Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear ultrasound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Proceedings of the Second Annual Symposium for Nondestructive Evaluation of Bond Strength

Ultrasonics, microwaves, optically stimulated electron emission (OSEE), and computational chemistry approaches have shown relevance to bond strength determination. Nonlinear ultrasonic nondestructive evaluation methods, however, have shown the most effectiveness over other methods on adhesive bond analysis. Correlation to changes in higher order material properties due to microstructural changes using nonlinear ultrasonics has been shown related to bond strength. Nonlinear ultrasonic energy is an order of magnitude more sensitive than linear ultrasound to these material parameter changes and to acoustic velocity changes caused by the acoustoelastic effect when a bond is prestressed. Signal correlations between non-linear ultrasonic measurements and initialization of bond failures have been measured. This paper reviews bond strength research efforts presented by university and industry experts at the Second Annual Symposium for Nondestructive Evaluation of Bond Strength organized by the NDE Sciences Branch at NASA Langley in November 1998.

Roberts, Mark J.↗

Proceedings of the First Annual Symposium for Nondestructive Evaluation of Bond Strength

Quantitative adhesive bond strength measurement has been an issue for over thirty years. Utilization of nonlinear ultrasonic nondestructive evaluation methods has shown more effectiveness than linear methods on adhesive bond analysis, resulting in an increased sensitivity to changes in bondline conditions. Correlation to changes in higher order material properties due to microstructural changes using nonlinear ultrasonics has been shown and could relate to bond strength. Nonlinear ultrasonic energy is an order of magnitude more sensitive than linear ultrasound to these material parameter changes and to acoustic velocity changes caused by the acoustoelastic effect when a bond is prestressed. This increased sensitivity will assist in getting closer to quantitative measurement of adhesive bond strength. Signal correlations between non-linear ultrasonic measurements and initialization of bond failures have been successfully measured. This paper reviews nonlinear bond strength research efforts presented by university and industry experts at the First Annual Symposium for Nondestructive Evaluation of Bond Strength organized by the NDE Sciences Branch at NASA Langley in November 1997.

Roberts, Mark J.↗

Plantar soft tissue thickness during ground contact in walking

A technique is introduced for the measurement of plantar soft tissue thickness during barefoot walking. Subjects stepped into an adjustable Plexiglas frame which ensured that the required bony landmarks were appropriately positioned relative to a linear ultrasound probe connected to a conventional 7.5 MHz ultrasound scanner. Clear images of the metatarsal condyles or other foot bones were obtained throughout ground contact. Subsequent analysis of the video taped images using a motion analysis system allowed the tissue displacement to be calculated as a function of time. The tissue underneath the second metatarsal head was shown to undergo an average maximum compression of 45.7% during the late stages of ground contact during first step gait in a group of five normal subjects with a mean unloaded tissue thickness of 15.2 mm. The technique has a number of applications, including use in the validation of deformation predicted by finite element models of the soft tissue of the foot, and the study of alterations in the cushioning properties of the heel by devices which constrain the displacement of the heel pad.

Non-NASA Center↗

Advanced Ultrasonic Diagnosis of Extremity Trauma: The Faster Exam

Ultrasound is of prO)len accuracy in abdominal and thoracic trauma and may be useful to diagnose extremity injury in situations where radiography is not available such as military and space applications. We prospectively evaluated the utility of extremity , ultrasound performed by trained, non-physician personnel in patients with extremity trauma, to simulate remote aerospace or military applications . Methods: Patients with extremity trauma were identified by history, physical examination, and radiographic studies. Ultrasound examination was performed bilaterally by nonphysician personnel with a portable ultrasound device using a 10-5 MHz linear probe, Images were video-recorded for later analysis against radiography by Fisher's exact test. The average time of examination was 4 minutes. Ultrasound accurately diagnosed extremity, injury in 94% of patients with no false positive exams; accuracy was greater in mid-shaft locations and least in the metacarpa/metatarsals. Soft tissue/tendon injury was readily visualized . Extremity ultrasound can be performed quickly and accurately by nonphysician personnel with excellent accuracy. Blinded verification of the utility of ultrasound in patients with extremity injury should be done to determine if Extremity and Respiratory evaluation should be added to the FAST examination (the FASTER exam) and verify the technique in remote locations such as military and aerospace applications.

