SEARCH · Search NASA
Results for “ionomer”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design of Graded Cathode Catalyst Layers with Various Ionomers for Fuel Cell Application
Proton exchange membrane fuel cells (PEMFCs) powered by green hydrogen (H2) have become a promising alternative to conventional hydrocarbon-fueled power generators. Despite technological advancements, further improvements in efficiency, durability, and low-cost production are required for the widespread adoption of PEMFCs. Though numerous approaches to improve PEMFC electrodes have been reported, most strategies utilize a single material set (e.g., one combination of catalyst and ionomer) to improve performance. Alternatively, anisotropic (graded) electrode structures with locally tunable properties may yield superior electrode performance due to improved ionic and gas phase transport. In this work, graded cathode catalyst layers (CCLs) incorporating different ionomers (Nafion D2020, Aquivion D79-25BS, and HOPI) were designed and prepared. Performance screening shows that some of these graded electrode structures have comparable performance to optimized single-ionomer electrode structures (D2020) suggesting some synergistic benefit. Additionally, we show that electrodes with lower equivalent weight (EW) D79 ionomer near the membrane and D2020 ionomer near the gas diffusion media outperformed electrodes with the inverted configuration. Finally, EIS analysis shows some graded ionomer structures (e.g. D79/D2020) have better than expected H+ conductivity, generally leading to better electrode performance. However, further optimization of ionomer content and catalyst ink formulations is needed to improve overall PEMFC performance.
Influence of Pt-Metal Alloy Catalysts with Various Ionomers on Oxygen Reduction Reaction in Fuel Cell Application
Pt-M/C (M = Co, Ni, Mn, etc.) alloy catalysts exhibit superior oxygen reduction reaction (ORR) activity compared to pure Pt/C, leading to a high energy efficiency in hydrogen fuel cells. However, many Pt-M/C alloy catalysts were synthesized and evaluated at the lab scale in model test-bed systems like rotating disc electrodes, which don't always correlate to performance within a fuel cell system; there is a clear need to evaluate catalysts in electrodes that can be prepared at industrially relevant scales to evaluate how factors like ink formulation can greatly affect device-level of fuel cell performance. Herein, three commercial Pt-M/C alloy catalysts (two Pt-Co/C and one Pt-Ni/C) were comprehensively characterized by various techniques. The results show that the average particle sizes of the three catalysts are close to 5 nm; the atomic ratio of Pt/M is around 4; and the M was successfully embedded into Pt lattice, resulting in the positive shift of Pt 4f in XPS spectra and XRD patterns. These catalytic materials were incorporated into 9 different cathode catalyst layers (CCLs) with three kinds of ionomers (Nafion D2020, high oxygen permeability ionomer (HOPI), and Aquivion D79-25BS), and their performance in proton exchange membrane fuel cells (PEMFCs) were investigated. The results demonstrate that the Pt-Co/C catalysts possess a higher mass activity (MA) than Pt-Ni/C; the cathodes with Nafion ionomer provide the highest MA while electrodes with Aquivion ionomer showed the lowest activity, attributed to poor H+ conductivity resulting from suboptimal ionomer incorporation. Finally, these alloys were shown to exceed DOE targets for MA and H2/Air performance reported in the recent publications at beginning of life and after 90k cycle catalyst AST protocol. This study provides valuable performance benchmarks for these materials guiding future Pt-M/C catalyst design and material integration for heavy duty PEMFC applications.
