Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser-based optical spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Non-intrusive measurement of magnetic field strengths in a low-pressure argon plasma using quantum beat spectroscopy

Abstract Accurate measurement of magnetic field strengths is critical in many plasma environments, ranging from astrophysical systems to fusion energy research. In this work, a non-perturbative laser-based optical diagnostic known as quantum beat spectroscopy is demonstrated to be good alternative for measuring the magnetic field strength in low-pressure laboratory plasmas. The technique is investigated using both ns and fs pulsed lasers in an argon plasma. Preliminary results for a helium plasma are also given. Zeeman-split J = 1 electron states with transitions from metastable states were identified and tested for neutral argon ( 2 P 1 / 2 o ) 4 p 2 [ 1 / 2 ] and neutral helium 1 s 3 p 1 P 1 o . Magnetic fields are measured with sub-Gauss precision at near single laser pulse acquisition rates.

Gilbert, Tyler J. (ORCID:0000000160400119)↗

Dual-Comb Spectroscopy to Tethered Balloon System (DCS to TBS) Field Campaign Report

There is a critical need for the ability to detect, quantify, and attribute sources and sinks of greenhouse gases (GHGs) with high temporal and spatial resolution. Current methods are typically based on continuously operating near-surface point sensors or intermittent aerial/satellite observations. Dual optical frequency comb spectroscopy (“dual-comb spectroscopy”; DCS) is a laser-based technique that can bridge this sensing gap by providing high-precision, high-accuracy, and high-temporal-resolution detection and quantification of trace gases over kilometer-length scales, connecting local and regional observations. A single DCS system can also provide spatial resolution for source/sink attribution with the addition of a few minor optical elements, enabling cross-validation of other observations (e.g., Total Carbon Column Observing Network [TCCON], Orbiting Carbon Observatory [OCO-2/3], Greenhouse Gases Observing Satellite [GOSAT-1/2][).

54 ENVIRONMENTAL SCIENCES↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Laser-based combustion diagnostics, such as single-pulse UV Raman spectroscopy and visible Raman spectroscopy, have been successfully applied to optically-accessible rocket-like test articles. If an independent pressure measurement is available, Raman major species concentration measurements can also provide a temperature measurement. However it is desirable to obtain a Raman-derived temperature measurement without the need for simultaneous pressure measurement, especially when chamber pressure may vary spatially. This report describes Raman temperature measurements obtained by exploiting the variation in shape of the H2 Raman spectrum. Hydrogen is advantageous since it is ubiquitous in H2-O2 systems and its Raman spectrum is simpler than for other diatomics. However the influence of high pressure on the H2 Raman spectrum must be investigated. At moderate pressures, well below those of rocket engines, the Raman spectra of O2 and N2 are known to become featureless due to collisional broadening.

Joseph A Wehrmeyer↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

Response Surface Methods for Spatially-Resolved Optical Measurement Techniques

Response surface methods (or methodology), RSM, have been applied to improve data quality for two vastly different spatial ly-re solved optical measurement techniques. In the first application, modern design of experiments (MDOE) methods, including RSM, are employed to map the temperature field in a direct-connect supersonic combustion test facility at NASA Langley Research Center. The laser-based measurement technique known as coherent anti-Stokes Raman spectroscopy (CARS) is used to measure temperature at various locations in the combustor. RSM is then used to develop temperature maps of the flow. Even though the temperature fluctuations at a single point in the flowfield have a standard deviation on the order of 300 K, RSM provides analytic fits to the data having 95% confidence interval half width uncertainties in the fit as low as +/-30 K. Methods of optimizing future CARS experiments are explored. The second application of RSM is to quantify the shape of a 5-meter diameter, ultra-light, inflatable space antenna at NASA Langley Research Center.

Danehy, P. M.↗

Response Surface Methods For Spatially-Resolved Optical Measurement Techniques

Response surface methods (or methodology), RSM, have been applied to improve data quality for two vastly different spatially-resolved optical measurement techniques. In the first application, modern design of experiments (MDOE) methods, including RSM, are employed to map the temperature field in a direct-connect supersonic combustion test facility at NASA Langley Research Center. The laser-based measurement technique known as coherent anti-Stokes Raman spectroscopy (CARS) is used to measure temperature at various locations in the combustor. RSM is then used to develop temperature maps of the flow. Even though the temperature fluctuations at a single point in the flowfield have a standard deviation on the order of 300 K, RSM provides analytic fits to the data having 95% confidence interval half width uncertainties in the fit as low as +/- 30 K. Methods of optimizing future CARS experiments are explored. The second application of RSM is to quantify the shape of a 5-meter diameter, ultra-lightweight, inflatable space antenna at NASA Langley Research Center. Photogrammetry is used to simultaneously measure the shape of the antenna at approximately 500 discrete spatial locations. RSM allows an analytic model to be developed that describes the shape of the majority of the antenna with an uncertainty of 0.4 mm, with 95% confidence. This model would allow a quantitative comparison between the actual shape of the antenna and the original design shape. Accurately determining this shape also allows confident interpolation between the measured points. Such a model could, for example, be used for ray tracing of radio-frequency waves up to 95 GHz. to predict the performance of the antenna.