Dulchavsky, S. A.↗

Role for Lower Extremity Interstitial Fluid Volume Changes in the Development of Orthostasis after Simulated Microgravity

Reentry orthostasis after exposure to the conditions of spaceflight is a persistent problem among astronauts. In a previous study, a computer model systems analysis was used to examine the physiologic mechanisms involved in this phenomenon. In this analysis, it was determined that an augmented capacitance of lower extremity veins due to a fluid volume contracture of the surrounding interstitial spaces during spaceflight results in an increase in sequestered blood volume upon standing and appears to be the initiating mechanism responsible for reentry orthostasis. In this study, we attempt to validate the central premise of this hypothesis using a ground-based spaceflight analog. 10 healthy subjects were placed at bed rest in a 6 head down tilt position for 60 days of bed rest. The impact of adaptations in interstitial fluid volume and venous capacitance in the lower extremities were then observed during a standard tilt test protocol performed before and after the confinement period. The interstitial thickness superficial to the calcaneous immediately below the lateral malleolus was measured using ultrasound with a 17-5 MHz linear array transducer. Measurements of the changes in anterior tibial vein diameter during tilt were obtained by similar methods. The measurements were taken while the subjects were supine and then during upright tilt (80') for thirty minutes, or until the subject had signs of presyncope. Additional measurements of the superficial left tibia interstitial thickness and stroke volume by standard echocardiographic methods were also recorded. In addition, calf compliance was measured over a pressure range of 10-60 mmHg, using plethysmography, in a subset of these subjects (n = 5). There was a average of 6% diminution in the size of the lower extremity interstitial space as compared to measurements acquired prior to bed rest. This contracture of the interstitial space coincided with a subsequent relative increase in the percentage change in tibial vein diameter and stroke volume upon tilting in contrast to the observations made before bed rest (54 vs 23% respectively). Compliance in the calf increased by an average of 36% by day 27 of bedrest. A systems analysis using a computer model of cardiovascular physiology suggests that microgravity induced interstitial volume depletion results in an accentuation of venous blood volume sequestration and is the initiating event in reentry orthostasis. This hypothesis was tested in volunteer subjects using a ground-based spaceflight analog model that simulated the body fluid redistribution induced by microgravity exposure. Measurements of changes in the interstitial spaces and observed responses of the anterior tibial vein with tilt, together with the increase in calf compliance, were consistent with our proposed mechanism for the initiation of postflight orthostasis often seen in astronauts.

Platts, Steven H.↗

Non-Invasive Measurement of Intracranial Pressure Pulsation using Ultrasound

Exposure to microgravity causes a cephalad fluid shift which may elevate intracranial pressure (ICP). Elevation in ICP may affect cerebral hemodynamics in astronauts during space flight. ICP is, however, a difficult parameter to measure due to the invasiveness of currently available techniques. We already reported our development of a non-invasive ultrasound device for measurement of ICP. We recently modified the device so that we might reproducibly estimate ICP changes in association with cardiac cycles. In the first experiment, we measured changes in cranial distance with the ultrasound device in cadavera while changing ICP by infusing saline into the lateral ventricle. In the second experiment, we measured changes in cranial distance in five healthy volunteers while placing them in 60 deg, 30 deg head-up tilt, supine, and 10 deg head-down tilt position. In the cadaver study, fast Fourier transformation revealed that cranial pulsation is clearly associated with ICP pulsation. The ratio of cranial distance and ICP pulsation is 1.3microns/mmHg. In the tilting study, the magnitudes of cranial pulsation are linearly correlated to tilt angles (r=0.87). The ultrasound device has sufficient sensitivity to detect cranial pulsation in association with cardiac cycles. By analyzing the magnitude of cranial pulsation, estimates of ICP during space flight are possible.

