Search NASA⌕ Search

SEARCH · Search NASA

Results for “liquid scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Direct measurement of carbon-14 in carbon dioxide by liquid scintillation counting

Liquid scintillation counting technique is applied to the direct measurement of carbon-14 in carbon dioxide. This method has high counting efficiency and eliminates many of the basic problems encountered with previous techniques. The technique can be used to achieve a percent substitution reaction and is of interest as an analytical technique.

Horrocks, D. L.↗

Results of low energy background measurements with the Liquid Scintillation Detector (LSD) of the Mont Blanc Laboratory

The 90 tons liquid scintillation detector (LSD) is fully running since October 1984, at a depth of 5,200 hg/sq cm of standard rock underground. The main goal is to search for neutrino bursts from collapsing stars. The experiment is very sensitive to detect low energy particles and has a very good signature to gamma-rays from (n,p) reaction which follows the upsilon e + p yields n + e sup + neutrino capture. The analysis of data is presented and the preliminary results on low energy measurements are discussed.

Aglietta, M.↗

Comparison of neutron spectra measured with three sizes of organic liquid scintillators using differentiation analysis

Proton recoil distributions were obtained by using organic liquid scintillators of different size. The measured distributions are converted to neutron spectra by differentiation analysis for comparison to the unfolded spectra of the largest scintillator. The approximations involved in the differentiation analysis are indicated to have small effects on the precision of neutron spectra measured with the smaller scintillators but introduce significant error for the largest scintillator. In the case of the smallest cylindrical scintillator, nominally 1.2 by 1.3 cm, the efficiency is shown to be insensitive to multiple scattering and to the angular distribution to the incident flux. These characteristics of the smaller scintillator make possible its use to measure scalar flux spectra within media high efficiency is not required.

Shook, D. F.↗

The research program of the Liquid Scintillation Detector (LSD) in the Mont Blanc Laboratory

A massive (90 tons) liquid scintillation detector (LSD) has been running since October 1984 in the Mont Blanc Laboratory at a depth of 5,200 hg/sq cm of standard rock. The research program of the experiment covers a variety of topics in particle physics and astrophysics. The performance of the detector, the main fields of research are presented and the preliminary results are discussed.

Dadykin, V. L.↗

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.↗

Large area double scattering telescope for balloon-borne studies of neutrons and gamma rays

A large area double scattering telescope for balloon-borne research is described. It measures the flux, energy and direction of 2-100 MeV neutrons and 0.5-30 MeV gamma rays. These measurements are made using time-of-flight and pulse height analysis techniques with two large tanks of mineral oil liquid scintillator. Results from Monte Carlo calculations of the efficiency, energy resolution and angular resolution are presented and the electronics implementation for the processing of 80 photomultiplier tubes signals will be discussed. The detector weighs 800 kg with a large part of this weight being the liquid scintillator (320 kg). It will be flown at 3 mbars for flight durations up to 40 hours. The first flight is planned for Spring, 1975.

Zych, A. D.↗

Recent development in organic scintillators

Discussion on recent developments of organic scintillators includes studies of organic compounds that form glass-like masses which scintillate and are stable at room temperature, correlations between molecular structure of organic scintillators and self-quenching, recently developed fast scintillators, and applications of liquid-scintillation counters.

Horrocks, D. L.↗

Search for 1/3e and 2/3e charged quarks in the cosmic radiation at 2750-m altitude.

A scintillation counter telescope consisting of eight liquid scintillation counters and four wide-gap spark chambers was used to search for particles with electric charge 1/3e and 2/3e in cosmic rays at 2750 m above sea level. No such particles were detected during the 1500-hr experimental run. Upper limits on the vertical fluxes are established, and estimates of the corresponding sea-level fluxes are made for comparison with previous results.

