Self-steepening of light pulses.
Light pulses self steepening resulting from propagation in medium with intensity dependent refractive index
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Light pulses self steepening resulting from propagation in medium with intensity dependent refractive index
Self-steepening of light pulses due to propagation in medium with intensity-dependent index of refraction
Light pulses propagation in nonlinear laser medium, obtaining equations of motion for density matrix
Pulsed light source for the extreme ultraviolet
Night sky Cerenkov light detectors observations of pulsars CP 1133, NP 0532 and NP 0527, noting instrumental limitation in detecting ultrashort light pulses
Fluorescence produced by resonant coherent light pulse passing through medium assuming infinite relaxation times and negligible pulse attenuation
Fast large-aperture photometers directed at the zenith on clear nights near Minneapolis have recorded many light pulses in the msec time range, but aside from man-made events these were almost entirely due to Rayleigh-scattered distant lightning, with a residual very low rate (less than 0.1/hr) of unidentified pulses. It is argued that 1-msec light pulses seen in several previous experiments may also be mostly Rayleigh-scattered lightning, rather than fluorescent light due to electron precipitation from lightning-induced whistlers as previously proposed.
Light pulse demodulator using zero crossing technique to eliminate photomultiplier bandwidth and sensitivity limitations
Suitably configured whispering-gallery-mode (WGM) optical resonators have been proposed as delay lines for trains of short light pulses. Until now, it has been common practice to implement an optical delay line as a coiled long optical fiber, which is bulky and tends to be noisy. An alternative has been to implement an optical delay line as a coupled-resonator optical waveguide (a chain of coupled optical resonators), which is compact but limits the width of the pulse spectrum to the width of an optical resonance and thereby places a lower limit on the duration of a pulse. In contrast, a delay line according to the proposal could be implemented as a single WGM resonator, and the pulses delayed by the resonator could be so short that their spectral widths could greatly exceed the spectral width of any single resonance. The proposal emerged from theoretical and experimental studies of the propagation of a pulse train in a WGM resonator. An important element of the theoretical study was recognition that the traditional definition of group velocity in effect, the velocity of a single pulse comprising a packet of waves propagating in a medium, the responsivity of which is a monotonous function of frequency does not necessarily apply in the case of a WGM resonator or other medium having a spectrum consisting of discrete resonance peaks at different frequencies. A new definition of group velocity, applicable to a train of pulses propagating in such a medium, was introduced and found to lead to the discovery of previously unknown features of propagation. Notably, it was found that in a micro - sphere optical resonator that supports a suitable combination of WGM modes, the group velocity for a train of light pulses could be positive, zero, or negative. A positive group velocity could be so small that the delay could be much longer than the ring-down time of the resonator; a delay of such great length is impossible for a single pulse interacting with either a linearly responding lossless resonator or a coupled- resonator optical waveguide.
Apparent movement phenomena on cathode ray tube displays - threshold determinations of apparent movements of pulsed light sources
A high-temperature (1900 K) Seebeck coefficient apparatus is described in which small thermal gradients are generated in a sample by light pulses transmitted via light pipes. By employing an analog subtraction circuit, the Seebeck coefficient is displayed directly on an X-Y recorder. This technique presents a convenient, accurate, and rapid method for measuring the Seebeck coefficient in highly doped semiconductors as a function of temperature. The nature of the resulting display (X-Y recording) is a valuable tool in determining validity of the data. A straight line results (i.e., a minimum of hysteresis) only if all potential experimental errors are minimized. Under these conditions, the error of measurements of the Seebeck coefficient is estimated to be less than + or - 1 percent.
Millisecond-time-scale atmospheric light pulses induced by solar activity
An experimental study of the absorption of a laser light pulse in a transient, high-density, high-temperature plasma is presented. The plasma is generated around a metallic anode tip by a fast capacitive discharge occurring in vacuum. The amount of transmitted light is measured for plasmas made of different metallic ions in the regions of the discharge of high electronic density. Variation of the transmission during the laser pulse is also recorded. Plasma electrons are considered responsible for the very high absorption observed.
The results of processing the data on the shape of the EAS Cerenkov light pulses recorded by the extensive air showers (EAS) array are presented. The pulse FWHM is used to find the mean depth of EAS maximum.
Photomultiplier tube socket assembly with high gain and clean output signals for viewing organic scintillator light pulses
Multiple scattering contributions to lidar returns from turbid atmospheres are derived by means of an analytical theory. It is assumed that scattering takes place mainly at small angles except for one event that scatters the light backward. The phase functions are approximated by the sum of Gaussian functions of the scattering angle in both the forward and backward directions. The three-dimensional radiative transfer equation is transformed to a one-dimensional problem by means of Fourier transforms. Neumann solutions to the transformed equation of radiative transfer are then found. A number of examples are presented for cloud, fog and haze models. The results are found to be in satisfactory agreement with results obtained from the Monte Carlo analysis of Kunkel (1974) and the theory of light pulses doubly scattered by turbid atmospheres which was developed by Eloranta (1972).
Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.
Thermal inspections of a structure typically utilize a flash or quartz lamp heat source located on the same side of an infrared camera. The heat source provides light energy for heating while the infrared camera measures the surface transient temperature response. The inspection can be difficult for low emissivity surfaces for several reasons. First, the high intensity light can reflect off the surface and cause “burn-in” to the camera’s detector. The “burn-in” can take time for the sensors to recover and potentially damage the detector. Secondly, the heat source after pulsing, has a transient cool down component. The cool down component can be reflected and therefore superimposed over the structure’s thermal response which can cause an error (false defect indications) in the inspection. Lastly, the heat source is spectrally broad and therefore while heating, infrared components of the heat source can produce non-uniformity in the measured temperature field. Typically for the inspection of reflective surfaces, paint or other emissivity enhancing coatings are applied before inspection. In this paper, a pulsed light emitting diodes (PLED) heat source is used. The PLED heat source is spectrally narrow, contained within the visible band, and therefore not detectable by the infrared camera. The PLED heat source is configured to reduce any transient cool down components that could produce false defect indications. The PLED thermal inspections are compared to commercially available flash thermography inspections on unpainted aluminum samples with simulated corrosion and additively manufactured Ti-6AL-4V metal specimens.