Danehy, P. M.↗

Search for 3D topological superconductors using laser-based spectroscopy (Final Technical Report)

The three-dimensional topological superconductor (3D TSC) is a novel quantum phase of matter that is predicted to exhibit exotic thermal and electrical properties, which may serve applications ranging from precision thermal management and sensing technologies to fault-tolerant quantum information processing. Over the past decade, there has been an intensive effort to realize 1D and 2D TSCs by artificially engineering them from combinations of already existing materials. For example, coupling conventional superconductors to spin-orbit coupled 1D nanowires or to 2D topological insulator surfaces by the proximity effect provides a route to realizing 1D and 2D TSCs respectively. However no artificial engineering strategy is available for a 3D TSC. Therefore, current searches are limited to intrinsically superconducting compounds whose topological properties are difficult to predict. The overarching goal of this project was to realize and to identify 3D TSCs in bulk single crystals using novel laser-based spectroscopic techniques. One major thrust was to develop ultralow temperature and ultra-high-resolution angle-resolved photoemission spectroscopy (ARPES) to directly measure the dispersion of Majorana excitations that are predicted to exist on the surfaces of 3D TSCs. Another major thrust was to develop a rational route to realize 3D TSCs by identifying their precursor phases. It is theoretically proposed that the critical fluctuations of certain ordered electronic phases can mediate Cooper pairing in odd-parity channels and lead to topological superconductivity. Therefore, 3D TSCs may potentially emerge upon suppressing these inversion symmetry broken precursor phases to a critical point with external perturbations such as pressure, strain or even light. To test this hypothesis, we studied candidate materials using a suite of symmetry-sensitive optical probes including rotational anisotropy optical second harmonic generation (RA-SHG) and time-resolved coherent phonon spectroscopy, all operable under high-pressure and low temperature environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Nanoscale ultrafast lattice modulation with a free-electron laser

Ultrafast optical laser-based techniques have enabled the probing of atomistic processes at their intrinsic temporal scales with femto- and attosecond resolution. However, the long wavelengths of optical lasers have prevented their interrogation and manipulation with nanoscale spatial specificity. Advances in hard X-ray free-electron lasers have enabled progress in developing X-ray transient-grating spectroscopy, a technique that aims to coherently control elementary excitations with nanoscale X-ray standing waves. Thus far, the realization of this technique at the nanoscale has been a challenge. Here we demonstrate X-ray transient-grating spectroscopy with spatial periods of the order of 10 nm via the subfemtosecond synchronization of two hard X-ray pump pulses at a precisely controlled crossing angle. This creates a thermal grating and preferentially excites coherent longitudinal acoustic phonon modes with the transient-grating wavevector. On probing with a third, variably delayed, X-ray pulse with the same photon energy, time-and-wavevector-resolved measurements of the modulation of the induced scattering intensity provide evidence of ballistic thermal transport at nanometre scales. Finally, these results highlight the potential of X-ray transient gratings as a powerful platform for studying nanoscale transport in condensed matter and the coherent control of nanoscale dynamics.

nonlinear optics↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Electronics Free Laser Sensing Technology for Minerals and Technology Elements

This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.

