nm) and its second-harmonic (532 nm) before probing the sample and de-magnify the beam diameters after the sample, where the primary beam transfers its phase change to a second, second-harmonic beam, allowing the sample’s dispersive-phase change to be measured between two, orthogonally polarized second harmonic beams. The telescopes produce an azimuthally symmetric, dispersive-phase shift in the sample + background phase-change image and in the background phase-change image, which is removed by digital subtraction. The interferometer’s performance was verified using standard-optical components as dispersive elements (BK7 lenses and wedge plates), resolving a minimum, phase-change sensitivity of ΔΦ min ≳ 15 mrad and spatial resolution of Δx res ≃ 100 μm. The phase change produced by unknown-density objects (a pulsed-plasma-jet and a pulsed-gas-jet) was measured, and their data were used to recover the original, 2D density profiles using an inverse Abel transform: peak-number density, N gas ≃ 6 × 10 20 cm –3 and N e ≃ 5 × 10 16 cm –3 ; line-integrated density, ∫N gas dl ~ 2 × 10 19 cm –2 and ∫N e dl ~ 1 × 10 16 cm –2 . The techniques and methods developed here are scalable to even larger probe-beam diameters and frame-capture rates, leading to a diagnostic capability that is well-suited for applications involving the real-time measurement of density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast temporal phase-resolved nonlinear optical spectroscopy in the molecular frame

In an ultrafast nonlinear optical interaction, the electric field of the emitted nonlinear signal provides direct access to the induced nonlinear transient polarization or transient currents and thus carries signatures of ultrafast dynamics in a medium. Measurement of the electric field of such signals offers sensitive observables to track ultrafast electron dynamics in various systems. In this work, we resolve the real-time phase of the electric field of a femtosecond third-order nonlinear optical signal in the molecular frame. The electric field emitted from impulsively pre-aligned gas-phase molecules at room temperature, in a degenerate four-wave mixing scheme, is measured using a spectral interferometry technique. The nonlinear signal is measured around a rotational revival to extract its molecular-frame angle dependence from pump-probe time-delay scans. By comparing these measurements for two linear molecules, carbon dioxide and nitrogen, we show that the measured second-order phase parameter (temporal chirp) of the signal is sensitive to the valence electronic symmetry of the molecules, whereas the amplitude of the signal does not show such sensitivity. We compare measurements to theoretical calculations of the chirp observable in the molecular frame. This work is an important step towards using electric field measurements in nonlinear optical spectroscopy to study ultrafast dynamics of electronically excited molecules in the molecular frame.

47 OTHER INSTRUMENTATION↗

Leveraging FPGA Advantages for Quicker Data Processing for LBNF

The Long Baseline Neutrino Facility (LBNF) will deliver a 2.4 MW muon neutrino beam from Fermilab to the Deep Underground Neutrino Experiment (DUNE), requiring unprecedented precision in beamline alignment to achieve DUNE's neutrino oscillation measurement goals. Vertical misalignments of beamline components as small as 0.5 mm can contribute 6-7\% uncertainty in predicted neutrino flux, necessitating sub-0.1 mm alignment monitoring capabilities. The Horn Location Sensor (HLS) system employs frequency sweep interferometry (FSI) in a distributed hydrostatic leveling network to achieve the required precision under harsh radiation conditions up to 5000 kRad/year. Traditional FSI implementations suffer from laser sweep nonlinearities that degrade resolution and require computationally intensive post-processing corrections using gas reference cells. This work presents a real-time FPGA-based implementation of the HLS data acquisition and processing system using a sweep tracker interferometer for dynamic sweep linearization. The system utilizes a PYNQ-Z2 FPGA with programmable logic implementing parallel 16k-point FFT processing across four channels, synchronized by the sweep tracker signal to eliminate post-processing requirements. Spectral performance testing demonstrates significant improvements in peak sharpness compared to traditional fixed-frequency digitization. The FPGA implementation enables real-time displacement monitoring with processing speeds orders of magnitude faster than software-based approaches, essential for the operational requirements of LBNF's eventual distributed sensor network. This advancement in real-time FSI processing directly supports DUNE's precision neutrino physics program by providing the rapid feedback necessary for maintaining stringent beamline alignment tolerances during high-power beam operations.

