Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion exchange capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Standard Operating Protocol for Ion-Exchange Capacity of Anion Exchange Membranes

Ion-exchange capacity (IEC) is the measure of a material’s capability to displace ions formerly incorporated within its structure. IEC is a key feature of anion-exchange membranes (AEM), as it determines the AEM’s ability to conduct the ions required to sustain the electrochemical reactions where they are utilized. As an intrinsic property, measuring the IEC accurately is essential to study AEMs and understand their performance within devices. In this method article, a facile and accurate standard operating procedure (SOP) to measure the IEC of AEMs is proposed. When compared to conventional acid-base back-titration or Mohr titration, the proposed method combines the fast reaction between silver and halide ions and the accuracy of the potentiometric titration, providing a convenient and precise protocol for researchers in the field.

42 ENGINEERING↗

Ether Cleavage Decreases the Ion Exchange Capacity of Anion Exchange Membranes

Anion exchange membranes (AEMs) are integral to fuel cells and water electrolysis systems but suffer from poor durability under alkaline conditions. Ether cleavage is an important failure pathway of poly(arylene ether)-based AEMs that compromises both mechanical stability and ion transport. While this degradation pathway is often studied in terms of polymer fragmentation, the role of newly formed hydrophilic groups has been largely overlooked. Here, we show that polymer scission leads to reduced mechanical rigidity, while the introduction of hydrophilic groups partially mitigates this loss. Under alkaline conditions, phenoxide groups formed during ether cleavage neutralize the polymer cations, leading to a previously unreported loss of ion exchange capacity (IEC). This IEC loss mechanism exacerbates the reduction in ionic conductivity, emphasizing the severity of ether cleavage as a degradation pathway. Recognizing that ether cleavage introduces significant chemical changes beyond polymer fragmentation provides critical insights into its interplay with other degradation mechanisms, such as the direct reduction of cationic sites by E2 and S N 2, and provides molecular-level interpretations for the concurrent effects of polymer scission and increased hydrophilicity on membrane performance.

crystal cleavage↗

Assessing the Long-Term Stability of Anion Exchange Membranes for Electrochemical CO 2 Reduction

Materials and cell components used in CO 2 electrolysis have largely been adapted from technologies initially developed for water electrolysis and fuel cells. However, electrochemical CO 2 reduction introduces distinct material challenges due to the unique chemical environment in this process. Here, in this study, we conducted ex-situ 1000 h stability tests on commonly used anion exchange membranes, exposing them exclusively to electrolytes and organic molecules used or produced during CO 2 electrolysis, at concentrations relevant to and compatible with postseparation processes. Notably, 15% w/w n-propanol and 5 M acetic acid caused complete dissolution or partial disintegration of the membranes unless cross-linking was present and remained stable throughout the test. When the membranes stayed physically intact, most of them exhibited excellent chemical stability in alkaline medium containing alcohols or formic acid, which was confirmed by vibrational spectroscopy and ion exchange capacity measurements. However, exposure to alcohol-and acid-containing solutions led to a substantial increase in swelling and water uptake, with potential implications for mechanical stability, ion/product crossover, and compression management of adjacent components. The potential effects of CO 2 electroreduction products on membrane stability, their subsequent impact on electrolyzer performance, and mitigation strategies are discussed.

CO2RR↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode

Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.

08 HYDROGEN↗

Uptake and binding of La 3+ and Cr 3+ ions by alkali metal substituted alpha-zirconium phosphate

The conversion of alpha-zirconium phosphate, Zr(HPO 4 ) 2 ·H 2 O, to the K-, Rb-, and Cs-phases and the subsequent ion exchange behavior of these alkali metal phases, A-ZrP, with La 3+ and Cr 3+ have been investigated. The conversion to the A-ZrP phases was achieved by reaction with metal chloride, metal hydroxide solution, and confirmed through various techniques, including X-ray powder diffraction, thermogravimetry analysis, IR spectroscopy, scanning and transmission electron microscopy, and X-ray photoelectron spectroscopy. The effect of material hydration, which increased the interlayer distance, was also examined. The ion exchange behavior of the A-ZrP showed strong affinity for both La 3+ , a representative for trivalent lanthanide metals, and Cr 3+ , a representative for the trivalent transition metals, with a rapid, near quantitative removal of the M 3+ ions at a pH of 3 when the ion concentration was ≤25% of the ion exchange capacity of the materials. Additionally, the ion affinity was shown to be pH and concentration-dependent, decreasing with a decrease in pH or an increase in ion concentration. Lastly, the binding strength of La- and Cr-loaded ZrP materials was examined through a series of leaching experiments in a carbonate buffer, phosphate buffer, HEPES buffer, and a series of EDTA solutions at various concentrations. No observable leaching occurred in the carbonate buffer, phosphate buffer, HEPES buffer, or when the EDTA concentration was below 0.1 mM. These results highlight the potential for the A-ZrP materials to provide a platform for trivalent transition metal and trivalent lanthanide radionuclide capture for various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LTE-P-7 IEC AEM SOP

A procedure for measuring the ion exchange capacity (IEC) of an anion exchange membrane (AEM). This is done via a titration method (automated or manual).

