Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multispectral linear array

The Multispectral Linear Array (MLA) is a solid-state earth imagery radiometer operating in the 'push-broom' mode and using a focal plane containing multiple spectral band linear detector arrays. The MLA sensor offers the capability for increased spatial and spectral resolution with multiple selectable bands and in-orbit operation flexibility. Both free-flyer (satellite) and Shuttle-attached instrument designs have been studied. Four Shuttle-attached MLA instrument design studies were initiated in 1982, and the concepts resulting from these studies are described.

Richard, H. L.↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

Application of linear array imaging techniques to the real-time inspection of airframe structures and substructures

Development and application of linear array imaging technologies to address specific aging-aircraft inspection issues is described. Real-time video-taped images were obtained from an unmodified commercial linear-array medical scanner of specimens constructed to simulate typical types of flaws encountered in the inspection of aircraft structures. Results suggest that information regarding the characteristics, location, and interface properties of specific types of flaws in materials and structures may be obtained from the images acquired with a linear array. Furthermore, linear array imaging may offer the advantage of being able to compare 'good' regions with 'flawed' regions simultaneously, and in real time. Real-time imaging permits the inspector to obtain image information from various views and provides the opportunity for observing the effects of introducing specific interventions. Observation of an image in real-time can offer the operator the ability to 'interact' with the inspection process, thus providing new capabilities, and perhaps, new approaches to nondestructive inspections.

Miller, James G.↗

Breadboard linear array scan imager program

The performance was evaluated of large scale integration photodiode arrays in a linear array scan imaging system breadboard for application to multispectral remote sensing of the earth's resources. Objectives, approach, implementation, and test results of the program are presented.

Source record↗

Optimizing a Linear Array of Radiating Elements

EOPS empirically optimizes linear array of radiating elements. Program directly addresses problem of minimizing maximum side-lobe level of fixed length, linear arrays of radiating elements under realistic "on-the-vehicle" conditions. Used for both electromagnetic and acoustic arrays.

Blank, S. J.↗

Fan beam generated by a linear-array fed parabolic reflector

The theoretical background and the results of computer simulations and experimental studies for a parabolic reflector fed by a linear array are detailed. The concept of using a parabolic reflector antenna fed by a small linear array to generate fan-beam patterns is validated. Large angle scan along the broad-beam direction of the fan beam can be achieved by offsetting the linear array laterally. It is both empirically and numerically demonstrated that the array feed must be displaced in the reflector's axial direction to an optimum location from the focal plane in order to achieve the best antenna gain performance. As a result, the linear-array-fed parabolic reflector can be used in place of a long planar array in a multifunctional reflector antenna system.

Huang, John↗

Multispectral Linear Array detector technology

The Multispectral Linear Array (MLA) program sponsored by NASA has the aim to extend space-based remote sensor capabilities. The technology development effort involves the realization of very large, all-solid-state, pushbroom focal planes. The pushbroom, staring focal planes will contain thousands of detectors with the objective to provide two orders of magnitude improvement in detector dwell time compared to present Landsat mechanically scanned systems. Attenton is given to visible and near-infrared sensor development, the shortwave infrared sensor, aspects of filter technology development, the packaging concept, and questions of system performance. First-sample, four-band interference filters have been fabricated successfully, and a hybrid packaging technology is being developed.

Tower, J. R.↗

Airborne multispectral linear array instruments at Goddard Space Flight Center

The fabrication of airborne instruments is contributing to the development of multispectral linear array technology at NASA's Goddard Space Flight Center. The linear array pushbroom radiometer (LAPR-I), was built to demonstrate capabilities for acquiring digital image data using linear arrays. The LAPR-I employed three arrays of 512 silicon photodiodes each to simultaneously acquire three channels of data for spectral bands within the visible and near-infrared portions of the spectrum. A second instrument, LAPR-II, uses four arrays each consisting of 512 silicon detectors. A filter wheel containing six spectral filters is used in conjunction with each array to allow filter changes in flight. This capability will facilitate studies into the utility of various bands within the visible and near infrared portions of the spectrum. The LAPR-II's aircraft mounting will allow off-nadir pointing (plus-or-minus 50 deg fore-and-aft and side-to-side) which will enable investigations of the radiometric and geometric effects of off-nadir viewing. A short wave infrared radiometer is also described.

Irons, J. R.↗

High-resolution 3D microwave imaging using an optically tracked linear array

Active three-dimensional microwave or millimeter-wave imaging is typically performed using a linear array that is mechanically scanned over a uniform planar or cylindrical aperture. However, an image can also be formed with a linear array that is scanned over a non-uniform irregular aperture. This requires that the precise position of the array be known for each radar sample. This paper explores high-resolution 3D microwave imaging of stationary targets using an optically tracked manually scanned linear array. The image reconstruction techniques necessary to account for a non-uniform irregular aperture are also developed.

