Search NASA⌕ Search

SEARCH · Search NASA

Results for “international standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Internal Standards for Quantitative Analysis of Chemical Warfare Agents by the GC/MS Method: Nerve Agents

General conditions and requirements for an internal standard useful in the determination of chemical warfare agents (CWAs) by the method of gas chromatography coupled with mass detection (GC/MS) were defined. The determination is based on a GC/MS analysis of a mixture of a CWA with an internal standard, conversion of the TIC chromatogram to a chromatogram extracted at a particular m / z ratio, and calculation of the CWA concentration from the internal standard concentration, response factor, and chromatographic peak areas. Available internal standards were identified, and they were verified for seven organophosphorus nerve-paralysing agents. Corresponding response factors were determined as a ratio of gradients of the linear functions of the peak area and compound concentration. Linearity, repeatability, and accuracy of the measurements were evaluated. The determination can be performed on all GC/MS systems of the Fire Rescue Service of the Czech Republic (FRS), where no CWA standards are available.

Capoun, Tomas↗

Domestic and International Standards for Nuclear Criticality Safety – Overview and Status

The domestic and international consensus standards for nuclear criticality safety (NCS) have provided guidance for staff performing hands-on work in operations with fissionable materials. These consensus standards have contributed directly to the significant reduction in the rate of criticality accidents in process facilities since the 1940s. The last known criticality accident inside the United States was in 1978 (nearly 43 years ago) at the Idaho Chemical Processing Plant, and outside the United States, an accident occurred at Tokai-mura, Japan, in 1999 (23 years ago). The domestic consensus standards for NCS include the American Nuclear Society (ANS) standards. The ANS Standards Board, the NCS Consensus Committee, and the ANS-8 Subcommittee oversee the development and maintenance of these standards. There are currently eighteen standards in the ANS-8 series. Currently, there are six ANS-8 standards in revision mode and eleven in a maintenance mode with one new standard under development. The international consensus standards for NCS calculations, procedures, and practices are maintained and developed within the International Organization for Standardization (ISO), Technical Committee 85 on Nuclear Energy, Subcommittee 5 on Nuclear Fuel Technology, and Working Group 8, “Nuclear Criticality Safety.” Eleven standards are currently available, three standards are in revision mode, and two standards are development. This paper provides the NCS community with an overview and status report of domestic and international NCS consensus standards to stimulate interest and to support their continued development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Domestic and International Standards for Nuclear Criticality Safety - Overview & Status [Abstract]

The domestic and international consensus standards for nuclear criticality safety (NCS) have provided guidance for staff performing hands-on work in operations with fissionable materials. These consensus standards have contributed directly to the significant reduction in the rate of criticality accidents in process facilities since the 1940s. The last known criticality accident inside the United States was in 1978 (nearly 43 years ago) at the Idaho Chemical Processing Plant, and outside the United States, an accident occurred at Tokai-mura, Japan, in 1999 (22 years ago). The domestic consensus standards for NCS include the American Nuclear Society (ANS) standards. The ANS Standards Board, the NCS Consensus Committee, and the ANS-8 Subcommittee oversee the development and maintenance of these standards. There are currently eighteen standards in the ANS-8 series. Currently, there are six ANS-8 standards in re- vision mode and eleven in a maintenance mode with one new standard under development. The international consensus standards for NCS calculations, procedures, and practices are maintained and developed within the International Organization for Standardization, Technical Committee 85 on Nuclear Energy, Subcommittee 5 on Nuclear Fuel Technology, and Working Group 8, “Nuclear Criticality Safety.” Eleven standards are currently available, three standards are in revision mode, and two standards are development. This paper provides the NCS community with an overview and status report of domestic and international NCS consensus standards to stimulate interest and to support their continued development.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

BSDF Data generation for daylight applications: A call for international standardization

Standardized methods for generating angle-dependent, bidirectional, solar-optical properties for complex fenestration systems do not exist, which means that energy and daylight evaluations in building performance simulations often suffer from major inaccuracies. This position paper provides an overview of state-of-the-art data-driven methods for characterizing light scattering properties of fenestration materials and blind systems (e.g. fabrics, metal slats, patterned glazing), validation via laboratory, simulation and field tests, and salient issues in support of standardization of such methods via the International Standardization Organization (ISO). The ISO standard is intended to provide the fundamental underpinnings for recently mandated daylight standards that rely on bidirectional scattering distribution function data for climate-based daylight modelling and building performance simulations.

Geisler-Moroder, D.↗

Internal Standard Triggered-Parallel Reaction Monitoring Mass Spectrometry Enables Multiplexed Quantification of Candidate Biomarkers in Plasma

Despite advances in proteomic technologies, clinical translation of plasma biomarkers remains low, partly due to a major bottleneck between the discovery of candidate biomarkers and costly clinical validation studies. Due to a dearth of multiplexable assays, generally only a few candidate biomarkers are tested, and the validation success rate is accordingly low. Previously, mass spectrometry-based approaches have been used to fill this gap but feature poor quantitative performance and were generally limited to hundreds of proteins. Here, we demonstrate the capability of an internal standard triggered-parallel reaction monitoring (IS-PRM) assay to greatly expand the numbers of candidates that can be tested with improved quantitative performance. The assay couples immunodepletion and fractionation with IS-PRM and was developed and implemented in human plasma to quantify 5176 peptides representing 1314 breast cancer biomarker candidates. Characterization of the IS-PRM assay demonstrated the precision (median % CV of 7.7%), linearity (median R 2 > 0.999 over 4 orders of magnitude), and sensitivity (median LLOQ < 1 fmol, approximately) to enable rank-ordering of candidate biomarkers for validation studies. Using three plasma pools from breast cancer patients and three control pools, 893 proteins were quantified, of which 162 candidate biomarkers were verified in at least one of the cancer pools and 22 were verified in all three cancer pools. The assay greatly expands capabilities for quantification of large numbers of proteins and is well suited for prioritization of viable candidate biomarkers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Perovskite Photovoltaic Devices with Carbon-Based Electrodes Withstanding Reverse-Bias Voltages up to –9 V and Surpassing IEC 61215:2016 International Standard

