In a high-current interruption, the contact surface in a vacuum interrupter might be severely damaged by constricted vacuum arcs causing a molten area on it. As a result, a protrusion will be initiated by a transient recovery voltage after current zero, enhancing the local electric field and making breakdowns occur easier. The objective of this paper is to simulate the deformation process on the molten area under a high electric field by adopting the finite element method. A time-dependent Electrohydrodynamic model was established, and the liquid-gas interface was tracked by the level-set method. From the results, the liquid metal can be deformed to a Taylor cone if the applied electric field is above a critical value. This value is correlated to the initial geometry of the liquid metal, which increases as the size of the liquid metal decreases. Moreover, the buildup time of a Taylor cone obeys the power law t = k × E{sup −3}, where E is the initial electric field and k is a coefficient related to the material property, indicating a temporal self-similar characteristic. In addition, the influence of temperature has little impact on the deformation but has great impact on electron emission. Finally, the possible reason to initiate a delayed breakdown is associated with the deformation. The breakdown does not occur immediately when the voltage is just applied upon the gap but is postponed to several milliseconds later when the tip is formed on the liquid metal.
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whether global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.
Methods, apparatuses, and computer program products for servicing a globally broadcast interrupt signal in a multi-threaded computer comprising a plurality of processor threads. Embodiments include an interrupt controller indicating in a plurality of local interrupt status locations that a globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include a thread determining that a local interrupt status location corresponding to the thread indicates that the globally broadcast interrupt signal has been received by the interrupt controller. Embodiments also include the thread processing one or more entries in a global interrupt status bit queue based on whether global interrupt status bits associated with the globally broadcast interrupt signal are locked. Each entry in the global interrupt status bit queue corresponds to a queued global interrupt.
Executing application function calls in response to an interrupt including creating a thread; receiving an interrupt having an interrupt type; determining whether a value of a semaphore represents that interrupts are disabled; if the value of the semaphore represents that interrupts are not disabled: calling, by the thread, one or more preconfigured functions in dependence upon the interrupt type of the interrupt; yielding the thread; and if the value of the semaphore represents that interrupts are disabled: setting the value of the semaphore to represent to a kernel that interrupts are hard-disabled; and hard-disabling interrupts at the kernel.
Purpose: To investigate whether interruptions in radiotherapy are associated with decreased survival in a population-based sample of head-and-neck cancer patients. Methods and Materials: Using the Surveillance, Epidemiology, and End Results-Medicare linked database we identified Medicare beneficiaries aged 66 years and older diagnosed with local-regional head-and-neck cancer during the period 1997-2003. We examined claims records of 3864 patients completing radiotherapy for the presence of one or more 5-30-day interruption(s) in therapy. We then performed Cox regression analyses to estimate the association between therapy interruptions and survival. Results: Patients with laryngeal tumors who experienced an interruption in radiotherapy had a 68% (95% confidence interval, 41-200%) increased risk of death, compared with patients with no interruptions. Patients with nasal cavity, nasopharynx, oral, salivary gland, and sinus tumors had similar associations between interruptions and increased risk of death, but these did not reach statistical significance because of small sample sizes. Conclusions: Treatment interruptions seem to influence survival time among patients with laryngeal tumors completing a full course of radiotherapy. At all head-and-neck sites, the association between interruptions and survival is sensitive to confounding by stage and other treatments. Further research is needed to develop methods to identify patients most susceptible to interruption-induced mortality.
The coronavirus disease 2019 (COVID-19) has presented unprecedented challenges to the generic drug development, including interruptions in bioequivalence (BE) studies. Per guidance published by the US Food and Drug Administration (FDA) during the COVID-19 public health emergency, any protocol changes or alternative statistical analysis plan for COVID-19-interrupted BE study should be accompanied with adequate justifications and not lead to biased equivalence determination. In this study, we used a modeling and simulation approach to assess the potential impact of study outcomes when two different batches of a Reference Standard (RS) were to be used in an in vivo pharmacokinetic BE study due to the RS expiration during the COVID-19 pandemic. Simulations were performed with hypothetical drugs under two scenarios: (1) uninterrupted study using a single batch of an RS, and (2) interrupted study using two batches of an RS. The acceptability of BE outcomes was evaluated by comparing the results obtained from interrupted studies with those from uninterrupted studies. The simulation results demonstrated that using a conventional statistical approach to evaluate BE for COVID-19-interrupted studies may be acceptable based on the pooled data from two batches. An alternative statistical method which includes a “batch” effect to the mixed effects model may be used when a significant “batch” effect was found in interrupted four-way crossover studies. However, such alternative method is not applicable for interrupted two-way crossover studies. Overall, the simulated scenarios are only for demonstration purpose, the acceptability of BE outcomes for the COVID19-interrupted studies could be case-specific.
In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.
