Search NASA⌕ Search

SEARCH · Search NASA

Results for “light WIMPs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Extending light WIMP searches to single scintillation photons in LUX

© 2020 American Physical Society. We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a twofold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c2 WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Light weakly interacting massive particles

Light WIMPs are dark matter particle candidates with weak scale interaction with the known particles, and mass in the GeV to 10's of GeV range. Hints of light WIMPs have appeared in several dark matter searches in the last decade. The unprecedented possible coincidence into tantalizingly close regions of mass and cross section of four separate direct detection experimental hints and a potential indirect detection signal in gamma rays from the galactic center, aroused considerable interest in our field. Even if these hints did not so far result in a discovery, they have had a significant impact in our field. Herein we discuss the evidence for and against light WIMPs as dark matter candidates and discuss future relevant experiments and observations

79 ASTRONOMY AND ASTROPHYSICS↗

Updated constraints on the dark matter interpretation of CDMS-II-Si data

Here we present an updated halo-dependent and halo-independent analysis of viable light WIMP dark matter candidates which could account for the excess observed in CDMS-II-Si. We include recent constraints from LUX, PandaX-II, and PICO-60, as well as projected sensitivities for XENON1T, SuperCDMS SNOLAB, LZ, DARWIN, DarkSide-20k, and PICO-250, on candidates with spin-independent isospin conserving and isospin-violating interactions, and either elastic or exothermic scattering. We show that there exist dark matter candidates which can explain the CDMS-II-Si data and remain very marginally consistent with the null results of all current experiments, however such models are highly tuned, making a dark matter interpretation of CDMS-II-Si very unlikely. We find that these models can only be ruled out in the future by an experiment comparable to LZ or PICO-250.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vibration and EMF Backgrounds at NEXUS

NEXUS (Northwestern EXperimental Underground Site) is a dark matter detector prototyping and calibration facility at Fermilab. It is part of the SuperCDMS collaboration, which is focused on exploring light-WIMP parameter space. The NEXUS cryostat, typically operated at temperatures of about 10 mK, is located 107 meters underground in the MINOS Near Detector Hall to reduce cosmic ray backgrounds. We characterized the vibrational and electro-magnetic frequency (EMF) backgrounds surrounding the cryostat and investigated how these backgrounds transfer into the detector itself.

43 PARTICLE ACCELERATORS↗

Light Dark Matter Analysis Using NO$\nu$A Near Detector

Dark matter (DM) is believed to account for 85$\%$ of the matter content of the Universe. The leading dark matter candidate is the WIMP (weakly interacting massive particles). Light dark matter (LDM) refers to WIMP candidates with a mass of less than 1 GeV. The concept of LDM has been developed in order to explain the 511 keV $\gamma$-rays from the galactic bulge, as observed by the INTEGRAL satellite. There are a lot of candidates for light DM, and these candidates span a wide range of potential masses and couplings to the visible sector. Probing the vast parameter space of light-dark matter requires a correspondingly broad experimental program that can include neutrino fixed target experiments. NOvA is a high luminosity long-baseline fixed-target accelerator neutrino experiment at Fermilab that can provide a potentially interesting probe in searching for signatures of DM scattering with electrons in its near detectors. We aim to search for the MeV-scale dark matter particles that might be generated within the NuMI beam and produce detectable electron scattering signals in NOvA Near Detector. In this talk, we present our analysis of the single electron events using a simulated sample and show the sensitivity of the NOvA experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3 keV nr where signals from dark matter particles of <10 GeV/c 2 masses are expected. The coherent elastic neutrino-nucleus scattering (CE ν NS) by solar 8 B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV nr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on 8 B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar 8 B flux measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal WIMPs and the scale of new physics: global fits of Dirac dark matter effective field theories

We assess the status of a wide class of WIMP dark matter (DM) models in light of the latest experimental results using the global fitting framework GAMBIT. We perform a global analysis of effective field theory (EFT) operators describing the interactions between a gauge-singlet Dirac fermion and the Standard Model quarks, the gluons and the photon. In this bottom-up approach, we simultaneously vary the coefficients of 14 such operators up to dimension 7, along with the DM mass, the scale of new physics and several nuisance parameters. Our likelihood functions include the latest data from Planck, direct and indirect detection experiments, and the LHC. For DM masses below 100 GeV, we find that it is impossible to satisfy all constraints simultaneously while maintaining EFT validity at LHC energies. For new physics scales around 1 TeV, our results are influenced by several small excesses in the LHC data and depend on the prescription that we adopt to ensure EFT validity. Furthermore, we find large regions of viable parameter space where the EFT is valid and the relic density can be reproduced, implying that WIMPs can still account for the DM of the universe while being consistent with the latest data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter detection capabilities of a large multipurpose Liquid Argon Time Projection Chamber

Liquid Argon Time Projection Chambers are planned to comprise a central role in the future of the U.S. High Energy Physics neutrino program. In particular, this detector technology will form the basis for the 40 kton Deep Underground Neutrino Experiment (DUNE) . Here in this paper we take as a starting point the dual phase far detector design proposed by the DUNE experiment and ask what changes are necessary to allow one of the four 10 kt modules to be sensitive to heavy Weakly Interacting Massive Particle (WIMP) dark matter. We show that with control over backgrounds and the use of low radioactivity argon, which may be commercially available on that timescale, along with a significant increase in light detection, one DUNE-like module gives a competitive WIMP detection sensitivity, particularly above a dark matter mass of 100 GeV.