Cox, A. J.↗

Double Compton scatter telescope calibration

Calibration techniques for a medium energy gamma ray telescope are described. Gain calibration using Compton edge spectra involves comparisons of pulse height spectra with spectra simulated by a Monte Carlo computer code which includes Compton scattering and pair production, plural scattering and variable energy resolution, and cell size. The telescope considered comprises 56 cells of liquid scintillator in four size groups, with a total liquid volume of 325 l; each cell has its own photomultiplier tube. Energy and angular resolutions and the PMT gain calibration procedure are verified with double scatter data for monoenergetic gamma rays at a known location. Detection probabilities for any cell combination in the two telescope arrays are calculated per steradian as a function of the scattering for a number of different energies with a Van de Graaff accelerator.

Dayton, B.↗

Monopole search below the Parker limit with the MACRO detector at Gran Sasso

The MACRO detector approved for the Gran Sasso Underground Laboratory in Italy will be the first capable of performing a definitive search for super-massive grand unified theory (GUT) monopoles at a level significantly below the Parker flux limit of 10 to the minus 15th power square centimeters Sr(-1) 5(-1). GUT monopoles will move at very low velocities (V approx. 0.001 c) relative to the Earth and a multifaceted detection technique is required to assume their unambiguous identification. Calculations of scintillator response to slow monopoles and measurements of scintillation efficiency for low energy protons have shown that bare monopoles and electrically charged monopoles moving at velocities as low as 5 x .0001 c will produce detectable scintillation signals. The time-of-flight between two thick (25 cm) liquid scintillation layers separated by 4.3m will be used in conjunction with waveform digitization of signals of extended duration in each thick scintillator to provide a redundant signature for slow penetrating particles. Limited streamer tubes filled with He and n-pentane will detect bare monopoles with velocities as low as 1 x 0.0001 c by exploiting monopole induced level mixing and the Penning effect.

Tarle, G.↗

Prolonged triboluminescence in clays and other minerals

Samples of various clays and minerals were ground or fractured and monitored with a liquid scintillation spectrometer in order to obtain triboluminescent decay curves. Kaolinite samples displayed several million counts/min after grinding, with a surface area emission estimated at tens of billions of photons/sq cm of surface. The photon production rates varied with the origin of the sample, and kaolinite continually yielded higher production rates than bentonite. The addition of water to the samples slightly increased the count rate of emitted light, while the addition of the fluorescent molecule substance tryptofan significantly enhanced the count rate. Freezing smears of kaolinite and montmorillonite in liquid nitrogen and in a salt ice mixture also induced triboluminescence in the montmorillonite. A possible connection between powdery triboluminescent materials formed in mining industries and respiratory disorders among miners is suggested.

Lahav, N.↗

Chemical Method of Urine Volume Measurement

A system has been developed and qualified as flight hardware for the measurement of micturition volumes voided by crewmen during Gemini missions. This Chemical Urine Volume Measurement System (CUVMS) is used for obtaining samples of each micturition for post-flight volume determination and laboratory analysis for chemical constituents of physiological interest. The system is versatile with respect to volumes measured, with a capacity beyond the largest micturition expected to be encountered, and with respect to mission duration of inherently indefinite length. The urine sample is used for the measurement of total micturition volume by a tracer dilution technique, in which a fixed, predetermined amount of tritiated water is introduced and mixed into the voided urine, and the resulting concentration of the tracer in the sample is determined with a liquid scintillation spectrometer. The tracer employed does not interfere with the analysis for the chemical constituents of the urine. The CUVMS hardware consists of a four-way selector valve in which an automatically operated tracer metering pump is incorporated, a collection/mixing bag, and tracer storage accumulators. The assembled system interfaces with a urine receiver at the selector valve inlet, sample bags which connect to the side of the selector valve, and a flexible hose which carries the excess urine to the overboard drain connection. Results of testing have demonstrated system volume measurement accuracy within the specification limits of +/-5%, and operating reliability suitable for system use aboard the GT-7 mission, in which it was first used.

QUANTITATIVE ANALYSIS↗