Search NASA⌕ Search

SEARCH · Search NASA

Results for “laundry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Laundry Study for a Lunar Outpost

In support of the Constellation Program, which will return humans to the moon and establish an Outpost, NASA has conducted an analysis of crew clothing and laundry options. Single-use or "disposable" clothing has been used from Apollo until International Space Station (ISS) missions, meaning that clothes were worn for the whole mission or thrown away when they became too dirty to wear any longer. This is justified for short duration missions; however, as the Constellation mission will last much longer and each individual Outpost mission is expected to last up to 180 days, mission goals and launch penalties for mass and volume may lead to a different conclusion. Furthermore, the habitat atmosphere pressure and therefore oxygen volume percentage will be different from ISS or Shuttle. Almost daily EVA sorties will be a norm during Outpost exploration missions. All of these factors will have impacts on selection of crew clothing and laundry options for Outpost missions. Mass and volume estimates for disposable crew clothing have been shown as a major penalty in long-duration manned space exploration missions in previous analyses. Assuming disposable clothing like ISS, Equivalent System Mass (ESM) of crew clothing and hygiene towels was estimated to be 11,000 kg or about 11% of total life support system ESM for a 10-year Lunar Outpost mission with 4 crew members. Ways to reduce this clothing penalty, which are discussed in this paper, include: a) Reduce clothing supply rate through using clothes made of advanced fabrics; b) Reduce daily usage rate by extending its use duration before disposing; and c) Use laundry and reusable clothing. The report summarizes recent research efforts in advanced clothing, proposed clothing supply rates for Exploration missions, results of a trade-off study between disposable clothing and laundry, and conclusions and suggestions for Constellation Program clothing.

Ewert, Michael↗

Phased Construction Completion Report for Decontamination Laundry Demolition at the Oak Ridge National Laboratory

This Phased Construction Completion Report (PCCR) documents completion of demolition, waste disposition, and slab stabilization activities of Building 2523 (Decontamination Laundry) for the Oak Ridge National Laboratory (ORNL). The Decontamination Laundry is located directly north of the intersection of White Oak Avenue and the 2519 Access Road. This demolition scope included the removal of the above-grade structures and facility components associated with Building 2523. This scope included the removal of Building 2523 (and all remaining contents inside), Trailer 2523A (and all remaining contents inside), an above-grade wastewater tank, and a wooden access porch connecting Buildings 2523 and Trailer 2523A. On the north side of Building 2523, above-grade portions of selected remaining foundations/stairs were removed from former Building 2517 to make room to stage waste containers. Building 2621 is west of the Laundry Building and Buildings 2547 and 2649 are to the east, while Building 2525 is to the north. Building 2523 is located within Bethel Valley Exposure Unit (EU) 3. The total area of the EU is approximately 39 acres. The area within EU 3 is bounded by First Street on the west, Central Avenue on the north, Third Street on the east and south. The slab of Building 2523 has been stabilized with a cap of flowable fill concrete and asphalt to contain residual radiological contamination and to provide surface suitable for vehicle parking. No below-grade demolition actions were performed during this task.

99 GENERAL AND MISCELLANEOUS↗

The chemical/physical and microbiological characteristics of typical bath and laundry waste waters

Chemical/physical and microbiological characteristics are studied of typical bath and laundry waters collected during a 12 day test in which the untreated waste waters were reused for toilet flush. Most significant changes were found for ammonia, color, methylene blue active substances, phosphates, sodium, sulfates, total organic carbon, total solids, and turbidity in comparison with tap water baseline. The mean total number of microorganisms detected in the waste waters ranged from 1 million to 10 to the 7th power cells/m1 and the mean number of possible coliforms ranged from 10 to the 5th power to 1 million. An accumulation of particulates and an objectible odor were detected in the tankage used during the 12 day reuse of the untreated waste waters. The combined bath and laundry waste waters from a family of four provided 91 percent of the toilet flush water for the same family.

