Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid holdup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigation of countercurrent flow profile and liquid holdup in random packed column with local CFD data

Liquid holdup and mass transfer area are critical parameters used in packed column design and CO 2 capture efficiency prediction. Compared to experimental methods, 3D computational fluid dynamics (CFD) can provide high-resolution data for studying countercurrent flow hydrodynamics in a packed column. In this paper, a framework was established for modeling the liquid–gas countercurrent flow in a random packed column with pall rings. Besides the column-averaged information, the radial pall ring distribution, velocity, and liquid holdup profiles are obtained in the simulations. The radial two-phase velocity and liquid holdup profiles show significant fluctuations caused by the non-uniform pall ring distribution. The entrance effect and wall influence are also observed in the packed column. By using local countercurrent flow information, the packing specific area $a_p$ and liquid velocity $u_L$ range are significantly expanded for liquid holdup hL prediction. This enables us to develop the liquid holdup correlation with one packing size and six CFD runs only. The proposed power law of the liquid holdup correlation $h_L~u_L^{0.44}$ indicates the random packed column falls in a viscous to turbulent transition regime with a Reynolds Number range of [6.7–40.2]. The derived liquid holdup correlation is in good agreement with existing correlations that are developed using the column-averaged experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of random packed column parameters on the liquid holdup and interfacial area

Abstract Carbon dioxide capture via solvent absorption in packed columns has emerged as a potential technology to mitigate coal‐fired power plant CO 2 emissions. Parameters, including packing types, solvent properties, and operating conditions, could potentially affect the packed column CO 2 capture efficiency. To understand the importance of those parameters and help packed column optimization, a design of experiments (DoEs) method was proposed to generate input parameter matrix. Combined with multiphase computational fluid dynamics (CFD), the random packed column parameter influence on the liquid holdup and interfacial area can be efficiently investigated. Surrogate‐based sensitivity analysis shows that the solvent flow rate and contact angle are key factors dictating liquid holdup and interfacial area. On the other hand, solvent viscosity has a marginal impact on the interfacial area. The sensitivity scores were calculated for each input parameter to guide the selection of dimensionless numbers for the liquid holdup and interfacial area correlation development.

42 ENGINEERING↗

Countercurrent flow characteristics of next generation solvent in novel 3D printed columns for carbon capture

Solvent based absorption for carbon dioxide capture in a packed column is being considered as an efficient technology for the decarbonization process of point source. Significant efforts are underway to improve the design of packings with the cutting edge 3D printing technology for efficient carbon capture. Accordingly, multiphase flow studies were conducted to assess the performance of novel 3D printed columns with various triply periodic minimal surface (TPMS) designs. The effects of solvent properties, liquid and gas loads on the performance of TPMS columns are extensively explored. Hydrodynamics of the potential water-lean solvents (EEMPA) as well as aqueous monoethanolamine (MEA) solvent for carbon capture are evaluated and compared. The interfacial area and liquid holdup increase with increasing liquid loads (q L ) for TPMS columns. Schwarz column consistently shows the highest liquid holdup value. The EEMPA exhibits higher values for the interfacial area (10–15 %) and liquid holdup (~4 %) in comparison to the MEA. TPMS columns exhibit the intermediate value of dry pressure drop between the random and the structure packed columns. Among selected TPMS columns, the gyroid packing shows the lowest pressure drop. The gas load has marginal impact on the interfacial area at lower value while a higher gas load leads to column’s flooding. Prior to the flooding, the interfacial area in TMPS packings rises with increased gas load at a fixed liquid load except Schwarz packing where interfacial area is incentive to the gas load. Additionally, the liquid holdup and wet pressure drop rise as gas load increases in TPMS columns. Overall, Fisher Koch packing is more susceptible to flood as compared to other TPMS packings. Flow regimes: loading and flooding are also delineated in the TPMS packings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamics of countercurrent flow in an additive-manufactured column with triply periodic minimal surfaces for carbon dioxide capture

