Search NASA⌕ Search

SEARCH · Search NASA

Results for “large load modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Particle Swarm Optimization of Dynamic Load Model Parameters in Large Systems

This paper considers two dynamic load models that are widely used in industry to account for induction motor behavior: CMLD and CLOD. These models must be parametrized for the specific utility system in a general way so that they can be used in planning studies and provide a conservative but realistic representation of load behavior. This study considers a measurement-based approach to tuning both models. The load modeling study compares the response of the tuned models to generic candidate models using historical events. This study considers one area-based subsystem to simplify the modeling approach and reduce the number of models required for simulations. Additionally, because dynamic load models often produce similar results for different sets of parameters, a sensitivity study was conducted to assess the parameter impacts on the voltage response. The sensitivity study covers the parameters that are tuned using event measurements. The process to estimate the parameters uses the particle-swarm optimization algorithm. Overall, the performance of the tuned model more accurately captures recovery voltage, delayed recovery, and settling voltage than its predecessor models while not being overly tuned so that it remains general for peak summer conditions.

dynamic load modeling↗

Open-Source High-Fidelity Aggregate Composite Load Models of Emerging Load Behaviors for Large-Sale Analysis

The goal of this project is to accurately model the dynamic loads for power system planning and operation and to address the challenges inherent in such modeling. Existing load models are inadequate to handle the increasing proliferation of residential air conditioner loads and distributed energy resources, the emerging trends of price-responsive demand, and the growing importance of protective devices in equipment and buildings. A need has emerged to develop a fundamentally new class of load models and next-generation data tools. This work proposes to develop a set of regional–level, scalable open source load models and tools, including large-scale aggregate load protection, concept of price responsive demand, advanced load composition data, next-generation load model data tools, and advanced composite load model calibration and validation frameworks to address new challenges in the representation of next-generation load models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A large deformation multiphase continuum mechanics model for shock loading of soft porous materials

A large deformation, coupled finite-element (FE) model is developed to simulate the multiphase response of soft porous materials subjected to high strain-rate loading. The approach is based on the theory of porous media (TPM) at large deformations. Simplifications to the one-dimensional regime studied in the numerical simulations follow. An overview of several different time integration schemes is presented for the purpose of solving the nonlinear dynamic coupled balance of momenta (mixture and fluid) and balance of mass of the mixture equations. Numerical examples are presented for (i) verification against closed-form analytical solutions assuming small loads, (ii) demonstrating large deformation effects at high strain-rate, and (iii) showing differences in deformations between a single-phase elastodynamics model with occluded compressible pore fluid and a multiphase poroelastodynamics model at high strain-rate. The multiphase model shows that the relative motion of the pore fluid significantly dampens the deformation response of the solid skeleton as compared to the single-phase model, and makes it possible to extract quantitative values for the stresses of the different constituents, thereby allowing one to form preliminary conclusions about the onset of damage in the solid skeleton. The novelty of the current work is developing a multiphase, large deformation, mixture theory numerical model for high strain-rate loading of soft porous materials. It was discovered that explicit, adaptive time-stepping Runge–Kutta schemes offer high accuracy at relatively low cost when compared to traditional implicit or explicit central difference time-stepping schemes for shock-like loadings. Here, shock viscosity is added to the mixture momentum balance equation to regularize the shock front, and a stabilization term is added to the mixture mass balance equation to stabilize equal order interpolation finite elements for the coupled finite element solution of multiphase materials.

Engineering↗

High-Fidelity Large-Signal Order Reduction Approach for Composite Load Model

With the increasing penetration of electronic loads and distributed energy resources, conventional load models cannot capture their dynamics. Therefore, a new comprehensive composite load model is developed by Western Electricity Coordinating Council (WECC). However, this model is a complex high-order non-linear system with multi-time-scale property, which poses challenges on power system studies with heavy computational burden. In order to reduce the model complexity, the authors firstly develop a large-signal order reduction (LSOR) method using singular perturbation theory. In this method, the fast dynamics are integrated into the slow ones to preserve transient characteristics of the former. Then, accuracy assessment conditions are proposed and embedded into the LSOR to improve and guarantee the accuracy of reduced-order model. Finally, the reduced-order WECC composite load model is derived by using the proposed algorithm. Overall, simulation results show that the reduced-order large-signal model significantly alleviates the computational burden while maintaining similar dynamic responses as the original composite load model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling occupancy-driven building loads for large and diversified building stocks through the use of parametric schedules

