Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Unified Analytical Method Greenness Score ( uAMGS ) Quantifies How Microscopic Imaging Is Greener Than Conventional Liquid Chromatography

Green chemistry is a set of principles for assessing, developing, and implementing methods that are safer, more efficient, and less detrimental to the environment. The analytical method greenness score (AMGS) is one of many metrics that attempt to evaluate traditional liquid chromatography (LC) based on the energy consumption of the instrument and the safety, health risks, and environmental impact of the solvents employed. Unfortunately, in practice, the AMGS is primarily focused on traditional separation methods in the pharmaceutical industry and is not amenable to cutting-edge separation science, including miniaturization. To broaden this scope, the unified Analytical Method Greenness Score (uAMGS) is presented here, which clarifies and expands on the underlying mathematics and incorporates both dimensional and uncertainty analysis, enabling its application to a broader range of analytical techniques. The uAMGS is used to compare the greenness of two distinct methods: single-molecule microscopy (SMM) and high-performance liquid chromatography (HPLC), which were used to collect equivalent data. uAMGS determines that SMM is significantly greener than HPLC due primarily to decreased solvent consumption. Overall, the uAMGS should allow chemists ranging from undergraduates to industrial PhDs to assess the greenness of a wide range of separations.

chemical separations↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Determination of 2,4-Dinitrophenol (2,4-DNP) in Simulated Radioactive Waste by High Performance Liquid Chromatography

The River Protection Project (RPP) at Hanford, Washington is evaluating an alternative treatment method for low activity tank waste (LAW) disposition. Specifically, grout solidification/immobilization for LAW needs to demonstrate adequate treatment for Land Disposal Restricted (LDR) Organic chemicals. LDR organic chemical pretreatment, such as evaporations testing and oxidation decomposition, are under assessment to reduce the LDR organic chemicals concentration in the LDR waste. 2,4-dinitrophenol was spiked into LAW simulated waste and monitored in these studies using High Performance Liquid Chromatography (HPLC). The development and implementation of this HPLC method is discussed in this presentation.

Dekarske, John R. [Savannah River National Laborat↗

Improved Characterization of Soil Organic Matter by Integrating FT-ICR MS, Liquid Chromatography Tandem Mass Spectrometry, and Molecular Networking: A Case Study of Root Litter Decay under Drought Conditions

Understanding of how soil organic matter (SOM) chemistry is altered in a changing climate has advanced considerably; however, most SOM components remain unidentified, impeding the ability to characterize a major fraction of organic matter and predict what types of molecules, and from which sources, will persist in soil. Here we present a novel approach to better characterize SOM extracts by integrating information from three types of analyses, and we deploy this method to characterize decaying root-detritus soil microcosms subjected to either drought or normal conditions. To observe broad differences in composition, we employed direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR MS). We complemented this with liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify components by library matching. Since libraries contain only a small fraction of SOM components, we also used fragment spectral cosine similarity scores to relate unknowns and library matches through molecular networks. This integrated approach allowed us to corroborate DI-FT-ICR MS molecular formulas using library matches, which included fungal metabolites and related polyphenolic compounds. We also inferred structures of unknowns from molecular networks and improved LC-MS/MS annotation rates from ~5 to 35% by considering DI-FT-ICR MS molecular formula assignments. Under drought conditions, we found greater relative amounts of lignin-like vs condensed aromatic polyphenol formulas and lower average nominal oxidation state of carbon, suggesting reduced decomposition of SOM and/or microbes under stress. Our integrated approach provides a framework for enhanced annotation of SOM components that is more comprehensive than performing individual data analyses in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel insight into the kinetics of amide bond glycolysis for nylon-6 depolymerization

Chemical recycling of nylon-6 to short-chain oligomers and monomer ε-caprolactam via catalytic glycolysis is a potential solution for plastic waste remediation. Here, in this work, the kinetics of amide bond glycolysis (with ethylene glycol) in nylon-6 and the model compound N-phenethyl-3-phenylpropanamide (M1) were evaluated at 473 K in the presence of the cyclic amidine catalyst 1,5,7-triazabicyclo[4.4.0]dec-5-ene. Rates of polymer glycolysis were determined by the time-dependent shift in molecular weight distribution, whereas rates of M1 glycolysis were determined using liquid chromatography. The similarity of the first-order rate constants for glycolysis of nylon-6 and M1 at 473 K with 0.03 M amidine catalyst (5 mol% relative to amide bonds), 1.22 × 10 −5 s −1 and 2.18 × 10 −5 s −1 , respectively, confirmed the suitability of M1 as a model compound for nylon-6 glycolysis. Similar rates of glycolysis in the presence of other cyclic amidine catalysts as well as sodium methoxide revealed little influence of base strength. Glycolysis rates were unexpectedly non-linear in catalyst loading and deactivation occurred with long reaction times, presumably by non-selective decomposition of products as detected by liquid chromatography.

