Search NASA⌕ Search

SEARCH · Search NASA

Results for “inverse beta decay simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

NuSD: A Geant4 based simulation framework for segmented anti-neutrino detectors

NuSD: Neutrino Segmented Detector is a Geant4-based user application that simulates inverse beta decay event in a variety of segmented scintillation detectors developed by different international collaborations. This simulation framework uses a combination of cross-programs and libraries including Geant4, ROOT and CLHEP developed and used by high energy physics community. It will enable the neutrino physics community to simulate and study neutrino interactions within different detector concepts using a single program. In addition to neutrino simulations in segmented detectors, this program can also be used for various research projects that use of scintillation detectors for different physics purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy neutrino detection with a compact water-based liquid scintillator detector

In this study, the conceptual design and physics simulations of a near-field Water-based Liquid Scintillator (WbLS) detector placed 100 m from the Akkuyu Nuclear Power Plant (ANPP), currently under construction and aiming at being Turkey’s first nuclear power plant, is presented. The ANPP is an excellent opportunity for neutrino studies and the development of an R &D program for neutrino detectors in Turkey. The Reactor Neutrino Experiments of Turkey (RNET) program includes a compact detector with a 2.5-ton volume of WbLS and a ~ 30% photo-coverage, and the program is planned to be expanded with a medium-size 30-ton detector that will be an international testbed for WbLS and new detector technologies through low energy neutrino studies. In the following, the focus will be on the smaller ~2.5 ton detector, instrumented with 8-in. high quantum efficiency PMTs and two layers of cosmic veto paddles, covering all sides of the detector, to track and veto cosmic particles. Inverse Beta Decay (IBD) events from electron anti-neutrinos generated in the reactor core are simulated using the RAT-PAC simulation package and several liquids with different percentages of Liquid Scintillator (LS) and Gadolinium (Gd) are investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics model enhancements in MARLEY version 2

Large next-generation neutrino detectors, such as those designed for accelerator-based oscillation experiments, are expected to have impressive sensitivity to MeV astrophysical neutrinos generated by the Sun and by supernovae. There are also numerous related prospects to search for MeV-scale phenomena beyond the Standard Model. In contrast to detectors constructed with water and hydrocarbon targets, which will be primarily sensitive to electron antineutrinos via inverse beta decay, the upcoming Deep Underground Neutrino Experiment (DUNE) will provide unparalleled capabilities to measure low-energy electron neutrinos from cosmic sources. Interpreting such future measurements in DUNE will require a high-quality simulation of MeV interaction physics in the argon nucleus. The MARLEY (Model of Argon Reaction Low Energy Yields) neutrino event generator has been designed with the goal of delivering the needed simulation capabilities for DUNE and other argon-based neutrino detectors. In this poster, I will present recent improvements to MARLEY's suite of interaction models, which will be released for general use by the neutrino community in version 2 of the software.

Gardiner, Steven James [Fermilab] (ORCID:000000028↗

Physics model enhancements in MARLEY version 2

Large next-generation neutrino detectors, such as those designed for accelerator-based oscillation experiments, are expected to have impressive sensitivity to MeV astrophysical neutrinos generated by the Sun and by supernovae. There are also numerous related prospects to search for MeV-scale phenomena beyond the Standard Model. In contrast to detectors constructed with water and hydrocarbon targets, which will be primarily sensitive to electron antineutrinos via inverse beta decay, the upcoming Deep Underground Neutrino Experiment (DUNE) will provide unparalleled capabilities to measure low-energy electron neutrinos from cosmic sources. Interpreting such future measurements in DUNE will require a high-quality simulation of MeV interaction physics in the argon nucleus. The MARLEY (Model of Argon Reaction Low Energy Yields) neutrino event generator has been designed with the goal of delivering the needed simulation capabilities for DUNE and other argon-based neutrino detectors. In this talk, I will present recent improvements to MARLEY's physics models, which will be released for general use by the neutrino community in version 2 of the software.

Gardiner, Steven James [Fermilab] (ORCID:000000028↗

Algorithm to extract direction in 2D discrete distributions and a continuous Frobenius norm

In this study, we present a novel algorithm for determining directionality in 2D distributions of discrete data. We compare a reference dataset with a known direction to a measured dataset with an unknown direction by the Frobenius norm of the difference (FND) to find the unknown direction. To generalize this concept, we develop a continuous Frobenius norm of the difference (CFND) as a continuous analog of the FND and derive its analytical expression. By relating fitted and normalized 2D Gaussian distributions, we show that the CFND approximates the FND, and we validate this relationship with computer simulations. We find that a first-order approximation of the CFND between two similar Gaussian distributions takes the form of an absolute sine function, offering a simple analytical form with potential for specialized applications in segmented inverse beta decay (IBD) neutrino detectors, astronomy, machine learning, and more. Although this method may easily extend to 3D scalar fields, our focus here is on 2D real-valued fields as it directly applies to directionality. Our methodology consists of modeling a 2D Gaussian distribution, binning the data into a histogram, and encoding it as a square matrix. Rotating this matrix around its geometric center and comparing it to a measured dataset using the FND gives us rotational data that we fit with an absolute sine function. The location of the minimum of this fit is the angle closest to the true angle of the direction in the measured dataset. We present the derivation and discuss initial applications of the CFND in our novel algorithm, demonstrating its success in approximating directionality in 2D distributions.

