Search NASA⌕ Search

SEARCH · Search NASA

Results for “klystron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Study program for design improvements of the X-3060 klystron. Phase 3: Electron gun fabrication and beam analyzer evaluation. Phase 4: Klystron prototype fabrication and testing

A full scale model was produced to verify suggested design changes. Through beam analyzer study, the correct electron beam diameter and cross sectional profile were established in conjunction with the desired confining magnetic field. Comparative data on the performance of the X-3060 klystron, design predictions for the improved klystron, and performance data taken during acceptance testing of the prototype VKS-8274 JPL are presented.

Goldfinger, A.↗

Design of the klystron filament power supply control system for EAST LHCD

A filament is a critical component of the klystron used to heat the cathode. There are totally 44 klystrons in experimental advanced superconducting tokamak (EAST) lower hybrid current drive (LHCD) systems. All klystron filaments are powered by AC power suppliers through isolated transformers. In order to achieve better klystron preheat, a klystron filament power supply control system is designed to obtain the automatic control of all filament power suppliers. Klystron filament current is measured by PLC and the interlock between filament current and klystron high voltage system is also implemented. This design has already been deployed in two LHCD systems and proves feasible completely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of Giant Amplitude Pulses in a Klystron Chaos Auto-Oscillator

The presented experimental results demonstrate that microwave pulses of giant amplitude are generated in a klystron generator operating in the self-excited mode of chaotic oscillations. The auto-oscillator is assembled using a noisetron scheme that contains two five-cavity floating-drift klystrons serially connected in a ring, one of which operates in the mode of linear signal amplification (the linear klystron) and the other works in the mode of nonlinear signal amplification (the nonlinear klystron). It is established that, at a certain value of the beam current of a nonlinear klystron, intermittency of chaos–chaos type is realized in the auto-oscillation system in the form of chaotic sequences of microwave pulses of giant amplitude formed over the chaotic amplitude background. This type of intermittency is caused by the amplitude bistability of the nonlinear floating-drift klystron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Klynac: An integrated klystron and linear accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

43 PARTICLE ACCELERATORS↗

Design of a multi beam klystron cavity from its single beam parameters

The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

42 ENGINEERING↗

50 KW Multi-beam Klystron

Statement of problem or situation that is being addressed: microwave power sources (such as klystrons) offering an increased efficiency (80% or above) are needed for various applications. Of a particular interest is a source at 952.6 MHz delivering 50kW (continuous) CW for the RF systems for ion acceleration in the Energy Electron Ion Collider EIC being developed at Thomas Jefferson National Accelerator Facility. General statement of how this problem is being addressed: A novel tube (klystron) concept with efficiency in excess of 80%, delivering 50 kW CW at 952.6 MHz MHz is proposed. It is a combination of proven technologies put together: its uses multiple beams to have its perveance low to boost beam-power to RF efficiency. It uses a partially grounded depressed collector (as invented by Omega P R&D) with a carefully tailored beam distribution after the cavity chain to recover energy thereby increasing the overall efficiency even more. A low operating voltage makes the tube more user-friendly avoiding need for costly modulators and oil insulation. A sectioned solenoid is used to insure superb beam-matching to all components downstream of the electron gun, increasing the tube performances. What is to be done in Phase I: The overall goal of this project is to develop, design, engineer, manufacture and test a multi-beam klystron operating in CW regime, delivering 50kW CW of power at 952.6 MHz. The effort is to be coordinated with TJNAF to insure excellent compatibility with the facility. The device will have a high efficiency >80% (operating at 12kV). The main goals during Phase I are to numerically simulate and optimize the klystron main components, namely the gun, the RF cavity chain, the multi-channel-channel partially grounded depressed collector, and the magnetic system. Preliminary engineering issues will be coordinated by Omega-P R&D with its strategic alliance partner Calabazas Creek Research Inc., which expected to participate formally during Phase II in final design and fabrication. Commercial Applications and Other Benefits: The klystrons of this type can serve as the main RF-energy source of in RF-systems for accelerators which have found their applications both in science and industry, and is of high interest to Thomas Jefferson National Accelerator Facility.