The risks of long-duration, widespread interruptions (LDWIs) in electrical power are a concern of U.S. regulators, the electric power industry, and stakeholders. Those responsible for making decisions about increasingly costly investments to prevent such interruptions and to facilitate rapid recovery when they do occur need relevant information on which to base those decisions. Although a number of studies have examined the physical and engineering impacts of extreme weather and other precipitating events on the bulk power system, decision makers evaluating investments in preventive strategies need information on the costs of past power interruptions and the benefits of preventing them in the future. This paper contributes to addressing this need by offering six case studies that detail the economics, at the level of the utility service territory, of power interruptions caused by extreme weather and lasting from a few days to several weeks. These intermediate-duration interruptions have been, and will continue to be, the most common type of major electric power disruption. They are longer than the short-term disruptions addressed in utility reliability planning, but not as long or widespread geographically as the national-scale interruptions with durations of many weeks, months, or longer that have been examined in some recent studies.
This technical brief estimates the expected performance of a solar photovoltaic and energy storage system (PVESS) for providing backup power during short-duration power interruption events, accounting for the unpredictable nature of those events. The analysis relies on the Power Reliability Event Simulation TOol (PRESTO), a publicly available model developed by Berkeley Lab to simulate the occurrence of short-duration power interruption events at the county-level. A separate storage dispatch model is then used to simulate PVESS operation and backup performance for each of the large number of interruption events produced by PRESTO. In performing this simulation, the analysis accounts for how the customer operates its battery on a day-to-day basis—in this case, we assume the battery is cycled each day in response to time-of-use rates—and how that, in turn, impacts the battery’s state of charge at the beginning of each interruption event. The analysis presented here is intended to demonstrate an application of the PRESTO model as well as to illustrate some of the key determinants of PVESS backup power performance during short-duration power interruption events. The analysis focuses initially on a typical single-family home in Maricopa County, Arizona, and includes a limited set of scenarios related to system sizing, backup power configuration, and whether the customer charges its battery storage system from the grid during normal operating conditions. The analysis also presents comparative results for two other counties, in Massachusetts (Middlesex) and California (Los Angeles), illustrating how regional differences in climate, interruption patterns, and retail rate structures can affect PVESS performance as a backup power source. In the conclusions, we highlight a number of other important considerations for evaluating PVESS backup power capabilities.
Purpose: To determine sensitivity and specificity of the “duct-interrupted,” “corona,” and “attraction” signs on MR cholangio-pancreatography (MRCP) in distinguishing pancreatic head ductal adenocarcinoma (PDAC) from inflammatory pancreatic pseudomass (IPP). Materials and methods: This study included 53 adults (33 men and 20 women, mean age, 55 years; range, 17–87 years) with a pancreatic head mass who underwent MRCP. Three blinded radiologists independently reviewed each MRCP exam and three signs were assessed: (1) the “duct-interrupted” sign, deemed positive for PDAC if the duct within the mass demonstrated complete interruption with upstream dilation; (2) the “corona” sign, considered positive for PDAC if dilated side-branches were located exclusively outside the mass; and (3) the “attraction” sign, deemed positive for IPP if the dilated common bile duct showed attraction and angulation towards the mass. Sensitivity, specificity, and positive and negative predictive values of the signs were calculated, as well as interobserver agreement. Results: Out of 53 masses, 17 (32%) were PDAC and 36 (68%) were IPP. Sensitivity, specificity, and positive and negative predictive values of the “duct-interrupted” sign to differentiate between PDAC from IPP for the three readers were 29–53%, 89–95%, 56–82% and 73–81%, respectively (κ = 0.41); for the “corona” sign, they were 29–53%, 81–100%, 56–100%, and 75–78%, respectively (κ = 0.4), and for the “attraction” sign, they were 20–25%, 71–82%, 64–75%, and 31–34%, respectively (κ = 0.54). Conclusion: The “duct-interrupted” and “corona” MRCP signs have high specificity for diagnosing PDAC, while the “attraction” sign has good specificity for identifying IPP.
Highlights: • Study of usefulness of stored strain energy distribution map of the material for variable temperature range. • Advantage of using stored strain energy distribution map • Variation observed in stored energy between isothermal annealing treatment and interrupted annealing treatment. - Abstract: This research work is an attempt to understand the effect of stored strain energy heterogeneity over macro-scale, induced during interrupted annealing treatment, on the micro structural evolution in a heavily cold rolled AISI 304L austenitic stainless steel. The cold rolled AISI 304L stainless steel (SS) samples were subjected to different annealing treatments. The microstructures obtained after each annealing treatment were characterized using optical and electron microscopy techniques. Further, an attempt was made to estimate the stored strain energy by a novel approach of micro hardness measurement both over small scale (area 3600 μm{sup 2}) and large scale (area ~0.25 mm{sup 2}). The stored strain energy was determined using hardness values. Using these data, spatial stored strain energy distribution contour maps were created. They were, in turn, used to characterize the local softening behavior both at micro and macro-scale levels after each interrupted annealing treatment. The results showed that, interrupted annealing treatment induces increased stored strain energy heterogeneity after each annealing interruptions. Also, it was possible to determine recrystallization kinetics of the material using stored strain energy map, which helps in designing annealing cycles for achieving ultrafine grained microstructure.
