At least 19 records

Light shift and light broadening in the Rb-87 maser.

A description of measurements of light-shift and light-broadening parameters for an Rb-87 maser operating between the field independent levels is reported. A parallel study of the spectral profile of the D1 pumping line is described. Comparison between the experimental results and theoretical calculations, taking into account the spatial inhomogeneity of the pumping light in the absorption cell, is presented.

Busca, G.↗

Low-Light-Shift Cesium Fountain without Mechanical Shutters

A new technique for reducing errors in a laser-cooled cesium fountain frequency standard provides for strong suppression of the light shift without need for mechanical shutters. Because mechanical shutters are typically susceptible to failure after operating times of the order of months, the elimination of mechanical shutters could contribute significantly to the reliability of frequency standards that are required to function continuously for longer time intervals. With respect to the operation of an atomic-fountain frequency standard, the term "light shift" denotes an undesired relative shift in the two energy levels of the atoms (in this case, cesium atoms) in the atomic fountain during interrogation by microwaves. The shift in energy levels translates to a frequency shift that reduces the precision and possibly accuracy of the frequency standard. For reasons too complex to describe within the space available for this article, the light shift is caused by any laser light that reaches the atoms during the microwave- interrogation period, but is strongest for near-resonance light. In the absence of any mitigating design feature, the light shift, expressed as a fraction of the standard fs frequency, could be as large as approx. 2 x 10(exp -11), the largest error in the standard. In a typical prior design, to suppress light shift, the intensity of laser light is reduced during the interrogation period by using a single-pass acoustooptic modulator to deflect the majority of light away from the main optical path. Mechanical shutters are used to block the remaining undeflected light to ensure complete attenuation. Without shutters, this remaining undeflected light could cause a light shift of as much as .10.15, which is unacceptably large in some applications. The new technique implemented here involves additionally shifting the laser wavelength off resonance by a relatively large amount (typically of the order of nanometers) during microwave interrogation. In this design, when microwave interrogation is not underway, the atoms are illuminated by a slave laser locked to the lasing frequency of a lower power master laser.

Enzer, Daphna↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗

Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

English, T. C.↗

Light shift effects in the Rb-87 maser

Previous work has shown the possibility to overcome the dependence of the Rb-87 maser frequency on light intensity by tuning the cavity at a proper setting. The conditions for this setting, called the light-independent frequency setting (LIFS), are carefully investigated. The results presented prove the existence of the LIFS and provide a new criterion for an automatic cavity tuning of the Rb maser.

Busca, G.↗

Cavity tuning and light-shift in the Rb-87 maser

A new method for tuning the cavity of the Rb-87 maser is proposed. It is based on the existence of a cavity tuning for which the maser frequency is independent on the light intensity. The features of this method are evaluated theoretically and tested experimentally. Preliminary results obtained by using a closed loop feedback electronic system for tuning the cavity are given.

Busca, G.↗

Instrument Measures Shift In Focus

Optical components tested at wavelengths from ultraviolet to infrared. Focus-shift-measuring instrument easy to use. Operated in lighted room, without having to make delicate adjustments while peering through microscope. Measures distance along which focal point of converging beam of light shifted by introduction of nominally plane parallel optical component into beam. Intended primarily for measuring focus shifts produced by windows and filters at wavelengths from 120 to 1,100 nanometers. Portable, compact, and relatively inexpensive for degree of precision.

Steimle, Lawrence J.↗

Gas scintillation drift chambers with wave shifter fiber readout

Results for a prototype xenon gas scintillation drift chamber are presented. Its operation is discussed using two types of light detection schemes: one based on an Anger camera geometry and one based on an array of wave-shifting light fibers. The results are judged to demonstrate the instrument's potential.

