Search NASA⌕ Search

SEARCH · Search NASA

Results for “line impedance estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distribution Grid Modeling Using Smart Meter Data

The knowledge of distribution grid models, including topologies and line impedances, is essential for grid monitoring, control and protection. However, such information is often unavailable, incomplete or outdated. The increasing deployment of smart meters (SMs) provides a unique opportunity to tackle this issue. This paper proposes a two-stage framework for distribution grid modeling using SM data. In the first stage, the network topology is identified by reconstructing a weighted Laplacian matrix of distribution networks. In the second stage, a least absolute deviations (LAD) regression model is developed for estimating line impedance of a single branch based on the nonlinear (inverse) power flow model, wherein a conductor library is leveraged to narrow down the solution space. The LAD regression model is originally a mixed-integer nonlinear program whose continuous relaxation is still non-convex. Furthermore, we specially address its convex relaxation and discuss the exactness. The modified regression model is then embedded within a bottom-up sweep algorithm to achieve the identification across the network in a branch-wise manner. Numerical results on the IEEE 13-bus, 37-bus and 69-bus test feeders validate the effectiveness of the proposed methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Software for a High-Performance Telerobot

A computer program for controlling a high-performance, force-reflecting telerobot has been developed. The goal in designing a telerobot-control system is to make the velocity of the slave match the master velocity, and the environmental force on the master match the force on the slave. Instability can arise from even small delays in propagation of signals between master and slave units. The present software, based on an impedance-shaping algorithm, ensures stability even in the presence of long delays. It implements a real-time algorithm that processes position and force measurements from the master and slave and represents the master/slave communication link as a transmission line. The algorithm also uses the history of the control force and the slave motion to estimate the impedance of the environment. The estimate of the impedance of the environment is used to shape the controlled slave impedance to match the transmission-line impedance. The estimate of the environmental impedance is used to match the master and transmission-line impedances and to estimate the slave/environment force in order to present that force immediately to the operator via the master unit.

Kline-Schoder, Robert J.↗

Spin Start Line Effects on the J2X Gas Generator Chamber Acoustics

The J2X Gas Generator engine design has a spin start line connected near to the turbine inlet vanes. This line provides helium during engine startup to begin turbomachinery operation. The spin start line also acts as an acoustic side branch which alters the chamber's acoustic modes. The side branch effectively creates 'split modes' in the chamber longitudinal modes, in particular below the first longitudinal mode and within the frequency range associated with the injection-coupled response of the Gas Generator. Interaction between the spin start-modified chamber acoustics and the injection-driven response can create a higher system response than without the spin start attached to the chamber. This work reviews the acoustic effects of the spin start line as seen throughout the workhorse gas generator test program. A simple impedance model of the spin start line is reviewed. Tests were run with no initial spin start gas existing in the line, as well as being initially filled with nitrogen gas. Tests were also run with varying spin start line lengths from 0" to 40". Acoustic impedance changes due to different spin start gas constituents and line lengths are shown. Collected thermocouple and static pressure data in the spin start line was used to help estimate the fluid properties along the line length. The side branch impedance model was coupled to a chamber impedance model to show the effects on the overall chamber response. Predictions of the spin start acoustic behavior for helium operation are shown and compared against available data.

Kenny, R. Jeremy↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Impedance-Aware Graph Convolutional Networks for Voltage Estimation in Active Distribution Networks

Voltage estimation plays a key role in ensuring the effective control and reliability of distribution networks. However, traditional machine learning methods often fail to capture the details of the distribution network’s topology. To overcome this challenge, graph convolutional networks (GCN) have emerged as an alternative. Graph convolutional networks inherently capture the topology of the grid, utilizing correlations to achieve precise voltage estimation. Other machine learning models and conventional GCNs fail to account for the distribution line characteristics found in the real world, limiting their effectiveness. This paper proposes an advanced variant of GCN called the Impedance-Aware Graph Convolutional Network (IA-GCN). The IA-GCN layer incorporates the magnitude of the impedance into the graph convolution mechanism, allowing it to capture topological nuances and provide valuable insights into node interrelationships by considering impedance as an intrinsic dimension. The performance of the IA-GCN layer is then compared with that of GCN and GraphSAGE layers through a surrogate model for voltage estimation. The performance analysis demonstrates that IA-GCN outperforms GCN by reducing the MAE by 87.55% and improving the R-squared value by 98%.