One of the key challenges of perovskite photovoltaics (PV) is the long-term stability. Although efforts are made to improve the lifetime of perovskite PV devices, their degradation under reverse-bias conditions is barely addressed. Herein, perovskite solar cells with carbon-based electrodes are presented which demonstrate superior resilience against reverse-bias-induced degradation. Although their breakdown voltage is identified to be at approximately -3.6 V, cells do not degrade until the applied reverse-bias exceeds -9 V. Two main degradation mechanisms are identified: 1) iodine loss due to hole tunneling into perovskite, which takes place even at low reverse-bias but decomposes the perovskite only after long time durations; and 2) rapid heating at large reverse-bias leading to formation of PbI2, which starts at shunts and then follows the path of the least resistance for the cell current, which is primarily influenced by the electrode sheet resistances. Finally, perovskite solar modules with carbon-based electrodes are demonstrated, which are subjected to a "hotspot" test described in the IEC 61215:2016 international standard at an accredited module testing laboratory. Passing this accelerated test for the first time confirms the superior stability of perovskite PV devices with carbon-based electrodes and highlights their large industrialization potential.

14 SOLAR ENERGY↗

A Revised International Standard for Gearboxes in Wind Turbine Systems

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

gearbox↗

A Revised International Standard for Gearboxes in Wind Turbine Systems: Preprint

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

ENGINEERING,WIND ENERGY↗

Physical and Visual Evaluation of Filters for Direct Observation of the Sun and the International Standard ISO 12312-2:2015

We investigated the compliance of 43 commercially available solar filters (eclipse glasses) with the ISO 12312-2:2015 standard by measuring their spectral transmittances (280–2000 nm) and calculating their luminous, solar ultraviolet A, ultraviolet B, and infrared (IR) transmittances. We also evaluated the filters for usability by observing the full midday Sun and rating the view on a seven-point balanced scale, from “far too dark, details seen only with great difficulty” to “far too light, uncomfortable to view the Sun.” The mean ratings of two observers, one experienced and one inexperienced in solar observing, differed by 0.28 (95% confidence interval of the mean = 0.26). The inexperienced observer tended to be less accepting of high transmittances. All 43 solar filters complied with the UV and IR requirements. Eighteen filters passed the luminous transmittance requirements, and 24 were borderline too light or too dark. Seven of the 15 solar filters with a luminous transmittance darker than the requirement were rated as acceptable. One filter that passed and another that was borderline too light were rated as too light or far too light. The ISO 12312-2 limits derive from welding filter standards and do not represent an appropriate evidence base for direct solar viewing. This work provides the evidence base for a maximum 0.0012% and a minimum 0.00004% luminous transmittance for solar filters. The results of this study also support the use of welding filters between shades 12 and 16. Lighter welding filters are more acceptable than solar filters of the same luminous transmittance.

79 ASTRONOMY AND ASTROPHYSICS↗

Domestic and International Consensus Standards for Nuclear Criticality Safety - Overview & Status

The domestic and international consensus standards for nuclear criticality safety (NCS) were developed based on the lessons-learned from process criticality accidents. These consensus standards were developed to reduce the rate of process criticality accidents in facilities that process, store, handle, or transport fissionable materials by hand. After a significant increase in criticality accidents through the mid-1960s, the rate of criticality accidents decreased as a result of these standards, and the criticality accident rate is extremely low from an industrial safety perspective. The last known criticality accident inside the United States was in 1978 (nearly 47 years ago) at the Idaho Chemical Processing Plant, and outside the United States, an accident occurred at Tokai-mura, Japan, in 1999 (almost 26 years ago). The domestic consensus standards for NCS include the American National Standards (ANS) that are prepared and published by the American Nuclear Society and approved by the American National Standards Institute (ANSI). The ANS Standards Board, the NCS Consensus Committee, and the ANS-8 Subcommittee oversee the development and maintenance of these standards. There are currently 18 standards in the ANS-8 series. Nine ANS-8 standards are either in revision mode or planned for revision. A new standard for the use of nondestructive assay measurements (ANSI/ANS-8.28-2024) for NCS was approved in March of 2024. The international consensus standards for NCS calculations, procedures, and practices are maintained and developed within the International Organization for Standardization, Technical Committee 85 “Nuclear Energy,” Subcommittee 5, “Nuclear Fuel Technology,” and Working Group 8, “Nuclear Criticality Safety.” Eleven standards are currently available, four standards are proposed for revision, and four standards are at various stages of development. This paper provides the NCS community with a high-level overview and status report of domestic and international NCS consensus standards to stimulate interest and to support their continued development.

Bowen, Douglas G [ORNL] (ORCID:0000000212460026)↗

Development of ASTM International D8405—Standard Test Method for Evaluating PM 2.5 Sensors or Sensor Systems Used in Indoor Applications

Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.

47 OTHER INSTRUMENTATION↗

Domestic and international consensus standards for nuclear criticality safety – overview & status [Abstract]

The domestic and international consensus standards for nuclear criticality safety (NCS) were developed as the lessons-learned from process criticality accidents. These consensus standards were developed to reduce the rate of process criticality accidents in facilities that process, store, handle or transport fissionable materials by hand. After a significant increase in criticality accidents through the mid-1960’s, the rate of criticality accidents decreased due to these standards and the criticality accident rate is extremely low from an industrial safety perspective.

ANS↗