Search NASA⌕ Search

SEARCH · Search NASA

Results for “large field of view”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Large Field of View Shadowgraph System for a 16 Ft. Transonic Wind Tunnel

A large field of view shadowgraph flow visualization system for the Langley 16 ft. Transonic Tunnel (16 ft.TT) has been developed to provide fast, low cost, aerodynamic design concept evaluation capability to support the development of the next generation of commercial and military aircraft and space launch vehicles. Key features of the 16 ft. TT shadowgraph system are: (1) high resolution (1280 X 1024) digital snap shots and sequences; (2) video recording of shadowgraph at 30 frames per second; (3) pan, tilt, & zoom to find and observe flow features; (4) one microsecond flash for freeze frame images; (5) large field of view approximately 12 X 6 ft; and (6) a low maintenance, high signal/noise ratio, retro-reflective screen to allow shadowgraph imaging while test section lights are on.

Talley, Michael A.↗

Optical device enables small detector to see large field of view

Optical device images the sun on a mask that transmits it or prevents its transmission to a photodetector behind the mask depending on image position on the mask. The device uses a pinhole as the image former to provide a large field of view and diffraction-limited resolution.

Arndt, J. H.↗

KD2PO4 Polarization Modulator With Large Field Of View

Improved potassium dideuterium phosphate (KD2PO4) electro-optical linear-polarization modulator suitable for use with optical instruments having large (wide-angle) fields of view. Errors previously caused by convergence of light eliminated.

West, Edward A.↗

High-Resolution Large-Field-of-View Three-Dimensional Hologram Display System and Method Thereof

A real-time, dynamic, free space-virtual reality, 3-D image display system is enabled by using a unique form of Aerogel as the primary display media. A preferred embodiment of this system comprises a 3-D mosaic topographic map which is displayed by fusing four projected hologram images. In this embodiment, four holographic images are projected from four separate holograms. Each holographic image subtends a quadrant of the 4(pi) solid angle. By fusing these four holographic images, a static 3-D image such as a featured terrain map would be visible for 360 deg in the horizontal plane and 180 deg in the vertical plane. An input, either acquired by 3-D image sensor or generated by computer animation, is first converted into a 2-D computer generated hologram (CGH). This CGH is then downloaded into large liquid crystal (LC) panel. A laser projector illuminates the CGH-filled LC panel and generates and displays a real 3-D image in the Aerogel matrix.

Chao, Tien-Hsin↗

Design and simulation of multilayer coatings for a multi-channel Wolter-like x-ray imager with large field of view and high resolution

X-ray diagnostics are key instruments for understanding the physics behind inertial confinement fusion experiments. We report on the multilayer design optimization for the Toroidal X-ray Imager (TXI), a hard x-rays microscope instrument designed by Commissariat à l’énergie atomique (CEA) and Laboratoire Charles Fabry (LCF) to be installed on the National Ignition Facility. TXI includes six channels designed for three different energy bands centered on 8.7, 13, and 17.5 keV. Each channel is made up of two toroidal mirrors arranged in a Wolter-like configuration. The required field of view is 800 × 400 µm2, and the resolution should be better than 5 µm. In addition, we seek to estimate the spatial distribution of the temperature, which requires no spectral overlap of the different energy bands and a good spectral homogeneity of the image produced. The development of the multilayer coatings was performed in a two-step method. First, the coatings were optimized to obtain proper energy bands. Then, an x-ray tracing code was used to calculate the integrated optical response of each channel and adjust the response of the mirror to fulfill the requirements. To fulfill all the specifications, we propose an original design using a combination of two aperiodic coatings, one with a narrow bandwidth and the other one with a larger bandwidth.

hard x-rays↗

High-Resolution Large Field-of-View FUV Compact Camera

The need for a high resolution camera with a large field of view and capable to image dim emissions in the far-ultraviolet is driven by the widely varying intensities of FUV emissions and spatial/temporal scales of phenomena of interest in the Earth% ionosphere. In this paper, the concept of a camera is presented that is designed to achieve these goals in a lightweight package with sufficient visible light rejection to be useful for dayside and nightside emissions. The camera employs the concept of self-filtering to achieve good spectral resolution tuned to specific wavelengths. The large field of view is sufficient to image the Earth's disk at Geosynchronous altitudes and capable of a spatial resolution of >20 km. The optics and filters are emphasized.

Spann, James F.↗

Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

Jenkins, Luther N.↗

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters↗

Attitude Estimation for Large Field-of-View Sensors

The QUEST measurement noise model for unit vector observations has been widely used in spacecraft attitude estimation for more than twenty years. It was derived under the approximation that the noise lies in the tangent plane of the respective unit vector and is axially symmetrically distributed about the vector. For large field-of-view sensors, however, this approximation may be poor, especially when the measurement falls near the edge of the field of view. In this paper a new measurement noise model is derived based on a realistic noise distribution in the focal-plane of a large field-of-view sensor, which shows significant differences from the QUEST model for unit vector observations far away from the sensor boresight. An extended Kalman filter for attitude estimation is then designed with the new measurement noise model. Simulation results show that with the new measurement model the extended Kalman filter achieves better estimation performance using large field-of-view sensor observations.