Ravi, Abhijith↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sunspot models with Alfven wave emission

Sunspot models have been computed on the assumption that the missing flux is transported by undissipated Alfven waves. In order to estimate the flux of these waves, we propose an extension of Opik's cellular model of convection to include the effects of a vertical magnetic field on horizontal gas flow. Horizontal motions, not vertical motions, are impeded more or less severely depending on the electrical conductivity, and this reduces the convective flux. These motions, however, shake the field lines; this is assumed to be a source of Alfven waves, compensating for the reduction in the convective flux. The free parameter D/H (ratio of cell diameter to cell depth) is adjusted such that the total sum of radiative, convective, and Alfven wave fluxes remains constant at all depths and equals the undisturbed solar flux entering the spot from below. Our treatment is speculative to some extent, but it leads to a unique spot model for a given field strength.

Mullan, D. J.↗

Grid Parameters and Voltage Estimation Approach Integrating Data-Driven Converter Model

With Measurements of grid voltage and current are essential for the optimal operation of the grid protection and control (P&C) systems. Grid parameters vary through time during the faults and especially in the converter interfaced resources (CIRs) rich power grid, and thus accurate estimation is critical to avoid the mis-operation of the P&C systems. In this paper, a moving horizon estimation (MHE) as an observer is devised and applied to estimate the grid line parameters and grid voltages for protection enhancement. Due to the proprietary and confidentiality of CIRs, the proposed approach uses the black-box model to represent their dynamics. Leveraging the easily accessible measurements of output current from the black-box model of CIR and voltage at the point of common coupling, the proposed method estimates the grid impedance and grid voltage during normal and faulty operating conditions. The performance shows that the optimization-based observer was able to closely observe the accurate states and parameters, which can be utilized by the P&C systems.

Subedi, Sunil↗

Slot antenna SIS mixers for submillimeter wavelengths

We are developing improved versions of a slot antenna SIS mixer which we have previously described. The initial work demonstrated a double sideband noise temperature of 420 K for a 500 GHz quasi-optical SIS mixer employing a twin-slot antenna on a quartz dielectric substrate. A quartz hyperhemispherical lens is used to focus the incoming radiation onto the twin-slot antenna. The advantages of a twin-slot antenna include a low impedance (35 omega) and a clean, symmetric beam pattern into the dielectric with a 70 percent efficiency. In our original mixer, the radiation was coupled from the two slot antennas onto superconducting microstrip lines which fed the SIS junction. By performing an impedance transformation using tapered lines and by feeding the radiation from the two slots to the junction in parallel, the effective (real) impedance seen by the junction was reduced to just 4 omega. This very low impedance allowed a junction area of 2.3 sq micron to be used at 500 GHz, which was manufactured using optical lithography. However, no attempt was made to tune out the junction capacitance. We estimate that this capacitance reduces the impedance coupling efficiency to eta(sub Z) approx. equals 0.23, for our junction with omega R(sub N) C = 5.3 at 500 GHz. The recent development of techniques using electron-beam lithography to manufacture junctions with very small areas (approx. equals 0.1 sq microns) now allows considerably more flexibility in the design of SIS mixer circuits. We have redesigned the slot-antenna mixer to take advantage of this possibility. In particular, we have included a novel circuit which allows the junction capacitance to be tune out over a broad bandwidth. For instance, mixers designed for 800 GHz using NbN/MgO/NbN junctions with realistic parameters achieve a 3 dB impedance bandwidth of nearly 400 GHz. Furthermore, our circuit uses only short lengths of microstrip and should be less sensitive to RF losses than other designs. The improved impedance match should give a large reduction in noise temperature as compared to our previous mixer. The new devices are currently under fabrication. Further details of the design and any available experimental results are discussed.

