Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Tunable diode laser absorption spectroscopy with corrected laser ramping nonlinearities

A tunable diode laser absorption spectroscopy device includes a tunable diode laser. A laser driver is configured to drive the diode laser and ramp it within a particular frequency range. An analyte gas container, a reference gas container, and a fringe generating device are configured to receive the laser therethrough. An optical detector is configured to detect the laser after it has passed through the analyte gas container and/or the reference gas container, and the in-line fringe generating device. An acquisition card is configured to sample an output of the optical detector. A spectral analyzer is configured to receive output data from the acquisition card, determine a spectrum of the output data, decouple the fringe spectrum from the measured spectrum, calibrate the spectrum based on an expected ideal spectrum of both the fringe and reference gas, and determine a composition of the analyte based on the calibrated spectrum.

42 ENGINEERING↗

Detection limits for laser absorption spectroscopy of Li in laser ablation plumes

A high-sensitivity laser absorption spectroscopy (LAS) method is demonstrated for rapid and non-contact analysis of Li in solids. Glass samples with Li concentrations ranging from 1-500 ppm by mass are ablated in 5 Torr air, and time-resolved Li atomic absorption is measured using a tunable laser near 671 nm. Significant improvements in analytical performance over prior laser-induced breakdown techniques are demonstrated. Here, a single-shot limit of detection (LOD) of 180 ppb is shown for fixed wavelength operation, improving to 6 ppb with averaging over 1000 ablation shots (100 s acquisition time). Isotope-resolved Li absorption spectra are measured with a 17 ppb LOD in 40 s. Methods for optimizing LOD based on noise/averaging properties of LAS experiments in LA plumes are discussed.

(020.3260) Isotope shifts↗

Laser absorptivity measurement device

A laser absorptivity measurement device uses a linearly polarized incident beam, an optical configuration comprising an internal polarizing beamsplitter that transmits the linearly polarized incident beam and a quarter-wave plate that converts linearly polarized incident beam into a circularly polarized incident beam that is reflected off a processing substrate. The quarter-wave plate and polarizing beamsplitter can then direct the reflected light back into an integrating volume, where the power of the reflected light can be measured by a photodetector. The laser absorptivity measurement device is capable of making real-time absorption efficiency measurements of a variety of laser-based processes, including laser welding and brazing, additive manufacturing, and laser marking.

Tung, Daniel↗

Laser absorption measurements of electron density in nanosecond-scale atmospheric pressure pulsed plasmas

We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electron excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as n e = 7 x 10 19 cm -3 , and decay to 1/e of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[ 5 S o ]-3p[ 5 P] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coaxial laser absorption and optical emission spectroscopy of high-pressure aluminum monoxide

This work advances laser absorption spectroscopy with measurements of aluminum monoxide (AlO) temperature and column density in extreme pressure ( P > 60 bar) and temperature ( T > 4000 K) environments. Measurements of the AlO A 2 Π i – X 2 Σ + transition are made using a microelectromechanical system, tunable vertical cavity surface emitting laser (MEMS-VCSEL). Simultaneous emission measurements of the AlO B 2 Σ + – X 2 Σ + transition are made along a line of sight that is coaxial with the laser absorption. Absorption temperature fits agree with emission spectra for a T = 3200 K, P = 9 bar case. In cases with T > 4000 K, P > 60 bar, absorption fits match the ambient temperature while emission fits over-estimate it, owing to high optical depths. These data juxtapose passive and active spectroscopic methods and demonstrate the versatility of AlO laser absorption in high-pressure and high-temperature environments where experimental data remain scarce, and engineering models will benefit from refined measurements.

Daniel, K. A.↗

Investigation on laser absorption and x-ray radiation in microstructured titanium targets heated by short-pulse relativistic laser pulses

The enhancement effect of a microstructured surface on laser absorption and characteristic K α emission has been investigated by measuring K-shell emission from titanium (Ti) targets irradiated with high-intensity ( ∼ 10 20 W cm − 2 ), subpicosecond (500 fs) laser pulses. The experimental results indicate a modest enhancement ( 1.6 × ) of K α emission from microstructured targets compared to flat foils, but with a similar intensity and profile of He α and Li-like satellites. Particle-in-cell (PIC) simulations are implemented to further understand the underlying physical processes in the laser interaction with both targets, interpreting the mechanisms responsible for the K α enhancement. The reasons for the lower-than-expected enhancement of K α emission are discussed. The rapid heating of the bulk plasma might result in the premature shutdown of K α emission before the thermalization of hot electrons or even the end of laser pulses, suggesting that the use of K α emission as a diagnostic of the hot-electron yield or relaxation could lead to a misinterpretation. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feed-forward spectral calibration methodology for line-scanned tunable laser absorption spectroscopy

A generalized feed-forward method for accurate tunable laser absorption spectroscopy includes generating a laser beam. The generated laser beam is directed down a reference path and a test/sample path. One or more parameters are extracted from the reference path. The one or more parameters, extracted from the reference path, are used as feed-forward, to adjust spectral analysis of the test/sample path to detect a composition and/or concentration of an analyte gas within the test/sample path. The extraction of the one or more parameters from the reference path and the spectral analysis of the test/sample path are performed substantially concurrently.

