Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

ON THE COMPLEMENTARITY OF PULSAR TIMING AND SPACE LASER INTERFEROMETRY FOR THE INDIVIDUAL DETECTION OF SUPERMASSIVE BLACK HOLE BINARIES

Gravitational waves coming from supermassive black hole binaries (SMBHBs) are targeted by both the Pulsar Timing Array (PTA) and Space Laser Interferometry (SLI). The possibility of a single SMBHB being tracked first by PTA, through inspiral, and later by SLI, up to merger and ring-down, has been previously suggested. Although the bounding parameters are drawn by the current PTA or the upcoming Square Kilometer Array (SKA), and by the New Gravitational Observatory (NGO), derived from the Laser Interferometer Space Antenna (LISA), this paper also addresses sequential detection beyond specific project constraints. We consider PTA-SKA, which is sensitive from 10{sup -9} to p Multiplication-Sign 10{sup -7} Hz (p = 4, 8), and SLI, which operates from s Multiplication-Sign 10{sup -5} up to 1 Hz (s = 1, 3). An SMBHB in the range of 2 Multiplication-Sign 10{sup 8}-2 Multiplication-Sign 10{sup 9} M {sub Sun} (the masses are normalized to a (1 + z) factor, the redshift lying between z = 0.2 and z = 1.5) moves from the PTA-SKA to the SLI band over a period ranging from two months to fifty years. By combining three supermassive black hole (SMBH)-host relations with three accretion prescriptions, nine astrophysical scenarios are formed. They are then related to three levels of pulsar timing residuals (50, 5, 1 ns), generating 27 cases. For residuals of 1 ns, sequential detection probability will never be better than 4.7 Multiplication-Sign 10{sup -4} yr{sup -2} or 3.3 Multiplication-Sign 10{sup -6} yr{sup -2} (per year to merger and per year of survey), according to the best and worst astrophysical scenarios, respectively; put differently this means one sequential detection every 46 or 550 years for an equivalent maximum time to merger and duration of the survey. The chances of sequential detection are further reduced by increasing values of the s parameter (they vanish for s = 10) and of the SLI noise, and by decreasing values of the remnant spin. The spread in the predictions diminishes when timing precision is improved or the SLI low-frequency cutoff is lowered. So while transit times and the SLI signal-to-noise ratio (S/N) may be adequate, the likelihood of sequential detection is severely hampered by the current estimates on the number-just a handful-of individual inspirals observable by PTA-SKA, and to a lesser extent by the wide gap between the pulsar timing and space interferometry bands, and by the severe requirements on pulsar timing residuals. Optimization of future operational scenarios for SKA and SLI is briefly dealt with, since a detection of even a single event would be of paramount importance for the understanding of SMBHBs and of the astrophysical processes connected to their formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Invited Article: Expanded and improved traceability of vibration measurements by laser interferometry

Traceability to the International System of Units has been established for vibration and shock measurements as specified in international document standards, recommendations, and regulations to ensure product quality, health, and safety. New and upgraded laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods in the ISO 16063 series of international document standards. In ISO 16063-11:1999, three interferometric methods are specified for the primary calibration of vibration transducers (reference standard accelerometers) in a frequency range from 1 Hz to 10 kHz. In order to specify the same (modified) methods for the calibration of laser vibrometers (ISO 16063-41:2011), their applicability in an expanded frequency range was investigated. Steady-state sinusoidal vibrations were generated by piezoelectric actuators at specific frequencies up to 347 kHz (acceleration amplitudes up to 376 km/s{sup 2}). The displacement amplitude, adjusted by the special interferometric method of coincidence to 158.2 nm (quarter the wavelength of the He-Ne laser light), was measured by the standardized interferometric methods of fringe counting and sine-approximation. The deviations between the measurement results of the three interferometric methods applied simultaneously were smaller than 1 %. The limits of measurement uncertainty specified in ISO 16063-11 between 1 Hz to 10 kHz were kept up to frequencies, which are orders of magnitude greater; the uncertainty limit 0.5 % specified at the reference frequency 160 Hz was not exceeded at 160 kHz. The reported results were considered during the development of ISO 16063-41 by specifying the instrumentation and procedures for performing calibrations of rectilinear laser vibrometers in the frequency range typically between 0.4 Hz and 50 kHz—the interferometric methods may be applied within expanded frequency ranges using refined techniques and procedures. It is concluded that calibration frequencies up to 0.5 MHz are attainable in compliance with the first international document standard for the calibration of laser vibrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗

Investigation of Radius of Curvature Measurements using Laser Interferometry [Slides]

Goals for this work are to: develop an application using a ZYGO Verifire for calibration of artifacts where the measurand is defined as a Radius of Curvature (ROC), validate the measurements through an uncertainty analysis, and determine if the calibration method is a viable alternative/option for calibration outside of current standard methodologies.