Data Analysis, Statistics and Probability (physics↗

Algorithm to extract direction in 2D discrete distributions and a continuous Frobenius norm

In this study, we present a novel algorithm for determining directionality in 2D distributions of discrete data. We compare a reference dataset with a known direction to a measured dataset with an unknown direction by the Frobenius norm of the difference (FND) to find the unknown direction. To generalize this concept, we develop a continuous Frobenius norm of the difference (CFND) as a continuous analog of the FND and derive its analytical expression. By relating fitted and normalized 2D Gaussian distributions, we show that the CFND approximates the FND, and we validate this relationship with computer simulations. We find that a first-order approximation of the CFND between two similar Gaussian distributions takes the form of an absolute sine function, offering a simple analytical form with potential applications in specialized areas such as segmented inverse beta decay neutrino detectors, astronomy, machine learning, and more. Our methodology consists of modeling a 2D Gaussian distribution, binning the data into a histogram, and encoding it as a square matrix. Rotating this matrix around its geometric center and comparing it to a measured dataset using the FND gives us rotational data that we fit with an absolute sine function. The location of the minimum of this fit is the angle closest to the true angle of the direction in the measured dataset. We present the derivation and discuss initial applications of the CFND in our novel algorithm, demonstrating its success in approximating directionality in 2D distributions.

Physics↗

Simulation study of the role of ion kinetics in low-frequency wave train evolution

The evolution of uniform, parallel propagating, low-frequency (less than or approx. ion cyclotron) wave trains is followed with a one-dimensional hybrid numerical code with fluid electrons and particle ions. We show that moderate amplitude (delta B/B less than 1/2) wave trains give instabilities and saturated states which differ completely from pure fluid evolution. This is most clearly seen when beta greater than 1 and instability exists for wavenumbers both below and above the wavenumber of an inital, left-handed wave train or pump wave. For corresponding parameters a fluid theory gives only a narrow range of instability above the pump wavenumber where decay and beat instabilities can occur. in simulations wave energy inverse cascades to smaller wavenumbers and into a greater number of forward than backward going waves. In fluids energy by decay goes mostly to backward ones of smaller wavenumber, and energy by beat goes mostly to forward ones of larger wavenumber. Neither fluid instability explains simulation results. The instability is saturated by thermalizing ions and sometimes exciting small wavenumber electrostatic or acoustic modes. In contrast, saturation in fluids first occurs by generating the harmonics of the growing linear modes. Harmonic generation is mostly absent in simulations. Simulations are carried out to long times and mostly reach a limit beyond which no further significant evolution can occur. Application to Alfvenic fluctuations in the solar wind is discussed.

Vasquez, Bernard J.↗

Preliminary plume characteristics of an arcjet thruster

An experimental investigation of a low power arcjet plume was conducted using emission spectroscopy. A laboratory model arcjet incorporating a segmented anode was run on simulated hydrazine at a flow rate of 5 x 10(exp -5) kg/s. The complete visible spectrum measured in the exit plane of the arcjet showed the presence of N2, N2(+), NH, and H. Radial intensity profiles for the H alpha, H sub beta, and the NH A(sup 3)Pi yields X(sup 3)Sigma(0,0) transitions at four different axial locations were measured. These line of sight intensity measurements, spaced 0.05 mm apart, were deconvoluted to give the radial intensity distribution using an inverse Abel transformation. The ratio between the intensities from the H sub alpha and H sub beta transitions indicated a non-Boltzmann energy distribution between excited states in the plume. Axial intensity profiles taken on center line indicated the decay rate of excited states in the plume. An electron number density of 2 x 10(exp 13)/cu cm at the exit plane was determined based on Stark broadening of the H sub beta line. Rotational temperatures of 750 K, 1750 K, and 2500 K were determined for N2, N2(+), and NH respectively. The results demonstrate that the location of the current attachment on the anode has a measurable effect on the electronically excited species in the plume and that dissociation is the dominant frozen flow loss mechanism in low power arcjets.

Manzella, David H.↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