Search NASASearch

SEARCH · Search NASA

Results for “lighting system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Specification Guidance for School Lighting Systems [Slides]

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. LED lighting is a common lighting technology being specified today and many options are available for replacement or integration with existing fluorescent lighting systems. This document intends to help school districts retrofit or replace existing lighting systems in order to improve the classroom and school environment and reduce energy consumption and associated carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Meta-Generalized Gradient Approximation for the Cavity-Dependent Exchange-Correlation Interaction in Strongly Coupled Light–Matter Systems

Strong light–matter coupling in optical cavities enables the manipulation of chemical and physical properties without altering molecular composition. Theoretical modeling of such phenomena requires exchange-correlation (XC) functionals that account for both electron–electron and electron–photon (ep) interactions within quantum electrodynamical density functional theory (QEDFT). In this work, we develop a meta-generalized gradient approximation (meta-GGA) specifically targeting the cavity-dependent XC interaction in strongly coupled light–matter systems. This novel approximation is built upon a new semilocal polarizability approximation, which draws from the jellium-with-a-gap model, and can be extended to a “global hybrid” variant that goes beyond the isotropic model from previous approximations. The polarizability model yields significantly improved dispersion coefficients and benchmark calculations with the cavity-dependent XC functional demonstrate improved agreement with QED Hartree–Fock (QED-HF) reference energies. Application to the regioselectivity of brominated nitrobenzene intermediates reveals the functional’s capacity to capture cavity-induced energetic shifts. In conclusion, our results advance the Jacob’s ladder of functionals for QEDFT and provide a practical tool for modeling polaritonic chemistry.

Approximation

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Iron Bonding with Light Elements: Implications for Planetary Cores Beyond the Binary System

Light element alloying in iron is required to explain density deficit and seismic wave velocities in Earth’s core. However, the light element composition of the Earth’s core seems hard to constrain as nearly all light element alloying would reduce the density and sound velocity (elastic moduli). The alloying light elements include oxidizing elements like oxygen and sulfur and reducing elements like hydrogen and carbon, yet their chemical effects in the alloy system are less discussed. Moreover, Fe-X-ray Absorption Near Edge Structure (Fe-XANES) fingerprints have been studied for silicate materials with ferrous and ferric ions, while not many X-ray absorption spectroscopy (XAS) studies have focused on iron alloys, especially at high pressures. To investigate the bonding nature of iron alloys in planetary interiors, we presented X-ray absorption spectroscopy of iron–nitrogen and iron–carbon alloys at high pressures up to 50 GPa. Together with existing literature on iron–carbon, –hydrogen alloys, we analyzed their edge positions and found no significant difference in the degree of oxidation among these alloys. Pressure effects on edge positions were also found negligible. Our theoretical simulation of the valence state of iron, alloyed with S, C, O, N, and P also showed nearly unchanged behavior under pressures up to 300 GPa. This finding indicates that the high pressure bonding of iron alloyed with light elements closely resembles bonding at the ambient conditions. We suggest that the chemical properties of light elements constrain which ones can coexist within iron alloys.

Advanced Photon Source

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter

Performance and long-term stability of the ICARUS-T600 scintillation light detection system

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \sim 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. Long-term behavior of PMT gains and timing resolution, demonstrate the robustness and reliability of the ICARUS scintillation light detection system and provide valuable input for the design and operation of future large-scale liquid argon detectors.

Raselli, Gian Luca [INFN, Perugia] (ORCID:00000002

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx \SI{1}{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx 1 \,\mathrm{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS

The ICARUS light detection system (Fermilab Italian summer student program 2023)

The ICARUS T600 detector is the largest Liquid Argon Time Projection Chamber ever used on a neutrino beam, and it acts as the far detector of the Short Baseline Neutrino program at Fermilab. Its purpose is the study of the possibility of the existence of a fourth sterile neutrino in the O(eV2) mass range that could take part in the neutrino oscillations. The light detection system of the ICARUS detector plays the role of localising in space and time the neutrino interactions taking place inside the detector, collecting the argon scintillation photons generated when an event occurs. This light detection system also has a crucial role in the trigger system and the rejection of the huge amount of background cosmic events, working together with the trigger request signals sent by the beam complex. In August 2023 part of the cables that are used to carry the signals from the photomultipliers to the electronics were replaced with a new model, because a deterioration of the quality of the signal inside the cables had previously been observed. An analysis of the performance of the new cables was carried out, comparing laser run data collected before and after the change of the cable model, and it was proved that the introduction of the new cables lead to a general improvement of the quality of the signals reaching the electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)

