Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid in tanks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Monitoring of inventory in enclosed turbulent liquid tanks using floating gamma-ray sources

An accurate and simple technique utilizing a low-intensity gamma-ray source floating in a vertical tube, whose configuration is tank geometry and size dependent, is shown to eliminate the disturbing effects of turbulent fluid on enclosed tank liquid inventory measurement. The vertical tube aligns the source with detectors positioned outside of the tank, and collapses the turbulent liquid surface to a true average level. The exit attenuation of the information carrying high energy gamma rays is insensitive to liquid surface tubulence, and sensing probe penetrations are not necessary. It is found that for a half-full tank, 1.0 percent statistical error, and 1-s measuring times, that a 220 C Ce-137 source is required for an 8-ft high tank. Consistent experimental results are found for the dual detector method, and results indicate that the accuracy of the scanning side detector method is dependent on the quality of the collimator and degree of lower level energy discrimination.

Klein, R. M.↗

High speed machining of space shuttle external tank liquid hydrogen barrel panel

Actual and projected optimum High Speed Machining data for producing shuttle external tank liquid hydrogen barrel panels of aluminum alloy 2219-T87 are reported. The data included various machining parameters; e.g., spindle speeds, cutting speed, table feed, chip load, metal removal rate, horsepower, cutting efficiency, cutter wear (lack of) and chip removal methods.

Hankins, J. D.↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

Reusable Cryogenic-Liquid Tank With Replaceable Liner

Conceptual tank with replaceable liner holds liquid propellant and is suitable for reuse in spacecraft propulsion systems. Main components are: composite outer shell for containment of pressure, replaceable membrane liner, and foam-filled honeycomb sandwich bonded to inside of tank to insulate and stabilize wall of tank. Concept maximizes potential of filament-wound composite pressure shells with strength-to-density ratios five times those of comparable aluminum shells. Reduction in weight as much as 50 percent.

Freeman, William T., Jr.↗

Insulation For Cryogenic-Liquid Tanks

Rigid foam and radiation shields prevent excessive heating in variety of environments. Report discusses design, development, and test of thermal-protection system for liquid-oxygen and liquid-hydrogen tanks of now discontinued Shuttle/Centaur G' project. System protects tank from excessive heat before and during launches, while in orbit around Earth, and during premature landings from aborted launches. Designed to withstand stresses of launch and emergency landing, acoustical loads, rapid changes in pressure, and impingement of rapidly flowing gas near vents of cargo bay in Space Shuttle. Primary requirements in design, system presents no hazard to Space Shuttle or its crew.

Knoll, Richard H.↗

Analysis of the Pressure Rise in a Partially Filled Liquid Tank in Microgravity with Low Wall Heat Flux and Simultaneous Boiling and Condensation

Experiments performed with Freon 113 in the space shuttle have shown that in a pro- cess of very slow heating, high liquid superheats can be sustained for a long period in microgravity. In a closed system explosive vaporization of superheated liquid resulted in pressure spikes of varying magnitudes. In this paper, we analyze the pressure rise in a partially lled closed tank in which a large vapor bubble (i.e., ullage) is initially present, and the liquid is subjected to a low wall heat ux. The liquid layer adjacent to the wall becomes superheated until the temperature for nucleation of the bubbles (or the incipience of boiling) is achieved. In the absence of the gravity-induced convection large quantities of superheated liquid can accumulate over time near the heated surface. Once the incipience temperature is attained, explosive boiling occurs and the vapor bubbles that are produced on the heater surface tend to quickly raise the tank pressure. The liquid-vapor saturation temperature increases as well. These two e ects tend to induce condensation of the large ullage bubble that is initially present, and tends to mitigate the tank pressure rise. As a result, the tank pressure is predicted to rise sharply, attain a maximum, and subsequently decay slowly. The predicted pressure rise is compared with experimental results obtained in the microgravity environments of the space shuttle for Freon 113. The analysis is appli- cable, in general to heating of liquid in closed containers in microgravity and to cryogenic fuel tanks, in particular where small heat leaks into the tank are unavoidable.