HCM Sensor↗

Laser Materials Processing for NASA's Aerospace Structural Materials

Lasers are useful for performing operations such as joining, machining, built-up freeform fabrication, and surface treatment. Due to the multifunctional nature of a single tool and the variety of materials that can be processed, these attributes are attractive in order to support long-term missions in space. However, current laser technology also has drawbacks for space-based applications. Specifically, size, power efficiency, lack of robustness, and problems processing highly reflective materials are all concerns. With the advent of recent breakthroughs in solidstate laser (e.g., diode-pumped lasers) and fiber optic technologies, the potential to perform multiple processing techniques in space has increased significantly. A review of the historical development of lasers from their infancy to the present will be used to show how these issues may be addressed. The review will also indicate where further development is necessary to realize a laser-based materials processing capability in space. The broad utility of laser beams in synthesizing various classes of engineering materials will be illustrated using state-of-the art processing maps for select lightweight alloys typically found on spacecraft. Both short- and long-term space missions will benefit from the development of a universal laser-based tool with low power consumption, improved process flexibility, compactness (e.g., miniaturization), robustness, and automation for maximum utility with a minimum of human interaction. The potential advantages of using lasers with suitable wavelength and beam properties for future space missions to the moon, Mars and beyond will be discussed. The laser processing experiments in the present report were performed using a diode pumped, pulsed/continuous wave Nd:YAG laser (50 W max average laser power), with a 1064 nm wavelength. The processed materials included Ti-6AI-4V, Al-2219 and Al-2090. For Phase I of this project, the laser process conditions were varied and optimized to see the effects on melt-quenching, cladding/alloying (using the pre-placed powder technique), and cutting. Key parameters such laser power, pulse repetition frequency, process speed, and shield gas flow and the observed process characteristics such as plasma formation during laser/material interaction, have been reported for all experimental runs. Preliminary materials characterization of select samples was carried out using various microscopy, diffraction, spectroscopy and microhardness test methods, and reported. Select nitridation results of Ti-6AI-4V using nitrogen assist gas indicated the successful formation of hard titanium nitrides with much higher hardness (2180 kg/sq mm). A cost-effective and simple powder delivery system has been successfully fabricated for the further experimentation in Phase H.

Nagarathnam, Karthik↗

Spectroscopic detection of biological NO with a quantum cascade laser

Two configurations of a continuous wave quantum cascade distributed feedback laser-based gas sensor for the detection of NO at a parts per billion (ppb) concentration level, typical of biomedical applications, have been investigated. The laser was operated at liquid nitrogen temperature near lambda = 5.2 microns. In the first configuration, a 100 m optical path length multi-pass cell was employed to enhance the NO absorption. In the second configuration, a technique based on cavity-enhanced spectroscopy (CES) was utilized, with an effective path length of 670 m. Both sensors enabled simultaneous analysis of NO and CO2 concentrations in exhaled air. The minimum detectable NO concentration was found to be 3 ppb with a multi-pass cell and 16 ppb when using CES. The two techniques are compared, and potential future developments are discussed.

NASA Discipline Environmental Health↗

Two-Photon Fluorescence Microscope for Microgravity Research

A two-photon fluorescence microscope has been developed for the study of biophysical phenomena. Two-photon microscopy is a novel form of laser-based scanning microscopy that enables three-dimensional imaging without many of the problems inherent in confocal microscopy. Unlike one-photon optical microscopy, two-photon microscopy utilizes the simultaneous nonlinear absorption of two near-infrared photons. However, the efficiency of two-photon absorption is much lower than that of one-photon absorption, so an ultra-fast pulsed laser source is typically employed. On the other hand, the critical energy threshold for two-photon absorption leads to fluorophore excitation that is intrinsically localized to the focal volume. Consequently, two-photon microscopy enables optical sectioning and confocal performance without the need for a signal-limiting pinhole. In addition, there is a reduction (relative to one-photon optical microscopy) in photon-induced damage because of the longer excitation wavelength. This reduction is especially advantageous for in vivo studies. Relative to confocal microscopy, there is also a reduction in background fluorescence, and, because of a reduction in Rayleigh scattering, there is a 4 increase of penetration depth. The prohibitive cost of a commercial two-photon fluorescence-microscope system, as well as a need for modularity, has led to the construction of a custom-built system (see Figure 1). This system includes a coherent mode-locked titanium: sapphire laser emitting 120-fs-duration pulses at a repetition rate of 80 MHz. The pulsed laser has an average output power of 800 mW and a wavelength tuning range of 700 to 980 nm, enabling the excitation of a variety of targeted fluorophores. The output from the laser is attenuated, spatially filtered, and then directed into a confocal scanning head that has been modified to provide for side entry of the laser beam. The laser output coupler has been replaced with a dichroic filter that reflects the longer-wavelength excitation light and passes the shorter-wavelength fluorescence light. Also, the confocal pinhole has been removed to increase the signal strength. The laser beam is scanned by a twoperpendicular- axis pair of galvanometer mirrors through a pupil transfer lens into the side port of an inverted microscope. Finally, the beam is focused by a 63-magnification, 1.3-numerical- aperture oil-immersion objective lens onto a specimen. The pupil transfer lens serves to match the intermediate image planes of the scanning head and the microscope, and its location is critical. In order to maximize the quality of the image, (that is, the point spread function of the objective lens for all scan positions), the entire system was modeled in optical-design software, and the various free design parameters (the parameters of the spatial-filter components as well as the separations of all of the system components) were determined through an iterative optimization process. A modular design was chosen to facilitate access to the optical train for future fluorescence correlation spectroscopy and fluorescence-lifetime experiments.

Fischer, David G.↗