Search NASA⌕ Search

SEARCH · Search NASA

Results for “island system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Battery Degradation Modeling in Hybrid Power Plants: An Island System Unit Commitment Study: Preprint

As hybrid power plants (HPPs), such as photovoltaic (PV) and battery combinations, become increasingly important in power systems with high renewable energy penetration to address PV variability and ensure grid stability. This paper focuses on the urgent need to model the coordination between PV and battery systems in HPPs while accounting for battery degradation. We present a generation scheduling model that explicitly incorporates PV-battery hybridization in the unit commitment problem. Moreover, the cost function of the HPP scheduling problem endogenously considers battery degradation with adjustable weights to strike a balance between minimizing production costs and prolonging battery life, particularly when providing energy arbitrage and ancillary services. Using a realistic island system simulation, we demonstrate that accounting for battery degradation in the scheduling problem can significantly extend battery life with only minor additional production costs.

battery degradation↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY↗

Visualization of the Oscillatory Dynamics of an Island Power System

In this work, we discuss the design of visualizations for understanding the complex oscillatory dynamics of an island power system with renewable generation sources after the loss of a large oil power plant. As more renewable generation sources are added to power systems, the oscillatory dynamics will change, which requires new visualization techniques to determine causes and strategies to avoid unwanted behaviors in the future. Our approach integrates geographic views, time-series plots, and novel oscillatory-trajectory curves, providing unique insights into the interdependent oscillatory behaviors of multiple state variables and generators over time. By enabling multi-node and multivariate comparisons over time, users can qualitatively determine drivers of oscillations and differences in generator dynamics, which is not possible with other commonly used visualization techniques.

inverters↗

Visualization of the Oscillatory Dynamics of an Island Power System: Preprint

In this work, we discuss the design of visualizations for understanding the complex oscillatory dynamics of an island power system with renewable generation sources after the loss of a large oil power plant. As more renewable generation sources are added to power systems, the oscillatory dynamics will change, which requires new visualization techniques to determine causes and strategies to avoid unwanted behaviors in the future. Our approach integrates geographic views, time-series plots, and novel oscillatory-trajectory curves, providing unique insights into the interdependent oscillatory behaviors of multiple state variables and generators over time. By enabling multi-node and multivariate comparisons over time, users can qualitatively determine drivers of oscillations and differences in generator dynamics, which is not possible with other commonly used visualization techniques.

inverters↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

Shearless effective barriers to chaotic transport induced by even twin islands in nontwist systems

For several decades now it has been known that systems with shearless invariant tori, nontwist Hamiltonian systems, possess barriers to chaotic transport. These barriers are resilient to breakage under perturbation and therefore regions where they occur are natural places to look for barriers to transport. Here we describe a kind of effective barrier that persists after the shearless torus is broken. Because phenomena are generic, for convenience we study the standard nontwist map (SNM), an area-preserving map that violates the twist condition locally in the phase space. The barrier occurs in nontwist systems when twin even period islands are present, which happens for a broad range of parameter values in the SNM. With a phase space composed of regular and irregular orbits, the movement of chaotic trajectories is hampered by the existence of shearless curves, total barriers, and a network of partial barriers formed by the stable and unstable manifolds of the hyperbolic points. Being a degenerate system, the SNM has twin islands and, consequently, twin hyperbolic points. We show that the structures formed by the manifolds intrinsically depend on period parity of the twin islands. For this even scenario the structure that we call a torus free barrier occurs because the manifolds of different hyperbolic points form an intricate chain atop a dipole configuration and the transport of chaotic trajectories through the chain becomes a rare event. This structure impacts the emergence of transport, the escape basin for chaotic trajectories, the transport mechanism, and the chaotic saddle. The case of odd periodic orbits is different: we find for this case the emergence of transport immediately after the breakup of the last invariant curve, and this leads to a scenario of higher transport, with intricate escape basin boundary and a chaotic saddle with nonuniformly distributed points.

classical mechanics↗

Invasive wild pig ( Sus scrofa ) diets on barrier islands in the southeastern United States

BACKGROUND: Biological invasions are a leading cause of reductions in global biodiversity. Islands are particularly sensitive to invasions, which often result in cascading impacts throughout island communities. Wild pigs (Sus scrofa) are globally invasive and pose threats to numerous taxa and ecosystems, particularly for islands where they have contributed to declines of many endemic species. However, the impacts of wild pig diet on the flora and fauna remain understudied in many island systems. RESULTS: We used DNA metabarcoding of wild pig fecal samples to quantify the seasonal diet composition of wild pigs on three barrier islands in the southeastern United States. Wild pigs exhibited a diverse diet dominated by plants, but also including marine and terrestrial animals. The diet composition of plants varied seasonally and between islands. Consumption of invertebrates also changed seasonally, with a shift to coastal invertebrates, particularly crabs, in spring and summer. Vertebrates were found in <10% of samples, but spanned broad taxa including amphibians, fish, mammals, and reptiles. Species consumed by wild pigs indicate that wild pigs use a variety of habitats within barrier islands for foraging, including maritime forests, saltmarshes, and beaches. CONCLUSIONS: An observed shift to beach foraging during sea turtle nesting season suggests wild pigs have potential to hinder nesting success on islands without established management programs. These findings provide insight into the diverse diets of wild pigs on barrier islands and highlight the need for removal of wild pigs from sensitive island ecosystems because of their potential impacts to native plant and animal communities. © 2024 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