Cheng, Yang↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Gamma Ray Source Localization for Time Projection Chamber Telescopes Using Convolutional Neural Networks

Diverse phenomena such as positron annihilation in the Milky Way, merging binary neutron stars, and dark matter can be better understood by studying their gamma ray emission. Despite their importance, MeV gamma rays have been poorly explored at sensitivities that would allow for deeper insight into the nature of the gamma emitting objects. In response, a liquid argon time projection chamber (TPC) gamma ray instrument concept called GammaTPC has been proposed and promises exploration of the entire sky with a large field of view, large effective area, and high polarization sensitivity. Optimizing the pointing capability of this instrument is crucial and can be accomplished by leveraging convolutional neural networks to reconstruct electron recoil paths from Compton scattering events within the detector. In this investigation, we develop a machine learning model architecture to accommodate a large data set of high fidelity simulated electron tracks and reconstruct paths. We create two model architectures: one to predict the electron recoil track origin and one for the initial scattering direction. We find that these models predict the true origin and direction with extremely high accuracy, thereby optimizing the observatory’s estimates of the sky location of gamma ray sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The STAR-X X-Ray Telescope Assembly (XTA)

The Survey and Time-domain Astrophysical Research eXplorer (STAR-X) science goals are to discover what powers the most violent explosions in the Universe, understand how black holes grow across cosmic time and mass scale, and measure how structure formation heats the majority of baryons in the Universe. To achieve these goals, STAR-X requires a powerful X-ray telescope with a large field of view, large collecting area, and excellent point spread function. The STAR-X instrument, the X-Ray Telescope Assembly (XTA), meets these requirements using a powerful X-ray mirror technology based on precision-polished single crystal silicon and a mature CCD detector technology. The XTA is composed of three major subsystems: an X-ray Mirror Assembly (MA) of high resolution, lightweight mirror segments fabricated out of single crystal silicon; a Focal Plane Assembly (FPA) made of back-illuminated CCD's capable of detecting X-rays with excellent quantum efficiency; and a composite Telescope Tube that structurally links the MA and FPA. The MA consists of 5,972 silicon mirror segments mounted into five subassemblies called meta-shells. A meta-shell is constructed from an annular central structural shell covered with interlocking layers of mirror segments. This paper describes the requirements, design, and analysis of the XTA subsystems with particular focus on the MA.

NGXO↗

A large field-of-view high-resolution hard x-ray microscope using polymer optics

Here, we present an effective approach using a matched pair of polymer-based condenser-objective lenses to build a compact full-field X-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross-section is used for uniformly illuminating samples over a large field of view (FoV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wave-front distortions. Using a specific lens-pair designed for 20 keV X-rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FoV, 80 × 80 µm 2 in extent. The results were contrasted with those collected under illumination using commercial two-dimensional parabolic lenses with a smaller FoV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of ‘mesoscopic’ phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

47 OTHER INSTRUMENTATION↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

Model studies of the beam-filling error for rain-rate retrieval with microwave radiometers

Low-frequency (less than 20 GHz) single-channel microwave retrievals of rain rate encounter the problem of beam-filling error. This error stems from the fact that the relationship between microwave brightness temperature and rain rate is nonlinear, coupled with the fact that the field of view is large or comparable to important scales of variability of the rain field. This means that one may not simply insert the area average of the brightness temperature into the formula for rain rate without incurring both bias and random error. The statistical heterogeneity of the rain-rate field in the footprint of the instrument is key to determining the nature of these errors. This paper makes use of a series of random rain-rate fields to study the size of the bias and random error associated with beam filling. A number of examples are analyzed in detail: the binomially distributed field, the gamma, the Gaussian, the mixed gamma, the lognormal, and the mixed lognormal ('mixed' here means there is a finite probability of no rain rate at a point of space-time). Of particular interest are the applicability of a simple error formula due to Chiu and collaborators and a formula that might hold in the large field of view limit. It is found that the simple formula holds for Gaussian rain-rate fields but begins to fail for highly skewed fields such as the mixed lognormal. While not conclusively demonstrated here, it is suggested that the notionof climatologically adjusting the retrievals to remove the beam-filling bias is a reasonable proposition.

Ha, Eunho↗

Large field-of-view KD*P modulator

This paper describes how FOV errors have affected the polarization measurements of the NASA Marshall vector magnetograph and how a polarimeter has been modified to minimize these errors. The design of a large-FOV (LFOV) KD*P modulator is discussed. The Poincare sphere is used to visualize the function of the different optical elements that make up the LFOV modulator.

West, E. A.↗