Search NASA⌕ Search

SEARCH · Search NASA

Results for “internal dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Current Active Detectors for Dosimetry and Spectrometry on the International Space Station

We present a high-level overview of two of the most important radiation detection systems currently flying aboard the International Space Station(ISS), ISS-RAD and Timepix. ISS-RAD is a single, large unit that is capable of detecting both chargedand neutral high-energy particles. For most of its first three and a half years of operations onboard Station, ISS-RAD has been periodically moved to different modules, includingtheUSLab, Columbus, JEM, Node2, and Node3. In contrast, the much smaller Timepix-based detectors are deployed in several locations around the station. The first generation of these units were known as REMs, or Radiation Environment Monitors. A second generation has recently been deployed, known as REM-2 units. We will briefly describe the technologies used in these systems and their capabilities.

Cary Zeitlin↗

Passive dosimetry aboard the Mir Orbital Station: internal measurements

Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

NASA Experiment Number 9401620↗

USF/Russian dosimetry on STS-57

The major purpose of this experiment was to conduct an international comparison of passive dosimetry methods in space. Two APD's were flown in the charged particle directional spectrometer (CPDS)/tissue equivalent proportional counter (TEPC) locker on the space shuttle during the STS-57 mission. Due to placement, the shielding and radiation environment of the APD's were nearly the same and the dosimeters distributed in the two boxes can be considered equally exposed. The dosimeter types included plastic nuclear track detectors (PNTD's), thermoluminescent detectors (TLD), nuclear emulsions, and thermal/resonance neutron detectors (TRND's). The USF dosimeters included PNTD's, TLD's, and TRND's, while the Russian dosimeters included PNTD's, TLD's, and nuclear emulsions.

Source record↗

NASA GeneLab Platform Utilized for Space Radiation Dosimetry Biological Response Compared to Radiation Ground Studies

Ionizing radiation from Galactic Cosmic Rays (GCR) is one of the major risk factors factor that will impact health of astronauts on extended missions outside the protective effects of the Earth's magnetic field. Currently there are gaps in our knowledge of the health risks associated with chronic low dose, low dose rate ionizing radiation, specifically ions associated with high (H) atomic number (Z) and energy (E). The NASA GeneLab project (genelab.nasa.gov) aims to provide a detailed library of Omics datasets associated with biological samples exposed to HZE. The GeneLab Data System (GLDS) includes datasets from both spaceflight and ground-based studies, a majority of which involved exposure to ionizing radiation. Recently GeneLab has also assessed radiation dosimetry data with omics datasets associated with samples flown to the International Space Station (ISS). The combination of the detailed information on radiation exposure for ground-based studies and curated dosimetry information for spaceflight experiments allows GeneLab to be the first comprehensive Omics database for space related research from which an investigator can generate hypotheses to direct future experiments utilizing both ground and space biological radiation data. We demonstrate the usefulness of these datasets by analyzing multiple GeneLab datasets associated with both radiation ground-based studies and spaceflight studies. The radiation ground based studies we analyzed includes both in vivo and in vitro work with a range ions from protons to iron particles with doses from 0.1Gy to 2Gy. These datasets were compared to both in vivo and in vitro datasets from samples flown to the ISS and on shorter shuttle missions with total doses of 0.1 mGy to 30 mGys. From this analysis we were able to associate distinct biological signatures associating specific ions to specific biological response to radiation exposure in space. For example, we discovered radiation biological response related to cardiovascular effects from proton ground studies are the dominating response for samples related to cardiovascular effects on the ISS. With this work we will provide a summary of how different ions will impact different biological response in space and how this can be used in future studies to assess optimal ground experiments to simulate space radiation.

