Search NASA⌕ Search

SEARCH · Search NASA

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Light source and method for making a light source

A light source fabrication process to fabricate a customized light source includes attaching a plurality of light emitting diodes to a circuit board, where each light emitting diode is configured to emit light within a same wavelength range. Further, the light source fabrication process includes applying a first phosphor layer to a first set of light emitting diodes of the plurality of light emitting diodes and applying a second phosphor layer to a second set of light emitting diodes of the plurality of light emitting diodes. The phosphor layers are applied to the light emitting diodes using one of a screen printing process and an inkjet printing process. The first phosphor layer is different from and has different optical properties from the second phosphor layer.

42 ENGINEERING↗

APS upgrade: Commissioning the world’s first light source based on swap-out injection

The Advanced Photon Source (APS) has recently completed a major upgrade, replacing its 25-year-old storage ring with a cutting-edge hybrid seven-bend achromat lattice enhanced by six additional reverse bends. The new design achieves a natural emittance of 42 pm-rad, enabling the production of X-rays up to 500 times brighter than those generated by the original APS. A key innovation of the upgrade is the implementation of a swap-out injection scheme, which replaces entire depleted bunches instead of performing traditional top-up injection. This approach enables on-axis injection to accommodate for the reduced dynamic aperture resulting from strong focusing. This paper outlines the commissioning process, shares initial operating experience with swap-out injection, and presents performance data for new systems such as the bunch-lengthening cavity.

Sajaev, Vadim [Argonne, PHY]↗

Electron beam emittance at operational intensity in fourth-generation synchrotron light sources

For synchrotron light sources, the brightness of user X-ray beams is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of electron bunches combined with a very small transverse beam size. Consequently, the particle density is much higher than in machines of previous generations, leading to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction, and bunch lengthening provided by higher-harmonic RF systems, to identify optimal combinations of machine and beam parameters.

43 PARTICLE ACCELERATORS↗

Macromolecular crystallography and biology at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) has significantly impacted the field of biology by providing advanced capabilities for probing the structure and dynamics of biological molecules with high precision. The ultrashort coherent X-ray pulses from the LCLS have enabled ultrafast, time-resolved, serial femtosecond crystallography that is inaccessible at conventional synchrotron light sources. Since the facility's founding, scientists have captured detailed insights into biological processes at atomic resolution and fundamental timescales. The ability to observe these processes in real time and under conditions closely resembling their natural state is transforming our approach to studying biochemical mechanisms and developing new medical and energy applications. This work recounts some of the history of the LCLS, advances in biological research enabled by the LCLS, key biological areas that have been impacted and how the LCLS has helped to unravel complex biological phenomena in these fields.

59 BASIC BIOLOGICAL SCIENCES↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

High repetition-rate 0.5 Hz broadband neutron source driven by the Advanced Laser Light Source

Neutron beams are an essential tool to investigate material structure and perform nondestructive analysis, as they give unique access to element composition, thus ideally complementing density analysis allowed by standard x-rays investigation. Laser-driven neutron sources, though compact and cost-effective, currently have lower average flux than conventional neutron sources, due to the limited repetition rate of the lasers used so far. However, advancements in laser technology allow nowadays to address this challenge. Here, we report results obtained at the Advanced Laser Light Source characterizing stable production of broadband (0.1–2 MeV) neutrons produced at a high repetition rate (0.5 Hz). The interaction of laser pulses of 22 fs duration and 3.2 J on-target energy with 2-μm-thick tantalum targets produced protons in the Target Normal Sheath Acceleration (TNSA) regime up to 7.3 MeV. These protons were subsequently converted into neutrons by (p,n) reactions in lithium fluoride (LiF). Activation measurements and bubble detectors were used to characterize neutron emissions, with a neutron fluence of up to ∼1.4×105 neutrons/shot/sr and energies mainly between a few hundred of kilo-electron volt and 2 MeV. The total neutron yield was ∼5×105 neutrons/shot. This paves the way for numerous applications, e.g., in homeland security, materials science, or cultural heritage.

Physics↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

The Effect of Spectral Resolution of Light Sources on Photopic and a-opic Quantities

There is a growing interest in including light source spectrum in advanced lighting software tools and simulations. Given that traditional lighting software tools have been used primarily for calculating photometric quantities, their simplifying assumptions may not be suitable for calculating other a-opic quantities. Commonly used simulation tools use three values to represent the three primary colors (red, green, and blue), but others have expanded the number of bands (i.e., the spectral resolution) to 9, 27, or 81 in an attempt to more accurately represent variations in light source spectrum and downstream spectrally-derived quantities. It remains unclear, however, to what extent spectral resolution affects calculated quantities. To address this gap, a numerical analysis was completed using a large spectral power distribution database (n = 1,302 light sources). Calculated illuminance, a-opic irradiance, luminous efficacy of radiation (LER), melanopic efficacy of radiation (MER), and melanopic to photopic (M/P) ratio were compared for spectral resolutions of 3 and 9 bands compared to a baseline of 81 bands. Across all examined lighting quantities, considerable errors—a mean absolute percent error of 18.4%—were found when using 3 band calculations. These were reduced to 4% for 9 band calculations. The errors varied by metric and light source type. The results suggest that the use of 9 bands can more accurately characterize performance of different light source types across a range of metrics compared to using 3 bands.