42 ENGINEERING↗

Quantum Gravity and Laser Interferometry: Towards Observable Predictions

Understanding quantum gravity remains one of the deepest challenges in modern physics, as direct experimental access to Planck-scale effects is beyond current technological reach. However, recent theoretical advances indicate that quantum fluctuations of spacetime may produce measurable effects in precision experiments, particularly near causal horizons. This opens new avenues for testing quantum gravity phenomena through high-precision measurement techniques. This dissertation develops multiple theoretical models to characterize these effects and examines their potential observational signatures in future gravitational wave interferometers. We begin by investigating the role of quantum fluctuations in near-horizon geometries through the lens of the AdS/CFT correspondence, which provides a powerful framework for understanding the interplay between quantum field theory and general relativity via holographic principles. By modeling stochastic energy-momentum sources in Rindler-AdS spacetime, we demonstrate that vacuum fluctuations transform the Einstein equations into a Langevin-type stochastic differential equation, leading to potentially observable fluctuations in photon traversal times. Extending this approach to Minkowski spacetime, we establish a correspondence between gravitational shockwaves and fluid dynamics, showing that near-horizon perturbations satisfy an equation analogous to that governing incompressible fluids, thereby reinforcing the membrane paradigm and hydrodynamic analogies in the context of the fluid/gravity duality. Furthermore, we construct the covariant phase space of a spherically symmetric causal diamond in Minkowski spacetime, identifying two fundamental charges that govern its evolution. These results provide a foundation for quantizing causal horizons and understanding their microscopic degrees of freedom. Building upon these theoretical developments, we further examine a related stochastic phenomenon: the gravitational wave memory background arising from the cumulative memory steps produced by supermassive black hole mergers. After reviewing the standard stochastic gravitational wave background, gravitational memory effects, and BMS symmetries, we model the stochastic memory background using a Brownian motion framework. We show that while the cumulative memory background initially appears above the sensitivity curve of space-based interferometers like LISA, the realistic subtraction of individually resolvable merger events substantially suppresses the residual signal, making its detection more challenging. This highlights the critical importance of source subtraction when evaluating the detectability of gravitational memory effects. By bridging fundamental theory with experimental prospects, this dissertation contributes to the ongoing effort to uncover the quantum nature of spacetime through precision measurement techniques. Whether through detecting quantum spacetime fluctuations, gravitational memory backgrounds, or probing the symmetries of causal horizons, the pursuit of observable quantum gravity phenomena continues to expand the frontiers of both theory and experiment.

Zhang, Yiwen [Caltech] (ORCID:0000000323559416)↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Parallel multiplex laser feedback interferometry

We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel electron density reconstruction method for asymmetrical toroidal plasmas

A novel reconstruction method is developed for acquiring the electron density profile from multi-channel interferometric measurements of strongly asymmetrical toroidal plasmas. It is based on a regularization technique, and a generalized cross-validation function is used to optimize the regularization parameter with the aid of singular value decomposition. The feasibility of method could be testified by simulated measurements based on a magnetic configuration of the flexible helical-axis heliotron device, Heliotron J, which has an asymmetrical poloidal cross section. And the successful reconstruction makes possible to construct a multi-channel Far-infrared laser interferometry on this device. The advantages of this method are demonstrated by comparison with a conventional method. The factors which may affect the accuracy of the results are investigated, and an error analysis is carried out. Based on the obtained results, the proposed method is highly promising for accurately reconstructing the electron density in the asymmetrical toroidal plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of the multiple spallation parameters and the internal structure of a particle cloud during shock-wave loading of a metal

The results of experiments on studying spallation and the ejection of particles from the surfaces of copper and lead samples are presented. A laser interferometry method is used to detect the particle cloud velocity and the multiple spallation parameters. Angular detectors are used to detect the depth profile of the particle cloud velocity dispersion and the structure of metal spallation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of non-contact measurement of the thermal expansion coefficients of materials based on laser feedback interferometry

