Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗

Analysis of Radioactive Waste and Contamination using 3D Position-Sensitive CdZnTe Detectors

INTRODUCTION The US has surplus plutonium. This material will be diluted in gloveboxes at SRS [Ref 1 and 2]. This process will create holdup. Holdup is material in an unexpected or unwanted location. Because this holdup material is primarily PuO2, it must be accounted for (measured). This measurement is typically done using a liquid-nitrogen cooled, HPGe detector. To enable more rapid processing, advanced holdup technologies are being explored [Ref 3 and 4]. METHODS For the surplus plutonium dilute and dispose program, the traditional detector system could slow down the optimal operational tempo of the program. A multiple-detector system, providing complete glovebox coverage, based on CdZnTe crystals, 3D-positioning electronics, and a coded aperture mask, is in the process of being developed by ORNL and SRNL [Ref 4].

Whiteside, Tad [Savannah River National Laboratory↗

Effects of surface contamination on the infrared emissivity and visible-light scattering of highly reflective surfaces at cryogenic temperatures

A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible-light scattering, and reflectance of contaminant films on a highly reflective liquid-nitrogen cooled, stainless steel substrate. Emissivities and scattering data are obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Of the contaminants investigated, water has by far the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. The emissivity increases more rapidly with film thickness between zero and 2.5 microns than at thicknesses greater than 2.5 microns. Scattering of visible light changes very little below 2 microns thickness but increases rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.

Viehmann, W.↗

Stratospheric ozone measurement with an infrared heterodyne spectrometer

Measurements of a stratospheric ozone concentration profile are made by detecting infrared absorption lines with a heterodyne spectrometer. The infrared spectrometer is based on a line-by-line tunable CO2 lasers, a liquid-nitrogen cooled HgCdTe photomixer, and a 64-channel spectral line receiver. The infrared radiation from the source is mixed with local-oscillator radiation. The difference frequency signal in a bandwidth above and below the local-oscillator frequency is detected. The intensity in each sideband is found by subtracting sideband contributions. It is found that absolute total column density is 0.32 plus or minus 0.02 cm-atm with a peak mixing ratio at about 24 km. The (7,1,6)-(7,1,7) O3 line center frequency is identified as 1043.1772/cm. Future work will involve a number of ozone absorption lines and measurements of diurnal variation. Completely resolved stratospheric lines may be inverted to yield concentration profiles of trace constituents and stratospheric gases.

Abbas, M. M.↗

Constance mirror program: Progress and plans

The current state of the mechanics of the Constance II experiment, the physics results gathered, the motivation background, and future plans for the Constance II experiment are reviewed. Several improvements have been made and several experimental investigations have been completed. These include the construction/installation/testing of: (1) liquid-nitrogen cooled, Ioffe bars installed, (2) a diverter coil (3) the 100 kW ICRF generator, (4) the data acquisition system, and (5) the optimum hot-iron operation of the machine with Titanium and pulsed-gas plasma guns. Measurements were made of the density, temperature, and radius of the plasma. Ion-cyclotron fluctuations were observed, their bandwidth measured, and data collected demonstrating resonance heating. New X-ray diagnostics were designed and purchased, and progress on the Thomson scattering was made. Finally, a new hot cathode gun was designed and constructed.

Klinkowstein, R. E.↗

Balloon-borne cryogenic spectrometer for measurement of lower stratospheric trace constituents

A liquid-nitrogen cooled, multidetector Fourier transform spectrometer has been constructed to measure minor stratospheric constituents via high resolution, earth-limb emission spectroscopy from a balloon-borne platform. Cryogenic cooling, combined with the use of extrinsic silicon photoconductor detectors cooled to liquid-helium temperature, allows the detection of weak emission features of gaseous species. The spectrometer has two basic scan modes: the first mode records the continuous spectrum from 650-2100/cm with 0.2/cm resolution; the second simultaneously records four preselected narrow intervals (about 175/cm bandpass each) with 0.02/cm resolution, unapodized. Filtering of the interferogram signal is done by real-time, digital signal processing. The most important feature of this flat mirror Michelson system, with respect to remote balloon-borne operation, is the dynamic alignment system which maintains the relative parallelism of the two flat reflectors of the interferometer. Species identified to date in data obtained during a Nov. 6, 1984, flight include: CO2, O3, H2O, CH4, HNO3, N2O, NO2, NO, CCl3F (Freon-11) and CF2Cl2 (Freon-12).