Sadoulet, Bernard↗

Planar Particle Imaging Doppler Velocimetry Developed

Two current techniques exist for the measurement of planar, three-component velocity fields. Both techniques require multiple views of the illumination plane in order to extract all three velocity components. Particle image velocimetry (PIV) is a high-resolution, high accuracy, planar velocimetry technique that provides valuable instantaneous velocity information in aeropropulsion test facilities. PIV can provide three-component flow-field measurements using a two-camera, stereo viewing configuration. Doppler global velocimetry (DGV) is another planar velocimetry technique that can provide three component flow-field measurements; however, it requires three detector systems that must be located at oblique angles from the measurement plane. The three-dimensional configurations of either technique require multiple (DGV) or at least large (stereo PIV) optical access ports in the facility in which the measurements are being conducted. Optical access is extremely limited in aeropropulsion test facilities. In many cases, only one optical access port is available. A hybrid measurement technique has been developed at the NASA Glenn Research Center, planar particle image and Doppler velocimetry (PPIDV), which combines elements from both the PIV and DGV techniques into a single detection system that can measure all three components of velocity across a planar region of a flow field through a single optical access port. In the standard PIV technique, a pulsed laser is used to illuminate the flow field at two closely spaced instances in time, which are recorded on a "frame-straddling" camera, yielding a pair of single-exposure image frames. The PIV camera is oriented perpendicular to the light sheet, and the processed PIV data yield the two-component velocity field in the plane of the light sheet. In the standard DGV technique, an injection-seeded Nd:YAG pulsed laser light sheet illuminates the seeded flow field, and three receiver systems are used to measure three components of velocity. The receiver systems are oriented at oblique angles to the light sheet in order to accurately resolve the three-component velocity. Each DGV receiver system contains two cameras, which share a common view of the illuminated flow through a beam-splitting cube. One camera views the illuminated flow directly (reference camera) and the second camera images the illuminated flow through an iodine vapor cell (signal camera). The laser frequency (wavelength) is adjusted so that the Doppler-shifted light from particles in the flow falls on an iodine absorption feature, see the following graph. The iodine vapor cell acts as a frequency-to-velocity filter by modulating the intensity of the transmitted light as a function of the flow velocity (Doppler shift). The ratio of the signal and reference images yields the component of the flow velocity along the bisector of the laser sheet propagation direction and the receiver system observation direction. The hybrid system employs a single-component DGV receiver system configured to simultaneously acquire PIV image data, as shown in the following diagram. The cameras used in the DGV receiver are replaced with PIV frame-straddling cameras, and the receiver system views the illuminated light sheet plane at 90 (as in the standard PIV configuration).

Wernet, Mark P.↗

Development and applications of tunable, narrow band lasers and stimulated Raman scattering devices for atmospheric lidar

The main thrust of the program was the study of stimulated Raman processes for application to atmospheric lidar measurements. This has involved the development of tunable lasers, the detailed study of stimulated Raman scattering, and the use of the Raman-shifted light for new measurements of molecular line strengths and line widths. The principal spectral region explored in this work was the visible and near-IR wavelengths between 500 nm and 1.5 microns. Recent alexandrite ring laser experiments are reported. The experiments involved diode injection-locking, Raman shifting, and frequency-doubling. The experiments succeeded in producing tunable light at 577 and 937 nm with line widths in the range 80-160 MHz.

Wilkerson, Thomas D.↗

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.↗

Scale-covariant theory of gravitation and astrophysical applications

A scale-covariant theory of gravitation is presented which is characterized by a set of equations that are complete only after a choice of the scale function is made. Special attention is given to gauge conditions and units which allow gravitational phenomena to be described in atomic units. The generalized gravitational-field equations are derived by performing a direct scale transformation, by extending Riemannian geometry to Weyl geometry through the introduction of the notion of cotensors, and from a variation principle. Modified conservation laws are provided, a set of dynamical equations is obtained, and astrophysical consequences are considered. The theory is applied to examine certain homogeneous cosmological solutions, perihelion shifts, light deflections, secular variations of planetary orbital elements, stellar structure equations for a star in quasi-static equilibrium, and the past thermal history of earth. The possible relation of the scale-covariant theory to gauge field theories and their predictions of cosmological constants is discussed.

Canuto, V.↗

Trace gas concentrations, intertropical convergence, atmospheric fronts, and ocean currents in the tropical Pacific

Descriptions of the intertropical convergence zones (ITCZ) in the tropical Pacific have been obtained from shipboard measurements of Rn-222, CO, and CH4 in combination with conventional meteorological data and satellite images. The intertropical convergence zone is marked by light shifting waves near an area of heavy cloud cover and precipitation, and appears to be located north and south of the south equatorial current. A 'second' ITCZ with the same atmospheric features was encountered just north of the south equatorial current in the Southern Hemisphere. Atmospheric Rn-222 increases north of the ITCZ and serves as a sensitive indicator for this atmospheric boundary.

Wilkniss, P. E.↗

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.↗

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.↗