Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Terahertz Spectroscopy of Gas Mixtures with Dual Quantum Cascade Laser Frequency Combs

Terahertz laser frequency combs based on quantum cascade lasers provide coherent, broadband, electrically pumped, THz radiation sources for use in future spectroscopic applications. In this work, we explore the feasibility of such lasers in a dual-comb spectroscopy configuration for the detection of multiple molecular samples in the gas phase. The lasers span approximately 180 GHz of optical bandwidth, centered at 3.4 THz, with submilliwatt total optical power. One of the main advantages of dual-comb spectroscopy is its high speed, which opens up the possibility for direct observations of chemical reaction dynamics in the terahertz spectral region. As a proof-of-concept, we recorded continuously evolving spectra from gas mixtures with 1 ms temporal resolution.

42 ENGINEERING↗

Experimental and numerical evaluation of laser shinethrough in polystyrene at 3 ω and 4 ω laser frequencies

In laser-direct-drive inertial confinement fusion (ICF), laser shinethrough is the process associated with laser propagation through the target plastic ablator, polystyrene is often used in ICF experiments, and leads to energy deposition in the target until the critical density is established at the ablator front surface. This process causes material modifications that may change the shock propagation and lead to density and pressure perturbations at the interface between the polystyrene and cryogenic deuterium-tritium (DT) layer. This work reports on experimental observations and numerical investigations of laser shinethrough at the third and the fourth harmonic of ICF class laser systems (1 ω corresponds to a wavelength of ∼1.06 μm ). The experiments evidence that, at 4 ω , the laser is absorbed over a distance of about a few microns and laser shinethrough is completely eliminated in contrast with the behavior at 3 ω . These experimental observations are reproduced by numerical simulations. The laser fluence required to reach the critical density at the ablator front surface is also found to be more than one order of magnitude higher at the third harmonic. Finally, modeling suggests that the back surface of the ablator exhibits ion temperatures greater than the melting temperature of cryogenic DT and electron pressure larger than the bulk and shear moduli of cryogenic DT for the case of using a 3 ω laser.

Pineau, A. [Univ. of Rochester, NY (United States)↗

Electron energy gain due to a laser frequency modulation experienced by electron during betatron motion

Direct laser acceleration of electrons is an important energy deposition mechanism for laser-irradiated plasmas that is particularly effective at relativistic laser intensities in the presence of quasi-static laser-driven plasma electric and magnetic fields. These radial electric and azimuthal magnetic fields provide transverse electron confinement by inducing betatron oscillations of forward-moving electrons undergoing laser acceleration. Electrons are said to experience a betatron resonance when the frequency of betatron oscillations matches the average frequency of the laser field oscillations at the electron position. In this paper, we show that the modulation of the laser frequency as seen by an electron performing betatron oscillations can be another important mechanism for net energy gain that is qualitatively different from the betatron resonance. Specifically, we show that the frequency modulation experienced by the electron can lead to net energy gain in the regime where the laser field performs three oscillations per betatron oscillation. There is no net energy gain in this regime without the modulation because the energy gain is fully compensated by the energy loss. The modulation slows down the laser oscillation near transverse stopping points, increasing the time interval during which the electron gains energy and making it possible to achieve net energy gain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-resonant four-photon collinear laser frequency multiplication in plasma

Resonant four-photon scattering could nearly double frequencies of intense laser pulses in plasma. However, transverse slippage between pulses presents a technological challenge, while collinear four-photon scattering is forbidden for classical light dispersion in plasma. Nonlinear renormalization of intense laser pulses can enable collinear four-photon resonance. However, such a very intensity-sensitive resonance is difficult to maintain for evolving pulses. Remarkably, there is a lower-dimensionality submanifold of the resonant four-photon manifold where the evolving pulses stay in resonance. Furthermore this could enable an all-optical frequency doubling of mildly relativistic-intense laser pulses in collinear geometry, advantageously free of the transverse slippage challenges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Laser Frequency Transverse Modulation Might Compensate for the Spectral Broadening Due to Large Electron Energy Spread in Thomson Sources

Compact laser plasma accelerators generate high-energy electron beams with increasing quality. When used in inverse Compton backscattering, however, the relatively large electron energy spread jeopardizes potential applications requiring small bandwidths. We present here a novel interaction scheme that allows us to compensate for the negative effects of the electron energy spread on the spectrum, by introducing a transverse spatial frequency modulation in the laser pulse. Such a laser chirp, together with a properly dispersed electron beam, can substantially reduce the broadening of the Compton bandwidth due to the electron energy spread. We show theoretical analysis and numerical simulations for hard X-ray Thomson sources based on laser plasma accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of blue and infrared laser melting frequency on oxide morphology in 304L

