At least 19 records

Development of a military-specific mesh-type computational phantom library and its application to internal dosimetry and in-field radiological triage screening

Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.

computational phantoms↗

Stochastic parametric skeletal dosimetry model for humans: Pediatric and adult computational skeleton phantoms for internal bone marrow dosimetry

Currently, computational phantoms that simulate skeletal tissues are used in active red bone marrow (AM) internal dosimetry. Up-to-date reference computational phantoms recommended by the ICRP are based on the analysis of CT-images of cadavers. Such phantoms have significant disadvantages. One disadvantage is that the assessment of uncertainty due to the population variability of skeleton dimensions and microstructure results from the limited availability of autopsy material. Another disadvantage is the simplified modelling of cortical layer and bone microarchitecture. A method of stochastic parametric skeletal dosimetry modelling of the bone structures – SPSD modelling – has been developed as an alternative to the ICRP reference phantoms. In the framework of this approach, skeletal phantom parameters are evaluated based on extensively reviewed results of published measurements of real bones. The SPSD approach allows for the assessment of both population-average values and their variability. SPSD-phantoms of the skeleton are modelled in voxel representation. They consist of smaller phantoms of the bone sites – segments – described by simple geometric shapes with uniform microarchitecture parameters. Such segmentation makes it possible to account for non-homogeneous skeletal microarchitecture and to model the bone structure with the required voxel resolution to elaborate suitable skeletal phantoms. The current study presents the parameters of the SPSD skeletal phantoms for the following age-groups: newborn, 1-year-old, 5-year-old, 10-year-old, 15-year-old (male and female), and adult (male and female). This skeletal phantom can be used for dosimetry as an alternative to available reference phantoms for bone-seeking radionuclides. The above-mentioned age- and sex-specific skeletal phantoms are comprised of 289 unique segments. The characteristics of the SPSD phantoms do not contradict published data and are in good agreement with the measurement results of real bones.

Science & Technology - Other Topics↗

RCT: Module 2.07 Respiratory Protection [Slides]

Internal dosimetry controls require the use of engineering controls to prevent the internal deposition of radioactive and non-radiological contaminants. However, when engineering and administrative controls are not available or feasible, respiratory protection may be necessary. The RCT should know and apply the considerations used in determining the respiratory protection equipment that is most appropriate for the job. The inappropriate use of or the use of the wrong respiratory protection equipment may result in undesirable health effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Re-evaluating the prompt fission neutron spectrum of spontaneously fissioning 252 Cf

The prompt fission neutron spectrum (PFNS) of spontaneously fissioning 252 Cf is a Neutron Data Standards observable. Nearly all fission spectra of actinides were measured relative to it, using efficiencies derived from it, or analyzed with simulations validated by it. The current Standards evaluation was published by W. Mannhart in 1987. It could not be updated because the evaluation input, experimental mean values and covariances, were lost. First, we attempt to reproduce it. However, Mannhart’s evaluation can only be reproduced within its one-σ uncertainties as some of its aspects (e.g., experimental covariances, rejected data points) remain unknown. Therefore, a new evaluation is presented: We revisit all existing experimental 252 Cf(sf) PFNS data, including those published after the release of the current Standards evaluation, and re-estimate associated covariances. The newly evaluated 252 Cf(sf) PFNS differs distinctly from Mannhart’s below 300 keV and extends it to lower and higher outgoing neutron energies (500 eV–25 MeV). The new evaluated uncertainties are larger from 3–9 MeV and smaller otherwise. Spectrum averaged cross sections of importance to the International Reactor Dosimetry and Fusion File community calculated with the new spectrum are close to those calculated with Mannhart’s evaluation and agree with experimental values well within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing secondary neutrons at BLIP for isotope production applications

Fast secondary neutrons created at the Brookhaven Linac Isotope Producer (BLIP) facility following proton irradiation were characterized by the foil activation technique and compared with FLUKA Monte Carlo simulations. The FLUKA-simulated neutron flux was spectrally adjusted following the maximum entropy formalism using the International Reactor Dosimetry and Fusion File (IRDFF-II), with predictions agreeing with experimental measurements to within 9 % following the adjustment procedure. Here, a multitude of degrader configurations were simulated to assess the feasibility of improving the fast (E n > 20 MeV) secondary neutron yield at the proposed neutron target position (“N-slot”). A configuration where the N-slot is closest to the proton degrader produced the highest fast neutron yield, with tungsten degraders achieving the best performance. Assuming the optimized target-degrader configuration proposed in this work, we discuss potential isotope production opportunities with secondary neutrons. In most cases the yields are in the order of several mCi.