Performance and Stability Characterization of the ICARUS Light Detection System

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermilab, consists of two identical T300 modules filled with liquid argon. It is equipped with a Light Detection System (LDS) based on 360 8-inch Hamamatsu R5912-MOD photomultiplier tubes (PMTs) arranged behind the wire planes to collect Vacuum Ultraviolet (VUV, $\sim$ 128 nm) scintillation light. Operating under cryogenic conditions ( $\sim$ 87 K), the LDS is essential for determining the event start time (t0) with nanosecond precision for beam spill synchronization, improving longitudinal spatial resolution, and contributing to the event trigger and cosmic-ray mitigation. The performance of the LDS was investigated addressing both hardware and data analysis aspects. Following a progressive degradation in PMT gain observed during operations at FNAL, systematic gain measurements were first carried out from room temperature down to low temperatures. The results show stable performance at room temperature but a significant, irreversible reduction in gain at low temperatures. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable cryogenic operation. Currently, ongoing waveform analysis of the PMT signals is being performed to characterize signal shape, charge integration, and timing properties, aiming to refine and improve the agreement between experimental data and Monte Carlo simulations.

Saia, Clara [U. Catania (main); INAF, Catania; Cat

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

2x2 Demonstrator High-Coverage Light Readout System in a Novel LArTPC

DUNE is a long-baseline Liquid Argon Time Projection Chamber (LArTPC) neutrino oscillation experiment. Its near detectors, located at Fermi National Laboratory, will constrain systematic errors on far detector measurements. The 2x2 Demonstrator, a novel proof of concept prototype for the ND LArTPC, has a modular TPC design that mitigates event pileup in a high-occupancy nearline beam environment, further aided by a native 3D pixelated charge readout and a 30% coverage, low profile light readout. This will be the first large-scale LArTPC to utilize pixels in place of wire planes

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response - CRADA 653 (Abstract)

Light Emitting Diode (LED) adoption is critical for widespread energy savings from commercial outdoor lighting systems. A complaint from the public, concerns glare from LED light fixtures especially those with exposed LED arrays. This human factor study will examine luminance uniformity of the fixture aperture to identify parameters related to this response. The outcome will inform optical design by lighting manufacturers, retaining LED energy efficiency while mitigating glare. The results may also lead to improved industry standard glare metrics for lighting. Pacific Northwest National Laboratory’s (PNNL) Lighting Science and Technology Lab in Portland OR has a purpose-built apparatus with exposed LED arrays that have been used for prior work. It can easily be adapted for use in this experiment. Interchangeable templates will allow changing patterns for the stimulus. Glare ratings from the recruited subjects will be analyzed and reported in a peer-reviewed journal for application by luminaire manufacturers for improved products. The McClung Foundation’s interest is to better understand human perception of lighting, leading to more comfortable and effective visual environments. Members of the Foundation’s Technical Review Committee will be instrumental in reviewing the experimental design, analysis, and the final report. They will also help disseminate information about the results within the lighting community.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Brewer Recreational Facility Energy Modernization Project (Final Technical Report)

The project replaced a thirty-four-year-old metal halide lighting system on the City's primary athletic field with new energy efficient LED lighting, significantly reducing operating and maintenance cost while providing a safer environment, additional recreational opportunities, improved energy efficiency, and reduced light spillover.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Project Report: School Retrofit Demonstration of Lighting and Outlet Controls with LED Upgrades

A technology demonstration project funded by the U.S. Department of Energy (DOE) was hosted by Boston Public Schools (BPS). This project evaluated wireless controls technology for lighting systems and plug loads (energy consumed by devices plugged into electrical outlets), implemented along with LED lighting retrofits in two classrooms. This study assesses technology readiness and effectiveness to determine the deployment potential of the technology in schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI