Nondestructive Evaluation (NDE) of structural ceramics by photoacoustic microscopy
Photoacoustic microscopy (PAM) was utilized to detect surface and subsurface defects in structural ceramic materials. A computerized PAM data acquisition, color imaging and analysis system was developed and used. Subsurface simulated cylindrical holes can be detected to about 1 mm below the interrograting surface. Simulated tight surface cracks of 96 microns length and 48 microns depth can be detected in these materials under optimum conditions.