Brasunas, J. C.↗

High resolution, balloon-borne emission spectroscopy of trace species in the lower stratosphere - N2O5, HNO3

A liquid-nitrogen cooled Fourier transform spectrometer (SIRIS) measures thermal limb-emission of the stratosphere from a balloon platform at a nominal altitude of 40 km, under night and day conditions, with a 3 km vertical resolution. N2O5 and HNO3 mixing ratios inferred from emission spectra are compared with previous measurements and with the predictions from a one-dimensional photochemical model.

Brasunas, J.↗

A unified planar measurement technique for compressible flows using laser-induced iodine fluorescence

A unified laser-induced fluorescence technique for conducting planar measurements of temperature, pressure and velocity in nonreacting, highly compressible flows has been developed, validated and demonstrated. Planar fluorescence from iodine, seeded into air, was induced by an argon-ion laser and collected using a liquid-nitrogen cooled CCD camera. In the measurement technique, temperature is determined from the fluorescence induced with the laser operated broad band. Pressure and velocity are determined from the shape and position of the fluorescence excitation spectrum which is measured with the laser operated narrow band. The measurement approach described herein provides a means of obtaining accurate, spatially-complete maps of the primary flow field parameters in a wide variety of cold supersonic and transonic flows.

Hartfield, Roy J., Jr.↗

The Effect of Martian Dust on Radiator Performance

Experiments were performed in which the effective emittance of three types of radiator Coatings was measured as Martian dust simulant was added to the radiator face. The apparatus consisted of multiple radiator coupons on which Carbondale Red Clay dust was deposited. The coupons were powered by electric heaters, using a guard-heating configuration to achieve the accuracy required for acceptable emittance calculations. The apparatus was containing in a vacuum chamber that featured a liquid-nitrogen cooled shroud that simulated the Martian sky temperature. Radiator temperatures ranged from 250 to 350 K with sky temperatures from 185 to 248 K. Results show that as dust was added to the radiator surfaces, the effective emittance of the high - emittance coatings decreased from near 0.9 to a value of about 0.5. A low-emittance control surface, polished aluminum, demonstrated a rise in effective emittance for thin dust layers, and then a decline as the dust layer thickened. This behavior is attributed to the conductive resistance caused by the dust layer.

Hollingsworth, D. Keith↗

Remote Measurement of Atmospheric Temperatures By Raman Lidar

The Raman shifted return of a lidar, or optical radar, system has been utilized to make atmospheric temperature measurements. These measurements were made along a horizontal path at temperatures between -20 C and +30 C and at ranges of about 100 meters. The temperature data were acquired by recording the intensity ratio of two portions of the Raman spectrum which were simultaneously sampled from a preset range. The lidar unit employed in this testing consisted of a 4 joule-10ppm laser operating at 694.3 nm, a 10-inch Schmidt-Cassegrain telescope, and a system of time-gated detection and signal processing electronics. The detection system processed three return signal wavelength intervals - two intervals along the rotational Raman scattered spectrum and one interval centered at the Rayleigh-Mie scattered wavelength. The wavelength intervals were resolved by using a pellicle beam splitter and three optical interference filters. Raman return samples were taken from one discrete range segment during each test shot and the signal intensities were displayed in digital format. The Rayleigh-Mie techniques. The test site utilized to evaluate this measurement technique encompassed a total path length of 200 meters. Major components of the test site included a trailer-van housing the lidar unit, a controlled environment test zone, and a beam terminator. The control zone which was located about 100 meters from the trailer was 12 meters in length, 2.4 meters in diameter, and was equipped with hinged doors at each end. The temperature of the air inside the zone could be either raised or lowered with respect to ambient air through the use of infrared heaters or a liquid-nitrogen cooling system. Conditions inside the zone were continuously monitored with a thermocouple rake assembly. The test path length was terminated by a 1.2 meter square array of energy absorbing cones and a flat black screen. Tests were initially conducted at strictly ambient conditions utilizing the normal outside air temperatures as a test parameter. These tests provided a calibration of the Raman intensity ratio as a function of' temperature for the particular optical-filter arrangement used in this system while also providing a test of' the theoretical prediction formulated in the design of the system. Later tests utilized zone temperatures above and below ambient to provide temperature gradient data. These tests indicate that ten shots, or one minute of' data acquisition, from a 100 meter range can provide absolute temperature measurements with an accuracy of + 30 C and a range resolution of about 5 meters. Because this measurement accuracy compares well with that predicted for this particular unit, it is suggested that a field-application system could be built with signif'icant improvements in both absolute accuracy and range.