Zmuidzinas, Jonas↗

Quantifying the Relationship Between Microstructure and Performance in Gadolinium-Doped Ceria Infiltrated Ni/YSZ Symmetric Cells

Infiltration of mixed ionic/electronic conducting (MIEC) nanocatalysts into the anodes of solid oxide fuel cells (SOFCs) allow the hydrogen oxidation reaction (HOR) to occur at double-phase boundaries (DPBs), rather than being confined only to the triple phase boundaries (TPBs). In this research, we use a combination of cross-sectional scanning electron microscopy (SEM), three-dimensional (3-D) reconstruction, and electrochemical methods to characterize both baseline and gadolinium-doped ceria (GDC)-infiltrated symmetric cells, with the goal of establishing a comparison between the density of electrochemically active sites in uninfiltrated and GDC-infiltrated cells. Here, electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT) analysis showed GDC infiltration decreased the overall polarization of the anode by a factor of 8.78 X, and decreased the resistance associated with the reactions at the TPBs/DPBs by a factor of over 21 X. By quantifying expected GDC deposition morphology in the Ni/YSZ anode it is estimated that reactions occur in the baseline cell up to 84 nm from the active TPB lines.

36 MATERIALS SCIENCE↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Detection of a Cobalt-Containing Interphase at the Li 6 PS 5 Cl-NMC111 Interface by In Situ μ XANES and EIS

Sulfide electrolyte all-solid-state lithium batteries (ASLBs) with uncoated Li-Ni x Mn y Co 1–x–y O 2 (NMC) cathodes suffer from a large capacity loss during initial cycling and an increase in cell impedance. Decomposition reactions are known to occur at the Li 6 PS 5 Cl-NMC111 interface due to incompatibility between the two materials. If a stabilizing coating is applied to the NMC, it delivers full capacity during initial charge. However, the loss in capacity during discharge still occurs. The interface was studied by μ XANES and through EIS analysis. A chemically-formed interphase was detected by μ XANES, evident from reduction of Co at an uncoated NMC particle surface. This interphase was produced by decomposition at rest. To study the effect of the interphase on electrochemically active surface area, piecewise in situ EIS was performed and the data was modeled using a transmission line model (TLM). The charge transfer resistance R CT was used to estimate the volume specific active surface area (a act ). The median value for a act was 296 cm –1 , a factor of 7.5 lower than the theoretical value of 2216 cm –1 . This provided evidence of a lower electrochemically active surface area in the ASLB.

36 MATERIALS SCIENCE↗

Particle Acceleration in Dissipative Pulsar Magnetospheres

Pulsar magnetospheres represent unipolar inductor-type electrical circuits at which an EM potential across the polar cap (due to the rotation of their magnetic field) drives currents that run in and out of the polar cap and close at infinity. An estimate ofthe magnitude of this current can be obtained by dividing the potential induced across the polar cap V approx = B(sub O) R(sub O)(Omega R(sub O)/c)(exp 2) by the impedance of free space Z approx eq 4 pi/c; the resulting polar cap current density is close to $n {GJ} c$ where $n_{GJ}$ is the Goldreich-Julian (GJ) charge density. This argument suggests that even at current densities close to the GJ one, pulsar magnetospheres have a significant component of electric field $E_{parallel}$, parallel to the magnetic field, a condition necessary for particle acceleration and the production of radiation. We present the magnetic and electric field structures as well as the currents, charge densities, spin down rates and potential drops along the magnetic field lines of pulsar magnetospheres which do not obey the ideal MHD condition $E cdot B = 0$. By relating the current density along the poloidal field lines to the parallel electric field via a kind of Ohm's law $J = sigma E_{parallel}$ we study the structure of these magnetospheres as a function of the conductivity $sigma$. We find that for $sigma gg OmegaS the solution tends to the (ideal) Force-Free one and to the Vacuum one for $sigma 11 OmegaS. Finally, we present dissipative magnetospheric solutions with spatially variable $sigma$ that supports various microphysical properties and are compatible with the observations.

Kazanas, Z.↗