At least 19 records

Direct-Circulation Stirling-Cycle Refrigerator

In proposed cryogenic system, cold working fluid (helium) circulated directly from Stirling-cycle refrigerator machinery through loop of tubing to provide 15 W of cooling power at temperature of 80 K to scientific instruments or other devices located at some distance from machinery. (Separation of cooled devices from machinery may be dictated by engineering requirements including, need to isolate cooled devices from vibrations of machinery.) Advantages include less complexity, smaller size, lighter weight, and lower power consumption.

Ellison, Woody↗

Cryogenic test rig with an aerodynamic magnetically levitated carriage

The results are presented of the studies which concern the use of a magnetically levitated aerodynamic carriage with a model moving in a closed cryogenic channel. The facility dimensions are established, operating ranges are calculated, thermal isolation, cooling and measurement systems are described, comparison of this facility with wind tunnels is given and its advantages are shown.

Borisov, Sergey YU.↗

Isolation of major Venus thermospheric cooling mechanism and implications for earth and Mars

The additional cooling mechanism responsible for the unexpectedly cold dayside Venus thermosphere is isolated. Consideration is given not only to the condition that the calculated temperatures must be reduced to the observed dayside temperatures but also that the theoretical temperature variations must be in accord with the observed low amplitude of temperature variations associated with the 27-d variations of the sun. It is found that the low amplitude of the 27-d oscillations, combined with the cooling necessary for observed 300-K dayside temperatures, cannot be explained by eddy conduction cooling and can only be explained by very strong 15-micron cooling. Implications of the decrease in amplitude of the 11-yr Venus thermospheric variability due to the 15-micron thermostat effect are examined.

Keating, Gerald M.↗

A cryogenic seven-element HEMT front end for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

Bowen, J.↗

Reverse Brayton Cycle with Bladeless Turbo Compressor for Automotive Environmental Cooling

An automotive cabin cooling system uses a bladeless turbocompressor driven by automobile engine exhaust to compress incoming ambient air. The compressed air is directed to an intercooler where it is cooled and then to another bladeless turbine used as an expander where the air cools as it expands and is directed to the cabin interior. Excess energy may be captured by an alternator couple to the expander turbine. The system employs no chemical refrigerant and may be further modified to include another intercooler on the output of the expander turbine to isolate the cooled cabin environment.

Cepeda-Rizo, Juan↗

Three Stage Cool Flame Droplet Burning Behavior of n-Alkane Droplets at Elevated Pressure Conditions: Hot, Warm and Cool Flame

Transient, isolated n-alkane droplet combustion is simulated at elevated pressure for helium-diluent substituted-air mixtures. We report the presence of unique quasi-steady, three-stage burning behavior of large sphero-symmetric n-alkane droplets at these elevated pressures and helium substituted ambient fractions. Upon initiation of reaction, hot-flame diffusive burning of large droplets is initiated that radiatively extinguishes to establish cool flame burning conditions in nitrogen/oxygen “air” at atmospheric and elevated pressures. However, at elevated pressure and moderate helium substitution for nitrogen ( X He > 20%), the initiated cool flame burning proceeds through two distinct, quasi-steady-state, cool flame burning conditions. The classical “Hot flame ” ( ∼1500 K) radiatively extinguishes into a “Warm flame ” burning mode at a moderate maximum reaction zone temperature ( ∼ 970 K), followed by a transition to a lower temperature ( ∼765 K), quasi-steady “Cool flame ” burning condition. The reaction zone (“flame”) temperatures are associated with distinctly different yields in intermediate reaction products within the reaction zones and surrounding near-field, and the flame-standoff ratios characterizing each burning mode progressively decrease. The presence of all three stages first appears with helium substitution near 20%, and the duration of each stage is observed to be strongly dependent on helium substitutions level between 20–60%. For helium substitution greater than 60%, the hot flame extinction is followed by only the lower temperature cool flame burning mode. In addition to the strong coupling between the diffusive loss of both energy and species and the slowly evolving degenerate branching in the low and negative temperature coefficient (NTC) kinetic regimes, the competition between the low-temperature chain branching and intermediate-temperature chain termination reactions control the “Warm” and “Cool ” flame quasi-steady conditions and transitioning dynamics.

Droplet Combustion↗

Vapor-barrier Vacuum Isolation System

A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

Weinstein, Leonard M.↗

Experimental results for film cooling in 2-D supersonic flow including coolant delivery pressure, geometry, and incident shock effects

An experimental program was conducted to establish some design parameters important to a supersonic film cooling system in a scramjet engine. A simple non-combusting two-dimensional flow configuration was used to isolate the film cooling phenomena. Parameters investigated include coolant delivery pressure, slot height and lip thickness, and incident shock location and strength. Design guidelines for use in engineering and trade studies are presented.