Beheshti, Afshin↗

RadLab: Graphical and Programming Interfaces for Interrogation of Space Telemetry Data

Sensors on multiple spacecraft in and beyond low Earth orbit continuously monitor and collect space radiation data and transmit it back to Earth. These data are of vast importance to space biology research, as ionizing radiation affects living organisms—astronauts and non-human experiment subjects alike—placing them at higher risk of carcinogenesis, degenerative diseases, and radiation sickness. Therefore, knowledge of the biological effects of space radiation is essential for planning future crewed missions beyond low Earth orbit. The RadLab project, initiated by GeneLab and ALSDA (the Open Science Data Repository; OSDR) and sponsored by the NASA Human Research Program, is a new effort aimed at connecting dosimetry data from radiation detectors located on the International Space Station (ISS), as well as other spacecraft. To date, access to these data has been fragmented across space agencies and databases; to address this issue, we have developed an application programming interface (API) and an associated graphical user interface (GUI) designed to provide a single point of access to the data. As of now, OSDR has focused on the detectors located on the ISS, with the long-term goal to establish a self-sustained portal receiving continuous updates through APIs connecting to multiple radiation databases of varying scope, as well as individual investigator contributions. The RadLab API implements a request syntax enabling users to query data by craft, sensor type, timespan, etc, allowing for arbitrary combinations of original source data, thus providing programmatic access for use in computational pipelines, while the GUI facilitates data visualization and exploration, making these data FAIR (Findable, Accessible, Interoperable, and Reusable), complementing the biological data contained in OSDR, and providing the space science community with a valuable resource for scientific analyses.

radiation↗

NASA GeneLab: Open Science for Life in Space

The NASA GeneLab project capitalizes on multi-omic technologies to maximize the return on spaceflight experiments. To do this, GeneLab maintains a publicly accessible database (GLDS) that houses spaceflight and spaceflight relevant multi-omics data and collaborates with NASA principal investigators and projects to generate additional omics data. GeneLab houses more than 350 transcriptomic, proteomic, metabolomic and epigenomic datasets from plant, animal and microbial experiments, with a growing number of these having been produced by the GeneLab Sequencing Lab. The GLDS contains rich metadata about each experiment and has integrated radiation dosimetry data from experiments flown on the Space Shuttle, International Space Station, and Free Flying spacecrafts. With the increasing amount and complexity of omics data being generated, GeneLab utilizes community-defined, common models for metadata and terminology so that omics data and results are discoverable and reliably reproducible. GeneLab uses the ISA-Tab specification and semantic model for organizing and representing omics metadata. In addition to metadata standards, data files must be open-source file or common exchange formats to ensure accessibility and usability by all users. To ease data ingestion and transfer, the web-based submission tool allows PIs a user-friendly user interface to curate, organize, and publish their space relevant omics data. In the more recent years, data curation and submission portal has incorporated the FAIR principles making data findable, accessible, interoperable, and reusable. To increase reusability of data, GeneLab has implemented an effort to present processed data in the GLDS in addition to the raw omics data. The processed data will enable interpretation of the data by a larger group of students, scientists and the general public. Standard pipelines for the transformation of raw data into visualizations were developed by four GeneLab Analysis Working Groups (animals, plants, microbes, multi-omics) comprised of over 200 scientists from NASA, industry, and academia. To explore the data, the GLDS provides users various tools for data analysis, collaborative workspace for file storage and sharing, and a visualization portal. The analysis platform built using the Galaxy toolshed provides access to a broad variety of users including those with limited bioinformatics experience and students to learn how to analyze spaceflight omics data. The visualization portal takes GeneLab one step closer to data democratization by removing all bioinformatics requisites to interpret transcriptomics data hosted in the repository. To train the next generation of scientists, NASA offers training programs such as GeneLab 4 High School (GL4HS) and GeneLab 4 Universities. NLM Curation at a Scale Workshop 2022 | NASA GeneLab (GL4U) to teach students bioinformatics and computational biology methods to analyze omics data. Discoveries made using GeneLab have begun and will continue to deepen our understanding of biology, advance the field of genomics, and help to discover cures for diseases, create better diagnostic tools, and ultimately allow astronauts to better withstand the rigors of long-duration spaceflight.

GeneLab↗

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned↗

Measurement of LET distribution and dose equivalent on board the space shuttle STS-65

Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.

manned↗

Genetic and molecular dosimetry of HZE radiation (US-1 RADIAT)

In order to estimate radiation exposure in space, experiments were conducted during the 1st International Microgravity Laboratory (IML-1) mission in order to isolate genetic changes in animal cells caused by cosmic rays. The space measurements were evaluated against results from synthetic cosmic rays produced by particle accelerators on the ground. The biological material used was the tiny soil nematode, Caenorhabditis elegans. The measurements were made by thermoluminescent detectors and plastic nuclear track detectors. The development and the chromosome mechanics in microgravity were studied, and the mutagenesis induced by radiation exposure was analyzed. The results showed that there are no obvious differences in the development, behavior and chromosome mechanics, as a function of gravity unloading (reproduction, self-fertilization and mating of males with hermaphrodites, gross anatomy, symmetry and gametogenesis, pairing, disjoining and recombination of chromosomes). A variety of mutants were isolated, and it was noted that mutants isolated from regions of identified high particles were more severely affected than those isolated by random screening. Linear energy transfer particles seem to favor large scale genetic lesions.