08 HYDROGEN↗

Anion exchange membrane test protocol validation

This study presents the validation of protocols for measuring ion exchange capacity (IEC) and alkaline stability of anion exchange membranes (AEMs) for low-temperature water electrolysis. While protocols are often tested within individual laboratories, their results across multiple laboratories with varying equipment, environmental conditions, and personnel qualification remain unverified. The validation involved Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), and University of Oregon (UO) using the same commercially available AEM to assess reproducibility and reliability of the protocols under diverse conditions. For the IEC protocol, results across laboratories were consistent within ±10% of the NMR-determined reference value. The alkaline stability protocol could pose greater challenges due to factors such as variations in sample collection timing, preservation methods, and analytical techniques, but consistent test results for percentage IEC loss were demonstrated across institutions. These results highlight the reliability and applicability of the protocols, emphasizing the importance of validation to ensure consistency in diverse research environments.

08 HYDROGEN↗

LTE-P-3 IEC PEM SOP

A procedure for measuring the ion exchange capacity (IEC) of a proton exchange membrane (PEM).

08 HYDROGEN↗

Exponential Water Uptake in Ionomer Membranes Results from Polymer Plasticization

Water content is the most influential factor in the performance of ion-exchange membranes (IEMs), controlling their mechanical rigidity, ionic conductivity, and degradation rates. Membranes absorb water exponentially at high water activity (a w ), making that region of the sorption isotherm the most influential on membrane properties. Plasticization of the polymer by water has been proposed to cause this exponential uptake at high a w . However, an integrated microscopic picture of the structure, thermodynamic, and mechanical properties of IEMs as a function of a w has remained elusive. In this work, we use large-scale molecular simulations validated with experimental measurements to compute the sorption isotherms, Young’s modulus, polymer dynamics, and structure of IEMs. The simulations unveil that the exponential increase in water uptake (WU) coincides in all cases with the glass to rubber transition of the membrane, as measured through its Young’s modulus and segmental polymer dynamics. Functionalization of the polymer with alkyl groups further contributes to its plasticization, increasing the WU at a given a w and ion-exchange capacity (IEC). The alkyl chains act synergistically with water to plasticize the polymer matrix and allow water penetration in the membrane. The simulations reveal that the width of the water channels depends on the ratio λ of water to ions in the polymer but is independent of its IEC. We conclude that differences in the polymer matrix–not the water channels–are responsible for the distinct uptake response of IEMs to the thermodynamic driving force of water activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origins of Enhanced Ion Transport in Nanostructured Anion-Conducting Polyelectrolytes

Ion-conducting polymer chemistry and microstructure profoundly impact membrane water uptake and ionic conductivity. Water uptake strongly impacts ionic conductivity; yet excess water uptake compromises ion-exchange membrane mechanical properties. Although nanophase separation has been proposed to overcome this trade-off, it is unclear how polymer backbone architecture governs ionic nanostructure and its subsequent impact on water uptake and conductivity. Here, we integrate experiments and molecular dynamics simulations to elucidate the role of backbone chemistry in governing ionic nanostructure, hydration behavior, and ion transport in anion-conducting polyelectrolytes (ACPs). We systematically investigate hydrocarbon polynorbornene (PNB)-based ACPs with three distinct backbone architectures: vinyl-addition polymerization (VAP), ring-opening metathesis polymerization (ROMP), and hydrogenated ROMP. While maintaining comparable ion exchange capacities (IECs) and identical side-chain chemistry, we isolate the effects of backbone structure. We show that nanophase-separated ionic nanostructures originate in the dry state and evolve upon hydration through heterogeneous water uptake, with water preferentially partitioning into ion-rich domains. This nanophase separation arises from a delicate interplay between ionic segregation propensity and the entropic barrier imposed by backbone stiffness. Specifically, flexible backbones intensify attractive ion–ion interactions by reducing the entropic penalty for backbone deformation, promoting nanophase separation, while rigid backbones suppress ionic nanostructure formation. Nanophase-separated ion domains locally concentrate water upon hydration, which in turn enables the connectivity required for fast transport at lower water concentration values. Furthermore, these findings demonstrate that backbone chemistry can be tuned as a design lever to promote nanophase separation and enhance ion transport without excessive water uptake.