Building energy modeling provides a fundamental tool to assess the potential for energy efficiency to contribute to reducing world energy consumption and global emissions. Occupancy-related operations are a key source of uncertainty for building energy analysis, particularly for aggregated building stocks. At a district or city level, it is critical to estimate aggregated power load profiles for sizing power grid infrastructure, power plant capacity allocation, and energy efficiency measures. The stochastic nature of behavior-related operations complicates the creation of models that accurately capture building load profiles for entire building stocks. This research introduces a new methodology called parametric schedules to model occupancy-driven schedules for large and diverse building stocks. In contrast to computationally expensive methodologies proposed in the literature, our work does not use a recursive time-consuming step. Occupancy is estimated by the extrapolation of operation times directly from metered electric consumption data; occupancy-related schedules are stochastically assigned to each building model, guaranteeing diversity of operation times in the stock. Our procedure has been tested on a large, diversified data-set of 25,000 commercial buildings in Los Angeles, California. It proved to be able to adequately represent the stochastic schedules diversity of the stock and to refine the stock calibration process by 1%. This innovative approach represents a useful asset for utility companies, grid operators, urban planners, and balancing authorities, seeking to improve building stock modeling and better estimate the impact of energy conservation measures. – This work is part of a larger stock modeling tool called ComStock, which is under development by NREL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Large Load Impacts to Distribution System Hosting Capacity

This work examined the impact of large loads on utility distribution system models using the Sandia-developed open-source software DREAMS. It was shown that hosting capacity varies with location and changes after any asset is added to, or removed from, a system. Despite the tested models having similar rated voltages and other characteristics, their thermal and voltage constrained hosting capacity varied over 2 MW. The addition of a 3-phase balanced constant power large load with power factor of 1.0 exhibited non-linear reductions to all voltage constrained hosting capacities. The reductions to thermal constrained hosting capacity from a load with similar characteristics was more linear, related to the size of the added load, and did not impact all model buses. Co-located capacitors were shown to accommodate demand that was beyond the baseline voltage constrained hosting capacity limits, however, the costs and benefits from this approach were found to not be 1:1 and required additional available thermal capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services

Flexible loads have great potential to improve the electric grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. This paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environmental impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

DRDMannTurb: A Python package for scalable, data-driven synthetic turbulence

Synthetic turbulence models (STMs) are used in wind engineering to generate realistic flow fields and are employed as inputs to industrial wind simulations. Examples include prescribing inlet conditions in large eddy simulations that model loads on wind turbines and tall buildings. We are interested in STMs capable of generating fluctuations based on prescribed second-moment statistics since such models can simulate environmental conditions that closely resemble on-site observations. To this end, the widely used Mann model (see Mann, 1994, 1998) is the inspiration for DRDMannTurb. The Mann model is described by three physical parameters: a magnitude parameter influencing the global variance of the wind field and corresponding to the Kolmogorov constant multiplied by the rate of viscous dissipation of the turbulent kinetic energy to the two-thirds, αϵ 2/3 , a turbulence length scale parameter L, and a nondimensional parameter Γ related to the lifetime of the eddies. A number of studies, as well as international standards (e.g., those by the International Electrotechnical Commission (IEC)), include recommended values for these three parameters with the goal of standardizing wind simulations according to observed energy spectra. Yet, having only three parameters, the Mann model faces limitations in accurately representing the diversity of observable spectra. This Python package enables users to extend the Mann model and more accurately fit field measurements through flexible neural network models of the eddy lifetime function. Following Keith et al. (2021), we refer to this class of models as Deep Rapid Distortion (DRD) models. DRDMannTurb also includes a general module implementing an efficient method for synthetic turbulence generation based on a domain decomposition technique. This technique is also described in Keith et al. (2021).

17 WIND ENERGY↗

A cross-dimensional analysis of data-driven short-term load forecasting methods with large-scale smart meter data