Computational investigation of the countercurrent flows in an additively manufactured (AM) column packed with triply periodic minimal surface (TPMS) is challenging. Multiphase flow simulations using the volume of fluid (VOF) method can explain the column’s hydrodynamic characteristics, including interfacial area, liquid holdup, pressure drop, flow regime, etc. The interfacial area is a key factor dictating the mass transfer via the absorption process, and thereby the overall efficiency of the column. The impacts of a solvent's physical properties, liquid and gas loads, and contact angle on the hydrodynamics are extensively explored. The solvents include traditional solvent (monoethanolamine [MEA]) used in industry as well as a water-lean solvent (EEMPA) as prospective solvents for carbon capture. As expected, interfacial area and liquid holdup increase with increasing liquid loads (q L ). The EEMPA exhibits higher values for the interfacial area and liquid holdup compared to those for the MEA. The dry and wet pressure drops per unit length in the column at different gas loads (F G ) are calculated and further compared with the empirical correlations for traditional packings. At low gas loads, i.e., in the preloading regime, the predicted values of the wet and dry pressure drops match well with the corresponding values calculated from available correlations. The gas load has a marginal impact on the interfacial area at its lower value, but the higher value of F G (>2.18 $\sqrt{Pa}$) causes flooding in the column. The effect of varying contact angles on the interfacial area and liquid holdup in the preloading regime is also studied. Both interfacial area and liquid holdup decrease with the increase in the value of the contact angle. Altogether, the effect of the contact angle on interfacial area is more pronounced than other parameters influencing the interfacial area.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiphase flow studies for microscale hydrodynamics in the structured packed column

Post combustion carbon capture by solvent absorption in a structured packed column is a promising technology for mitigating greenhouse gas emissions. Computational fluid dynamic (CFD) modelling of such a column is a challenging multiscale problem due to the range in length and time scales. The microscale hydrodynamics play a key role in the overall column efficiency with the interfacial area significantly influencing the mass transfer between the gas and liquid phases. In this context, multiphase flow simulations using the volume of fluid (VOF) method in a representative elementary unit (REU) of the packed column can provide fundamental insights into the microscale hydrodynamics, such as, interfacial area and liquid holdup. The present paper systematically examines the impact of various factors (e.g., physical properties and contact angle) on the interfacial area. The results are compared with existing correlations and a scaling analysis is also performed. The solvent physical properties are characterized by the Kapitza number (Ka), a dimensionless number that depends only on fluid properties. So that the Ka number decreases with increasing viscosity. At a fixed liquid load, the interfacial area and liquid holdup are observed to increase with decreasing Ka number. The impact of contact angle (i.e., solid surface characteristics) is effectively investigated by modifying the wall boundary conditions. The interfacial area and liquid holdup are found to decrease with increasing contact angle. Subsequently, a phenomenological correlation for interfacial area is proposed that includes the impact of these parameters. Finally, this correlation may be used to predict the interfacial area for gas-liquid flow in a structured packing for rivulet to fully wetted flow regimes.

42 ENGINEERING↗

Comparison of electrical capacitance tomography and gamma densitometer measurement in viscous oil-gas flows

Multiphase flow is a common occurrence in industries such as nuclear, process, oil and gas, food and chemical. A prior knowledge of its features and characteristics is essential in the design, control and management of such processes due to its complex nature. Electrical Capacitance Tomography (ECT) and Gamma Densitometer (Gamma) are two promising approaches for multiphase visualization and characterization in process industries. In two phase oil and gas flow, ECT and Gamma are used in multiphase flow monitoring techniques due to their inherent simplicity, robustness, and an ability to withstand wide range of operational temperatures and pressures. High viscous oil (viscosity > 100 cP) is of interest because of its huge reserves, technological advances in its production and unlike conventional oil (oil viscosity < 100 cP) and gas flows where ECT and Gamma have been previously used, high viscous oil and gas flows comes with certain associated concerns which include; increased entrainment of gas bubbles dispersed in oil, shorter and more frequent slugs as well as oil film coatings on the walls of flowing conduits. This study aims to determine the suitability of both devices in the visualization and characterization of high-viscous oil and gas flow. Static tests are performed with both devices and liquid holdup measurements are obtained. Dynamic experiments were also conducted in a 1 and 3 inch facility at Cranfield University with a range of nominal viscosities (1000, 3000 and 7500 cP). Plug, slug and wavy annular flow patterns were identified by means of Probability Mass Function and time series analysis of the data acquired from Gamma and ECT devices with high speed camera used to validate the results. Measured Liquid holdups for both devices were also compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Packed Bed Reactor Experiment (PBRE)-2: Pressure Drop Measurements in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this paper, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and compare with semi-empirical model pressure drop predictions. This work is supported by the National Aeronautics and Space Administration (NASA) under grant no. 80NSSC20K0830