Anions↗

Effects of the Hydrophobic Block Length Ratio of Poly(vinylbenzyl N -methylpiperidinium carbonate)- b -polyethylene- b -poly(vinylbenzyl N -methylpiperidinium carbonate) Block Copolymers for Anion Exchange Membrane Electrolysis

Electrolysis of water to produce hydrogen from renewable electricity is an extremely attractive strategy to reduce energy dependence on fossil fuels. Development of membrane and ionomer materials that maintain high performance with long lifetimes is needed. We developed and investigated the performance and durability of a series of polyethylene-based ABA triblock copolymer anion exchange ionomer and membrane (AEI, AEM) materials for anion exchange membrane water electrolysis. Poly(vinylbenzyl N-methylpiperidinium carbonate)-b-polyethylene-b-poly(vinylbenzyl N-methylpiperidinium carbonate) was synthesized with different hydrophobic/hydrophilic block ratios (1.02:1, 2.58:1, and 4.46:1) resulting in a range of ion exchange capacities (1.1–1.8 meq g –1 ) and water swelling (23–154%) characteristics. All AEMs showed full anionic dissociation, as evidenced by linear Arrhenius correlations, and excellent carbonate conductivity of 8–94 mS cm –1 at 50 °C. Hydrophilic phase separation may offer superior chemical durability by only wetting the ion-conducting region of the polymer and avoiding attack at the nonwetted backbone. We evaluated the performance and durability of these AEMs as a function of hydrophobic polyethylene (PE) content. The AEM containing the least amount of PE displayed the highest performance of 1 A cm –2 at 2.3 V but degraded at 40 mV h –1 before catastrophically failing after <3 h at 0.5 A cm –2 . With greater PE-containing AEMs, the degradation rate was reduced by 3 orders of magnitude with only a 0.2 V increase in voltage. Constant current electrolysis for 50 h resulted in a voltage change of 0.3 mV h –1 in a single-cell water electrolyzer and 1 M potassium carbonate. In a 600 h test, the voltage change in the final 200 h was impressively low for an experimental film, 58 μV h –1 . Postmortem analysis indicated that the membrane did not thin and that water becomes more tightly hydrogen-bound in the polymer after electrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Load Behavior for Select Analytes in Hanford Tank Waste

Crystalline silicotitanate (CST) inorganic ion exchanger is a candidate material for remediation of highly alkaline (pH > 14) aqueous nuclear waste streams containing high sodium concentrations (>5 M). In this work, ion exchange column testing with wastes from Hanford tanks AP-105, AP-107, and AW-102 was carried out to study the uptake of 137 Cs to estimate the decontamination factor (DF) value. Additionally, DF values for uptake of Al, Ca, Pb, Np, Pu, U, and Sr were determined and the ion exchange capacity of CST toward these analytes was estimated. Limited data is available on the load behavior of other minor and trace elements with recent CST production lots and this characterization will help improve understanding of the behavior of CST and assist in identifying potential disposition pathways as well as assessing removal capabilities of CST for other components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding the impact of SPMAK and PEGPEA in crosslinked PEGDA membranes: Methanol-carboxylate co-transport behavior and correlating structure-physicochemical-transport properties

Investigating multicomponent transport in dense, hydrated polymer membranes is necessary in applications such as fuel cells, electrolyzers, and desalination systems. Of particular interest are photoelectrochemical CO 2 reduction cells (PEC-CRC) which produce liquid products such as alcohols (methanol) and carboxylates (formate, acetate). Flux coupling and competitive sorption behavior of these products (solutes) have been found to affect permselectivity, thereby motivating us to investigate fundamental membrane structure-physicochemical-transport relationships. Past research has shown that systematic tuning of crosslinked cation exchange membranes (CEMs) with charge-neutral monoacrylate monomers containing alkyl and phenyl groups (i.e., poly(ethylene glycol) methacrylate (PEGMA), and poly(ethylene glycol) phenyl ether acrylate (PEGPEA)) can suppress acetate transport (permeability) in co-permeation with methanol. To further investigate this transport behavior and to enhance membrane ionic conductivities, 3-sulfopropyl methacrylate potassium (SPMAK), a sulfonated monoacrylate monomer is incorporated here. SPMAK content is varied with neutral PEGPEA and diacrylate crosslinker, poly (ethylene glycol) diacrylate (PEGDA) of two different chain lengths (n = 10 and 13) to prepare membranes of various compositions. Electrochemical and physicochemical properties including ionic conductivity, ion exchange capacity, and water uptake increase with increasing charged SPMAK content. Different states of water within hydrated membranes are probed using differential scanning calorimetry (DSC), where increasing intermediate (loosely bound) water is observed with increasing hydrophilic SPMAK content. The transport behavior of methanol and carboxylates (formate, acetate, propionate) are investigated, where permeabilities vary as methanol > formate > acetate ≈ propionate. Interestingly, permeabilities decrease with increasing PEGPEA content and are more dependent on solute diffusion than sorption. Permeabilities and diffusivities decrease while permselectivities increase with decreasing PEGDA chain length.