Nelson, Gregory A.↗

The ALTEA/ALTEINO projects: studying functional effects of microgravity and cosmic radiation

The ALTEA project investigates the risks of functional brain damage induced by particle radiation in space. A modular facility (the ALTEA facility) is being implemented and will be operated in the International Space Station (ISS) to record electrophysiological and behavioral descriptors of brain function and to monitor their time dynamics and correlation with particles and space environment. The focus of the program will be on abnormal visual perceptions (often reported as "light flashes" by astronauts) and the impact on retinal and brain visual structures of particle in microgravity conditions. The facility will be made available to the international scientific community for human neurophysiological, electrophysiological and psychophysics experiments, studies on particle fluxes, and dosimetry. A precursor of ALTEA (the 'Alteino' project) helps set the experimental baseline for the ALTEA experiments, while providing novel information on the radiation environment onboard the ISS and on the brain electrophysiology of the astronauts during orbital flights. Alteino was flown to the ISS on the Soyuz TM34 as part of mission Marco Polo. Controlled ground experiments using mice and accelerator beams complete the experimental strategy of ALTEA. We present here the status of progress of the ALTEA project and preliminary results of the Alteino study on brain dynamics, particle fluxes and abnormal visual perceptions. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

manned↗

NASA GeneLab Space Omics Database: Expanding from Space to Ionizing Radiation Data on the Ground

NASA GeneLab is an open-access repository for omics datasets generated by biological experiments conducted in space or ground experiments relevant to spaceflight (e.g. simulated cosmic radiation, simulated microgravity, bed rest studies). The GeneLab Data Systems (GLDS) version 4.0 will be available on October 1st 2019, and will provide a state-of-the-art bioinformatics platform for the space biology and radiation communities to upload their data into an omics data commons, to process their data with vetted standard workflows and to compare with existing analyses. Started in 2015 as a repository designed to archive omics data from space experiments, GeneLab has expanded its scope to all ionizing radiation omics experiments conducted on the ground and has put considerable effort in providing carefully characterized radiation metadata on all datasets. GeneLab is also providing processed data derived from the raw data covering a large spectrum of omics (genome, epigenome, transcriptome, epitranscriptome, proteome, metabolome) to help users explore important questions: 1) Which genes or proteins are expressed differently in space for various living organisms? 2) What specific DNA mutations or epigenetic changes happen in space or after exposure to ionizing radiation? and 3) How does genetics affect these responses? Processed data available on GeneLab are derived by standard data analysis workflows vetted by hundreds of scientists who volunteered to join one of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). In this presentation, we will discuss how to bridge the gap between irradiation studies performed on earth and biological experiments conducted in space since the early 1990's. We will discuss how radiation dosimetry was estimated for datasets derived from samples collected during the Space Shuttle era on the International Space Station and on other orbiting platforms. Finally, we will address future strategies regarding dose monitoring in future missions into space, inter-agency efforts to unify data under one umbrella, and knowledge dissemination across the radiation research community and the space biology community.