Abboushi, Belal K.↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Resonant metasurface‐enabled quantum light sources for single‐photon emission and entangled photon‐pair generation

Light encodes information in multiple degrees of freedom (e.g., frequency, amplitude, and phase), enabling high‐speed, high‐bandwidth communication through fiber optics. Unlike classical light, quantum light (single or entangled photons) can transmit quantum states over long distances without loss of coherence, thereby coherently interconnecting quantum nodes for distributed quantum entanglement. Quantum light sources are critical for developing scalable quantum networks aimed at distributed quantum computing, quantum teleportation, and secure quantum communications. However, existing quantum light sources suffer from limited integrability, insufficient spectral and spatial tunability, and inefficiencies in achieving mass‐produced, deterministic, on‐demand quantum light generation. These limitations significantly hinder progress toward direct, on‐chip integration with quantum processing units and detectors – an essential step toward scalable quantum networks. Resonant metasurfaces that leverage photonic modes – such as Mie resonances, guided‐mode resonances, or symmetry‐protected bound states in the continuum – offer strong spatial and temporal confinement of electromagnetic fields, characterized by high quality factors and small mode volumes. These metasurfaces greatly enhance linear and nonlinear light‐matter interactions, making them ideal for efficient on‐chip quantum light generation and manipulation. Here, we describe recent advances in nanoscale quantum light sources and quantum photonic state manipulation enabled by resonant metasurfaces. We also provide an outlook on next‐generation miniaturized quantum light sources achievable through materials innovations in quantum emitters, the co‐design of resonant metasurfaces, and ultimately, the heterogeneous integration of emerging layered van der Waals materials with resonant metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

Cassette for holding a planar light source with a thermally isolated driver board

A loadable cassette holds a planar light source, such as a flat OLED panel, along with a companion driver board in a manner that allows both the light source and driver board to be operatively and replaceably connected to a luminaire or lighting system. The cassette maintains an air gap between the light source and driver board so as to prevent heat produced by the driver board from damaging the light source.

42 ENGINEERING↗

Structural biology at the National Synchrotron Light Source II

The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.

36 MATERIALS SCIENCE↗

Improved Method for Evaluating and Specifying the Chromaticity of Light Sources

This article recommends a method for calculating and specifying light source chromaticity using the CIE 2015 10° color matching functions (CMFs), which, according to analysis of existing psychophysical experiment data, can reduce visual mismatch compared to specifications based on the traditional CIE 1931 2° CMFs. Specifically, this work evaluates, documents, and recommends for adoption a supporting system of measures to be used with the CIE 2015 10° CMFs: a new uniform chromaticity scale (UCS) diagram with coordinates (s, t), a measure of correlated color temperature (CCTst), and a measure of distance from the Planckian locus (Dst). It also presents options for updating nominal classification quadrangles. A complete method of this nature has not yet been standardized, which may be contributing to the slow uptake of the CIE 2015 CMFs. The proposed tools are analogous to u, v, CCT, Duv, and the ANSI C78.377 nominal classification quadrangles that are currently specified in the CIE 1960 UCS using the CIE 1931 2° CMFs. While conceptually equivalent, the differences between the current standard method and the new st system are important for reducing unintended mismatch in the chromaticity of light. Furthermore, the implications of changing chromaticity specification methods are identified by a comparison over a diverse set of real light source SPDs. Finally, as a step toward improving the design and specification of light sources for illumination purposes, we propose a process for implementing the recommendations.

42 ENGINEERING↗

A high-power, high-repetition-rate THz source for pump–probe experiments at Linac Coherent Light Source II

Experiments using a THz pump and an X-ray probe at an X-ray free-electron laser (XFEL) facility like the Linac Coherent Light Source II (LCLS II) require frequency-tunable (3 to 20 THz), narrow bandwidth (~10%), carrier-envelope-phase-stable THz pulses that produce high fields (>1 MV cm –1 ) at the repetition rate of the X-rays and are well synchronized with them. Herein, a two-bunch scheme to generate THz radiation at LCLS II is studied: the first bunch produces THz radiation in an electromagnet wiggler immediately following the LCLS II undulator that produces X-rays from the second bunch. The initial time delay between the two bunches is optimized to compensate for the path difference in THz transport. The two-bunch beam dynamics, the THz wiggler and radiation are described, as well as the transport system bringing the THz pulses from the wiggler to the experimental hall.

42 ENGINEERING↗

Transition radiation light sources

Transition radiation from nanotubes, nanosheets, and nanoparticles and in particular, boron nitride nanomaterials, can be utilized for the generation of light. Wavelengths of light of interest for microchip lithography, including 13.5 nm (91.8 eV) and 6.7 nm (185 eV), can be generated at useful intensities, by transition radiation light sources. Light useful for monitoring relativistic charged particle beam characteristics such as spatial distribution and intensity can be generated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