Ueno, Toshiaki↗

Carotid Intima Media Thickness in the Astronaut Corps: Association to Spacecraft

Background: Carotid Intima Media Thickness (CIMT) has been demonstrated to be predictive of future cardiovascular events. Within various populations, radiation exposure, stress, and physical confinement have all been linked to an increased CIMT. Recent research discovered CIMT was significantly increased in ten long duration astronauts from pre-flight to four days post flight. The relationship between spaceflight and CIMT is not understood and trends in CIMT within the larger astronaut population are unknown. Methods: In 2010, CIMT was offered as part of the astronaut annual exam at the JSC Flight Medicine Clinic using a standardized CIMT screening protocol and professional sonographers. Between 2010 and 2016, CIMT measurements were collected on 213 NASA astronauts and payload specialists. The values used in this retrospective chart review are the mean of the CIMT from the right and left. Spaceflight exposure was categorized based on the total number of days spent in space at the time of the ground-based ultrasound (0, 1-29, 30-100, 101-200, ≥200). Linear regression with generalized estimating equations were used to estimate the association between spaceflight exposures and CIMT. Results: 530 studies were completed among 213 astronauts with a mean of 2.5 studies (range 1-6) per astronaut over the six year period. As in other populations, CIMT was significantly associated with age; however, gender was not. While there was no significant direct correlation between total spaceflight exposure and CIMT found, astronauts with 30-100 spaceflight days and astronauts with greater than 100 spaceflight days had significantly increased CIMT over astronauts who had never flown (p=0.002 and p=<0.0001 respectively) after adjustment for age. Conclusion: Further work is needed to fully understand CIMT and its association to spaceflight. Current occupational surveillance activities are under way to study CIMT values in conjunction with other cardiovascular risk factors among astronauts as compared to the general population.

Suffredini, John↗

Computational Modeling of Micro-Crack Induced Attenuation in CFRP Composites

A computational study is performed to determine the contribution to ultrasound attenuation in carbon fiber reinforced polymer composite laminates of linear elastic scattering by matrix micro-cracking. Multiple scattering approximations are benchmarked against exact computational approaches. Results support linear scattering as the source of observed increased attenuation in the presence of micro-cracking.

Roberts, R. A.↗

Ultrasonic Nondestructive Characterization of Adhesive Bonds

Qualitative measurements of adhesion or binding forces can be accomplished, for example, by using the reflection coefficient of an ultrasound or by using thermal waves (Light and Kwun, 1989, Achenbach and Parikh, 1991, and Bostrom and wickham, 1991). However, a quantitative determination of binding forces is rather difficult. It has been observed that higher harmonics of the fundamental frequency are generated when an ultrasound passes through a nonlinear material. It seems that such non-linearity can be effectively used to characterize the bond strength. Several theories have been developed to model this nonlinear effect (Adler and Nagy, 1991; Achenbach and Parikh, 1991; Parikh and Achenbach, 1992; and Hirose and Kitahara, 1992; Anastasi and Roberts, 1992). Based on a microscopic description of the nonlinear interface binding force, a quantitative method was presented by Pangraz and Arnold (1994). Recently, Tang, Cheng and Achenbach (1997) made a comparison between the experimental and simulated results based on this theoretical model. A water immersion mode-converted shear wave through-transmission setup was used by Berndt and Green (1997) to analyze the nonlinear acoustic behavior of the adhesive bond. In this project, the nonlinear responses of an adhesive joint was investigated through transmission tests of ultrasonic wave and analyzed by the finite element simulations. The higher order harmonics were obtained in the tests. It is found that the amplitude of higher harmonics increases as the aging increases, especially the 3dorder harmonics. Results from the numerical simulation show that the material nonlinearity does indeed generate higher order harmonics. In particular, the elastic-perfect plastic behavior generates significant 3rd and 5th order harmonics.

Qu, Jianmin↗

Pulse-Echo Phased Array Ultrasonic Inspection of Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS)

A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X-Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading. Keywords: Phased Array, Ultrasonics, Composites, Out-of-Autoclave

Phased array↗

TPSAS-NF1676L-11096-DND

A PRSEUS test article was subjected to controlled impact on the skin face followed by static and cyclic axial compressions. Phased array ultrasonic inspection was conducted before impact, and after each of the test conditions. A linear phased array probe with a manual X-Y scanner was used for interrogation. Ultrasound showed a delamination between the skin and stringer flange adjacent to the impact. As designed, the stitching in the flange arrested the lateral flaw formation. Subsequent ultrasonic data showed no delamination growth due to continued loading