open-science↗

GeneLab: A Systems Biology Platform for Omics Analysis

NASA GeneLab is an open-access repository for omics datasets generated by biological experiments conducted in space or experiments relevant to spaceflight (e.g. simulated cosmic radiation, simulated microgravity, bed rest studies). The GeneLab Data Systems (GLDS) version 4.0 will be available on October 1st 2019, and will provide the latest in terms of professional state-of-the-art bioinformatics platform for the space biology and radiation community to upload their data into an omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. Started in 2015 as a repository designed to archive omics data from space experiments, GeneLab has expanded its scope to all ionizing radiation omics experiments conducted on the ground and has put considerable effort in providing carefully characterized radiation metadata on all dataset. GeneLab is also providing processed data derived from the raw data covering a large spectrum of omics (genome, epigenome, transcriptome, epitranscriptome, proteome, metabolome) to help users explore important questions: 1) Which genes or proteins are expressed differently in space for various living organisms? 2) What specific DNA mutations or epigenetic changes happen in space or after exposure to ionizing radiation? and 3) How does genetics affect these responses? Processed data available on GeneLab are derived by standard data analysis workflows vetted by hundreds of scientists who volunteered to join one of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). In this presentation, we will discuss how to bridge the gap between irradiation studies performed on earth and biological experiments conducted in space since the early 1990's. We will discuss how radiation dosimetry was estimated for datasets derived from samples collected during the Space Shuttle era or on the International Space Station. Finally, we will address future strategies regarding dose monitoring in future missions into space, inter-agency efforts to unify data under one umbrella, and knowledge dissemination across the radiation research community and the space biology community.

open-science↗

Advanced dosimetry systems for the space transport and space station

Advanced dosimetry system concepts are described that will provide automated and instantaneous measurement of dose and particle spectra. Systems are proposed for measuring dose rate from cosmic radiation background to greater than 3600 rads/hr. Charged particle spectrometers, both internal and external to the spacecraft, are described for determining mixed field energy spectra and particle fluxes for both real time onboard and ground-based computer evaluation of the radiation hazard. Automated passive dosimetry systems consisting of thermoluminescent dosimeters and activation techniques are proposed for recording the dose levels for twelve or more crew members. This system will allow automatic onboard readout and data storage of the accumulated dose and can be transmitted to ground after readout or data records recovered with each crew rotation.

Wailly, L. F.↗

Status - International Space Station (ISS) Crewmembers' Noise Exposures

Environmental noise in space vehicles, caused by onboard equipment and crew activities, has generated concerns for crew health and safety since early U.S. space missions. The International Space Station (ISS) provides a unique environment where acoustic conditions can be monitored while crewmembers from the U.S. and their international partners work and live for as long as 6 to 12 consecutive months. This review of acoustic dosimetry data collected to date reveals that the noise exposure limits of NASA’s stringent noise constraint flight rule have been exceeded in 41% of these dosimetry measurements since ISS Increment 17 (2008), with undefined impacts to crew. These measurements do not take into account the effects of hearing protection devices worn by the crew. The purpose of this paper is to provide an update on ISS noise exposure monitoring approaches and hearing conservation strategies that include acoustic dosimetry data collected since the ISS Increment 55 mission (April 2018). Future directions and recommendations for the ISS noise exposure monitoring program will also be presented, including research initiatives aimed at better defining the impact of ISS noise on crew health and performance.

Jose G Limardo↗

Status - International Space Station (ISS) Crewmembers' Noise Exposures

Environmental noise in space vehicles caused by onboard equipment and noisy activities has generated concerns for crew health and safety since early U.S. space missions. The International Space Station (ISS) provides a unique environment where acoustic conditions can be monitored while crewmembers from the U.S. and their international partners work and live for as long as 6 to 12 consecutive months. This review of acoustic dosimetry data collected to date reveals that the noise exposure limits of NASA’s stringent noise constraint flight rule have been exceeded in 41% of these dosimetry measurements since ISS Increment 17 (2008), with undefined impacts to crew. These measurements do not take into account the effects of hearing protection devices worn by the crew. The purpose of this paper is to provide an update on ISS noise exposure monitoring approaches and hearing conservation strategies that include acoustic dosimetry data collected since the ISS Increment 55 mission (April 2018). Future directions and recommendations for the ISS noise exposure monitoring program will also be presented, including research initiatives aimed at better defining the impact of ISS noise on crew health and performance.