Hasan, Mohammad M.↗

External Tank Liquid Hydrogen (LH2) Prepress Regression Analysis Independent Review Technical Consultation Report

The request to conduct an independent review of regression models, developed for determining the expected Launch Commit Criteria (LCC) External Tank (ET)-04 cycle count for the Space Shuttle ET tanking process, was submitted to the NASA Engineering and Safety Center NESC on September 20, 2005. The NESC team performed an independent review of regression models documented in Prepress Regression Analysis, Tom Clark and Angela Krenn, 10/27/05. This consultation consisted of a peer review by statistical experts of the proposed regression models provided in the Prepress Regression Analysis. This document is the consultation's final report.

Parsons, Vickie s.↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Differential expansion fitting for cryogenic liquid tanks

Sliding contact between liner and interior surface of fitting accommodates stresses and strains developed in shell composite and metal liner system. Stresses and strains are transmitted to liner portion which is recessed in fitting and which acts as differential expansion fitting.

Landes, R. E.↗

X Ray Measurement of Tank Liquid Level

Liquid surface observed through metal container wall, allowing direct determination of quantities and changes. X-ray measurement of liquid level produces photograph in which liquid appears as solid dark mass. Commercially-available portable X-ray machine is used.

Macias, R. G.↗

Large Spun Formed Friction-Stir Welded Tank Domes for Liquid Propellant Tanks Made from AA2195: A Technology Demonstration for the Next Generation of Heavy Lift Launchers

Improving structural efficiency while reducing manufacturing costs are key objectives when making future heavy-lift launchers more performing and cost efficient. The main enabling technologies are the application of advanced high performance materials as well as cost effective manufacture processes. This paper presents the status and main results of a joint industrial research & development effort to demonstrate TRL 6 of a novel manufacturing process for large liquid propellant tanks for launcher applications. Using high strength aluminium-lithium alloy combined with the spin forming manufacturing technique, this development aims at thinner wall thickness and weight savings up to 25% as well as a significant reduction in manufacturing effort. In this program, the concave spin forming process is used to manufacture tank domes from a single flat plate. Applied to aluminium alloy, this process allows reaching the highest possible material strength status T8, eliminating numerous welding steps which are typically necessary to assemble tank domes from 3D-curved panels. To minimize raw material costs for large diameter tank domes for launchers, the dome blank has been composed from standard plates welded together prior to spin forming by friction stir welding. After welding, the dome blank is contoured in order to meet the required wall thickness distribution. For achieving a material state of T8, also in the welding seams, the applied spin forming process allows the required cold stretching of the 3D-curved dome, with a subsequent ageing in a furnace. This combined manufacturing process has been demonstrated up to TRL 6 for tank domes with a 5.4 m diameter. In this paper, the manufacturing process as well as test results are presented. Plans are shown how this process could be applied to future heavy-lift launch vehicles developments, also for larger dome diameters.

Stachulla, M.↗

X-33 Liquid Hydrogen Tanks

The liquid hydrogen tank is a multi-lobe graphite/epoxy tank with integrally bonded, woven composite joints. The tanks are broken down into three major subgroups: aft dome/bulkhead, mid barrel section, and the forward dome/bulkhead. The vehicle uses two tanks (a left and right hand tank) as the "aft fuselage" of the vehicle, to react all body bending loads, landing gear loads, canted and vertical fin loads and air loads, as well as being used as the cryogenic fuel cells.

Adams, Andrew J.↗

Advanced collapsible tank for liquid containment

Tanks for bulk liquid containment will be required to support advanced planetary exploration programs. Potential applications include storage of potable, process, and waste water, and fuels and process chemicals. The launch mass and volume penalties inherent in rigid tanks suggest that collapsible tanks may be more efficient. Collapsible tanks are made of lightweight flexible material and can be folded compactly for storage and transport. Although collapsible tanks for terrestrial use are widely available, a new design was developed that has significantly less mass and bulk than existing models. Modelled after the shape of a sessible drop, this design features a dual membrane with a nearly uniform stress distribution and a low surface-to-volume ratio. It can be adapted to store a variety of liquids in nearly any environment with constant acceleration field. Three models of 10L, 50L, and 378L capacity have been constructed and tested. The 378L (100 gallon) model weighed less than 10 percent of a commercially available collapsible tank of equivalent capacity, and required less than 20 percent of the storage space when folded for transport.

Flanagan, David T.↗