Hypes, W. D.↗

Single phase space laundry development

This paper describes a newly designed, 2.7 Kg (6 pound) capacity, laundry machine called the Single Phase Laundry (SPSL). The machine was designed to wash and dry crew clothing in a micro-gravity environment. A prototype unit was fabricated for NASA-JSC under a Small Business Innovated Research (SBIR) contract extending from September 1990 to January 1993. The unit employs liquid jet agitation, microwave vacuum drying, and air jet tumbling, which was perfected by KC-135 zero-g flight testing. Operation is completely automated except for loading and unloading clothes. The unit uses about 20 percent less power than a conventional household appliance.

Colombo, Gerald V.↗

Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water

An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.

Hypes, W. D.↗

Solar Hot Water for an Industrial Laundry--Fresno, California

Final report describes an integrated wastewater-heat recovery system and solar preheating system to supply part of hot-water requirements of an industrial laundry. Large retrofit solar-water-heating system uses lightweight collectors.

Source record↗

Is a Space Laundry Needed for Exploration?

Future human space exploration missions will lengthen to years, and keeping crews clothed without a huge resupply burden is an important consideration for habitation systems. A space laundry system could be the solution; however, the resources it uses must be accounted for and must win out over the very reliable practice of bringing along enough spare underwear. Through NASA's Logistics Reduction and Repurposing project, trade off studies have been conducted to compare current space clothing systems, life extension of that clothing, traditional water based clothes washing and other sanitizing techniques. The best clothing system of course depends on the mission and assumptions, but in general, analysis results indicate that washing clothes on space missions will start to pay off as mission durations push past a year.

Ewert, Michael K.↗

Dirty dishes or dirty laundry? Comparing two methods for quantifying American consumers' preferences for load management in a smart home

One challenge of transitioning to renewable energy is that household electricity use and renewable generation are often misaligned. Smart home energy management systems hold promise for shifting usage to match generation, but these systems need to be designed with the occupants’ preferences in mind. The purpose of the present research is to compare two approaches for collecting and modeling consumers’ load management preferences, both of which are amenable to use in a home energy management system. Specifically, we examine the performance of Simple Multi-Attribute Rating Technique Exploiting Ranks (SMARTER) and Analytic Hierarchy Process (AHP) in quantifying consumers’ preferences regarding air temperature (air conditioning and heating), water heating, dishwashing, clothes washing and drying, monetary costs, environmental impacts, and comfort/convenience. Two studies are presented: Study 1 examines the SMARTER approach, and Study 2 focuses on the AHP approach. In both studies, online surveys (N SMARTER = 956 and N AHP = 1023) were conducted to elicit preferences from participants across the United States. The preferences modeled by both approaches were validated based on (a) their ability to predict participants’ choices in a Discrete Choice Experiment and (b) their convergence with previous research on load-shifting behavior. The validation procedure suggests that the SMARTER approach is superior in modeling consumers’ preferences for load management. Overall, this research lays the groundwork for designing a smart home interface capable of collecting occupants’ preferences and using those preferences to deliver improved occupant comfort, lower operating costs, reduced environmental impact, and more significant demand response than exists today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ozone as a laundry agent on orbit and on the ground

Ozone (03), is the strongest commercial oxidizing agent for aqueous systems and may be ideal for space station laundering operations. It can be generated electronically from air in situ. It kills virtually all microorganisms, attacks many organics and inorganics, and breaks down stable ring structures of benzene and related oils when coupled with ultra violet radiation. It cleans and disinfects in cold water without the need for detergent. It leaves no residues. Ozone permits up to 90% wash water recycling and it eliminates wash time, water volume, and recycling problems of a detergent rinse. Ozone is self purging and converts spontaneously to oxygen. It can be rapidly purged by well established catalytic and thermal processes. Scaling of an ozone laundering system for space station may have commercial applications in a consumer model for home use.