Understanding variation in salamander ionomes: A nutrient balance approach
1. Ecological stoichiometry uses information on a few key biological elements (C, N and P) to explain complex ecological patterns. Although factors driving variation in these elements are well established, expanding stoichiometric principles to explore dynamics of the many other essential elements comprising biological tissues (i.e. the ionome) is needed to determine their metabolic relationships and better understand biological control of elemental flows through ecosystems. 2. Here in this paper, we report observations of ionomic variation in two species of salamander (Ambystoma opacum and A. talpoideum) across ontogenic stages using specimens from biological collections of two wetlands sampled over a 30-year period. This unique data set allowed us to explore the extent of ionomic variation between species, among ontogenic stages, between sites and through time. 3. We found species- and, to a lesser extent, site-specific differences in C, N and P along with 13 other elements forming salamander ionomes but saw no evidence of temporal changes. Salamander ionomic composition was most strongly related to ontogeny with relatively higher concentrations of many elements in adult males (i.e. Ca, P, S, Mg, Zn and Cu) compared to metamorphic juveniles, which had greater amounts of C, Fe and Mn. 4. In addition to patterns of individual elements, covariance among elements was used to construct multi-elemental nutrient balances, which revealed differences in salamander elemental composition between species and sites and changes in elemental proportions across ontogenic development. These multi-elemental balances distinguished among species-site-ontogenic stage groups better than using only C, N and P. 5. Overall, this study highlights the responsiveness of consumer ionomes to life-history and environmental variation while reflecting underlying relationships among elements tied to biological function. As such, ionomic studies can provide important insights into factors shaping consumer elemental composition and for predicting how these changes might affect higher-order ecological processes.
Highly Permeable Perfluorinated Sulfonic Acid Ionomers for Improved Electrochemical Devices: Insights into Structure-Property Relationships
Explore the source record for details and available documents.
Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode
Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.
Three-Electrode Study of Electrochemical Ionomer Degradation Relevant to Anion-Exchange-Membrane Water Electrolyzers
Among existing water electrolysis (WE) technologies, anion-exchange-membrane water electrolyzers (AEMWEs) show promise for low-cost operation enabled by the basic solid-polymer electrolyte used to conduct hydroxide ions. The basic environment within the electrolyzer, in principle, allows the use of non-platinum-group metal catalysts and less-expensive cell components compared to acidic-membrane systems. Nevertheless, AEMWEs are still underdeveloped, and the degradation and failure modes are not well understood. To improve performance and durability, supporting electrolytes such as KOH and K 2 CO 3 are often added to the water feed. The effect of the anion interactions with the ionomer membrane (particularly other than OH – ), however, remains poorly understood. We studied three commercial anion-exchange ionomers (Aemion, Sustainion, and PiperION) during oxygen evolution (OER) at oxidizing potentials in several supporting electrolytes and characterized their chemical stability with surface-sensitive techniques. We analyzed factors including the ionomer conductivity, redox potential, and pH tolerance to determine what governs ionomer stability during OER. Specifically, we discovered that the oxidation of Aemion at the electrode surface is favored in the presence of CO 3 2– /HCO 3 – anions perhaps due to the poor conductivity of that ionomer in the carbonate/bicarbonate form. Sustainion tends to lose its charge-carrying groups as a result of electrochemical degradation favored in basic electrolytes. PiperION seems to be similarly negatively affected by a pH drop and low carbonate/bicarbonate conductivity under the applied oxidizing potential. Furthermore, the insight into the interactions of the supporting electrolyte anions with the ionomer/membrane helps shed light on some of the degradation pathways possible inside of the AEMWE and enables the informed design of materials for water electrolysis.
