Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of plasma temperature and density using laser absorption

A laser radiation absorption technique, suitable for temporal measurement of the electron density, the temperature, or a simultaneous determination of both, in an LTE plasma, is discussed. The theoretical calculation of the absorption coefficient for a hydrogen plasma is outlined; some results are presented for visible wavelengths. Measurements of electron density and temperature are presented and shown to be in good agreement with those values obtained by other methods. Finally, the possible use of the argon ion laser for simultaneous electron density and temperature measurement is discussed, and the theoretical curves necessary for its application to hydrogen plasma diagnostics are shown.

Billman, K. W.↗

Time-Resolved O3 Chemical Chain Reaction Kinetics Via High-Resolution IR Laser Absorption Methods

Excimer laser photolysis in combination with time-resolved IR laser absorption detection of OH radicals has been used to study O3/OH(v = 0)/HO2 chain reaction kinetics at 298 K, (i.e.,(k(sub 1) is OH + 03 yields H02 + 02 and (k(sub 2) is H02 + 03 yields OH + 202). From time-resolved detection of OH radicals with high-resolution near IR laser absorption methods, the chain induction kinetics have been measured at up to an order of magnitude higher ozone concentrations ([03] less than or equal to 10(exp 17) molecules/cu cm) than accessible in previous studies. This greater dynamic range permits the full evolution of the chain induction, propagation, and termination process to be temporally isolated and measured in real time. An exact solution for time-dependent OH evolution under pseudo- first-order chain reaction conditions is presented, which correctly predicts new kinetic signatures not included in previous OH + 03 kinetic analyses. Specifically, the solutions predict an initial exponential loss (chain "induction") of the OH radical to a steady-state level ([OH](sub ss)), with this fast initial decay determined by the sum of both chain rate constants, k(sub ind) = k(sub 1) + k(sub 2). By monitoring the chain induction feature, this sum of the rate constants is determined to be k(sub ind) = 8.4(8) x 10(exp -14) cu cm/molecule/s for room temperature reagents. This is significantly higher than the values currently recommended for use in atmospheric models, but in excellent agreement with previous results from Ravishankara et al.

Kulcke, Axel↗

Monitoring complex trace-gas mixtures by long-path laser absorption spectrometry

Laser-based spectrophotometric methods, which have been proposed for the detection of trace concentrations of gaseous contaminants, include Raman and passive radiometry. The paper discusses a simple long-path laser absorption method which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels. A number of species were selected which are most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Absorption coefficients at CO2 laser wavelengths were measured, accurate to + 3 per cent or better, for each of these species. This data base was then used to determine the presence and concentration of the contaminants in prepared mixtures of 12 to 15 gases. Computer programs have been developed which will permit a real-time analysis of the monitored atmosphere. Minimum detectable concentrations for individual species are generally in the ppm range, and are not seriously degraded by interferences even in complex mixtures. Estimates of the dynamic range of this monitoring technique for various system configurations and comparison with other methods of analysis are discussed

Green, B. D.↗

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an infrared laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.↗

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an IR laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.↗

Monitoring spacecraft atmosphere contaminants by laser absorption spectroscopy

Laser-based spectrophotometric methods which have been proposed for the detection of trace concentrations of gaseous contaminants include Raman backscattering (LIDAR) and passive radiometry (LOPAIR). Remote sensing techniques using laser spectrometry are presented and in particular a simple long-path laser absorption method (LOLA), which is capable of resolving complex mixtures of closely related trace contaminants at ppm levels is discussed. A number of species were selected for study which are representative of those most likely to accumulate in closed environments, such as submarines or long-duration manned space flights. Computer programs were developed which will permit a real-time analysis of the monitored atmosphere. Estimates of the dynamic range of this monitoring technique for various system configurations, and comparison with other methods of analysis, are given.

Steinfeld, J. I.↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O2was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M Weisberger↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O 2 was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M. Weisberger↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation was developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. Rate constants for dominant reactions were inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Decomposition of NO studied by infrared emission and CO laser absorption

A diagnostic technique for monitoring the concentration of NO using absorption of CO laser radiation has been developed and applied in a study of the decomposition kinetics of NO. Simultaneous measurements of infrared emission by NO at 5.3 microns were also made to validate the laser absorption technique. The data were obtained behind incident shocks in NO-N2O-Ar (or Kr) mixtures, with temperatures in the range 2400-4100 K. The rate constant for the dominant reaction of O and NO to yield N and O2 was inferred from comparisons with computer simulations of the reactive flow.