Jose G Limardo↗

Cytogenetic Biodosimetry Using the Blood Lymphocytes of Astronauts

Cytogenetic analysis of blood lymphocytes remains the most sensitive and reliable method available for in vivo assessment of the biological effects of exposure to radiation and provides the most informative measurement of radiation induced health risks. To date chromosome damage has been assessed in lymphocytes from more than 30 astronauts before and after they participated in long-duration space missions of three months or more on board the International Space Station. For all individuals, the frequency of chromosome damage measured within a month of return from space was higher than their prefight yield and biodosimetry estimates lie within the range expected from physical dosimetry. Biodosimetry data provides a direct measurement of space radiation damage, which takes into account individual radiosensitivity in the presence of confounding factors such as microgravity and other stress conditions. In contrast to physical measurements, which are external to body and require multiple devices to detect all radiation types all of which have poor sensitivity to neutrons, biodosimetry is internal and includes the effects of shielding provided by the body itself plus chromosome damage shows excellent sensitivity to protons, heavy ions, and neutrons. In addition, chromosome damage is reflective of cancer risk and biodosimetry values can therefore be used to validate and develop risk assessment models that can be used to characterize excess health risk incurred by crewmembers. A review of astronaut biodosimetry data will be presented along with recent findings on the persistence of space radiation induced chromosome damage and the cytogenetic effects of repeat long duration missions

George, Kerry↗

Depth Dose Distribution Study within a Phantom Torso after Irradiation with a Simulated Solar Particle Event at NSRL

The adequate knowledge of the radiation environment and the doses incurred during a space mission is essential for estimating an astronaut's health risk. The space radiation environment is complex and variable, and exposures inside the spacecraft and the astronaut's body are compounded by the interactions of the primary particles with the atoms of the structural materials and with the body itself Astronauts' radiation exposures are measured by means of personal dosimetry, but there remains substantial uncertainty associated with the computational extrapolation of skin dose to organ dose, which can lead to over- or underestimation of the health risk. Comparisons of models to data showed that the astronaut's Effective dose (E) can be predicted to within about a +10% accuracy using space radiation transport models for galactic cosmic rays (GCR) and trapped radiation behind shielding. However for solar particle event (SPE) with steep energy spectra and for extra-vehicular activities on the surface of the moon where only tissue shielding is present, transport models predict that there are large differences in model assumptions in projecting organ doses. Therefore experimental verification of SPE induced organ doses may be crucial for the design of lunar missions. In the research experiment "Depth dose distribution study within a phantom torso" at the NASA Space Radiation Laboratory (NSRL) at BNL, Brookhaven, USA the large 1972 SPE spectrum was simulated using seven different proton energies from 50 up to 450 MeV. A phantom torso constructed of natural bones and realistic distributions of human tissue equivalent materials, which is comparable to the torso of the MATROSHKA phantom currently on the ISS, was equipped with a comprehensive set of thermoluminescence detectors and human cells. The detectors are applied to assess the depth dose distribution and radiation transport codes (e.g. GEANT4) are used to assess the radiation field and interactions of the radiation field with the phantom torso. Lymphocyte cells are strategically embedded at selected locations at the skin and internal organs and are processed after irradiation to assess the effects of shielding on the yield of chromosome damage. The initial focus of the present experiment is to correlate biological results with physical dosimetry measurements in the phantom torso. Further on, the results of the passive dosimetry within the anthropomorphic phantoms represent the best tool to generate reliable data to benchmark computational radiation transport models in a radiation field of interest. The presentation will give first results of the physical dose distribution, the comparison with GEANT4 computer simulations based on a Voxel model of the phantom, and a comparison with the data from the chromosome aberration study.

Berger, Thomas↗

Verification of Dosimetry Measurements with Timepix Pixel Detectors for Space Applications

The current capabilities of modern pixel-detector technology has provided the possibility to design a new generation of radiation monitors. Timepix detectors are semiconductor pixel detectors based on a hybrid configuration. As such, the read-out chip can be used with different types and thicknesses of sensors. For space radiation dosimetry applications, Timepix devices with 300 and 500 microns thick silicon sensors have been used by a collaboration between NASA and University of Houston to explore their performance. For that purpose, an extensive evaluation of the response of Timepix for such applications has been performed. Timepix-based devices were tested in many different environments both at ground-based accelerator facilities such as HIMAC (Heavy Ion Medical Accelerator in Chiba, Japan), and at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory in Upton, NY), as well as in space on board of the International Space Station (ISS). These tests have included a wide range of the particle types and energies, from protons through iron nuclei. The results have been compared both with other devices and theoretical values. This effort has demonstrated that Timepix-based detectors are exceptionally capable at providing accurate dosimetry measurements in this application as verified by the confirming correspondence with the other accepted techniques.

Kroupa, M.↗