Search NASA⌕ Search

SEARCH · Search NASA

Results for “lensless imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

Error metrics for partially coherent wave fields

Lensless imaging methods that account for partial coherence have become very common in the past decade. However, there are no metrics in use for comparing partially coherent light fields, despite the widespread use of such metrics to compare fully coherent objects and wave fields. Here, we show how reformulating the mean squared error and Fourier ring correlation in terms of quantum state fidelity naturally generalizes them to partially coherent wave fields. We report these results fill an important gap in the lensless imaging literature and will enable quantitative assessments of the reliability and resolution of reconstructed partially coherent wave fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Achieving high spatial resolution in a large field-of-view using lensless x-ray imaging

X-ray ptychography, a powerful scanning lensless imaging technique, has become attractive for nondestructively imaging internal structures at nanoscale. Stage positioning overhead in conventional step-scan ptychography is one of the limiting factors on the imaging throughput. In this work, we demonstrate the use of advanced fly scan ptychography to achieve high-resolution ptychograms of modern integrated circuits on a large field-of-view at millimeter scale. By completely removing stage overheads between scan points, the imaging time for millimeter-size sample can be significantly reduced. Furthermore, we implement the orthogonal probe relaxation technique to overcome the variation of illumination across the large scan area as well as local vibrations. The capability of x-ray ptychography shown here is broadly applicable for various studies, which requires both high spatial resolution and large scan area.

47 OTHER INSTRUMENTATION↗

In situ high-harmonic microscopy of a nanostructured solid

Nanostructured optical surfaces allow exquisite control over linear and nonlinear light interactions, where the surface actively creates new frequencies up to high-order harmonics of an intense infrared driving laser field. The function and performance of these surfaces depend sensitively on the distribution of the high-harmonic fields in and between the nanostructured elements, as the high-harmonic wavelength becomes comparable to the nanoscale features of the surface. Imaging the nonlinear response at the active surface with nanometer resolution would greatly benefit the optimization of the metasurface's function. Here we demonstrate an approach to lensless imaging of extreme ultraviolet high harmonics that resolves the amplitude and phase of nonlinear polarization at the active nanostructured surface of an MgO crystal. Imaging the near-field distribution of high harmonics is the gateway to optimized functional high-harmonic metasurfaces and the integration of high harmonics on a chip.

36 MATERIALS SCIENCE↗

Maskless Fourier transform holography

Fourier transform holography is a lensless imaging technique that retrieves an object's exit-wave function with high fidelity. It has been used to study nanoscale phenomena and spatio-temporal dynamics in solids, with sensitivity to the phase component of electronic and magnetic textures. However, the method requires an invasive and labor-intensive nanopatterning of a holography mask directly onto the sample, which can alter the sample properties, forces a fixed field-of-view, and leads to a low signal-to-noise ratio at high resolution. In this work, we propose using wavefront-shaping diffractive optics to create a structured probe with full control of its phase at the sample plane, circumventing the need for a mask. We demonstrate in silico that the method can image nanostructures and magnetic textures and validate our approach with a visible light-based experiment. The method enables investigation of a plethora of phenomena at the nanoscale including magnetic and electronic phase coexistence in solids, with further uses in soft and biological matter research.

Keskinbora, Kahraman↗

Dose-efficient automatic differentiation for ptychographic reconstruction

Ptychography, as a powerful lensless imaging method, has become a popular member of the coherent diffractive imaging family over decades of development. The ability to utilize low-dose X-rays and/or fast scans offers a big advantage in a ptychographic measurement (for example, when measuring radiation-sensitive samples), but results in low-photon statistics, making the subsequent phase retrieval challenging. Here, we demonstrate a dose-efficient automatic differentiation framework for ptychographic reconstruction (DAP) at low-photon statistics and low overlap ratio. As no reciprocal space constraint is required in this DAP framework, the framework, based on various forward models, shows superior performance under these conditions. It effectively suppresses potential artifacts in the reconstructed images, especially for the inherent periodic artifact in a raster scan. We validate the effectiveness and robustness of this method using both simulated and measured datasets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