25 ENERGY STORAGE↗

Bipolar Membranes Electrodialysis for Water Purification and Resource Recovery

Reverse osmosis concentrate (ROC) from inland brackish water desalination and wastewater recycling presents moderate salinity, posing significant challenges for treatment and disposal. Existing treatment technologies predominantly rely on energy-intensive thermal methods, large-area evaporation strategies, or deep-well disposal, which often result in the loss of water value. Electrified membrane brine treatment offers a promising alternative by utilizing renewable energy sources, enabling complete water recycling. This work proposes the development of next-generation bipolar membrane electrodialysis (BMED) systems capable of desalinating brine while simultaneously recovering valuable resources. However, several critical challenges remain in the areas of membrane engineering for BMED. These include: 1) decreased current efficiency during desalination due to the low conductivity of feed chambers, 2) fouling and scaling from multivalent ions and contaminants in the feed, and 3) the retention and carryover of ROC contaminants, including PFAS compounds. Our research focuses on the development of novel anion exchange membranes (AEMs) and cation exchange membranes (CEMs) based on synthesized multiblock copolymers. We investigate the effects of block length, ion exchange capacity (IEC), and polymer backbone structure on cation and anion transport (e.g., Na+, Cl-, OH-, H+) for both our synthesized membranes and commercial membranes. Fundamental properties of these membranes, such as water uptake, IEC, and ionic conductivity, are also evaluated to optimize performance for BMED applications.

08 HYDROGEN↗

Impact of anion-exchange membrane degradation on long-term CO 2 electrolysis to ethylene

Electrochemical CO 2 reduction (eCO2R) to ethylene offers a unique opportunity to diversify domestic supply chains for chemical manufacturing. Large-scale deployment of eCO2R to ethylene reactors is currently limited by low energy efficiencies and poor durability. Herein, we demonstrate >100 h of continuous electrolysis at an industrially relevant current density of 200 mA cm −2 in a 25 cm 2 geometric area zero-gap reactor with a full-cell voltage <3.1 V and ethylene Faradaic efficiency >30%. Incorporating expanded polytetrafluoroethylene (PTFE)-supported electrodes into zero-gap reactors allows for durable electrode catalysts that are resistant to flooding, and this enables wider ranges of operating parameters not typically accessible in CO 2 electrolysis. Finally, we identify membrane degradation, evidenced by a loss of membrane ion-exchange capacity, as the leading cause of performance loss over 144 h of electrolysis.

Energy - Conversion↗

Anion exchange membranes based on (3-acrylamidopropyl) trimethylammonium chloride (APTA) and phenyl Acrylate: Impact of crosslinker and crosslinker content on physiochemical properties and transport behavior of acetate and formate

CO 2 reduction cells are innovative devices that convert CO 2 into valuable chemicals, such as formate (OFm - ) and acetate (OAc - ), at the cathode. One of the key challenges in these devices is the development of ion exchange membranes that enable the transport of charge carriers between electrodes while minimizing the transfer of CO 2 reduction products. This study focuses on the preparation and characterization of crosslinked anion exchange membranes (AEMs) made of phenyl acrylate (PA) and (3-acrylamidopropyl) trimethylammonium chloride (APTA), crosslinked with either poly(ethylene glycol) diacrylate (PEGDA) or N,N’-methylenebisacrylamide (MBAA). Here, the membranes are characterized to understand their physiochemical properties and corresponding transport behavior through characterization of water volume fraction, mechanical properties, ionic conductivity, ion exchange capacity, water contact angle, glass transition temperature as well as their permeability and solubility to formate and acetate. MBAA crosslinked membranes exhibit higher Young’s modulus and lower strain at break compared to PEGDA-crosslinked membranes, which is attributed to their shorter chain length. Within a series of membranes of varied comonomer content, for either PEGDA or MBAA as crosslinker, permeabilities generally follow free volume theory (increasing permeability with increasing water content where water content increases with decreasing crosslinker content). Interestingly, for membranes with different crosslinkers but analogous water volume fraction significant differences (∼2 orders of magnitude) in permeability are observed which we attribute to differences in chain mobility as characterized through the glass transition temperature.

25 ENERGY STORAGE↗