A 45Ah Lithium ion (Li-Ion) battery comprised of 5 Yardney prismatic cells was evaluated to replace the silver-zinc cells in the Extra-vehicular Mobility Unit (EMU). Tests determined that the five cell battery can meet the mission objective of 500 duty cycles and maintain a minimum voltage of 16.0 V without an individual cell voltage dropping below 3.0V. Forty real time cycles were conducted to develop BOL trend data. Decision to switch to accelerated cycling for the remaining 460 cycles was made since Real Time cycling requires 1 day/cycle. Conclusions indicate that battery replacement would indeed be prudent.
In this work, we propose a hybrid model for Li-ion battery discharge and aging prediction that leverages fleet-wide data to predict future capacity drops.The model is built upon an hybrid approach merging physics-based and empirical equations, as well as neural network models in a recurrent neural network cell. The hybrid physics-informed neural network can predict voltage discharge cycles given the loading profile, and estimate the used capacity of the battery under random-loading conditions by tracking aging parameters connected to the residual capacity of the battery. By merging information on the battery aging parameters with existing fleet-wide aging data, the model can predict the future residual capacity of the battery that is being monitored, and therefore enable predictions of voltage discharge curves far ahead in the battery life cycle. We validated the approach using the NASA Prognostics Data Repository Battery data-set, which contains experimental data on Li-ion batteries discharged at random loading conditions in a controlled environment. The approach also allows the identification of discrepancies between the battery aging trend and the trend observed at the fleet level, so that batteries behaving differently from the rest of the fleet can be subject to closer monitoring and further testing to refine predictions.
The International Space Station (ISS) primary Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. When deployed, they will be the largest Li-Ion batteries ever utilized for a human-rated spacecraft. This paper will include an overview of the ISS Li-Ion battery system architecture, the Li-Ion battery design and development, controls to limit potential hazards from the batteries, and the status of the Li-Ion cell and ORU life cycle testing.
The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the ISS is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace Ni-H2 batteries approaching the end of their useful life and concurrently funded a Li-Ion ORU (Orbital Replacement Unit) and cell life testing project. The first set of 6 Li-ion battery replacements was launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit cycling and the status of the Li-Ion cell and ORU life cycle testing.
Extensive use of Li-ion batteries in electric vehicles, electronics, and other energy storage applications has resulted in a need to recycle valuable metals Li, Mn, Ni, and Co in these devices. In this work, an aqueous mixture of glycolic and lactic acid is shown as an excellent leaching agent to recover these critical metals from spent Li-ion laptop batteries combined with cathode and anode coatings without adding hydrogen peroxide or other reducing agents. An aqueous acid mixture of 0.15 M in glycolic and 0.35 M in lactic acid showed the highest leaching efficiencies of 100, 100, 100, and 89% for Li, Ni, Mn, and Co, respectively, in an experiment at 120 °C for 6 h. Subsequently, the chelate solution was evaporated to give a mixed metal-hydroxy acid chelate gel. Pyrolysis of the dried chelate gel at 800 °C for 15 h could be used to burn off hydroxy acids, regenerating lithium nickel manganese cobalt oxide, and the novel method presented to avoid the precipitation of metals as hydroxide or carbonates. The Li, Ni, Mn, and Co ratio of regenerated lithium nickel manganese cobalt oxide is comparable to this metal ratio in pyrolyzed electrode coating and showed similar powder X-ray diffractograms, suggesting the suitability of α-hydroxy carboxylic acid mixtures as leaching agents and ligands in regeneration of mixed metal oxide via pyrolysis of the dried chelate gel.
State-of-the-Art lithium-ion battery technology is limited by specific energy and thus not sufficiently advanced to support the energy storage necessary for aerospace needs, such as all-electric aircraft and many deep space NASA exploration missions. In response to this technological gap, our research team at NASA Glenn Research Center has been active in formulating concepts and developing testing hardware and components for Li-metal battery cell chemistries. Lithium metal anodes combined with advanced cathode materials could provide up to five times the specific energy versus state-of-the-art lithium-ion cells (1000 Whkg versus 200 Whkg). Although Lithium metal anodes offer very high theoretical capacity, they have not been shown to successfully operate reversibly.