Evaluating the effect of ionomer chemical composition in silver-ionomer catalyst inks toward the oxygen evolution reaction by half-cell measurements and water electrolysis
The effect of anion exchange ionomer (AEI) chemistry on the kinetics of the oxygen evolution reaction (OER) was systematically studied in both half-cell and single-cell electrolysis experiments. OER was studied in 1 M K 2 CO 3 at 50°C using an array of ionomer-silver catalyst inks deposited on Ni foam. Different ionomer modifications were investigated to optimize the OER performance. The AEI used in this work features a block copolymer backbone of polychloromethylstyrene-b-polycyclooctene-b-polychloromethylstyrene which was functionalized with either benzyltrimethylammonium (TMA) or benzylmethylpiperidinium (MPRD) quaternary ammonium cations. Here, using an MPRD quaternary ammonium cation shifted the rate determining step at high overpotentials, ultimately providing enhanced performance. Increasing the catalyst ink dilution was also found to substantially improve mass activity and catalyst utilization (increase from 35 to 88 A g –1 Ag), likely by reducing the ionomer thickness and decreasing transport resistances. In the final ionomer modification, the Ni foam substrate was leveraged to partially hydrogenate the polycyclooctene midblock to be polyethylene-like at the Ni interface. A significant increase in the electrochemical surface area (Cdl increased from 8.8 to 20.8 mF cm –2 ) and performance (by 47 mA cm –2 or 29 A g –1 Ag) was observed with the incorporation of polyethylene. Kinetic results from half-cell experiments were validated via single-cell anion exchange membrane electrolysis experiments, where the optimized electrode displayed enhanced performance in both 1 M K 2 CO 3 and DI H 2 O.
Advancing ionomer design to boost interfacial and thin-film proton conductivity via styrene-calix[4]arene-based ionomers
Sub-micrometer-thick ion-conducting polymer (ionomer) layers often suffer from poor ionic conductivity at the substrate/catalyst interface. The weak proton conductivity makes the electrochemical reaction at the cathode of proton-exchange-membrane fuel cells sluggish. To address this, here we report on a class of polystyrene-based ionomers having sub-nanometer-sized, sulfonated macrocyclic calix[4]arene-based pendants (PS-calix). In films with thickness comparable to that of ionomer-based binder layers, the conductivity of PS-calix film (~41 mS/cm) is ~13 times higher than that of the current state-of-the-art ionomer, Nafion. We observe a similar improvement in proton conductivity when PS-calix interfaces with Pt nanoparticles, demonstrating the potential of PS-calix in catalyst ink. Leveraging a favorable interfacial chemical composition, PS-calix enhances proton conduction at the film-substrate interface, a shortcoming of Nafion. Moreover, the water in PS-calix films diffuses faster than bulk water and the water confined in Nafion films, suggesting an important role played by sub-nanometer-sized calix[4]arene cavities in creating unique water/ion transport pathways.
Achieving High‐Performance and 2000 h Stability in Anion Exchange Membrane Fuel Cells by Manipulating Ionomer Properties and Electrode Optimization
The primary function of the ionomers that are incorporated into fuel cell electrode catalyst layers is to provide pathways for ion transport between the catalyst active sites and the electrolyte. This is influenced by many variables, including the ion-exchange capacity, water uptake, and molecular weight. In anion exchange membrane fuel cells (AEMFCs), controlling ionomer water uptake is particularly important and tailoring this property in each electrode is an important consideration when looking to maximize cell performance. In this study, three poly(norbornene) tetrablock copolymer ionomers with a range of physical properties are synthesized and incorporated into AEMFC anode and cathode electrodes. Systematic electrode engineering with these ionomers allows the peak power density to be increased by 100% (1.6 W cm -2 → 3.2 W cm -2 ) and the current density at 0.2 V to be increased by 59% (5.9 A cm -2 → 9.4 A cm -2 ). Moreover, the top-performing electrode configuration is tested in an operating AEMFC at the US Department of Energy defined current density of 600 mA cm -2 for 2000 h, showing a record-low voltage decay rate of 15.36 µV h -1 – only 3.65% –a over 2000 h. Here, this work sets a new bar for AEMFCs, reporting the best combination of performance and durability of any AEMFC to date.