Wave optics simulations for new soft x-ray beamlines at NSLS-II

In this work, we performed fully- and partially-coherent synchrotron emission and propagation simulations with the "Synchrotron Radiation Workshop" computer code to analyze the performance of two soft X-ray beamlines under development at the National Synchrotron Light Source II: Soft X-ray Nanoprobe (SXN), and Angle-Resolved Photoemission Spectroscopy (ARPES) and Resonant Inelastic X-ray Scattering (RIXS) Imaging (ARI). The SXN beamline intends to provide high flux and high spatial resolution coherent soft X-ray imaging capabilities using both zone plate and lensless coherent imaging techniques. The ARI beamline aims to perform high flux ARPES and RIXS experiments with a focal spot size at the sample approaching 100 nm using highly-demagnifying mirrors in Kirkpatrick-Baez geometry. To accurately calculate the resolution and the degree of X-ray coherence provided by the two state-of-the-art beamlines, partial coherence effects are required to be taken into account in wave optics simulations for these two beamlines. In this talk, beamline performance parameters such as spot size, degree of coherence, flux, and energy resolution at the sample are presented. The effects of mirror surface slope errors on beamline performance were studied and some suggestions for further optimization are discussed.

36 MATERIALS SCIENCE↗

Simultaneous imaging and diffraction in the dynamic diamond anvil cell

The ability to visualize a sample undergoing a pressure-induced phase transition allows for the determination of kinetic parameters, such as the nucleation and growth rates of the high-pressure phase. For samples that are opaque to visible light (such as metallic systems), it is necessary to rely on x-ray imaging methods for sample visualization. Here, we present an experimental platform developed at beamline P02.2 at the PETRA III synchrotron radiation source, which is capable of performing simultaneous x-ray imaging and diffraction of samples that are dynamically compressed in piezo-driven diamond anvil cells. This setup utilizes a partially coherent monochromatic x-ray beam to perform lensless phase contrast imaging, which can be carried out using either a parallel- or focused-beam configuration. The capabilities of this platform are illustrated by experiments on dynamically compressed Ga and Ar. Melting and solidification were identified based on the observation of solid/liquid phase boundaries in the x-ray images and corresponding changes in the x-ray diffraction patterns collected during the transition, with significant edge enhancement observed in the x-ray images collected using the focused-beam. These results highlight the suitability of this technique for a variety of purposes, including melt curve determination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Two-photon X-ray ghost microscope

This article presents a non-classical imaging mechanism that produces a diffraction-limited and magnified ghost image of the internal structure of an object through the measurement of intensity fluctuation correlation formed by two-photon interference. In principle, the lensless X-ray ghost imaging mechanism may achieve a spatial resolution determined by the wavelength and the angular diameter of the X-ray source, ∼ λ /Δ θ s , with possible reduction caused by additional optics. In addition, it has the ability to image select “slices” deep within an object, which can be used for constructing 3D view of its internal structure.

Smith, Thomas A. (ORCID:0000000275427047)↗

Ptychographic reconstructions performed in real time and offline have equivalent quality

Abstract Ptychography is a burgeoning imaging technique that enables high-resolution, lensless reconstruction of complex samples by analysing overlapping diffraction patterns, making it invaluable in fields like materials science, biology, and nanotechnology. Real-time ptychographic reconstructions are gaining interest in the scientific community as they provide immediate feedback. Yet their potential to replace offline reconstructions remains uncertain, in part due to questions about the quality of the resulting images. This study quantitatively compares real-time and offline reconstructions at different overlap conditions. Offline reconstructions, using all diffraction patterns at once, and real-time reconstructions, where new frames are added to the reconstructions in small chunks as the diffraction patterns are recorded, were indistinguishable and identical in reconstruction quality. These results hold consistently across all tested overlap ratios. This study represents the first quantitative analysis of real-time ptychographic reconstruction using a growing dataset, demonstrating the potential for real-time reconstructions to replace or at least complement offline reconstructions.

Science & Technology - Other Topics↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

Lensless X-Ray Nanoimaging: Revolutions and opportunities

Lensless x-ray nanoimaging is providing 3D views of a wide range of materials with a spatial resolution better than 20 nanometers. These advances are enabled in part by dramatic gains in coherent x-ray flux, but they also rely on advances in signal processing to obtain images from coherent diffraction data. Here, we outline the various imaging approaches, the associated reconstruction methods, and highlight opportunities for future advances.

42 ENGINEERING↗