Hanson, R. K.↗

Tunable-diode laser absorption spectrometry

Tunable-diode laser absorption spectrometry (TDLAS) affords a number of advantages for atmospheric measurements. It is a universal method, applicable, in principle, to all gases of atmospheric interest. Because of its extremely high spectral resolution it provides unequivocal identification of the target species, with no interferences from other gases. It provides real-time, in situ measurements with time resolutions better than 1 minute. The sensitivity of the current TDLAS system is marginally capable of measuring HO2. This species exists in the troposphere at concentrations which are up to 2 orders of magnitude higher than those of HO and, in addition, is much less susceptible to removal by the surfaces of the instrument and its sampling system. HO2 is an important HO sub x species in its own right but can also give direct information on the HO concentration by virtue of the rapid partitioning between these two species. The addition of the high-frequency modulation technique to the TDLAS system would ensure its ability to measure HO2 under most atmospheric conditions. The ability of the TDLAS to measure hydrogen peroxide (H2O2) in the ambient atmosphere was also demonstrated. H2O2 measurements give a clear indication of HO sub x mixing ratios and are also important as a photolytic source of HO and as an important oxidant for other atmospheric consitituents such as SO2.

Schiff, H. I.↗

Monitoring Temperature in High Enthalpy Arc-heated Plasma Flows using Tunable Diode Laser Absorption Spectroscopy

A tunable diode laser sensor was designed for in situ monitoring of temperature in the arc heater of the NASA Ames IHF arcjet facility (60 MW). An external cavity diode laser was used to generate light at 777.2 nm and laser absorption used to monitor the population of electronically excited oxygen atoms in an air plasma flow. Under the assumption of thermochemical equilibrium, time-resolved temperature measurements were obtained on four lines-of-sight, which enabled evaluation of the temperature uniformity in the plasma column for different arcjet operating conditions.

Martin, Marcel Nations↗

Qualification of a Multi-Channel Infrared Laser Absorption Spectrometer for Monitoring CO, HCl, HCN, HF, and CO2 Aboard Manned Spacecraft

Monitoring of specific combustion products can provide early-warning detection of accidental fires aboard manned spacecraft and also identify the source and severity of combustion events. Furthermore, quantitative in situ measurements are important for gauging levels of exposure to hazardous gases, particularly on long-duration missions where analysis of returned samples becomes impractical. Absorption spectroscopy using tunable laser sources in the 2 to 5 micrometer wavelength range enables accurate, unambiguous detection of CO, HCl, HCN, HF, and CO2, which are produced in varying amounts through the heating of electrical components and packaging materials commonly used aboard spacecraft. Here, we report on calibration and testing of a five-channel laser absorption spectrometer designed to accurately monitor ambient gas-phase concentrations of these five compounds, with low-level detection limits based on the Spacecraft Maximum Allowable Concentrations. The instrument employs a two-pass absorption cell with a total optical pathlength of 50 cm and a dedicated infrared semiconductor laser source for each target gas. We present results from testing the five-channel sensor in the presence of trace concentrations of the target compounds that were introduced using both gas sources and oxidative pyrolysis (non-flaming combustion) of solid material mixtures.

environmental monitoring↗

Near-IR diode laser absorption for measurement of tropospheric HO2

The possibility of using tunable lead salt diode lasers in the infrared for measurement of tropospheric HO2 has been frequently considered. Although the sensitivity of diode laser absorption has been improved through the use of high frequency detection techniques, nature has been unkind in that the HO2 absorption cross sections are weak. Even using the most optimistic assumptions about attainable path length and detectable absorbance, measurement of tropospheric HO2 by diode laser absorption in the mid-IR appears marginal. A possible alternative method for measuring HO2 is by absorption at near-infrared wavelengths. Several absorption bands of HO2 occur in the wavelength region between 1.2 and 1.6 micron due to electronic transitions and overtones of the fundamental vibrational modes. InGaAsP diode lasers operate in this wavelength region and can be used for high resolution spectroscopy in a manner analogous to the lead salt lasers. A diode laser system in the near-IR offers some advantages.