The noncooperative and ultrahigh sensitive length measurement approach is of great significance to the study of a high-precision thermal expansion coefficient (TEC) determination of materials at a wide temperature range. The novel approach is presented in this paper based on the Nd:YAG microchip laser feedback interferometry with 1064 nm wavelength, the beam frequency of which is shifted by a pair of acousto-optic modulators and then the heterodyne phase measurement technique is used. The sample is placed in a muffle furnace with two coaxial holes opened on the opposite furnace walls. The measurement beams are perpendicular and coaxial on each surface of the sample, the configuration which can not only achieve the length measurement of sample but also eliminate the influence of the distortion of the sample supporter. The reference beams inject on the reference mirrors which are put as possible as near the holes, respectively, to eliminate the air disturbances and the influence of thermal lens effect out of the furnace chamber. For validation, the thermal expansion coefficients of aluminum and steel 45 samples are measured from room temperature to 748 K, which proved measurement repeatability of TECs is better than 0.6 × 10{sup −6}(K{sup −1}) at the range of 298 K–598 K and the high-sensitive non-contact measurement of the low reflectivity surface induced by the oxidization of the samples at the range of 598 K–748 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proper time observables of general gravitational perturbations in laser interferometry-based gravitational wave detectors

We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇⁢𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.

Dark matter detectors↗

Study of ablation and implosion stages in wire arrays using coupled ultraviolet and X-ray probing diagnostics

Star and cylindrical wire arrays were studied using laser probing and X-ray radiography at the 1-MA Zebra pulse power generator at the University of Nevada, Reno. The Leopard laser provided backlighting, producing a laser plasma from a Si target which emitted an X-ray probing pulse at the wavelength of 6.65 Å. A spherically bent quartz crystal imaged the backlit wires onto X-ray film. Laser probing diagnostics at the wavelength of 266 nm included a 3-channel polarimeter for Faraday rotation diagnostic and two-frame laser interferometry with two shearing interferometers to study the evolution of the plasma electron density at the ablation and implosion stages. Dynamics of the plasma density profile in Al wire arrays at the ablation stage were directly studied with interferometry, and expansion of wire cores was measured with X-ray radiography. The magnetic field in the imploding plasma was measured with the Faraday rotation diagnostic, and current was reconstructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coriolis force compensation and laser beam delivery for 100-m baseline atom interferometry

The Coriolis force is a significant source of systematic phase errors and dephasing in atom interferometry and is often compensated by counter-rotating the interferometry laser beam against Earth's rotation. We present a novel method for performing Coriolis force compensation for long-baseline atom interferometry, which mitigates atom-beam misalignment due to beam rotation, an effect which is magnified by the long lever arm of the baseline length. The method involves adjustment of the angle of the interferometer beam prior to a magnifying telescope, enabling the beam to pivot around a tunable position along the interferometer baseline. By tuning the initial atom kinematics and adjusting the angle with which the interferometer beam pivots about this point, we can ensure that the atoms align with the center of the beam during the atom optics laser pulses. This approach will be used in the MAGIS-100 atom interferometer and could also be applied to other long-baseline atom interferometers. An additional challenge associated with long baseline interferometry is that since long-baseline atom interferometers are often located outside of typical laboratory environments, facilities constraints may require lasers to be housed in a climate-controlled room a significant distance away from the main experiment. Nonlinear effects in optical fibers restrict the use of fiber-based transport of the high-power interferometry beam from the laser room to the experiment. We present the design of and prototype data from a laser transport system for MAGIS-100 that maintains robustness against alignment drifts despite the absence of a long fiber.

Glick, Jonah↗

Laser scattering by submicron droplets formed during the electrical explosion of thin metal wires

Abstract This paper presents the results of studying dispersed media formation during the electrical explosion of thin metal wires in vacuum by using low-current generators (~1–10 kA). Particular attention is paid to the analysis of the composition and structure of the corresponding explosion products as well as to the problem of their visualization using simultaneous laser interferometry and shadow imaging at two wavelengths (1.064 µ m and 0.532 µ m). Our findings indicate the important role in the visualization of the explosion products that belongs to multiple scattering by submicron droplets of dense condensed matter, which are mixed with metal vapor. The hypothesis on the existence of submicron droplets in the products of exploding metal wires correlates with the results obtained by soft x-ray radiography combined with a laser probing technique. Taking into account the multiple scattering by submicron droplets, it is possible to significantly clarify the parameters of the explosion products visualized via laser probing techniques as well as to gain a deeper insight into the physics behind the electrical wire explosion.

Physics↗