Alkaline membrane fuel cells with in-situ cross-linked ionomers
Improving cell performance and durability through both new materials and membrane electrode processing optimization is needed for the commercialization of alkaline membrane fuel cell (AMFC) technologies. In this work, we adopted an in-situ cross-linking strategy of an anion-conducting block copolymer to prepare durable ionomers for use in alkaline membrane fuel cells (AMFCs). Our goal was to use new ionomers and binders with an aim at improving long-term stability of AMFCs, especially at high operation temperatures. At 80 degrees C, AMFCs with in-situ cross-linked ionomers showed promising stability with an operating life time of more than 350 hours at 100 mA/cm(2). We found that the optimized electrode fabrication process and operating conditions can significantly improve the durability performance of AMFCs. For example, a suitable electrode binder in addition to the ion-conducting ionomer can greatly enhance the durability performance of AMFCs. Operating fuel cells under a cathode over-humification condition can also enhance the long-term stability of AMFCs. (C) 2014 Elsevier Ltd. All rights reserved.
Water-induced nanochannel networks in self-assembled block ionomers
Block ionomers cast from solution exhibit solvent-templated morphologies that can be altered by solvent-vapor annealing. When cast from a mixed solvent, a midblock-sulfonated pentablock ionomer self-assembles into spherical ionic microdomains that are loosely connected. Upon exposure to liquid water, nanoscale channels irreversibly develop between the microdomains due to swelling and form a continuous mesoscale network. In this work, we use electron tomography and real-time X-ray scattering to follow this transformation and show that the resultant morphology provides a highly effective diffusive pathway.
Contaminant Cation Effect on Oxygen Transport through the Ionomers of Polymer Electrolyte Membrane Fuel Cells
We characterized the effects of cobalt (Co 2+ ) and other cation contaminants on the oxygen (O 2 ) transport properties of the PFSA ionomer used in polymer electrolyte membrane fuel cells (PEMFCs) and gained insight into the mechanisms by which contaminant cations inhibit O 2 transport. Such cations can be released by alloy catalysts and environmental conditions and pose a significant challenge to maintaining high current density performance with low platinum (Pt) loadings. We used a test cell capable of isolating the ionomer from the membrane electrode assembly (MEA), allowing for O 2 transport resistance (R O2 ) measurements using a limiting current technique. We contaminated ionomer membranes with Li + , Na + , Ni 2+ , Co 2+ , and Ce 3+ and found a general increase in R O2 for increased contamination levels and decreased water activity. In addition, our Co 2+ results indicated distinct concentration-dependent regimes. The other cation-form ionomers allowed us to separate the impacts of ion pair strength, multivalency, and reduced water uptake. We believe that these factors cause a more compressed hydrophilic domain and tortuous O 2 diffusion path, and a commensurate increase in R O2 . Lastly, we studied the impact of Co 2+ on an operating PEMFC and found an increase in R O2 consistent with the results of our isolated membrane tests.
Catalyst-layer ionomer imaging of fuel cells
Investigation of membrane/electrode assembly (MEA) microstructure has become an essential step to optimize the MEA components and manufacturing processes or to study the MEA degradation. For these investigations, transmission electron microscopy (TEM) is a tool of choice as it provides direct imaging of the different components. TEM is then widely used for analyzing the catalyst nanoparticles and their carbon support. However, the ionomer inside the electrode is more difficult to be imaged. The difficulties come from the fact that the ionomer forms an ultrathin layer surrounding the carbon particles and in addition, these two components, having similar density, present no difference in contrast. In this paper, we show how the recent progresses in TEM techniques as spherical aberration (Cs) corrected HRTEM, electron tomography and X-EDS elemental mapping provide new possibilities for imaging this ionomer network and consequently to study its degradation.
