Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Frequency-Tunable Pre-stabilized lasers for LISA via Stabilized Lasers for LISA via Sideband Locking

This viewgraph presentation discusses a major potential source of noise for the Laser Interferometer Space Antenna (LISA) that is the laser frequency noise and the proposed mechanism to suppress the unstabilized frequency fluctuations. These fluctuations must be suppresed by about 12 orders of magnitude to achieve a stability that is sufficient for the detection of gravitational waves. This presentation reviews present a modification to the traditional cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This presentation also discusses measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements and a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilization stage.

Livas, Jeffrey↗

Laser stabilization at the millihertz level

The main task of this paper is to identify a number of physical problems that must be successfully addressed to achieve stabilized laser linewidths well below 1 Hz. After presentation of the basic stability characteristics of available laser sources, it is shown that if any of these lasers were optimally locked to a high-finesse Fabry-Perot cavity it would be theoretically possible to obtain a laser linewidth in the millihertz domain. Problems of optical feedback, modulation waveform errors, mechanical support and isolation of the reference cavity, thermal stabilization of the environment, etc. are considered, and interim solutions are discussed. Experimentally, locking accuracy to successive cavity orders of less than 0.00002 linewidths (+ or - 1.5 Hz) was achieved; mirror birefringence pulled the lock point approximately 10-fold more. Relative phase coherence between two independent lasers locked onto adjacent cavity orders was preserved for 8 sec, corresponding to a linewidth of each optical source of about 50 mHz.

Salomon, CH.↗

Scientific applications of frequency-stabilized laser technology in space

A synoptic investigation of the uses of frequency-stabilized lasers for scientific applications in space is presented. It begins by summarizing properties of lasers, characterizing their frequency stability, and describing limitations and techniques to achieve certain levels of frequency stability. Limits to precision set by laser frequency stability for various kinds of measurements are investigated and compared with other sources of error. These other sources include photon-counting statistics, scattered laser light, fluctuations in laser power, and intensity distribution across the beam, propagation effects, mechanical and thermal noise, and radiation pressure. Methods are explored to improve the sensitivity of laser-based interferometric and range-rate measurements. Several specific types of science experiments that rely on highly precise measurements made with lasers are analyzed, and anticipated errors and overall performance are discussed. Qualitative descriptions are given of a number of other possible science applications involving frequency-stabilized lasers and related laser technology in space. These applications will warrant more careful analysis as technology develops.

Schumaker, Bonny L.↗

A 15 Meter Laser-Stabilized Imaging Interferometer

The Laser-Stabilized Imaging Interferometer (LASII) concept is being developed as a candidate for the next generation of optical resolution beyond Hubble Space Telescope (HST). The essential ingredients are: a rigid and stable structure to minimize mechanical and thermal distortion, active control of the optical geometry by a laser metrology system, a self-deploying structure fitting into a single launch vehicle, and ultraviolet operation. We have modified earlier design concepts to fit the scale of an intermediate sized NASA mission.

Imaging↗

Absolute photometric calibration of detectors to 0.3 mmag using amplitude-stabilized lasers and a helium-cooled absolute radiometer

Laser sources whose intensity is determined with a cryogenic electrical substitution radiometer are described. Detectors are then calibrated against this known flux, with an overall error of 0.028 percent (0.3 mmag). Ongoing research has produced laser intensity stabilizers with flicker and drift of less than 0.01 percent. Recently, the useful wavelength limit of these stabilizers have been extended to 1.65 microns by using a new modular technology and InGaAs detector systems. Data from Si photodiode calibration using the method of Zalewski and Geist are compared against an absolute cavity radiometer calibration as an internal check on the calibration system.

Miller, Peter J.↗

Development Towards a Space Qualified Laser Stabilization System in Support of Space-Based Optical Interferometers

We report on the development, functional performance and space-qualification status of a laser stabilization system supporting a space-based metrology source used to measure changes in optical path lengths in space-based stellar interferometers. The Space Interferometry Mission (SIM) and Deep Space 3 (DS-3) are two missions currently funded by the National Aeronautics and Space Administration (NASA) that are space-based optical interferometers. In order to properly recombine the starlight received at each telescope of the interferometer it is necessary to perform high resolution laser metrology to stabilize the interferometer. A potentially significant error source in performing high resolution metrology length measurements is the potential for fluctuations in the laser gauge itself. If the laser frequency or wavelength is changing over time it will be misinterpreted as a length change in one of the legs of the interferometer. An analysis of the frequency stability requirement for SIM resulted in a fractional frequency stability requirement of square root (S(sub y)(f)) = <2 x 10(exp -12)/square root(Hz) at Fourier frequencies between 10 Hz and 1000 Hz. The DS-3 mission stability requirement is further increased to square root (S(sub y)(f)) = <5 x 10(exp -14)/Square root(Hz) at Fourier frequencies between 0.2 Hz and 10 kHz with a goal of extending the low frequency range to 0.05 Hz. The free running performance of the Lightwave Electronics NPRO lasers, which are the baseline laser for both SIM and DS-3 vary in stability and we have measured them to perform as follows (9 x l0(exp -11)/ f(Hz))(Hz)/square root(Hz)) = <( square root (S(sub y)(f)) = <(1.3 x l0(exp -8)/ f(Hz))/Square root(Hz). In order to improve the frequency stability of the laser we stabilize the laser to a high finesse optical cavity by locking the optical frequency of the laser to one of the transmission modes of the cavity. At JPL we have built a prototype space-qualifiable system meeting the stability requirements of SIM, which has been delivered to one of the SIM testbeds. We have also started on the development of a system to meet the stability needs of DS-3.