Green, William↗

Deep learning approaches for instantaneous laser absorptance prediction in additive manufacturing

Abstract The quantification of absorbed light is essential for understanding laser-material interactions and melt pool dynamics in order to minimize defects in additively manufactured metal components. The geometry of a vapor depression formed during laser melting is closely related to laser energy absorption. This relationship has been observed by the state-of-the-art in situ high-speed synchrotron X-ray visualization and integrating sphere radiometry. These two techniques create a temporally resolved dataset consisting of vapor depression images and corresponding laser absorptance. In this work, we propose two different approaches to predict instantaneous laser absorptance. The end-to-end approach uses deep convolutional neural networks to learn implicit features of X-ray images automatically and predict the laser energy absorptance. The two-stage approach uses a semantic segmentation model to engineer geometric features and predict absorptance using classical regression models. While having distinct advantages, both approaches achieved a consistently low mean absolute error of less than 3.3%.

Chemistry↗

Turbulence-induced bias in time-averaged laser absorption tomography of correlated concentration and temperature fields with a first-order correction

The influence of correlated scalar fluctuations on time-averaged laser absorption tomography measurements of temperature and species in a piloted turbulent premixed flame was examined using a coupled spectroscopic and fluid-dynamic analysis. To understand bias associated with turbulence, spatio-temporally resolved temperature and species mole fraction profiles predicted by large eddy simulations (LES) were used to synthetically generate time-resolved line-of-sight absorption measurements at short time scales (microsecond) to reflect the unsteady nature of a canonical jet burner across various transverse measurement planes. Inversion methods were employed on the time-averaged line-of-sight data to produce radially-resolved temperature and mole fraction profiles, analogous to those produced by laser absorption tomography performed on a time-averaged axisymmetric flowfield. It is shown that bias in the measurements compared to true time-averaged scalar fields is a function primarily of temperature dependence in absorptivity and non-zero correlation between temperature and species concentration scalars. Finally, a first-order correction to tomography measurements is proposed to account for the bias based on estimated correlations and the known spectroscopic parameters of the probed absorption transitions.

42 ENGINEERING↗

Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration

This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. Here, this fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ~3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ~120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ~2 × 10 13 cm –3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation on laser absorption and x-ray radiation in microstructured titanium targets heated by short-pulse relativistic laser pulses

The enhancement effect of a microstructured surface on laser absorption and characteristic Kα emission has been investigated by measuring K-shell emission from titanium (Ti) targets irradiated with high-intensity (~10 20 W cm -2 ), subpicosecond (500 fs) laser pulses. The experimental results indicate a modest enhancement (1.6×) of Kα emission from microstructured targets compared to flat foils, but with a similar intensity and profile of Heα and Li-like satellites. Particle-in-cell (PIC) simulations are implemented to further understand the underlying physical processes in the laser interaction with both targets, interpreting the mechanisms responsible for the Kα enhancement. The reasons for the lower-than-expected enhancement of Kα emission are discussed. The rapid heating of the bulk plasma might result in the premature shutdown of Kα emission before the thermalization of hot electrons or even the end of laser pulses, suggesting that the use of Kα emission as a diagnostic of the hot-electron yield or relaxation could lead to a misinterpretation.

36 MATERIALS SCIENCE↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Tunable Infrared Laser Absorption Spectroscopy of Aluminum Monoxide $A^2\Pi_i $–$X^2\Sigma^+$.

We report the details of an infrared, laser absorption diagnostic capable of quantifying aluminum monoxide temperature and column density at 100 kHz repetition rate. This novel technique employs a near infrared MEMS-VCSEL to measure rotationally resolved optical absorption spectra of aluminum monoxide $A^2\Pi_i$ - $X^2\Sigma^+$ from approximately 7400 –7900 cm -1 . Temperatures and column densities are extracted from model regressions to provide temporally resolved thermochemical information on aluminum oxidation reactions. The measurement capability is demonstrated by performing 100 kHz measurement in the plume of an exploding bridgewire with measured temperatures of 3450–3100 K and column densities of 1– 11 x 10 16 cm -2 . To the authors knowledge, this is the first use of the AlO $A^2\Pi_i$ - $X^2\Sigma^+$ transition to characterize aluminum combustion environments. Details regarding signal extraction and calibration of MEMS-VCSEL spectra are also included. Although unsuccessful, efforts to extract kinetic temperature and column density from simultaneously measured, atomic aluminum 2 P 3/2,1/2 - 2 S 1/2 transitions at 7618 cm -1 and 7602 cm -1 are also described.

47 OTHER INSTRUMENTATION↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Temperature estimation in a spatially inhomogeneous flame by diode laser absorption spectroscopy

A two-temperature (2T) model is proposed for estimating the temperature of a spatially inhomogeneous hot zone using single-beam diode laser absorption spectrometry. The proposed algorithm is based on fitting experimental absorption spectra by a linear combination of two database-simulated single-temperature spectra with different temperatures. The model efficiency is experimentally demonstrated when determining the temperature in different flame zones of a Wolfgard – Parker slot burner. The proposed 2T algorithm is used to find the maximum and minimum temperatures in different flame sections, which are compared with local temperatures in the same flame zones measured by the method of coherent anti-Stokes Raman scattering (CARS). It is shown that the maximum temperatures determined by the proposed 2T algorithm are in good agreement with CARS data in flame zones where high-temperature regions prevail. A good agreement between the minimum temperatures obtained by these two methods is also observed for predominantly cold zones. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