47 OTHER INSTRUMENTATION↗

Measurements and models of enhanced recombination following inner-shell vacancies in liquid xenon

Electron-capture decays of 125 Xe and 127 Xe , and double-electron-capture decays of 124 Xe , are backgrounds in searches for weakly interacting massive particles (WIMPs) conducted by dual-phase xenon time projection chambers such as LUX-ZEPLIN (LZ). These decays produce signals with more light and less charge than equivalent-energy 𝛽 decays and correspondingly overlap more with WIMP signals. We measure three electron-capture charge yields in LZ: the 1.1 keV M-shell, 5.2 keV L-shell, and 33.2 keV K-shell at drift fields of 193 and 96.5 V/cm. The LL double-electron-capture decay of 124 Xe exhibits even more pronounced shifts in charge and light. We provide a first model of double-electron-capture charge yields using the link between ionization density and electron-ion recombination, and identify a need for more accurate calculations. Finally, we discuss the implications of the reduced charge yield of these decays and other interactions creating inner-shell vacancies for future dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DarkSide-20k sensitivity to light dark matter particles

The dual-phase liquid argon time projection chamber is presently one of the leading technologies to search for dark matter particles with masses below 10 GeV c$^{−2}$. This was demonstrated by the DarkSide-50 experiment with approximately 50 kg of low-radioactivity liquid argon as target material. The next generation experiment DarkSide-20k, currently under construction, will use 1,000 times more argon and is expected to start operation in 2027. Based on the DarkSide-50 experience, here we assess the DarkSide-20k sensitivity to models predicting light dark matter particles, including Weakly Interacting Massive Particles (WIMPs) and sub-GeV c$^{−2}$ particles interacting with electrons in argon atoms. With one year of data, a sensitivity improvement to dark matter interaction cross-sections by at least one order of magnitude with respect to DarkSide-50 is expected for all these models. A sensitivity to WIMP–nucleon interaction cross-sections below 1 × 10$^{−42}$ cm$^{2}$ is achievable for WIMP masses above 800 MeV c$^{−2}$. With 10 years exposure, the neutrino fog can be reached for WIMP masses around 5 GeV c$^{−2}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spin-dependent constraints on blind spots for thermal singlino-higgsino dark matter with(out) light singlets

The LUX experiment has recently set very strong constraints on spin-independent interactions of WIMP with nuclei. These null results can be accommodated in NMSSM provided that the effective spin-independent coupling of the LSP to nucleons is suppressed. Here, we investigate thermal relic abundance of singlino-higgsino LSP in these so-called spin-independent blind spots and derive current constraints and prospects for direct detection of spin-dependent interactions of the LSP with nuclei providing strong constraints on parameter space. We show that if the Higgs boson is the only light scalar the new LUX constraints set a lower bound on the LSP mass of about 300 GeV except for a small range around the half of Z 0 boson masses where resonant annihilation via Z 0 exchange dominates. XENON1T will probe entire range of LSP masses except for a tiny Z 0 -resonant region that may be tested by the LZ experiment. These conclusions apply to general singlet-doublet dark matter annihilating dominantly to $t\bar{t}$. Presence of light singlet (pseudo)scalars generically relaxes the constraints because new LSP (resonant and non-resonant) annihilation channels become important. Even away from resonant regions, the lower limit on the LSP mass from LUX is relaxed to about 250 GeV while XENON1T may not be sensitive to the LSP masses above about 400 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

The MAGIS-100 Experiment and a Future, Kilometer-scale Atom Interferometer

The dearth of signals unambiguously attributable to WIMP dark matter motivates exploring new parameter space, particularly the ultra-light dark matter (ULDM) regime, where the signal is not scattering events but wave phenomena. The proliferation of quantum technologies has enabled searches for ULDM at previously inaccessible sensitivity. One such technology is atom interferometry which can measure time-dependent fluctuations in the energy spacing of atoms as well as in the light-travel time across the apparatus, enabling searches for ULDM and gravitational waves, respectively. In this talk, I will review the science case for long baseline atom interferometers, such as MAGIS-100 at Fermilab, provide an update on the experiment’s status, and discuss the need for a future, kilometer-scale atom interferometer which would achieve unprecedented sensitivity to ULDM and gravitational waves in the “Mid-Band” region between LIGO and LISA.