60 APPLIED LIFE SCIENCES↗

Tri-Level Linear Programming Model for Automatic Load Shedding Using Spectral Clustering

Traditional load shedding schemes can be inadequate in grids with high renewable penetration, leading to unstable events and unnecessary grid islanding. Although for both manual and automatic operating modes load shedding areas have been predefined by grid operators, they have remained fixed, and may be sub-optimal due to dynamic operating conditions. In this work, a distributed tri-level linear programming model for automatic load shedding to avoid system islanding is presented. Preventing islanding is preferred because it reduces the need for additional load shedding besides the disconnection of transmission lines between islands. This is crucial as maintaining the local generation-demand balance is necessary to preserve frequency stability. Furthermore, uneven distribution of generation resources among islands can lead to increased load shedding, causing economic and reliability challenges. This issue is further compounded in modern power systems heavily dependent on non-dispatchable resources like wind and solar. The upper-level model uses complex power flow measurements to determine the system areas to shed load depending on actual operating conditions using a spectral clustering approach. The mid-level model estimates the area system state, while the lower-level model determines the locations and load values to be shed. The solution is practical and promising for real-world applications.

Baquedano-Aguilar, Mario D.↗

Island influences on plant functional traits and trait–trait associations across species‐ and community‐scales

The island rule predicts gigantism or dwarfism in body size of island species relative to their mainland counterparts. However, whether other functional traits shift and whether trait–trait associations on islands differ between species and community levels remains unclear. We measured 13 carbon- and water-related functional traits in 37 shared tree species across 35 eastern Chinese islands and 66 nearby mainland plots. We examined species-level trait value shifts and associations under the island rule and compared trait associations between species and communities. Most size-related, wood-anatomical, and hydraulic traits shifted on islands, with large values decreasing and small values increasing; yet, their associations remained stable, aligning with the global trait spectrum and trait–trait coevolution. This stability, despite trait value shifts, suggests evolutionary integration of functional strategies. By contrast, island community-scale trait associations diverged from shared species-level patterns and sometimes reversed, such as positive relationships between wood density and resource-acquisitive traits. Community-level trait associations were stronger on islands, likely reflecting constrained environmental filtering and migration limitation. These contrasting patterns suggest that dominant species can restructure trait associations at the community level, with implications for ecosystem functioning and carbon storage, thereby advancing understanding of plant trait strategies in island systems.

Archipelagos↗

Impact of synchronous condensers on fault location and black start in multi-inverter isolated microgrids

Synchronous condensers have been used in power systems for decades, but they are now attracting interest as a potential means for solving certain issues associated with inverter-based resources in islanded power systems. They have been extensively studied in applications to large wind farms and weak grids, but there has been very little study of synchronous condensers in intentionally-islanded systems, and especially self-healing ones. This report documents the results of an LDRD project intended to create modeling tools for use in the study of synchronous condensers in these smaller off-grid systems, and to explore synchronous condensers in this application. The results indicate that synchronous condensers have the potential to provide many benefits, but there are also several unanswered questions and technical challenges requiring further study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commonwealth of the Northern Mariana Islands: Developing a Resilient Power System

The Commonwealth of the Northern Mariana Islands (CNMI) is a chain of 14 islands located in the western Pacifc ocean, roughly 6,000 miles west of the U.S. mainland and 2,000 miles east of China. The economy in CNMI is highly dependent on tourism. CNMI relies on imported petroleum products for both electricity generation and transportation and is consequently sensitive to fluctuations in market prices for fuel. CNMI's aging electricity infrastructure and vulnerability to natural disasters present major challenges and emphasize the territory's need for a more resilient power system.

CNMI↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating Oscillations in Bulb Turbine Plant During Islanded black start Operation

This paper investigates the frequency oscillatory behavior displayed by the bulb turbine-based run-of-river (ROR) hydropower system under islanded operation. These oscillations prevent higher loading of these generators (under islanded conditions) and hence reduce the black start capability of these generators. To investigate the problem, first, a transfer function model of the bulb-turbine system, sensitive to the effects of head variation, blade angle, and other non-linearities pertaining to turbine characteristics is derived. Next, by analyzing this transfer function model and through simulations, it is determined that system inertia along with other parameters could be responsible for these oscillations. Also, through simulations it is shown that the same ROR system’s behavior is different under islanded mode compared to grid-connected mode.

13 HYDRO ENERGY↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