Clark, Richard T.↗

Nuclear resonant scattering measurements on {sup 57}Fe by multichannel scaling with a 64-pixel silicon avalanche photodiode linear-array detector

We developed a silicon avalanche photodiode (Si-APD) linear-array detector for use in nuclear resonant scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and depletion depth of 10 μm. An ultrafast frontend circuit allows the X-ray detector to obtain a high output rate of >10{sup 7} cps per pixel. High-performance integrated circuits achieve multichannel scaling over 1024 continuous time bins with a 1 ns resolution for each pixel without dead time. The multichannel scaling method enabled us to record a time spectrum of the 14.4 keV nuclear radiation at each pixel with a time resolution of 1.4 ns (FWHM). This method was successfully applied to nuclear forward scattering and nuclear small-angle scattering on {sup 57}Fe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction Techniques for Sparse Multistatic Linear Array Microwave Imaging

Sequentially-switched linear arrays are an enabling technology for a number of near-field microwave imaging applications. Electronically sequencing along the array axis followed by mechanical scanning along an orthogonal axis allows dense sampling of a two-dimensional aperture in near real-time. In this paper, a sparse multi-static array technique will be described along with associated Fourier-Transform-based and back-projection-based image reconstruction algorithms. Simulated and measured imaging results are presented that show the effectiveness of the sparse array technique along with the merits and weaknesses of each image reconstruction approach.

concealed-weapon detection↗

Two complimentary methods for aligning linear arrays

Two approaches are presented for implementing a simple method for aligning the object and image planes of linear arrays of elemental detectors. Both variants begin by firing a laser beam into cubic beamsplitters which change the direction of the resulting parallel beams to one perpendicular to the array. A neutral density filter is located along the beam path and an optical microscope is located beyond the exit plane of the beamsplitters. In the first variant, the beam is tuned to the spectral sensitivity of the elements. In the second version, a lens and a microscope are situated outside the exit plane of the beamsplitters, and spectral tuning is unnecessary. Subsequent rotations of the array are shown to reveal the coincidence or lack of coincidence of the image plane and the linear array.

Finkel, Mitchell W.↗

Multiple-angle observations of reflectance anisotropy from an airborne linear array sensor

An airborne pointable imaging multispectral linear array sensor has been developed for the multidirectional observation of surface reflectance anisotropy. The sensor design permits observations up to 45 deg off-nadir in three spectral bands (green, red, and near-infrared). Calibration permits the conversion of sensor data to radiance units with an absolute uncertainty of 6 percent. Observations of five field plots from seven view directions are discussed. Calibration and atmospheric corrections are used to derive hemispherical-directional reflectance factors. A three-term reflectance model is fit to the reflectance factors for each plot to represent the continuous distribution of reflectance factors with view direction. The reflectance model is integrated over all view directions to calculate bihemispherical reflectance factors. The calculated bihemispherical factors differed by 1 to 25 percent from values based on an assumption of isotropic reflectance depending on spectral band and field plot. These calculations demonstrate the technologic and scientific capabilities required for the remote characterization of surface reflectance anisotropy. Remote multidirectional observations are both feasible and needed to fully evaluate land reflectance characteristics.

Irons, James R.↗

Linear Array Photodiode and Data Acquisition System Development for Multi-Point Line FLDI Measurements

The continuous development and advancement of multi-point line focused laser differential interferometry (FLDI) instruments requires larger numbers of acquisition channels to make more finely spatially resolved measurements of high-frequency flow fluctuations. No current off-the-shelf system exists for these line FLDI measurements, and so a single unified system consisting of a linear array photodiode, required electronics, and a data acquisition system has been developed to enhance the measurement resolution, both spatially and temporally. A printed circuit board was developed on which the linear array photodiode is mounted for inclusion into an existing FLDI system, and amplifier breakout boards incorporate electronics to condition the signal for the data acquisition system while retaining the necessary high frequency response. The data acquisition system uses a National Instruments chassis and multiple oscilloscope modules, with a specially-designed LabVIEW user interface for laboratory and wind tunnel setup, calibration, and testing. Details regarding the development of the linear array photodiode system and the data acquisition system are provided, and systematic testing of all components is presented, culminating in a test of the system integrated into an existing line FLDI system for measurements of a turbulent jet.

Joshua M Weisberger↗

Multiband selection with linear array detectors

Several techniques that can be used in an earth-imaging system to separate the linear image formed after the collecting optics into the desired spectral band are examined. The advantages and disadvantages of the Multispectral Linear Array (MLA) multiple optics, the MLA adjacent arrays, the imaging spectrometer, and the MLA beam splitter are discussed. The beam-splitter design approach utilizes, in addition to relatively broad spectral region separation, a movable Multiband Selection Device (MSD), placed between the exit ports of the beam splitter and a linear array detector, permitting many bands to be selected. The successful development and test of the MSD is described. The device demonstrated the capacity to provide a wide field of view, visible-to-near IR/short-wave IR and thermal IR capability, and a multiplicity of spectral bands and polarization measuring means, as well as a reasonable size and weight at minimal cost and risk compared to a spectrometer design approach.

Richard, H. L.↗