The costs to electric utility customers from short-term, limited geographic-scale power disruptions have been studied for many years. However, there is increasing interest among regulators, policy-makers, and utilities in developing and implementing methods for analyzing interruptions that are of longer duration (days, weeks, or longer) and of a larger geographic scope (entire metropolitan areas or regions which may extend across multiple service territories). A 2017 report from the U.S. National Academies of Sciences, Engineering, and Medicine indicated the importance of “develop[ing] comprehensive studies to assess the value to customers of improved reliability and resilience…during large-area, long-duration blackouts.” As a contribution toward fulfilling this recommendation, the U.S. Department of Energy’s (DOE) Office of Electricity’s Transmission Permitting and Technical Assistance Division, in partnership with Lawrence Berkeley National Laboratory (LBNL), convened a workshop to identify research needs and discuss potential avenues for methodological advances in the economics of widespread, long-duration power interruptions. The workshop was organized around six key themes in the economics of widespread, long-duration interruptions. LBNL conducted a competitive solicitation for white papers on these themes, and the authors selected were leading experts in academia, industry, and the non-profit sector. They were tasked with assessing the state of knowledge on particular topics, and identifying research needs and promising directions to expand it. These topics included definitions of resilience and reliability; regional economic modeling approaches; uncertainty quantification; data challenges and opportunities; contingent valuation survey techniques; and reduced-form analytical tools for assessing the impacts of power interruptions of this scale. The authors of the six white papers presented their findings at the workshop, titled “Frontiers in the Economics of Widespread, Long-Duration Power Interruptions,” and held in Washington, D.C., on March 6, 2018. Each paper was the subject of its own session, with the presentations followed by comments by assigned discussants, and in turn a general discussion of the papers, their findings, and the issues they raised. In addition to the authors, discussants, and LBNL and DOE staff, the workshop participants comprised government, industry, and academic thought leaders from across the country.
The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.
ICE 2.0 Phase 2 Final Report In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE Calculator 2 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE Calculator 2 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 and 2 of the ICE Calculator 2 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 2 was sponsored by six utilities: Empire District Electric Company, Evergy Missouri, Pacific Gas & Electric, San Diego Gas & Electric, Southern California Edison, and Union Electric. Phase 1 and 2 involved 15 customer interruption cost survey activities representing a total of 30 electricity distribution service territories. ICE Calculator Version 2.0 and 2.2 Comparison This memorandum describes–at a high-level–the improvements in interruption cost estimates for the version 2.2 of the ICE Calculator (released February 2026) compared to version 2.0 (released in April 2025). Version 2.2 of the ICE Calculator corresponds to Phase 2 of the initiative, while version 2.0 corresponds to Phase 1. The improvements in version 2.2 result from both a significant increase in the number of customer responses that have been collected and the identification of seven additional factors that help estimate customer interruption costs.
Modern grid monitoring equipment enables utilities to collect detailed records of power interruptions. Here, these data are aggregated to compute publicly reported metrics describing high-level characteristics of grid performance. The current work explores the depth of insights that can be gained from public data, and the implications of losing visibility into heterogeneity in grid performance through aggregation. We present an exploratory analysis examining three years of high-resolution power interruption data collected by archiving information posted in real-time on the public-facing website of a utility in the Western United States. We report on the size, frequency and duration of individual power interruptions, and on spatio-temporal variability in aggregate reliability metrics. Our results show that metrics of grid performance can vary spatially and temporally by orders of magnitude, revealing heterogeneity that is not evidenced in publicly reported metrics. We show that limited access to granular information presents a substantive barrier to conducting detailed policy analysis, and discuss how more widespread data access could help to answer questions that remain unanswered in the literature to date. Lastly, given open questions about whether grid performance is adequate to support societal needs, we recommend establishing pathways to make high-resolution power interruption data available to support policy research.
This research article explores the behavior of a phase change material (PCM) when it undergoes interrupted melting and freezing, through experimental investigations using a heat flow meter apparatus. A fatty acid-based organic PCM, encapsulated within polyethylene and thin aluminum foil layers, was experimentally tested in this study. Experiments were designed to represent multiple interrupted phase change scenarios that could occur within PCMs applied in buildings. The experimental results were analyzed and compared with previously reported assumptions in numerical models dealing with PCM hysteresis and interrupted phase change processes. These comparisons indicated that the assumptions used in the different numerical models considered can capture the interrupted phase change phenomena with varying degrees of accuracy. The findings also highlighted the need for additional experimental research on different phase change processes that can occur in building applications of PCMs.