Stanton, Alan C.↗

Examination of Mars2020 Shock-Layer Conditions via Infrared Laser Absorption Spectroscopy of CO2 and CO

Amid-infrared laser absorption diagnostic was deployed to study a simulated Mars2020 shock layer in the Electric Arc Shock Tube (EAST) facility at NASA’s Ames Research Center. Rapid RF-diplexing techniques enabled quantitative temperature and number density measurements of CO2 and CO with μs-resolution over an incident shock velocity range of 1.39 – 3.75 km/s. Two interband cascade lasers were utilized at 4.17 and 4.19 μm to resolve eight CO2 asymmetric stretch fundamental band (𝜈3) transitions from two different vibrational levels: 0000 (ground state) and 0110 (first excited bending mode). The probed rotational levels span across J” = 58 to J” = 140. Results are compared to DPLR simulations of the shock layer using kinetic mechanisms of Johnston et al. and Cruden et al. At shock velocities below 3.1 km/s, the agreement between the measurements and the Johnston mechanism is typically within 5% for temperature and within 10% for number density. At shock velocities above 3.1 km/s, the CO2 measurement becomes sensitive to a thin boundary layer and corrections of this effect are presented. On test cases with enough energy to dissociate CO2, a quantum cascade laser scanned the P(2, 20), P(0, 31), and P(3, 14) transitions of the CO fundamental band at 4.98 μm. CO formation rate is measured to be close to the Johnston kinetic mechanism at low velocities, and then trending towards the Cruden kinetic mechanism at high velocities. On a few low velocity test cases, rovibrational relaxation of the Martian atmosphere is probed with μs resolution.

Laser Absorption↗

Laser absorption spectrometer - Remote measurement of tropospheric ozone

The laser absorption spectrometer (LAS) is an airborne instrument able to perform remote measurement of trace atmospheric gases. The instrument uses a pair of carbon dioxide laser-heterodyne receiver systems that are directed downward from an airplane and determines gas concentration by the differential absorption method. Configured to measure tropospheric ozone, the LAS has been used in conjunction with another instrumented aircraft to test the accuracy of this method of measurement. A complete description of the instrument is presented, and the results of extensive flight testing are summarized.

Shumate, M. S.↗

Diode laser absorption sensors for gas-dynamic and combustion flows

Recent advances in room-temperature, near-IR and visible diode laser sources for tele-communication, high-speed computer networks, and optical data storage applications are enabling a new generation of gas-dynamic and combustion-flow sensors based on laser absorption spectroscopy. In addition to conventional species concentration and density measurements, spectroscopic techniques for temperature, velocity, pressure and mass flux have been demonstrated in laboratory, industrial and technical flows. Combined with fibreoptic distribution networks and ultrasensitive detection strategies, compact and portable sensors are now appearing for a variety of applications. In many cases, the superior spectroscopic quality of the new laser sources compared with earlier cryogenic, mid-IR devices is allowing increased sensitivity of trace species measurements, high-precision spectroscopy of major gas constituents, and stable, autonomous measurement systems. The purpose of this article is to review recent progress in this field and suggest likely directions for future research and development. The various laser-source technologies are briefly reviewed as they relate to sensor applications. Basic theory for laser absorption measurements of gas-dynamic properties is reviewed and special detection strategies for the weak near-IR and visible absorption spectra are described. Typical sensor configurations are described and compared for various application scenarios, ranging from laboratory research to automated field and airborne packages. Recent applications of gas-dynamic sensors for air flows and fluxes of trace atmospheric species are presented. Applications of gas-dynamic and combustion sensors to research and development of high-speed flows aeropropulsion engines, and combustion emissions monitoring are presented in detail, along with emerging flow control systems based on these new sensors. Finally, technology in nonlinear frequency conversion, UV laser materials, room-temperature mid-IR materials and broadly tunable multisection devices is reviewed to suggest new sensor possibilities.

Non-NASA Center↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