Suratman Number↗

Pressure Gradient and Gas Hold-Up in Two-Phase Flows through Porous Media in Microgravity

Single and two-phase flow through porous media are encountered on ground and in space in numerous applications related to life support systems, fuel cells, chemical/materials processing and transporting nutrients to plants. These systems operate differently in the microgravity environment encountered in space travel because the density differences no longer cause the phases to separate or “drain” under the body force of gravity. In the absence of gravity, the interfacial or capillary forces play a more significant role in determining the operational variables such as phase distribution, liquid holdup, and pressure drop especially when the liquid inertia and viscous forces are at minimum. Lower liquid flow rates in air-water two-phase flows represent the case for most of the space processes that depend on two-phase flows in porous media. The Packed Bed Reactor Experiment (PBRE) was developed and flown on the International Space Station (ISS) by NASA to extend a series of fundamental studies of gas-liquid flows through porous media. The goal of the this series of flight experiments (PBRE-1 and PBRE-2) is to better understand the hydrodynamics of two phase flows in porous media in flow regimes dominated by inertia and viscous effects and understanding the role of the interfacial forces and their role in determining the flow dynamics. The flight experiments were preceded by a series of low gravity experiments performed on the low gravity aircraft. These experiments led to the development of a semi-empirical two-phase pressure drop and flow pattern transition in support of a number of reactor beds planned for water reclamation processes onboard of the international space station. The PBRE flight experiment was designed to deliver a wide range of tightly controlled gas (nitrogen) and liquid (water) flows to one of two interchangeable test sections differing only in the type of internal packing material. In this presentation, we describe the PBRE-2 experiment and present preliminary low gravity data on pressure drop and gas hold-up and compare with semi-empirical model pressure drop predictions.

Brian Motil↗

Efficient carbon capture using sub-textured polymer packing surfaces via 3D printing

Gas absorption is a common unit operation whose performance deeply relies on the gas liquid contact behavior. In this work, we report a solid polymeric surface feature containing microscale striation to improve the solid-liquid and gas-liquid contact and facilitate mass transfer. As a proof of concept, the surface feature is adopted for CO 2 capture absorber packing via 3D printing. Besides traditional embossing texture, an additional laminar striation is applied to the packing surface as a sub-texture. The packing shows notable CO 2 mass transfer increase without interfering with other key operating characteristics including pressure drop and liquid holdup. The improvement is based on the synergy of favorable wettability, thin liquid film and increased liquid mixing from rougher surface. In the demonstration test, the packing height could decrease by 33% using the advanced packing with same CO 2 removal, leading to a significant decrease in equipment size and capital expense for commercial CO 2 capture systems.

3D printing↗

Validation Framework for Post-Combustion Carbon Capture CFD Simulations

First-principles based computational fluid dynamics (CFD) simulations are proposed as a fundamental tool for investigating solvent-based CO2 absorption in packed columns, due to the ability to accurately represent the underlying non-linear multiscale dynamics. In this work, we employ such models to investigate hydrodynamics of columns with structured by assessing the key hydrodynamic metrics, such as pressure drop and liquid holdup. Our models are validated with experimental data from a specifically designed column for this line of work. The test cases of gas and liquid flowrates and operating conditions were selected through a comprehensive sequential design of experiments approach offered by the CCSI2 toolset.