Reducing Ohmic Resistances in Membrane Capacitive Deionization Using Micropatterned Ion-Exchange Membranes, Ionomer Infiltrated Electrodes, and Ionomer-Coated Nylon Meshes
Membrane capacitive deionization (MCDI) is an emerging water desalination platform that is compact, electrified, and does not require high-pressure piping. Herein, highly conductive poly(phenylene alkylene) ion-exchange membranes (IEMs) are micropatterned with different surface geometries for MCDI. The micropatterned membranes increase the interfacial area with the liquid stream leading to a 700 mV reduction in cell voltage when operating at constant current (2 mA cm -2 ; 2000 ppm NaCl feed) while improving the energy normalized adsorbed salt (ENAS) value by 1.4 times. Combining the micropatterned poly(phenylene alkylene) IEMs with poly(phenylene alkylene) ionomer-filled electrodes reduces the cell voltage by 1000 mV and improves the ENAS values by 2.3 times relative to the base case. This reduction in cell voltage allows for higher current density operation (i.e., 3–4 mA cm -2 ) . The reduction in cell voltage is ascribed to the ameliorating ohmic resistances related to ion transport at the membrane-process stream interface and in the carbon cloth electrode. Finally, porous ionic conductors are implemented into the spacer channel with flat and micropatterned IEM configurations and ionomer infiltrated electrodes. For the configuration with flat IEMs, the porous ionic conductor improves ENAS values across the current density regime (2–4 mA cm -2 ), while for micropatterned IEMs it gets improved only at 4 mA cm -2 .
Characterization of a Sulfonated Poly(Ionic Liquid) Block Copolymer as an Ionomer for Proton Exchange Membrane Fuel Cells using Rotating Disk Electrode
Ionic liquid (IL) additives to both traditional and advanced oxygen reduction reaction (ORR) electrocatalysts have yielded remarkable improvements in catalyst performance and durability. However, incorporating ILs or IL-modified catalysts into the electrodes of a proton exchange membrane fuel cell (PEMFC) membrane electrode assembly (MEA) has proven to be challenging. Sulfonated poly(ionic liquid) block copolymers (S-PILBCP) present an opportunity to incorporate IL functionality directly into the ionomer, orthogonal to protonic conductivity. Here, we use a rotating disc electrode (RDE) to characterize the interface between a S-PILBCP and Pt catalyst in comparison to Nafion. Catalyst thin films prepared with S-PILBCP show an 80% improvement in the ORR activity over those containing Nafion. Thin films of S-PILBCP also show a significantly reduced degree of poisoning sulfonate adsorption on a Pt(111) surface in comparison to Nafion. Furthermore, these half-cell results provide useful insights that help to highlight the source of the impact of the S-PILBCP on PEMFC MEA performance.
Vibrational Spectroscopy for the Determination of Ionizable Group Content in Ionomer Materials
An approach based on vibrational spectral measurements is described for determining the ionizable group content of ion conducting polymer membrane materials. Aimed at supporting the assessment of membrane stability and wear characteristics, performance is evaluated for attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy, confocal Raman microscopy, and ATR FT-IR microscopy using perfluorinated ionomer membrane standards. One set of ionomer standards contained a sulfonic acid ionizable group and the other a sulfonyl imide group. The average number of backbone tetrafluoroethylene (TFE) units separating the ionizable-group containing side chains was in the range of 7.2–2.1 (sulfonic acid set) and 10.5–4.6 (sulfonyl imide set). A poly(tetrafluoroethylene) (PTFE) sample was included as a blank, representing the limit of zero ionizable group (and maximum TFE) content. Calibration relationships were derived from area-normalized vibrational spectra. For all three methods, calibration models applied to independent spectral measurements of samples predicted the ratio of backbone TFE groups to ionizable groups in the repeat unit ( m) with a standard error of ≤ ±0.3. The confocal Raman and ATR FT-IR microscopy techniques achieved ideal blank responses and the lowest prediction errors, down to m ± 0.1 at the 90% confidence level. With its relative simplicity, low sample size requirements, and potential for quantitative micron-scale spatial mapping of the ionizable group content within a membrane, the approach has application to advancing materials development, including exploratory synthesis, durability and wear assessment, and in situ studies of membrane process.
Suppression of oxygen reduction reaction activity on Pt-based electrocatalysts from ionomer incorporation
Not Available