Olsen, George C.↗

Multispecies Biofilm Development on Space Station Heat Exhanger Core Material

Investigations of microbial contamination of the cooling system aboard the International Space Station (ISS) suggested that there may be a relationship between heat exchanger (HX) materials and the degree of microbial colonization and biofilm formation. Experiments were undertaken to test the hypothesis that biofilm formation is influenced by the type and previous exposure of HX surfaces. Acidovorax delafieldii, Comamonas acidovorans, Hydrogenophaga pseudoflava, Pseudomonas stutzeri, Sphingomonas paucimobilis, and Stenotrophomonas maltophilia, originally isolated from ISS cooling system fluid, were cultured on R2A agar and suspended separately in fresh filter-sterilized ISS cooling fluid, pH 8.3. Initial numbers in each suspension ranged from 10(exp 6)-10(exp 7) CFU/ml, and a mixture contained greater than 10(exp 7) CFU/ml. Coupons of ISS HX material, previously used on orbit (HXOO) or unused (HXUU), polycarbonate (PC) and 316L polished stainless steel (SS) were autoclaved, covered with multispecies suspension in sterile tubes and incubated in the dark at ambient (22-25 C). Original HX material contained greater than 90% Ni, 4.5% Si, and 3.2% B, with a borate buffer. For approximately 10 weeks, samples of fluid were plated on R2A agar, and surface colonization assessed by SYBR green or BacLight staining and microscopy. Suspension counts for the PC and SC samples remained steady at around 10(exp 7) CFU/ml. HXUU counts declined about 1 log in 21 d then remained steady, and HXOO counts declined 2 logs in 28 d, fluctuated and stabilized about 10(exp 3) CFU/ml from 47-54 d. Predominantly yellow S. paucimobilis predominated on plates from HXOO samples up to 26 d, then white or translucent colonies of other species appeared. All colony types were seen on plates from other samples throughout the trial. Epifluorescence microscopy indicated microbial growth on all surfaces by 21 d, followed by variable colonization. After 54 d, all but the HXOO samples had well-distributed live and dead cells; the HXOO samples had few cells and most were live by BacLight. The results suggest that HX materials themselves are inhibiting microbial growth on the surfaces. The HX exposed on orbit to cooling system fluid inhibited growth of some species originally isolated from the system, whereas the unused HX material had a moderate effect compared to no inhibition with PC or SS controls. It is possible that chemistry or microbiology of the ISS system increased deposition of inhibitory compounds on the HXOO coupon surfaces; these may inhibit inoculated species to differing degrees.

Pyle, B. H.↗

Bench cooling the Thematic Mapper

The present investigation is concerned with the bench cooling system which was developed in conjunction with the Thematic Mapper (TM), a second-generation earth resources sensor. A small, permanently evacuated dewar, which is carried into space with the instrument, is employed to provide thermal isolation for bench cooling IR detectors of many space-borne instruments. This approach has, however, a number of disadvantages. The system designed for cooling the TM makes, therefore, use of a new approach, involving a temporarily evacuated, take-apart dewar in combination with a temperature-controlled Joule-Thomson cryostat.

Kuyper, D. J.↗

Investigation of a laboratory candidate for the carrier of the 4430 A diffuse interstellar band

The 4430 A diffuse interstellar band (DIB) is unique among DIB's in that as one of the strong bands, it is the bluest strong band with no others observed at shorter wavelengths. This position at the edge of the DIF 'forrest' suggests it may be the easiest to replicate in the laboratory. In earlier experiments (Wdowiak 1980) an interesting candidate using a gas discharge followed by cryogenic matrix isolation was produced, and this report details its further investigation. This absorption feature, produced when 1 part CH4 in 200 parts Ar is discharged and frozen out approximately 10 K, is at a wavelength of 4500 A in the argon matrix. Our recent experiments strongly indicate it is due to a carbon-based reactive species that is stable against mercury vapor UV radiation, and not likely to be from a contaminant. The effect of matrix shift can be estimated by considering the blueward shift between Ar and Ne matrices in the cases of the pyrene and C60 cations. This suggests that a shift from 4500 A for an Af matrix to the vicinity of 4300 A for a Ne matrix and the gas phase is not unreasonable. A liquid He cooled Ne matrix isolation experiment was prepared to determine the wavelength of the feature in that matrix. Replacing CH4 with C2H2 results in an equivalent absorption due to C3, greatly diminished absorptions from C2 and Ch, and no observable feature at 4500 A. To date our experiments indicate CH4 is a favored precursor for production of the reactive carrier of the 4500 A feature. Perhaps C2H2 is not suitable because of its tendency to polymerize easily in the discharge.