Rossel, Jacob↗

Prototype design and experimental tests of a zoom mirror system for the APS upgrade

Mirror-based zoom optics systems can offer variable focal spot sizes over a wide range, which is essential for coherent nanoprobe beamlines, such as the proposed Atomic beamline in the Advanced Photon Source (APS) upgrade project. The success of the zoom mirror system in the nano-focusing regime requires the development of high-precision deformable mirrors, in-situ surface profilers and wavefront sensors, and advanced feedback control system. A prototype 1-D zoom mirror system consists of two vertical focusing mirrors was designed, assembled, and tested at the APS 1-BM beamline. The system consists of a bender-based mirror with a capacitive-sensorarray-based real-time mirror profiler, a bimorph adaptive mirror, and a grating interferometer for the wavefront monitoring. In this work, we present the design and test results of the prototype system demonstrating its zoom focusing capability.

adaptive optics↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Microscopic changes governing melting anisotropy: Real-time nanosecond x-ray diffraction

To understand the microscopic origins governing melting anisotropy, in-situ x-ray diffraction (XRD) measurements were obtained in aluminum single crystals shocked along $\langle$100$\rangle$ and $\langle$110$\rangle$ to stresses below and above the melting threshold for each orientation. XRD results and analysis for the two orientations showed significant differences in the microstructure prior to the melting threshold stresses, demonstrating the key role of deformation induced microstructure – in addition to temperature and pressure – on the melting transition. As a result, our findings make a strong case for reconsidering theoretical approaches to melting, specifically for dislocation mediated melting, in shock compressed solids.

crystal melting↗

Distributed optical fibre sensing in physical oceanography: emergence and future prospects

Distributed optical fibre sensing (DOFS) is a technology that enables continuous, real-time measurements of a range of environmental parameters along the length of a fibre optic cable. In this article, we review the recently emerged applications of DOFS techniques in physical oceanography and offer a perspective on the technology's potential for future growth within the field. The introduction of DOFS to physical oceanography is contextualised with a brief history of the technology, which spun off primarily from the use of seafloor-laid optical fibres for telecommunications purposes. The key components and underpinning physics of a DOFS system are outlined and, on their basis, the suite of variables that are observable with DOFS are discussed. The implementation factors of DOFS, which include trade-offs between measurement accuracy and spatio-temporal resolutions and ranges, are also examined. The physical oceanographic applications of DOFS to date are then illustrated with case examples of four distinct DOFS techniques: distributed temperature sensing (DTS), which can provide ocean temperature observations; distributed static strain sensing (DSS) and distributed acoustic sensing (DAS), which are sensitive to temperature, cable strain and strain-associated variables, such as pressure and ocean velocity; and ultra-long-range observations of ocean currents with optical interferometry. The forthcoming prospects of DOFS in physical oceanography are considered, and are proposed to include new fibre optic-based approaches to sense ocean salinity and measure through the water column. We conclude with reflections on the future role of DOFS within the Global Ocean Observing System, and highlight the opportunities provided by the existing world-wide network of seafloor-laid optical fibres.

Naveira Garabato, Alberto C. [Univ. of Southampton↗

Simultaneous measurements of volume, pressure, optical images, and crystal structure with a dynamic diamond anvil cell: A real-time event monitoring system

The dynamic diamond anvil cell (dDAC) technique has attracted great interest because it possibly provides a bridge between static and dynamic compression studies with fast, repeatable, and controllable compression rates. The dDAC can be a particularly useful tool to study the pathways and kinetics of phase transitions under dynamic pressurization if simultaneous measurements of physical quantities are possible as a function of time. We report the development of a real-time event monitoring (RTEM) system with dDAC, which can simultaneously record the volume, pressure, optical image, and structure of materials during dynamic compression runs. In particular, the volume measurement using both Fabry–Pérot interferogram and optical images facilitates the construction of an equation of state (EoS) using the dDAC in a home-laboratory. We also developed an in-line ruby pressure measurement (IRPM) system to be deployed at a synchrotron x-ray facility. This system provides simultaneous measurements of pressure and x-ray diffraction in low and narrow pressure ranges. The EoSs of ice VI obtained from the RTEM and the x-ray diffraction data with the IRPM are consistent with each other. The complementarity of both RTEM and IRPM systems will provide a great opportunity to scrutinize the detailed kinetic pathways of phase transitions using dDAC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