Salzman, Jack A.↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A cantilevered liquid-nitrogen-cooled silicon mirror for the Advanced Light Source Upgrade

This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.

47 OTHER INSTRUMENTATION↗

Cryogenic Vacuum Pump

System provides high pumping capacity even for noble gases. First stage, removes water and CO2 from input gas. Second stage, removes noble gases except helium and some lighter gases not trapped by first stage. Third stage, traps all remaining gases. All three stages mounted inside liquid-nitrogen Dewar that cools first stage. Pump small enough for general laboratory use.

Zachman, C. A.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Investigating the Effects of Temperature on the Signatures of Shocks Propagated Through Impacts into Minerals Found in Comets and Asteroids

Comets and asteroids are subjected to extremely cold conditions throughout their lifetimes. During their sojourns in the solar system, they are subjected to collisions at speeds that are easily capable of generating shock waves in their constituent materials. In addition to ices, more common silicate minerals such as olivines and pyroxenes are important components of these objects. The collision-induced shocks could affect the spectral signatures of those mineral components, which could in turn be detected telescopically. We have embarked on a project to determine how impact-generated shock might affect the reflectance spectra and structures of select silicates as both impact speed and target temperature are varied systematically. While the effects of impact speed (in the form of shock stress) on numerous materials have been and continue to be studied, the role of target temperature has received comparatively little attention, presumably because of the operational difficulties it can introduce to experimentation. Our experiments were performed with the vertical gun in the Experimental Impact Laboratory of the Johnson Space Center. A liquid-nitrogen system was plumbed to permit cooling of the target container and its contents under vacuum to temperatures as low as -100 C (173 K). Temperatures were monitored by thermocouples mounted on the outside of the target container. Because those sensors were not in contact with the target material at impact, the measured temperatures are treated as lower limits for the actual values. Peridot (Mg-rich olivine) and enstatite (Mg-rich orthopyroxene) were used as targets, which involved the impact of alumina (Al2O3) spheres at speeds of 2.0 - 2.7 km s(exp -1) and temperatures covering 25 C to -100 C (298 K to 173 K). We have begun collecting and analyzing data in the near to mid-IR with a Fourier-transform infrared spectrometer, and preliminary analyses show that notable differences in absorption-band strength and position occur as functions of both impact speed (peak shock stress) and initial temperature.

Lederer, Susan M.↗

Variable-temperature cryogenic trap for the separation of gas mixtures

The paper describes a continuous variable-temperature U-shaped cold trap which can both purify vacuum-line combustion products for subsequent stable isotopic analysis and isolate the methane and ethane constituents of natural gases. The canister containing the trap is submerged in liquid nitrogen, and, as the gas cools, the gas mixture components condense sequentially according to their relative vapor pressures. After the about 12 min required for the bottom of the trap to reach the liquid-nitrogen temperature, passage of electric current through the resistance wire wrapped around the tubing covering the U-trap permits distillation of successive gas components at optimal temperatures. Data on the separation achieved for two mixtures, the first being typical vacuum-line combustion products of geochemical samples such as rocks and the second being natural gas, are presented, and the thermal behavior and power consumption are reported.

Des Marais, D. J.↗

New techniques for far-infrared filters.

The techniques considered make it possible to construct high performance low-pass wide-band, and medium-band filters at wavelengths in the range from 25 to 300 micrometers. Short wavelength rejection without appreciable loss at long wavelengths is achieved by means of small particle scattering. Spectral definition in the far infrared is obtained by cooling one or more crystalline materials to liquid-He or liquid-nitrogen temperatures. The problem of reflection losses at the various surfaces is solved by a new antireflection coating technique.

Armstrong, K. R.↗

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen↗