07 ISOTOPE AND RADIATION SOURCES↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Current Active Detectors for Dosimetry and Spectrometry on the International Space Station

We present a high-level overview of two of the most important radiation detection systems currently flying aboard the International Space Station(ISS), ISS-RAD and Timepix. ISS-RAD is a single, large unit that is capable of detecting both chargedand neutral high-energy particles. For most of its first three and a half years of operations onboard Station, ISS-RAD has been periodically moved to different modules, includingtheUSLab, Columbus, JEM, Node2, and Node3. In contrast, the much smaller Timepix-based detectors are deployed in several locations around the station. The first generation of these units were known as REMs, or Radiation Environment Monitors. A second generation has recently been deployed, known as REM-2 units. We will briefly describe the technologies used in these systems and their capabilities.

Cary Zeitlin↗

Passive dosimetry aboard the Mir Orbital Station: internal measurements

Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

NASA Experiment Number 9401620↗

Initial Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute's TRIGA Reactor

This report presents the initial results for IER-602, the international nuclear accident dosimetry intercomparison performed at the Armed Forces Radiobiology Research Institute (AFRRI). Ten groups participated (six DOE laboratories, three international groups, and one DOD group) in a week-long exercise in late June 2024. Two additional groups observed the exercise (one DOE laboratory, one university). Three days of irradiations were performed, and participants reported results within 24 hours of the irradiations. Results were compared to the reference values and performance criteria established by IER-484 AFRRI ER1 Dosimetry Characterization and ANSI/HPS N13.3-2013, respectively. Passing performance varied from 17% to 100%, with an average of 67%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experiment Logistics for an International Blind Intercomparison Exercise for Nuclear Accident Dosimetry at the Armed Forces Radiobiology Research Institute's TRIGA Reactor

This document is the Experimental Set-up and Design (CED-3a) Report for IER-602, “Dosimetry Exercise with Armed Forces Radiobiology Research Institute (AFRRI) - Exercise” The report discusses the structure of the exercise consisting of three reactor exposures, identifying the participating laboratories and their points of contact. The report also includes details of all dosimetry each laboratory will submit to be placed in proximity to AFRRI on aluminum plates or BOMAB phantoms. Each laboratory lists the counting and spectroscopy equipment to be utilized at AFFRI. The exercise is tentatively scheduled for one week in June, 2024 (FY24 Q4).

42 ENGINEERING↗

USF/Russian dosimetry on STS-57

The major purpose of this experiment was to conduct an international comparison of passive dosimetry methods in space. Two APD's were flown in the charged particle directional spectrometer (CPDS)/tissue equivalent proportional counter (TEPC) locker on the space shuttle during the STS-57 mission. Due to placement, the shielding and radiation environment of the APD's were nearly the same and the dosimeters distributed in the two boxes can be considered equally exposed. The dosimeter types included plastic nuclear track detectors (PNTD's), thermoluminescent detectors (TLD), nuclear emulsions, and thermal/resonance neutron detectors (TRND's). The USF dosimeters included PNTD's, TLD's, and TRND's, while the Russian dosimeters included PNTD's, TLD's, and nuclear emulsions.

Source record↗

Universal Nuclear Accident Dosimeter

The Lawrence Livermore National Laboratory (LLNL) Universal Nuclear Accident Dosimetry (UNAD) project is a four-year initiative aimed at advancing nuclear accident dosimetry methods. This article presents an overview of the research, key findings, and the progress made throughout the project. The primary goals included a background into the history of nuclear accident dosimetry, consolidating current dosimetry techniques within the NNSA/DOE complex, fostering collaboration among subject matter experts, and exploring novel technologies for potential implementation. The technical focus centered on investigating new and novel technologies, instrumentation methods, and analysis methods to develop recommendations for a potential nuclear accident dosimeter (NAD) to be universally deployed through the DOE complex. A multilaboratory and multinational Usergroup was established, conducting periodic meetings to facilitate knowledge exchange. The UNAD team has participated in two international nuclear accident dosimetry intercomparison exercises and one characterization exercise, where the existing LLNL NAD and a prototype alanine electron paramagnetic dosimeter NAD were deployed. Ongoing improvements are being made to the prototype NAD based on results from the exercises, laboratory studies, and collaboration with other laboratories. A machine learning algorithm to optimize the geometry and conversion factors of the current LLNL NAD is being implemented, and the resulting design will be tested in the next exercise. In conclusion, key lessons learned and future directions for the project are discussed.

Electron paramagnetic resonance spectroscopy↗