Depolymerization rate and rate constant↗

Direct Synthesis of Polyester from Biomass Derived 1,6-hexanediol using a Copper-Ceria Catalyst

Biomass derived polyesters are gaining attention due to their increased mechanical and thermal properties, and also because of their biodegradability. These polyesters are typically synthesized from polycondensation reactions between diols with dicarboxylic acids using catalysts. Other methods such as alcoholysis and acidolysis of low molecular weight esters and alcoholysis of acyl chlorides are also well known. Direct conversion of diol to ester without using dicarboxylic acid is not well known, and to our knowledge has not been reported over a solid catalyst. In this study, we report a direct synthesis of polyester from 1,6-hexanediol using a copper-ceria catalyst without using a dicarboxylic acid monomer. The copper-ceria catalysts were synthesized by incipient wetness impregnation method and characterized using X-ray photoelectron spectroscopy (XPS), X-ray diffraction analysis (XRD), Brunauer-Emmett-Teller (BET), and infrared spectroscopy (IR). Our initial studies show that 1,6-hexanediol can be converted to corresponding polyester at higher temperatures under atmospheric pressures of CO2 or N2. The reaction products were analyzed using nuclear magnetic resonance spectroscopy (NMR), gel permeation chromatography (GPC), high performance liquid chromatography (HPLC), and IR spectroscopy.

Biomass derived diols↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Depth-resolved sagebrush root metabolomics, rhizosphere microbial communities, and geochemistry at the East River Watershed

This data set consists of results from soil nutrient profile, untargeted metabolomics, mass spec imaging, and amplicon sequencing. Data for soil nutrient profile includes common cations (Ca, Mg, Na, and K etc.) extracted from 3 digesting steps – ammonia acetate (for exchangeable cations), nitric acid (for acid dissolved fraction), and hydrofluoric acid/perchloric acid (HF/HClO4) for whole soil digestion. It also includes concentration of organic carbon, inorganic nitrogen (ammonia and nitrate) and phosphorus (Bray-1 P and nitric acid extract), and total nitrogen and phosphorus. Data for untargeted metabolomics includes metabolomic profile for root exudate/tissues and soil extracts from depths at surface soil to saprolite, that were measured using gas chromatography – mass spectrometry (GC-MS), and liquid chromatography – tandem mass spectrometry (LC-MS/MS). Data for mass spec imaging includes spatial distribution of metabolites that were detected and annotated with Fourier transformation ion cyclotron resonance mass spectrometer (FTICR-MS). Data for amplicon sequencing includes the base paired 16S and ITS ribosomal RNA sequences from Miseq Illumina sequencing. All samples were collected from 2 sampling campaign October 2022 and June 2023. Collectively, these datasets enable a mechanistic evaluation of how nutrient acquisition, especially nitrogen and phosphorus, differs between shallow roots operating in soil and deep roots functioning within the fractured bedrock zone. All files are provided as comma-separated values (CSV) fies (.csv) and (GZIP) file (.gz). The compressed .gz FASTQ files can be read directly in R using the dada2 package as part of the amplicon sequence analysis workflow. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. This research was performed on a project award 60563 (https://dx.doi.org/10.46936/expl.proj.2022.60563/60008727) from the Environmental Molecular Sciences Laboratory, a DOE Office of Science User Facility sponsored by the Biological and Environmental Research program under Contract No. DE-AC05-76RL01830.

EARTH SCIENCE > AGRICULTURE > SOILS > CARBON↗

Organic Acid Aerosol Measurements from the Mount Airy Site for CoURAGE

This study investigates the prevalence and distribution of organic acid aerosols in a rural environment using filter-based measurements collected in Mount Airy, Maryland, during the CoURAGE campaign from March 19th through June 12th 2025. PM2.5 filters quantify a range of organic acids commonly associated with secondary organic aerosol formation and atmospheric oxidation processes. Each filter was collected using a 15 LPM sampler and was extracted in ultrapure Millipore water (>18 MΩ), allowing water-soluble organic acids to be extracted into solution for analysis. The extracts were then examined using a Waters Acquity I-Class PLUS liquid chromatography system coupled to a Bruker Maxis-II ultra-high-resolution Q-TOF mass spectrometer with electrospray ionization, providing high-sensitivity detection and separation of target compounds. Concentrations of several key organic acids were quantified, including acetic, propionic, pyruvic, butyric, oxalic, isovaleric, valeric, malonic, maleic, succinic, glutaric, malic, adipic, and citric acids. These findings contribute to ongoing efforts to understand regional aerosol composition and their impacts on aerosol-cloud interactions.

Acetic acid↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