In 2010, the ISS Program began the development of Lithium-Ion (Li-Ion) batteries to replace the aging Ni-H2 batteries on the primary Electric Power System (EPS). After the Boeing 787 Li-Ion battery fires, the NASA Engineering and Safety Center (NESC) Power Technical Discipline Team was tasked by ISS to investigate the possibility of Thermal Runaway Propagation (TRP) in all Li-Ion batteries used on the ISS. As part of that investigation, NESC funded a TRP test of an ISS EPS non-flight Li-Ion battery. The test was performed at NASA White Sands Test Facility in October 2016. This paper will discuss the work leading up to the test, the design of the test article, and the test results.
The International Space Station (ISS) Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-ion cell life testing project. This paper will include an overview of the ISS Li-Ion battery system architecture and the progress of the Li-ion battery design and development.
Explore the source record for details and available documents.
International Space Station Lithium-Ion Battery Start-Up.The International Space Station (ISS) primary Electric Power System (EPS) was originally designed to use Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. As the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-Ion ORU and cell life testing project. The first set of 6 Li-ion battery replacements were launched in December 2016 and deployed in January 2017. This paper will discuss the Li-ion battery on-orbit start-up and the status of the Li-Ion cell and ORU life cycle testing.
When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35 percent depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. With the oldest 12 Ni-H2 battery ORUs cycling since September 2006, the first set of six was replaced by Li-Ion batteries in December 2016; the second set of six is planned for replacement in September 2018. This paper will include an overview of the ISS Li-Ion battery system architecture, on-orbit status of the first 6 batteries, start up of the second 6 batteries, and the status of the Li-Ion cell and ORU life cycle testing.
Lithium-Ion (Li-Ion) batteries are fast becoming the battery chemistry of choice for aerospace applications requiring (rechargeable) power supplies. These batteries offer high-energy density and high-specific energy combined with excellent rate capability and cycle potential. The increased energy content and operational characteristics of this system require defined safety and handling procedures to ensure the safe implementation. Standardized approaches to defining, determining, and addressing safety, handling, and qualification for Li-Ion batteries have been developed and published as an NESC-sponsored Li-Ion Battery Guidelines Document. A data base was established cataloging cells and batteries that have been considered for aerospace applications.
As lithium-ion battery energy densities continue to rise, managing the heat and pressure generated during failure events has become increasingly critical. Safety systems must effectively relieve pressure without releasing sparks, flames, or particulate matter, requiring robust filtration solutions. The challenge is compounded by the reduced free volume available for gas expansion in high-density designs, which increases the demands on these filters. While significant progress has been made through experimental studies and modeling efforts to understand the behavior of ejecta during battery failures, there remains a pressing need for practical, rule-of-thumb sizing parameters. These parameters would help correlate high-energy waste streams with appropriate filter design, ensuring reliable containment and safety. This talk will explore recent experimental findings in this area and discuss the potential pathways for developing these essential sizing guidelines.
When originally launched, the International Space Station (ISS) primary Electric Power System (EPS) used Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The electricity for the space station is generated by its solar arrays, which charge batteries during insolation for subsequent discharge during eclipse. The Ni-H2 batteries were designed to operate for ten years at a 35% depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. For service beyond that period, upgraded Li-Ion Orbital Replacement Units (ORUs) were designed. These are the largest Li-Ion batteries ever utilized for a human rated spacecraft. The first set of six Ni-H2 batteries was replaced by Li-Ion batteries in December 2016; the second set of six was launched in September 2018 and installed in March 2019. The third set of six were launched in September 2019. Three batteries were installed in September 2019, with the remaining three to be installed in January 2020. This paper will include a brief overview of the ISS Li-Ion battery system architecture, start up of the second and third set of 6 batteries and the on-orbit status of all 18 batteries, plus the status of the Li-Ion cell life testing.