Agosto, William N.↗

FLC Notable Technology Award Oleo-Furan Surfactant

It’s a well-kept secret that laundry detergents are harmful to the environment. The important chemical in laundry detergent, called a surfactant. Surfactants are the workhorses of laundry detergent and soaps, and they're attracted to things like grease on your hands and dirt in your clothes to wash them away. Surfactants are used in everything from shampoo, hand soap, laundry detergent, and cosmetics. Many current surfactants are made from petroleum feedstock. These petroleum-derived building blocks come with a big carbon footprint. As the need for greener feedstock alternatives for synthesizing surfactants became obvious, manufacturers turned to natural oils, such as palm kernel and coconut oil. However, these oils are costly, particularly in areas where they are not domestically produced, and using them for surfactant synthesis competes with the food supply chain. Surfactants deactivate and do not work in hard water. Hard water is common - 85% of the U.S. water supply is considered hard because of the presence of small metal ions. These metal ions cover the surfactants making them useless. To solve this problem, many manufacturers add chemicals called chelators to bind the metal ions and make the water less hard, enhancing the effectiveness of the laundry detergent. However, this solution leads to more problems, including increased cost of detergent production and a large output of environmentally harmful chemicals. There remains a strong need for effective laundry detergents that do not negatively impact the environment and are available to consumers at an affordable cost. The American Cleaning Institute (ACI), a surfactant manufacturer organizing body, is emphasizing commitment to developing bio-renewable alternatives to current surfactants in laundry detergents. That’s why chemists at SIRONIX Renewables partnered with Los Alamos National Laboratory to further develop Oleo-furan surfactants (OFS). OFS are a new class of non-toxic, non-irritating surfactants for laundry detergent. It is the only surfactant that performs effectively in cold and hard water without chelators to bind the metal ions in hard water. OFS can be produced readily from sustainable, bio-derived molecules. They are multi-functional molecules - performing the role of a surfactant and a chelator in one - and are completely bio-degradable. OFS does not rely on petroleum feedstock and is synthesized from non-food, bio-renewable cellulosic feedstock. OFS solves each of the pertinent problems facing detergents and our environment today.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Washing Out the Competition

AJT Associates, Inc. (AJT) worked with NASA to develop a revolutionary ozone-based laundry system. AJT's TecH2Ozone(R) wash system presents its customers with an energy-efficient, cost-effective, and environmentally safe way to perform commercial laundering. TecH2Ozone significantly reduces the amount of water and chemical used as compared to traditional commercial laundry systems. This reduction has resulted in lower cost and shorter wash cycles. And due to the reduced use of chemicals, a significant portion of the rinse water is recycled back into the system for reuse. TecH2Ozone customers, such as hotels and other large commercial laundry facilities, have felt the benefits of this equipment. Because of the reduced cycle times, fewer washers are needed and there is a notable increase in the cleanliness of the laundry. The reduction in chemical residues is a boon to customers with allergies and those prone to skin irritation from chemicals retained in regular laundry. AJT Associates, Inc. (AJT) worked with NASA to develop a revolutionary ozone-based laundry system. AJT's TecH2Ozone(R) wash system presents its customers with an energy-efficient, cost-effective, and environmentally safe way to perform commercial laundering.

Source record↗

Cleanroom Garment Silicone Contamination

The slide presentation reviews actions taken at Goddard Space Flight Center (GSFC) to eliminate contamination by silicone in clean rooms. Background information includes facilities and hardware affected by silicon contamination, a discussion of the negative aspects of silicone contamination, clean room garments, and how the problem was identified at GSFC. Actions taken by the GSFC Contamination Engineering Group and lessons learned are detailed. Results include: awareness of the silicone issue in laundry, increase in infrastructure and support of the testing lab, establishment of protocols for garment verification, closer relationship established with laundry and converter, specifications for laundry services and garments were strengthened, all consumables are tested before use in clean rooms, and established procedures were used to identify and treat silicone found on face masks.