RF power sources, klystron, high efficiency, CW, e↗

The Klynac: An Integrated Klystron and Linear Accelerator

The Klynac concept integrates an electron gun, a radio frequency (RF) power source, and a coupled-cavity linear accelerator into a single resonant system. The klystron is essentially a conventional klystron structure with an input cavity, some number of intermediate cavities and an output cavity. The accelerator structure is, likewise, a conventional on-axis coupled structure. The uniqueness is the means of coupling the klystron output cavity to the accelerator. The coupler is a resonant coupler rather than an ordinary transmission line. The geometry of such a system need not be coaxial. However, if the klystron and accelerator are coaxial we can eliminate the need for a separate cathode for the accelerator by injecting some of the klystron beam into the accelerator. Such a device can be made cylindrical which is ideal for some applications.

klystron, linear accelerator, klynac, beam energy,↗

Development of a 10 kW, 2.815 GHz Klystron

Development of a Periodic Permanent Magnet (PPM) focused klystron is described. The klystron was designed to produce 10 kW CW at 2.815 GHz. The program developed an innovative PPM circuit that provided extremely uniform magnetic fields at the electron beam location while providing unprecedented access to the RF circuit for tuners and water cooling. Simulations indicated the klystron would produce more than 11 kW with an efficiency exceeding 65%. Problems with the mechanical design prevented successful testing of the initial prototype; however, a new design was successfully developed and implemented in a 6 MW klystron developed in a follow-on program. Funding is being pursued to rebuild the 10 kW RF circuit and complete the klystron development.

43 PARTICLE ACCELERATORS↗

The 250-kW CW klystron amplifier for planetary radar

The design, construction, and performance testing is described of two Varian klystrons, model VKX-7864A, which replaced the aging and less efficient VA-949J klystrons in the X band planetary radar transmitter on the Goldstone, CA, 70 meter antenna. The project was carried out jointly by the JPL and Varian Assoc. Output power was increased from 200 to 250 kW continuous wave per klystron, and full dc beam power is dissipated in the collector (it was not possible to operate the VA-949J klystrons without RF drive because of limited collector dissipation capability). Replacements were made with a minimum of transmitter modifications. The planetary radar transmitter is now operating successfully with these two klystrons.

Cormier, R.↗

250-kW CW klystron amplifier for planetary radar

The design, construction, and performance testing is described of two Varian klystrons, model VKX-7864A, which replaced the aging and less efficient VA-949J klystrons in the X band planetary radar transmitter on the Goldstone, CA, 70 meter antenna. The project was carried out jointly by the JPL and Varian Assoc. Output power was increased from 200 to 250 kW continuous wave per klystron, and full dc beam power is dissipated in the collector (it was not possible to operate the VA-949J klystrons without RF drive because of limited collector dissipation capability). Replacement were made with a minimum of transmitter modifciations. The planetary radar transmitter is now operating successfully with these two klystrons.

Cormier, Reginald A.↗

SU-E-E-08: Applications of the Quantization of Coupled Circuits in Radiation Physics (design of Klystron, Bremsstrahlung, Synchrotron)

Purpose: During the past decade the quantization of coupled/forced electromagnetic circuits with or without Ohm’s resistance has gained the subject of some fundamental studies, since even problems of quantum electrodynamics can be solved in an elegant manner, e.g. the creation of quantized electromagnetic fields. In this communication, we shall use these principles to describe optimization procedures in the design of klystrons, synchrotron irradiation and high energy bremsstrahlung. Methods: The base is the Hamiltonian of an electromagnetic circuit and the extension to coupled circuits, which allow the study of symmetries and perturbed symmetries in a very apparent way (SU2, SU3, SU4). The introduction resistance and forced oscillators for the emission and absorption in such coupled systems provides characteristic resonance conditions, and atomic orbitals can be described by that. The extension to virtual orbitals leads to creation of bremsstrahlung, if the incident electron (velocity v nearly c) is described by a current, which is associated with its inductivitance and the virtual orbital to the charge distribution (capacitance). Coupled systems with forced oscillators can be used to amplify drastically the resonance frequencies to describe klystrons and synchrotron radiation. Results: The cross-section formula for bremsstrahlung given by the propagator method of Feynman can readily be derived. The design of klystrons and synchrotrons inclusive the radiation outcome can be described and optimized by the determination of the mutual magnetic couplings between the oscillators induced by the currents. Conclusions: The presented methods of quantization of circuits inclusive resistance provide rather a straightforward way to understand complex technical processes such as creation of bremsstrahlung or creation of radiation by klystrons and synchrotrons. They can either be used for optimization procedures and, last but not least, for pedagogical purposes with regard to a qualified understanding of radiation physics for students.

43 PARTICLE ACCELERATORS↗

Development and Production of a 201 MHz, 5.0 MW Peak Power Klystron

Communications & Power Industries LLC has designed and manufactured the VKP-8201A, a high peak power, high gain, VHF band klystron. The klystron operates at 201.25 MHz, with 5.0 MW peak output power, 34 kW average output power, and a gain of 36 dB. The klystron is designed to operate between 1.0 MW and 4.5 MW in the linear range of the transfer curve. The klystron utilizes a unique magnetic field which enables the use of a proven electron gun design with a larger electron beam requirement. Experimental and predicted performance data are compared.

43 PARTICLE ACCELERATORS↗