Phased array↗

Stability and Heat Transfer Characteristics of Condensing Films

The overall objective of this research is to investigate the fundamental physics of film condensation in reduced gravity. The condensation of vapor on a cool surface is important in many engineering problems,including spacecraft thermal control and also the behavior of condensate films that may form on the interior surfaces of spacecraft. To examine the effects of body force on condensing films, two different geometries have been tested in the laboratory: (1) a stabilizing gravitational body force (+1g, or condensing surface facing 'upwards') and (2) de-stabilizing gravitational body force (-1g, or 'downwards'). For each geometry, different fluid configurations are employed to help isolate the fluid mechanical and thermal mechanisms operative in condensing films. The fluid configurations are (a) a condensing film, and (b) a non-condensing film with film growth by mass addition by through the plate surface. Condensation experiments are conducted in a test cell containing a cooled copper or brass plate with an exposed diameter of 12.7 cm. The metal surface is polished to allow for double-pass shadowgraph imaging, and the test surface is instrumented with imbedded heat transfer gauges and thermocouples. Representative shadowgraph images of a condensing, unstable (-1g) n-pentane film are shown. The interfacial disturbances associated with the de-stabilizing body force leading to droplet formation and break-off can be clearly seen. The heat transfer coefficient associated with the condensing film is shown. The heat transfer coefficient is seen to initially decrease, consistent with the increased thermal resistance due to layer growth. For sufficiently long time, a steady value of heat transfer is observed, accompanied by continuous droplet formation and break-off. The non-condensing cell consists of a stack of thin stainless steel disks 10 cm in diameter mounted in a brass enclosure. The disks are perforated with a regular pattern of 361 holes each 0.25 mm in diameter. Non-condensing experiments in -1g have employed 50 cSt and 125 cSt silicone oil pumped through the perforated disks at a specified rate by a syringe micropump. The time to droplet break-off and the disturbance wavelengths appear to decrease with increasing pumping rate. The ability to reliably perform multi-point, ultrasonic measurements of the film thickness has been demonstrated. A linear array of eight transducers of 6 mm diameter (with a beam footprint of comparable size) are pulsed with a square-wave signal at a frequency of 5 MHz and a pulse duration of approximately 0.3 s. For thin films (60 m to 2-3 mm in thickness) the layer thickness is determined by frequency analysis, where the received ultrasound pulse is Fourier transformed and the spacing between the peaks in the frequency spectrum is analyzed. For thicker layers (up to at least 1 cm in thickness), time-domain analysis is performed of the received ultrasound pulses to generate directly the layer thickness. A time-trace of the film thickness at a point using a single transducer in the linear array is shown for the case of an unstable (-1g) n-pentane film. The oscillations in film thickness are evidently due to the passage and/or shedding of droplets from the cooled plate surface. The entire transducer array was used to measure the changes in film thickness resulting from the passage of gravity waves generated either by an oscillating wall or the impact of a single droplet on the free surface of a film. The enclosure in both cases was 14 cm square and the transducer spacing was 12 mm. Best results were obtained using as test fluid a mixture of 50% glycerol and 50% water with a fluid layer thickness of 3-5 mm. In both cases the measured wavelengths and wave propagation speeds using the ultrasound technique compared reasonably well with those observed by optical imaging. Additional information can be found in the original extended abstract.

Hermanson, J. C.↗

Facial Soft Tissue Measurement in Microgravity-induces Fluid Shifts

Fluid shifts are a well‐known phenomenon in microgravity, and one result is facial edema. Objective measurement of tissue thickness in a standardized location could provide a correlate with the severity of the fluid shift. Previous studies of forehead tissue thickness (TTf) suggest that when exposed to environments that cause fluid shifts, including hypergravity, head‐down tilt, and high‐altitude/lowpressure, TTf changes in a consistent and measurable fashion. However, the technique in past studies is not well described or standardized. The International Space Station (ISS) houses an ultrasound (US) system capable of accurate sub‐millimeter measurements of TTf. We undertook to measure TTf during long‐duration space flight using a new accurate, repeatable and transferable technique. Methods: In‐flight and post‐flight B‐mode ultrasound images of a single astronaut's facial soft tissues were obtained using a Vivid‐q US system with a 12L‐RS high‐frequency linear array probe (General Electric, USA). Strictly mid‐sagittal images were obtained involving the lower frontal bone, the nasofrontal angle, and the osseo‐cartilaginous junction below. Single images were chosen for comparison that contained identical views of the bony landmarks and identical acoustical interface between the probe and skin. Using Gingko CADx DICOM viewing software, soft tissue thickness was measured at a right angle to the most prominent point of the inferior frontal bone to the epidermis. Four independent thickness measurements were made. Conclusions: Forehead tissue thickness measurement by ultrasound in microgravity is feasible, and our data suggest a decrease in tissue thickness upon return from microgravity environment, which is likely related to the cessation of fluid shifts. Further study is warranted to standardize the technique with regard to the individual variability of the local anatomy in this area.