Geer, Wayne↗

Clothes Cleaning Research for Space Exploration

As the National Aeronautics and Space Administration (NASA) plans to establish a sustainable presence on the Moon to prepare for missions to Mars, there is an increased need to find effective and sustainable laundry solutions that are compatible with space travel and reduce the need for clothing resupply. Research and development to overcome resource constraints in space can lead to new products and practices on Earth. This paper describes a collaboration between NASA and Procter & Gamble (P&G) to advance their individual goals as well as provide additional benefits to humanity through more sustainable use of resources. In particular, the two organizations have been working together since August 2020 to advance state-of-the-art, environmentally friendly laundry solutions. Both traditional and novel approaches are being considered and held up against strict resource constraints that may exist in space missions or on Earth in the future. The results of this work are expected to contribute to NASA’s strategic goal of extending human presence deeper into space and to the Moon for sustainable long-term exploration and utilization. Likewise, the collaboration will advance one of P&G’s 2030 corporate sustainability goals by promoting water savings among its 5 billion consumers.

laundry↗

Analysis of microplastics in bivalves along Fourmile Branch

Microplastics are commonly found near wastewater treatment facilities with the source originating typically from fibers associated with laundry detergents. Fourmile branch would have limited laundry associated effluent and does not receive any input from water originating from upstream industry sources, therefore microplastics would have originated from Site operations or through atmospheric deposition which are both unexplored pathways. In order to assess environmental inventory effects on the biota, water samples were collected from sampling locations along Fourmile Branch on the Savannah River Site using plankton nets and grab samples at Fourmile Branch locations (i.e., FM-2B, FM-A7, and FM6). Fourmile Branch has a long history of receiving industrial effluents from site operations as well effluent from the site’s wastewater treatment plant. Water samples and the debris collected in the nets were rinsed with deionized water and sieved to remove the larger fractions of plastics (4000-2000 µm) and retain fractions <500 µm. The water samples were analyzed for the type and size of plastics by μ-Raman, mass spectrometry, and Fourier Transform Infrared Spectroscopy (FTIR) methods. Previously collected bivalves were prepared into thin sections and analyzed using microscopy.

54 ENVIRONMENTAL SCIENCES↗

Reverse osmosis for wash water recovery in space vehicles.

Tests were carried out on both synthetic and real wash water derived from clothes laundry to determine the utility of reverse osmosis in recovering the water for recycle use. A blend membrane made from cellulose di- and triacetates, and a cross-linked cellulose acetate/methacrylate were evaluated. Both were found acceptable. A number of detergents were evaluated, including a cationic detergent, sodium dodecyl sulfate, potassium palmitate, and sodium dodecylbenzenesulfonate. The tests were all made at a temperature of 165 F to minimize microbial growth. Long-term (15 to 30 day) runs were made at 600 and 400 psi on laundry water which was pretreated either by alum addition and sand filtration or by filtration only through 0.5 micron filters. A 30-day run was made using a 2-in. diameter by 22-in. long spiral module at 400 psig with filtering as the pretreatment. The membrane fouling by colloidal matter was found to be controllable. The unit produced initially 55 gal/day and 27 gal/day after 30 days.

Lawrence, R. W.↗

Advanced Clothing System

The goal of the Advanced Clothing System (ACS) is to use advanced commercial off-theshelf fibers and antimicrobial treatments with the goal of directly reducing the mass and volume of a logistics item. The current clothing state-of-the-art on the International Space Station (ISS) is disposable, mostly cotton-based, clothing with no laundry provisions. Each clothing article has varying use periods and will become trash. The goal is to increase the length of wear of the clothing to reduce the logistical mass and volume. The initial focus has been exercise clothing since the use period is lower. Various ground studies and an ISS technology demonstration have been conducted to evaluate clothing preference and length of wear. The analysis indicates that use of ACS selected garments (e.g. wool, modacrylic, polyester) can increase the breakeven point for laundry to 300 days.

Schlesinger, Thilini↗

Advanced Clothing System

The goal of the Advanced Clothing System (ACS) is to use advanced commercial off-the-shelf fibers and antimicrobial treatments with the goal of directly reducing the mass and volume of a logistics item. The current clothing state-of-the-art on the International Space Station (ISS) is disposable, mostly cotton-based, clothing with no laundry provisions. Each clothing article has varying use periods and will become trash. The goal is to increase the length of wear of the clothing to reduce the logistical mass and volume. The initial focus has been exercise clothing since the use period is lower. Various ground studies and an ISS technology demonstration have been conducted to evaluate clothing preference and length of wear. The analysis indicates that use of ACS selected garments (e.g. wool, modacrylic, polyester) can increase the breakeven point for laundry to 300 days.

Broyan, James↗