Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion-specific electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Utah FORGE 3-2418: Wellbore Fracture Imaging Using Inflow Detection Measurements - Workshop Presentation

This is a presentation on the Wellbore Fracture Imaging Using Inflow Detection Measurements project by Stanford University, presented by Dr. Roland N. Horne. The project's objective was to make measurements in the Utah FORGE wells, both before and after fracturing experiments, to map the fractures and estimate their flow magnitude. The approach utilizes a ion-specific electrode that will measure chloride in the well. The idea is that water flowing into the well from the fractures will have a different concentration of chloride than the surrounding water. This presentation was featured in the Utah FORGE R&D Annual Workshop on September 8, 2023. The workshop provided a valuable opportunity to explore the progress made in each of the 17 Research and Development projects funded under Solicitation 2020-1 which aim to enhance our understanding of the crucial factors influencing the development of Enhanced Geothermal Systems (EGS) reservoirs and resources.

15 GEOTHERMAL ENERGY↗

The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗

The Spacecraft Water Impurity Monitor, a Framework for the Next Generation Complete Water Analysis System for Crewed Vehicles Beyond the ISS

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. Eventually, missions to the moon, Mars, and beyond will be equipped with analytical capabilities equaling those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. This paper discusses the challenges presented by exploration requirements and the research and development progress toward the goal of a total water analysis system. For organic analysis, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For inorganic analysis, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

water monitoring↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Disentangling cation effects on ion mobility and structure in ionic liquid electrolytes

Ionic liquids (ILs) are low-temperature molten salts, where ion transport is primarily governed by ion–ion interactions. Yet, the impact of organic IL cations on critical electrolyte properties such as ion dissociation and overall transport behavior in lithium-salt-doped ILs remains poorly understood. Moreover, despite their critical role in designing IL-based electrolytes for energy storage applications, ion–ion interactions and ion-specific transport under an applied electrical potential are seldom quantified, largely due to the unique experimental and computational challenges involved. Herein, we compare transport properties obtained using 1 H, 7 Li, and 19 F pulsed-field gradient nuclear magnetic resonance (NMR) and electrophoretic NMR (eNMR) with those measured by electrochemical impedance spectroscopy. Non-equilibrium molecular dynamics (MD) simulations and eNMR confirm the presence of negatively charged [Li(TFSI) n ] (1−n) aggregates that migrate towards the positive electrode, resulting in negative lithium transference numbers. Equilibrium MD simulations reveal a vehicular Li ion transport mechanism facilitated by long-lived aggregates with Li + cations strongly bound to multiple TFSI − anions. Finally, we observe an inverse relationship between the apparent charge of the TFSI − anion in the neat IL, which is dictated by the IL cation, and Li + transport in the salt-doped systems. This highlights the opportunity to tune electrolyte performance by tailoring cation chemistry.

Li-ion batteries↗

Mechanism of ion pairing–induced co-ion penetration into the stern layer

In classical electric double layer (EDL) theory, co-ions—ions carrying the same charge as the electrode—are assumed to be excluded from the Stern layer because of electrostatic repulsion. However, ion pairing with adsorbed counterions may enable co-ions to access the EDL, a phenomenon that remains underexplored. Key questions therefore remain unresolved, including how deeply co-ions penetrate, how ion-specific properties govern them, and how ion pairing within the EDL differs from bulk solution. Here, in this study, we employ molecular dynamics simulations combined with well-tempered metadynamics to quantify co-ion penetration and ion-pairing thermodynamics at positively charged Mg-Al layered double hydroxide interfaces (σ = +20.6 μC/cm 2 ) in aqueous chloride electrolytes across 0.005–3 M range. We reveal a concentration-driven crossover: at dilute conditions, counterion–co-ion contact ion pairing (CIP) is thermodynamically unfavorable or only weakly favorable (ΔG CIP = +0.12 kcal/mol for Li + to −0.42 kcal/mol for K + ), leading to co-ion exclusion. As concentration increases (≥0.5 M), enhanced screening reduces surface repulsion and stabilizes CIP thermodynamics (ΔG CIP = −0.89 kcal/mol for Li + to −1.05 kcal/mol for K + at 3 M), enabling monovalent co-ions to penetrate the Stern layer following the hydration hierarchy K + > Na + > Li + , while divalent co-ions (Mg 2+ , Ca 2+ ) remain in the diffuse layer, forming only solvent-separated pairs. Comparison with bulk solution shows interfacial ion pairing is suppressed at low concentrations but converges to bulk-like thermodynamics at high concentrations, indicating surface effects vanish under strong screening. These results establish a quantitative framework linking ion-pairing thermodynamics to co-ion penetration and providing strategies to design electrochemical interfaces.

Co-ion penetration↗

Deriving effective electrode–ion interactions from free-energy profiles at electrochemical interfaces

Understanding ion adsorption at electrified metal–electrolyte interfaces is essential for accurate modeling of electrochemical systems. Here, in this study, we systematically investigate the free energy profiles of Na + , Cl − , and F − ions at the Au(111)–water interface using enhanced sampling molecular dynamics with both classical force fields and machine-learned interatomic potentials (MLIPs). Our classical metadynamics results reveal a strong dependence of predicted ion adsorption on the Lennard-Jones parameters, highlighting that—without due care—standard mixing rules can lead to qualitatively incorrect descriptions of ion–metal interactions. We present a systematic methodology for tuning the cross term LJ parameters to control adsorption energetics in agreement with more accurate models. As a surrogate for an ab initio model, we employed the recently released Universal Models for Atoms MLIP, which validates classical trends and displays strong specific adsorption for chloride, weak adsorption for fluoride, and no specific adsorption for sodium, in agreement with experimental and theoretical expectations. By integrating molecular-level adsorption free energies into continuum models of the electric double layer, we show that specific ion adsorption substantially alters the interfacial ion population, the potential of zero charge, and the differential capacitance of the system. Our results underscore the critical importance of force field parameterization and advanced interatomic potentials for the predictive modeling of ion-specific effects at electrified interfaces and provide a robust framework for bridging molecular simulations and continuum electrochemical models.

Roncoroni, Fabrice [Lawrence Berkeley National Lab↗