Panagakos, Grigorios↗

Development of an innovative process for post-combustion CO 2 capture to produce high-value NaHCO 3 nanomaterials

An innovative post-combustion process using aqueous sodium glycinates solutions (SGS) for CO 2 capture from a split flue gas stream emitted from the 600 MWe coal power plant, used in the Wolverine Clean Energy Venture (WCEV) project, was developed in Aspen Plus v.10. The flue gas flow rate used in the process was 12.43 kg/s (at 353.15 K and 101.33 kPa) and contained 0.0023 and 13.33 mol% of SO 2 and CO 2 , respectively. The overall process includes 5 main units designed to remove all SO 2 and capture more than 90 mol% of CO 2 in the flue gas stream, while producing high-value, salable sodium bicarbonate (NaHCO 3 ) nanomaterials to offset the total process costs. The hydraulics, mass transfer characteristics, and process performance obtained using Aspen Plus were discussed. Also, the capital expenditure (CAPEX), operating expenditure (OPEX), and Levelized cost of CO 2 capture (LCOC) were calculated to assess the feasibility of this process. Further, the hydraulics in the SO 2 washing and CO 2 capture units showed a pressure drop of 12 and 1 kPa, respectively, and the behaviors of the liquid holdup and normalized packing specific wetted surface area were similar in both units. The gas-side mass transfer coefficients were orders of magnitude greater than the liquid-side mass transfer coefficients. The process was able to capture 2.352 kg/s of CO 2 and produce 4.486 kg/s of valuable NaHCO 3 nanomaterials. Also, the calculated CAPEX, OPEX, and LCOC of the process for a 30-year plant lifetime were ($\$ $4,450,552), (233.00 $\$ $/h) and (35.49 $\$ $/ton of CO 2 captured), respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Device Scale Modeling of Solvent Absorption using MFIX-TFM

Recent climate change is largely attributed to greenhouse gases (e.g., carbon dioxide, methane) and fossil fuels account for a large majority of global CO 2 emissions. That said, fossil fuels will continue to play a significant role in the generation of power for the foreseeable future. The extent to which CO 2 is emitted needs to be reduced, however, carbon capture and sequestration are also necessary actions to tackle climate change. Different approaches exist for CO 2 capture including both post-combustion and pre-combustion technologies, oxy-fuel combustion and/or chemical looping combustion. The focus of this effort is on post-combustion solvent-absorption technology. To apply CO 2 technologies at commercial scale, the availability and maturity and the potential for scalability of that technology need to be considered. Solvent absorption is a proven technology but not at the scale needed by typical power plant. The scale up and down and design of laboratory and commercial packed bed reactors depends heavily on the specific knowledge of two-phase pressure drop, liquid holdup, the wetting efficiency and mass transfer efficiency as a function of operating conditions. Simple scaling rules often fail to provide proper design. Conventional reactor design modeling approaches will generally characterize complex non-ideal flow and mixing patterns using simplified and/or mechanistic flow assumptions. While there are varying levels of complexity used within these approaches, none of these models resolve the local velocity fields. Consequently, they are unable to account for important design factors such as flow maldistribution and channeling from a fundamental perspective. Ideally design would be aided by development of predictive models based on truer representation of the physical and chemical processes that occur at different scales. Computational fluid dynamic (CFD) models are based on multidimensional flow equations with first principle foundations. CFD models can include a more accurate physical description of flow processes and be modified to include more complex behavior. Wetting performance and spatial liquid distribution inside the absorber are recognized as weak areas of knowledge requiring further investigation. CFD tools offer a possible method to investigating such topics and gaining a better understanding of their influence on reactor performance. This report focuses first on describing a hydrodynamic model for countercurrent gas-liquid flow through a packed column and then on the chemistry, heat and mass transfer specific to CO 2 absorption using monoethanolamine (MEA). The indicated model is implemented in MFIX, a CFD open source software package. The user defined functions needed to build this model are described in detail along with the keywords for the corresponding input file. A test case is outlined along with a few results. The example serves to briefly illustrate the developed CFD tool and its potential capability to investigate solvent absorption.

09 BIOMASS FUELS↗

Experiments and CFD simulation of mass transfer and hydrodynamics in a cylindrical bubble column

Flow visualization, Particle Image Velocimetry (PIV) and dissolved oxygen charging experiments are carried out in a small-scale cylindrical air-water bubble column at different superficial gas velocities. Void fraction profile, total gas holdup, liquid phase velocity field and volumetric mass transfer coefficient are obtained. Details of each experiment are given, with a new procedure for obtaining a 2D void fraction profile from flow visualization by image processing and time averaging which could provide useful information for CFD model validation. The experimental results are analyzed and compared with simulations where good agreement is found for both local and global flow patterns. The averaged governing equations and constitutive relations used in the simulation are discussed briefly, with emphasis on the proper comparison between simulations and experiments based on the derivation of the two-fluid model. Finally, by conducting three sets of experiments related to phase distribution, velocity field and mass transfer in the same apparatus, a validated CFD model for multiphase mass transfer is established and can be used in the future design of a multi-phase reactor.