Wdowiak, Thomas J.↗

A device for rapid determination of thermophysical properties of phase-change wind-tunnel models

An experimental method for direct measurement of the thermophysical properties of wind tunnel heat transfer models was developed. The technique consists of placing the model under a bank of high intensity, radiant heaters so that the fast opening water cooled shutters, which isolate the heater bank from the model, allow a step-input heat rate to be applied. Measurements of the heat transfer rate coupled with a surface-temperature time history of the same material are sufficient to determine the material thermophysical properties. An infrared thermometer is used to measure model surface temperature and a slug calorimeter provides heat transfer rate information. The output from the infrared thermometer and calorimeter is then fed into an analog-to-digital converter which provides digitized data to a computer. This computer then calculates combined thermophysical properties and a teleprinter prints out all the data. Thus, results are available within 7 minutes of test initiation as opposed to the weeks or months required using prior techniques.

Creel, T. R., Jr.↗

Silicon source for vacuum deposition

Device using two independent silicon sources for ultra-high-vacuum deposition on large substrates can deposit P and N types of silicon simultaneously. Efficient water cooled copper shield supports and cools structure and isolates two filaments.

Racette, G. W.↗

Nucleation and growth of HNO3-3H2O particles in the polar stratosphere

Growth of nitric acid trihydrate (NAT) particles on background stratospheric aerosols is examined for an isolated air parcel cooled at a uniform rate. During the process of nucleation, the saturation ratio of HNO3 vapor reaches a maximum value between 2 and 15, corresponding to supercooling by 1-4 K. If cooling rates exceed 0.5-1 K/day, small particles of NAT are produced. A major fraction of the available condensation nuclei is activated and removal of HNO3 by gravitational settling is slow. If cooling rates are less than 0.5-1 K/day, the number of aerosols that nucleate is reduced, leading to differential growth of large NAT particles. Observations of 5 micron radius particles in clouds at temperatures above the water frost point may reflect condensation of NAT on ice particles that fall through a column of air as it is cooled. Rapid condensation of HNO3 on ice particles is promoted by the high supersaturation attained during nucleation and maintained during subsequent cooling. This process provides a mechanism for irreversible removal of HNO3.

Wofsy, Steven C.↗

Development of radiometer windows for atmospheric entry vehicles

A test program was established to determine the feasibility of developing a radiometer window for stagnation region shock layer atmospheric entry experiments from geosynchronous orbit and with measurements extending into the VUV region to about 170 nm. This test program examined both isolated (uncooled) and cooled window mounting options. Preliminary tests determined the gross suitability of sapphire and fused silica as window materials. Measurements show that the expected maximum temperature (1500 C) is itself not a problem, but that temperature gradients can easily break a window and that the transmission of sapphire and of fused silica at 174 nm drops dramatically at temperatures beyond 800 C and 500 C, respectively. A series of developmental tests showed that the surface of an uncooled fused silica window begins to melt at the entry conditions tested while an uncooled sapphire window generally does not, and that a cooled sapphire window design that keeps the window below 800 C appears possible. The final proof-of-design tests narrowed the selection of possible candidate window sizes and mounting configurations. These tests demonstrate that the best insulated and cooled window designs use small diameter sapphire windows and that thermal modeling codes can be used to assist the design process.

Terrazas-Salinas, Imelda↗

Development of a high-performance cryogenic radiator with V-groove radiation shields

A feasibility demonstration model of a new-technology, high-performance, cryogenic radiative cooler has been successfully tested in a helium-cooled vacuum chamber. Thermal isolation of the radiator cold stage from the warm spacecraft and instrument is achieved by a novel arrangement of lightweight radiation shields which form large V-groove cavities, and by the use of low-conductance structural supports. The vacuum chamber experiments demonstrate the thermal isolation capability of the radiator design. Analytical model predictions are all within 1 K of the measured test temperatures. Utilization of this design enables reasonably sized radiative coolers (less than 0.3 sq m) to achieve operating temperatures below 60 K at earth, Mars, and beyond for useful cooling loads below 75 mW. The design can be scaled to accommodate larger heat loads. The reduction in operating temperature of over 15 K relative to any radiative cooler flown in the past will allow the V-groove isolation radiator to meet the challenging instrument cooling requirements of many future space missions.

Bard, Steven↗