The Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm (figures I and 2). The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Using an array of ion-specific electrodes (ISEs), cyclic voltammetry, and electrochemical techniques, the chemistry cells will wet soil samples for measurement of basic soil properties of pH, redox potential, and conductivity. Total dissolved material, as well as targeted ions will be detected to the ppm level, including important exobiological ions such as Na, K+, Ca++, Mg++, NH4+, Cl, S04-, HC03, as well as more toxic ions such as Cu++, Pb++, Cd++, Hg++, and C104-. MECA's microscopy station combines optical and atomic-force microscopy (AFM) to image dust and soil particles from millimeters to nanometers in size. Illumination by red, green, and blue LEDs is augmented by an ultraviolet LED intended to excite fluorescence in the sample. Substrates were chosen to allow experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. To aid in the detection of potentially dangerous quartz dust, an abrasion tool measures sample hardness relative to quartz and a hard glass (Zerodur).

Meloy, Thomas P.↗

Electronic Tongue Containing Redox and Conductivity Sensors

The Electronic Tongue (E-tongue 2) is an assembly of sensors for measuring concentrations of metal ions and possibly other contaminants in water. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings, and detecting micro-organisms indirectly by measuring microbially influenced corrosion. The device includes a heater, a temperature sensor, an oxidation/reduction (redox) sensor pair, an electrical sensor, an array of eight galvanic cells, and eight ion-specific electrodes.

Buehler, Martin↗

Electronic Tongue for Quantitation of Contaminants in Water

An assembly of sensors, denoted an electronic tongue, is undergoing development as a prototype of compact devices for use in measuring concentrations of contaminants in water. Thus far, the electronic tongue has been tested on ions of Cu, Zn, Pb, and Fe and shown to respond to concentrations as low as about 10 parts per million. This electronic tongue is expected to be capable of measuring concentrations of other metal ions and organic compounds. Potential uses for electronic tongues include monitoring the chemical quality of water in a variety of natural, industrial, and laboratory settings; detecting micro-organisms indirectly by measuring microbially influenced corrosion; and characterizing compounds of interest to the pharmaceutical and food industries. This version of the electronic tongue includes a heater, a temperature sensor, an array of ion-specific electrodes, an oxidation/ reduction sensor pair, an electrical-conductivity sensor, and an array of galvanic cells, all on one compact ceramic substrate. Special-purpose electronic excitation and readout circuitry for the sensors has also been constructed. The main advantage of the electronic tongue, relative to electrodes of this type used traditionally to assess water quality, is extreme ruggedness. The types of measurements that can be performed by use of the sensors on the electronic tongue are quite varied. The best combination of types of measurements for a given application depends on the specific contaminants that one seeks to detect. Experimental studies to identify such combinations were in progress at the time of reporting the information for this article.

Buehler, Marlin↗

The Spacecraft Water Impurity Monitor, a Framework for the Next Generation Complete Water Analysis System for Crewed Vehicles Beyond the ISS

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. Eventually, missions to the moon, Mars, and beyond will be equipped with analytical capabilities equaling those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. This paper discusses the challenges presented by exploration requirements and the research and development progress toward the goal of a total water analysis system. For organic analysis, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For inorganic analysis, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

water monitoring↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.