Continuous Wave Laser Beam (LB) melting offers control over the localised heating and cooling of melt pools for welding, brazing, additive manufacturing and solidification. Research into laserliquid metal interactions has primarily focused on the heat and mass transport under large thermal gradients imposed by the localised melting conditions. Recent commercial availability of blue (450 nm) wavelength lasers has enabled the printing of material with poor IR (1064) nm attenuation like Cu. However, little research has been conducted into varying input laser frequency and scan rate at fixed absorption to understand the effects of laser light on surface oxide formation and the underlying liquid metal thermodynamic response. Here, this article conducts laser melting of 304L under Blue (450 nm) and Infrared (IR, 1064 nm) laser frequencies and examines their impact on laser oxide thickness, chemistry and coloration. We find that laser frequencies induce changes in the oxide layer thickness and chemistry that cannot be explained using conventional thermal absorption shifts and fluid dynamics. We suggest that light coupling may have thermodynamic implications for the chemical potential of the liquid metal, which may drive the observed phase behaviour. Identifying mechanisms for the tuning of the chemical potential via laser frequency control could enable the ability to control solidification microstructure and atomic ordering in laser welding and additive manufacturing processes.

304L↗

Compensation of residual amplitude modulation fluctuations in an optoelectronic system for laser radiation frequency stabilisation

Fluctuations of residual amplitude modulation in a scheme of laser frequency stabilisation by a Fabry – Perot cavity reduce the frequency stability of the laser systems intended for interrogating clock transitions of atoms and ions. The dependences of the residual amplitude modulation on a temperature of the waveguide-based electro-optical modulator used for modulating the radiation phase and on polarisation of the radiation are measured. The parameters are found, at which the influence of the residual amplitude modulation on the frequency stability is minimal. A system for active compensation is created, which reduces the contribution of fluctuations of residual amplitude modulation to the instability down to 2.1 × 10{sup −16}, which makes it possible to reach the thermal noise limit of a silicon cryogenic cavity. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗

Frequency-Selectable Laser Source (FLS) Calibrator for CMB Bandpass Characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from our detector bandpass calibration. Uncertainties in bandpass can severely limit our measurements by limiting foreground removal and spectral fitting, which is particularly important for high-$\ell$ observations like cluster science using the Sunyaev-Zeldovich (SZ) effect. Currently, CMB experiments typically use a Fourier Transform Spectrometer (FTS) to measure the detector bandpasses. However, the resolution of the FTS is dependent on the length of the interferometer arms, leading to a need for increasingly large FTS instruments as CMB experiments require tighter constraints on detector bandpasses. Additionally, systematic effects like shifts in bandpass shape from uneven illumination from the FTS further limit the calibration uncertainties. As a complement to the FTS, we have developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency housed in a calibrator that allows for varying degrees of laser power attenuation. We present several tests used to characterize the first prototype design of the FLS calibrator, as well as the improvements to the calibrator design currently underway.

Saunders, Lauren [Fermilab]↗

Experimental studies of 1.5 – 1.6 μm high-power single-frequency semiconductor lasers

High-power semiconductor laser systems based on 1.5 – 1.6 μm single-frequency distributed feedback (DFB) lasers with a sidewall Bragg diffraction grating are developed and their current – voltage, light – current, and spectral characteristics are experimentally studied. The characteristics of conventional lasers with a Fabry – Perot cavity and DFB lasers fabricated from one and the same heterostructure are compared. At a pump current not exceeding 700 mA, a conventional laser with a cavity length of 1.6 mm and a mesa-stripe width of 3 μm emits a power no lower than 200 mW versus 150 mW of the DFB laser; both lasers are mounted in a housing 11 mm in diameter. The DFB laser mounted in a butterfly housing emits a power no lower than 100 mW at the exit of the single-mode cable at a pump current not exceeding 500 mA, which, at a 60 % coupling efficiency, corresponds to a power no lower than 165 mW; the side-mode suppression ratio in this case is no lower than 53 dB. It is shown that the wavelength deviation with changing pump current and temperature is almost an order of magnitude lower for the DFB laser than for the conventional laser. (paper)

36 MATERIALS SCIENCE↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Frequency-Selectable Laser Source for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M. [Fermilab]↗

Frequency-Selectable Laser Source (FLS) for Cosmic Microwave Background Experiments

Cosmic Microwave Background (CMB) experiments measure remnant radiation from the early universe and use that data to determine fundamental properties of the universe. We can constrain key parameters, such as \textit{r}, the cosmic tensor-to-scalar ratio, and $N_\text{eff}$, the effective number of relativistic species, by analyzing the CMB power spectra. Improving our measurements of the CMB requires improving our instrument systematics, one of the most important of which is detector bandpass. Current experiments use a Fourier Transform Spectrometer (FTS) to measure bandpass. However, the FTS is systematics limited, and cannot achieve the accuracy needed to make improved CMB measurements. For this reason, we are developing a new instrument, the Frequency-Selectable Laser Source (FLS) to decrease the uncertainty in bandpass by an order of magnitude. In this paper, we describe work completed to support the version 2 upgrade to the FLS. Using ray-tracing software, we modeled the FLS optics to set physical tolerances for the new design. We also discuss the laser calibration, and future work to be completed in further development of the FLS upgrade.

Rosen-Turits, Gabriel M.↗