42 ENGINEERING↗

A broadly-applicable unified closure relation for Taylor bubble rise velocity in pipes with stagnant liquid

Taylor bubble velocity in slug flow is a closure relation which significantly affects the prediction of liquid holdup (or void fraction) and pressure gradient in mechanistic models of slug flow for oil and gas pipe applications. In this work, we use a validated Computational Fluid Dynamics (CFD) approach to simulate the motion of Taylor bubbles in pipes; the interface is tracked with a Level-Set method implemented in a commercial code. A large numerical database is generated covering the most ample range of fluid properties and pipe inclination angles explored to date (Eo ∊ [10, 700],Mo ∊ [1 x 10 -6 , 5 x 10 3 , and θ ∊ [0°, 90°]). A unified Taylor bubble rise velocity correlation is extracted from that database. The new correlation predicts the numerical database with 8.6% absolute average relative error and a coefficient of determination R 2 = 0.97 and other available experimental data with 13.0% absolute average relative error and R 2 = 0.84 outperforming existing correlations and models.

Mechanics↗

Cryogenic distillation facility for isotopic purification of protium and deuterium

Isotopic purification of the protium and deuterium is an important requirement of many physics experiments. A cryogenic facility for high-efficiency separation of hydrogen isotopes with a cryogenic distillation column as the main element is described. The instrument is portable, so that it can be used at the experimental site. It was designed and built at the Petersburg Nuclear Physics Institute, Gatchina, Russia. Fundamental operating parameters have been measured including a liquid holdup in the column packing, the pressure drops across the column and the purity of the product at different operating modes. A mathematical model describes expected profiles of hydrogen isotope concentration along the distillation column. An analysis of ortho-parahydrogen isomeric composition by gas chromatography was used for evaluation of the column performance during the tuning operations. The protium content during deuterium purification (≤100 ppb) was measured using gas chromatography with accumulation of the protium in the distillation column. A high precision isotopic measurement at the Institute of Particle Physics, ETH-Zurich, Switzerland, provided an upper bound of the deuterium content in protium (≤6 ppb), which exceeds all commercially available products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational Fluid Dynamics (CFD) Simulations of Taylor Bubbles in Vertical and Inclined Pipes with Upward and Downward Liquid Flow

Summary Two-phase flow is a common occurrence in pipes of oil and gas developments. Current predictive tools are based on the mechanistic two-fluid model, which requires the use of closure relations to predict integral flow parameters such as liquid holdup (or void fraction) and pressure gradient. However, these closure relations carry the highest uncertainties in the model. In particular, significant discrepancies have been found between experimental data and closure relations for the Taylor bubble velocity in slug flow, which has been determined to strongly affect the mechanistic model predictions (Lizarraga-García 2016). In this work, we study the behavior of Taylor bubbles in vertical and inclined pipes with upward and downward flow using a validated 3D computational fluid dynamics (CFD) approach with level set method implemented in a commercial code. A total of 56 cases are simulated, covering a wide range of fluid properties, pipe diameters, and inclination angles: Eo ∈ [10, 700]; Mo ∈ [1×10–6, 5×103]; ReSL ∈ [–40, 10]; θ ∈ [5°, 90°]. For bubbles in vertical upward flows, the simulated distribution parameter, C0, is successfully compared with an existing model. However, the C0 values of downward and inclined slug flows where the bubble becomes asymmetric are shown to be significantly different from their respective vertical upward flow values, and no current model exists for the fluids simulated here. The main contributions of this work are (1) the relatively large 3D numerical database generated for this type of flow, (2) the study of the asymmetric nature of inclined and some vertical downward slug flows, and (3) the analysis of its impact on the distribution parameter, C0.

Engineering↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