Marshburn, Thomas↗

Physical interpretation and development of ultrasonic nondestructive evaluation techniques applied to the quantitative characterization of textile composite materials

In this Progress Report, we describe our current research activities concerning the development and implementation of advanced ultrasonic nondestructive evaluation methods applied to the characterization of stitched composite materials and bonded aluminum plate specimens. One purpose of this investigation is to identify and characterize specific features of polar backscatter interrogation which enhance the ability of ultrasound to detect flaws in a stitched composite laminate. Another focus is to explore the feasibility of implementing medical linear array imaging technology as a viable ultrasonic-based nondestructive evaluation method to inspect and characterize bonded aluminum lap joints. As an approach to implementing quantitative ultrasonic inspection methods to both of these materials, we focus on the physics that underlies the detection of flaws in such materials.

Miller, James G.↗

Application of Laser Based Ultrasound for NDE of Damage in Thick Stitched Composites

As design engineers implement new composite systems such as thick, load bearing composite structures, they must have certifiable confidence in structure s durability and worthiness. This confidence builds from understanding the structural response and failure characteristics of simple components loaded in testing machines to tests on full scale sections. Nondestructive evaluation is an important element which can provide quantitative information on the damage initiation, propagation, and final failure modes for the composite structural components. Although ultrasound is generally accepted as a test method, the use of conventional ultrasound for in-situ monitoring of damage during tests of large structures is not practical. The use of lasers to both generate and detect ultrasound extends the application of ultrasound to in- situ sensing of damage in a deformed structure remotely and in a non-contact manner. The goal of the present research is to utilize this technology to monitor damage progression during testing. The present paper describes the application of laser based ultrasound to quantify damage in thick stitched composite structural elements to demonstrate the method. This method involves using a Q-switched laser to generate a rapid, local linear thermal strain on the surface of the structure. This local strain causes the generation of ultrasonic waves into the material. A second laser used with a Fabry-Perot interferometer detects the surface deflections. The use of fiber optics provides for eye safety and a convenient method of delivering the laser over long distances to the specimens. The material for these structural elements is composed of several stacks of composite material assembled together by stitching through the laminate thickness that ranging from 0.5 to 0.8 inches. The specimens used for these nondestructive evaluation studies had either impact damage or skin/stiffener interlaminar failure. Although little or no visible surface damage existed, internal damage was detected by laser based ultrasound.

Anastasi, Robert F.↗

Characterization of the Nonlinear Elastic Properties of Graphite/Epoxy Composites Using Ultrasound

The normalized change in ultrasonic "natural" velocity as a function of stress and temperature was measured in a unidirectional laminate of T300/5208 graphite/epoxy composite using a pulsed phase locked loop ultrasonic interferometer. These measurements were used together with the linear (second order) elastic moduli to calculate some of the nonlinear (third order) moduli of this material.

Prosser, William H.↗

A new ultrasonic imaging system using time delay spectrometry

A new method of forming a visual image by ultrasound is described. A shadowgraphic transmission image similar to an X-ray radiograph is produced by the application of a technique known as Time Delay Spectrometry. The system uses a repetitive frequency sweep with a linear relationship between frequency and time and the transmitting and receiving crystal are scanned in raster fashion about the subject. By electronic processing, an image may be built up which represents the energy transmitted through the specimen with a given time delay. An intensity modulated picture encompassing the full shades-of-gray capability of the recording system can be produced. A second type of image showing transmission time through the specimen may also be formed. Brightness changes in the displayed image in this case correspond to changes in the ultrasonic transmission time through the specimen.

Heyser, R. C.↗

Ultrasonic nondestructive materials characterization

A brief review of ultrasonic wave propagation in solid materials is presented with consideration of the altered behavior in anisotropic and nonlinear elastic materials in comparison with isotropic and linear elastic materials. Some experimental results are described in which ultrasonic velocity and attenuation measurements give insight into materials microstructure and associated mechanical properties. Recent developments with laser beam non-contact generation and detection of ultrasound are presented. The results of several years of experimental measurements using high-power ultrasound are discussed, which provide substantial evidence of the inability of presently accepted theories to fully explain the interaction of ultrasound with solid materials. Finally, a special synchrotron X-ray topographic system is described which affords the possibility of observing direct interaction of ultrasonic waves with the microstructural features of real crystalline solid materials for the first time.

Green, R. E., Jr.↗