Electricity load forecasting is essential to utility operation and power grid stability. A wide spectrum of data-driven methods, ranging from linear regression models to more recent deep learning models have been adopted to forecast electric load over the years. However, there still lacks a holistic evaluation of the applicability of conventional statistical and machine learning based algorithms with respect to different temporal and spatial scopes, computational requirements, and sensitivity of model-tuning. Enabled by a large-scale electricity load profile dataset of over 40,000 residential customers in a utility region, we conducted a cross-dimensional analysis of data-driven load forecasting methods. Three regression-based and seven deep learning algorithms with different model configurations were evaluated in terms of their overall and peak load prediction accuracy, and training burdens, across spatial aggregation levels ranging from the transformer, feeder, substation, to neighborhood. We found, first, the load forecasting accuracy is constrained by a predictability boundary, influenced by the forecasting horizon and spatial aggregation level. Specifically, RandomForest, XGBoost, TFT, TSMixer, and TiDE models achieved less than 10 % prediction error for up to 96-h ahead forecasting for district, substation, and feeder levels, while other models struggle at long-horizon predictions; Second, for winter and summer peak load dates, most models were able to predict the peak demand timing within ± 1 h, but the prediction percentage error varied by models, with TFT and TiDE models being the top performers; Third, models with similar prediction accuracy can differ in training burden by an order of magnitude. Therefore, choosing model configurations that balance prediction performance and computational resource is an important practical consideration for large-scale deployment of the machine learning based load forecasting. The outcome of this study can guide researchers and practitioners to choose the proper load forecasting algorithms based on their problem scope, required accuracy, and available resources. The predictability boundary can serve as a benchmark for electricity load forecasting problems with new algorithms and datasets.

Li, Han↗

Comparison of three DWM-based wake models at above-rated wind speeds

In this study we investigate three mid-fidelity wind turbine wake models based on the dynamic wake meandering (DWM) model principle, and compare their performance with a reference dataset, produced with large-eddy simulations using the actuator line model. The models are compared with respect to flow field, power, and loads on a row of four 5MW reference turbines experiencing above-rated wind conditions. In general, the DWM models show fairly good agreement with large-eddy simulation for the time-averaged flow fields, blade forces and power, with increasing differences along the turbine row. Also when comparing fatigue loads of blade root moments, the differences between the models increase further into the row, with deviations up to 25 % of the reference case. However, while the development in blade root moment fatigue along the turbine row is predominantly driven by the energy content at the frequency corresponding to the turbine's rotational period (1 P ) for the DWM models, the large-eddy simulation results suggest that the key drivers for the blade root and tower loads are the increase in meandering and energy at higher frequencies (> 1 P ) deeper into the turbine row. For the tower loads, the DWM models highly underestimate the fatigue for the waked turbines. From these results, we suggest priorities for future model developments so that robust model implementations can be used in wind farm design and operation.

17 WIND ENERGY↗

Numerical Modeling of a Two-Stage Ocean Current Turbine

The Equinox Ocean Turbines (EQOT) current energy converter has a unique design with power generation in two small-diameter turbines attached to the tips of a large-diameter passive rotor. This configuration offers some key advantages for capturing ocean currents. With no centrally placed generator, almost no reaction torque is required at the nacelle of the main large-diameter rotor, and the small-diameter tip turbine generators operate at a higher speed and lower torque. The physics that determine the performance and loads on the turbine are also unique. The interactions of the flow field between the two stages and the general architecture of the system cannot be captured with traditional mid-fidelity modeling tools. For design iterations and large sets of load cases, it is important to have mid-fidelity models that can capture the important phenomenon with enough accuracy to identify global trends. This work uses a limited set of high-fidelity computational fluid dynamics (CFD) simulations to help inform the selection of and construction of a custom mid-fidelity model. Mid-fidelity modeling approaches were verified by comparing key turbine performance quantities to those found with the CFD model. Hydrodynamic interactions of the two-stage rotor were identified through high-fidelity CFD modeling. This highlighted the impact of the main rotor tip vortex and wake on the secondary rotor apparent inflow. This results in a relative flow rotation and sharp deficit, that change the optimal secondary rotor rotation speed and adds unsteadiness to the blade loading respectively. Multiple mid-fidelity approaches were evaluated for their ability to capture these effects. A simple approximation of the combined-stage performance based on single-stage BEM provides a reasonable rough prediction, especially near the peak TSR values, with some larger discrepancy at higher TSRs. Predicting the combined-stage performance based on single-stage CFD data improves this prediction across the TSR range. Although the combined-stage modeling in OLAF was not successful in this stage of the project, it showed promise as a mid-fidelity method, assuming the parameters can be tuned to account for the significant differences in time and length scales between the main and secondary rotors. This may be addressed through code changes in future work. A significant finding from the OLAF work was the agreement between the vortex core radius values found independently via a parameter space search and via CFD. The technique of using single-stage secondary rotor BEM, with a custom inflow taken from single-stage main rotor CFD or OLAF, provides an efficient method to capture one-way coupled flow interactions. This method provided generally good predictions of the impact of the flow rotation on the secondary rotor but struggled to accurately predict the peaks of the unsteady load progression. Future work could include some superposition of a tuned main rotor trailing edge viscous wake into the custom inflow to better predict this interaction.

16 TIDAL AND WAVE POWER↗

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science↗