Temples, Dylan J. [Fermilab] (ORCID:00000001601725↗

Dark matter and dark radiation from the early universe with a modulus coupled to the PQMSSM

The supersymmetrized DFSZ axion model is especially compelling in that it contains 1. the SUSY solution to the gauge hierarchy problem, 2. the Peccei-Quinn (PQ) solution to the strong CP problem and 3. the Kim-Nilles solution to the SUSY μ problem. In a string setting, where a discrete R-symmetry ($Z$$^{R}_{24}$ for example) may emerge from the compactification process, a high-quality accidental axion (accion) can emerge from the accidental, approximate remnant global U(1) PQ symmetry where the decay constant f a is linked to the SUSY breaking scale, and is within the cosmological sweet zone. In this setup, one also expects the presence of stringy remnant moduli fields Φ i . Here, we consider the situation of a single light modulus Φ coupled to the PQMSSM in the early universe, with mixed axion plus higgsino-like WIMP dark matter. We evaluate dark matter and dark radiation production via nine coupled Boltzmann equations and assess the severity of the cosmological moduli problem (CMP) along with dark matter and dark radiation production rates. We find that typically the light modulus mass should be m Φ ≳ 10 4 TeV to avoid the moduli-induced dark matter overproduction problem. If one is able to (anthropically) tune the modulus field amplitude, we find a value of Φ 0 ≲ 10 –7 m P would be required to solve the overall CMP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Beam Dump eXperiment

Hadronic matter makes about 14% of the known universe. The remaining 86% is Dark Matter (DM). Since it does not interact with the ordinary matter via electromagnetic force, DM is not visible and, to date, it escaped detection. The search for Dark Matter (DM) is one of the hottest topic in modern physics. Despite the increasing number of astrophysical and cosmological observations proving the existence, so far no particle physics experiment has detected DM yet. Up to now, most of the experimental efforts have been focused on the so called WIMP (Weakly Interacting Massive Particle) paradigm, which predicts heavy DM (10 GeV-10 TeV mass range) interacting with Standard Model (SM) particles via the weak force mediators (W or Z bosons). More recently, due to the lack of clear evidence of WIMPs, other models of DM gained the interest of the physics community. These models consider Light DM particles (LDM), in MeV-GeV mass range. Among LDM theories, the Dark Photon theory predicts the existence of a Dark Sector interacting with SM particles via a new massive vector boson (Dark Photon, Heavy Photon or A0), mediator of a new force. This scenario, despite being theoretically well motivated, is remarkably experimentally unexplored. The Beam Dump eXperiment (BDX), is an approved experiment at Jefferson Lab (JLab), aiming to discover the DM predicted witihn the Dark Photon theory. The experiment uses the CEBAF (Continuous Electron Beam Accelerator Facility) 11 GeV electron beam, impinging on the JLab Hall-A beam-dump, to produce a beam of DM particles, detected by a ~ 1 m3 detector made of thallium doped cesium iodide (CsI(Tl)) crystals located ~ 20 m downstream. In order to achieve excellent background rejection, the experimental setup includes active vetos and passive shielding surrounding CsI(Tl) crystals. Given the weakness of the DM-SM interaction, the scattering of a DM particle in the BDX detector is a rare event. Therefore, the characterization of the expected background is a critical aspect of the experiment. Both cosmogenic and penetrating SM particles produced by the beam interaction in the dump contribute to the background of the experiment. While the cosmogenic contribution can be measured during the experiment when the beam is off, beam-related background can only be estimated via Monte Carlo (MC) simulations. Therefore, a careful assessment of possible systematics introduced by the MC is needed. The beam-correlated background characterization was made by measuring the muon flux produced by the interaction of the CEBAF beam with Hall-A dump in a dedicated experimental campaign in spring 2018 [1]. The comparison to the ?ux predicted by MC allowed us to validate the BDX simulation framework. The reach of BDX, i.e. the region that the experiment can probe in the LDM theory parameter space, depends critically on the background rejection capability and signal detection effciency. For this reason, the detector setup was fine-tuned through a dedicated study. The response to LDM and background events was evaluated for different setups and selection cuts. As a result of this procedure, the configuration resulting in the best sensitivity was selected [2]. The reach calculation was performed taking into account the different LDM production mechanisms, including the contribution of secondary particles produced in the beam-dump. In particular, the effect of the secondary positrons annihilation was found to be extremely significant. In the majority of the sensitivity studies, this contribution is neglected, but recent results [3] [4] demonstrated that this process significantly enhances the sensitivity of lepton beam-dump experiments. Currently, the BDX collaboration is focused on the deployment and operation of a small detector, called BDX-MINI, built to perform a preliminary physics measurement searching for LDM at JLab. This test will pave the way to the realization of the full BDX experiment. The measurement is currently ongoing but results are expected by the end of this year. During my PhD I was involved in all aspects of the BDX experiment: design, simulation, prototyping and data analysis. The main results of my work are reported in this thesis. This manuscript is organized as follows: the first Chapter provides an introduction to the theory of LDM, with particular attention to the Dark Photon paradigm; the second Chapter illustrates the BDX experimental setup, the LDM production and detection mechanisms and the expected backgrounds; Chapter 3 and 4 describe, respectively, the BDX-HODO measurement, with a detailed description of the simulations, and the BDX experimental setup and analysis cuts optimization. Chapter 5 reports about BDXMINI detector characterization, calibration and sensitivity estimate. Finally, Chapter 6 describes in detail the calculation of the secondary positron annihilation contribution to the sensitivity of BDX and other electron-beam thick-target experiment.

Marsicano, Luca↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