Seidel, David J.↗

Diode laser stabilization

Center-frequency drift in diode lasers can be reduced by stabilizing the laser to an optical cavity with a low bandwidth feedback loop that acts on the injection current. Resonant optical feedback from a confocal or ring cavity can reduce high frequency noise, yielding linewidths in the 10 kHz range. With either an optical or an electronic lock to a cavity, the laser's wavelength is restricted to those regions that can be reached by temperature and current tuning of the solitary diode; this can be extended to full coverage by means of an extended cavity with a frequency-selective component, such as a diffraction grating.

Fox, R. W.↗

Laser Frequency Stabilization

Laser ranging and interferometry are essential technologies allowing for many astounding new spacebased missions such as the Laser Interferometer Space Antenna (LISA) to measure gravitational radiation emitted from distant super massive black hole mergers or distributed aperture telescopes with unprecedented angular resolution in the NIR or visible regime. The requirements on laser frequency noise depend on the residual motion and the distances between the spacecraft forming the interferometer. The intrinsic frequency stability of commercial lasers is several orders of magnitude above these requirements. Therefore, it is necessary for lasers to be stabilized to an ultrastable frequency reference so that they can be used to sense and control distances between spacecraft. Various optical frequency references and frequency stabilization schemes are considered and investigated for the applicability and usefulness for space-based interferometry missions.

Donelan, Darsa↗

Absolute calibration of an ultraviolet spectrometer using a stabilized laser and a cryogenic cavity radiometer

We carry out the calibration of an ultraviolet spectrometer by using a cryogenic electrical-substitution radiometer and intensity-stabilized laser sources. A comparison of the error budgets for the laser-based calibration described here and for a calibration using a type-FEL tungsten spectral-irradiance standard indicates that this technique could provide an improvement of a factor of about three in the uncertainty of the spectrometer calibration, resulting in an absolute accuracy (standard deviation of three) of about 1 percent at 257 nm. The technique described here might significantly improve the accuracy of calibrations on NASA ozone-monitoring and solar ultraviolet-monitoring spectrophotometers when used to complement present procedures that employ lamps and the SURF II synchrotron ultraviolet radiation facility at the National Institute of Standards and Technology.

Jauniskis, L.↗

Spectrophone stabilized laser with line center offset frequency control

Continuous offset tuning of a frequency stabilized CW gas laser is achieved by using a spectrophone filled with the same gas as the laser for sensing a dither modulation, detecting a first or second derivative of the spectrophone output with a lock-in amplifier, the detected output of which is integrated, and applying the integrator output as a correction signal through a circuit which adds to the dither signal from an oscillator a dc offset that is adjusted with a potentiometer to a frequency offset from the absorption line center of the gas, but within the spectral linewidth of the gas. Tuning about that offset frequency is achieved by adding a dc value to the detected output of the dither modulation before integration using a potentiometer.

Kavaya, M. J.↗

Frequency-tunable Pre-stabilized Lasers for LISA via Sideband-locking

Laser frequency noise mitigation is one of the most challenging aspects of the LISA interferometric measurement system. The unstabilized frequency fluctuations must be suppressed by roughly twelve orders of magnitude in order to achieve stability sufficient for gravitational wave detection. This enormous suppression will be achieved through a combination of stabilization and common-mode rejection. The stabilization component will itself be achieved in two stages: pre-stabilization to a local optical cavity followed by arm-locking to some combination of the inter-spacecraft distances. In order for these two stabilization stages to work simultaneously, the lock-point of the pre-stabilization loop must be frequency tunable. The current baseline stabilization technique, locking to an optical cavity, does not provide tunability between cavity resonances, which are typically spaced by 100s of MHz. Here we present a modification to the traditional Pound-Drever-Hall cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This technique requires no modifications to the optical cavity itself, thus preserving the stability of the frequency reference. We present measurements of the system performance and demonstrate that we can meet implement the first two stages of stabilization.

Livas, Jeffrey C.↗

Frequency-Tuneable Pre-Stabilized Lasers for LISA via Sideband Locking

Laser frequency noise mitigation is one of the most challenging aspects of the LISA interferometric measurement system. The unstabilized frequency fluctuations must be suppressed by roughly twelve orders of magnitude in order to achieve a stability sufficient for gravitational wave detection. This enormous suppression will be achieved through a combination of stabilization and common-mode rejection. The stabilization component will itself be achieved in two stages: pre-stabilization to a local optical cavity followed by arm-locking to some combination of the inter-spacecraft distances. In order for these two stabilization stages to work simultaneously, the lock-point of the pre-stabilization loop must be frequency tunable. The current baseline stabilization technique, locking to an optical cavity, does not provide tunability between cavity resonance, which are typically spaced by 100s of MHz. Here we present a modification to the traditional Pound-Drever-Hall cavity locking technique that allows the laser to be locked to a cavity resonance with an adjustable frequency offset. This technique requires no modifications to the optical cavity itself, thus preserving the stability of the frequency reference. We present measurements of the system stability, demonstrating that the pre-stabilization level satisfies LISA requirements. We also present a demonstration of a phase-lock loop which utilizes the tunable sideband locking technique as a pre-stabilizations tage. The performance of the pre-stabilized phase-lock-loop indicates that the tunable sideband technique will meet the requirements as an actuator for arm-locking in LISA.

Thorpe, James Ira↗