Search NASA⌕ Search

SEARCH · Search NASA

Results for “load profile cluster”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile: Preprint

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

Preventive Power Outage Estimation Based on A Novel Scenario Clustering Strategy: Preprint

The increasing occurrence of extreme weather events is challenging the power grid operation. In front of the extreme weather, the system operator is responsible for estimating the power outage and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The predicted vulnerable lines of an outage prediction model tool are utilized to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers the schedule of repair crews and mobile energy resources. Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative ones for straightforward analysis. Finally, case studies on a distribution system evaluate the damage level brought by extreme weather and verify the effectiveness of the proposed scenario clustering strategy.

mobile energy resources↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis: Preprint

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Demographic Information Incorporated Household Energy Consumption Analysis

The high energy consumption from residential buildings provides them large potential to participate in demand response programs. To design appropriate demand response programs for residential buildings, it is important for electric utilities to know the energy consumption characteristics for different types of households so that utilities can send requests to the groups with a higher possibility to successfully respond. In this paper, we develop a load model to generate synthetic load profiles for different types of households incorporating demographical information including Current Population Survey data set and American Time Use Survey data set. The details of each data set and the details of the load models are presented. The synthetic household load profiles are generated by the load model and clustered into different groups based on state, age, number of occupants, income level, and city of the household. The average energy consumption characteristics for different groups of households are analyzed and compared, which will help electric utilities issue demand response signals to appropriate households.

building loads↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transfer Learning Trained LSTM Models for Household Load Profile Forecasting

Grid edge renewable energy resources, such as rooftop solar photovoltaics, closely interact with consumer load profiles. Therefore, forecasting future electricity demand, ideally at the individual household level, is indispensable. In this paper, we present a transfer learning enhanced household load profile forecasting method. First, we tune a long short-term memory forecasting model to perform day-ahead prediction of household electricity load profiles. Then we improve these individualized models using transfer learning, and we use k-means clustering to create optimal source data sets. We find average improvements of 4.38% (largest improvement of 10.71%) when the entire data set was used to train the source model and 2.45% (largest improvement of 11.57%) in the mean absolute error when households were first clustered and used to train separate source models for each cluster. We find that transfer learning with clustered data can effectively boost the forecasting performance of the LSTM models. We use realistic household power measurements for 148 real residential households in Austin, Texas.

deep learning↗

Representative Period Selection for Robust Capacity Expansion Planning in Low-carbon Grids

With the increasing urgency to decarbonize power systems, while mitigating extreme events, capacity expansion models can play a vital role in reliably planning the expansion of power systems and facilitating the integration of renewable energy sources. Optimizing capacity expansion generally involves selecting surrogate representative days from forecasts of load and the generation profiles of variable renewable energy resources. To properly select those representative days, we propose a novel input-based approach in combination with the k-means clustering algorithm that utilize three unique operational inputs: load shedding, renewable curtailment, and transmission congestion. The proposed method allows for more robust and cost-effective capacity planning. The method is validated using a capacity expansion model and a production cost model based on California Independent System Operator (CAISO)'s decarbonization goals, and results in reduced costs and drastically lower load shedding.

Anderson, Osten P.↗

Relating FTS Catalyst Properties to Performance

During the reporting period June 23, 2011 to August 31, 2013, CAER researchers carried out research in two areas of fundamental importance to the topic of cobalt-based Fischer-Tropsch Synthesis (FTS): promoters and stability. The first area was research into possible substitute promoters that might be used to replace the expensive promoters (e.g., Pt, Re, and Ru) that are commonly used. To that end, three separate investigations were carried out. Due to the strong support interaction of γ-Al2O3 with cobalt, metal promoters are commonly added to commercial FTS catalysts to facilitate the reduction of cobalt oxides and thereby boost active surface cobalt metal sites. To date, the metal promoters examined have been those up to and including Group 11. Because two Group 11 promoters (i.e., Ag and Au) were identified to exhibit positive impacts on conversion, selectivity, or both, research was undertaken to explore metals in Groups 12 - 14. The three metals selected for this purpose were Cd, In, and Sn. At a higher loading of 25%Co on alumina, 1% addition of Cd, In, or Sn was found to-on average-facilitate reduction by promoting a heterogeneous distribution of cobalt consisting of larger lesser interacting cobalt clusters and smaller strongly interacting cobalt species. The lesser interacting species were identified in TPR profiles, where a sharp low temperature peak occurred for the reduction of larger, weakly interacting, CoO species. In XANES, the Cd, In, and Sn promoters were found to exist as oxides, whereas typical promoters (e.g., Re, Ru, Pt) were previously determined to exist in an metallic state in atomic coordination with cobalt. The larger cobalt clusters significantly decreased the active site density relative to the unpromoted 25%Co/Al2O3 catalyst. Decreasing the cobalt loading to 15%Co eliminated the large non-interacting species. The TPR peak for reduction of strongly interacting CoO in the Cd promoted catalyst occurred at a measurably lower temperature than in the unpromoted catalyst. Nevertheless, the Co clusters remained slightly larger, on average, in comparison with the unpromoted 15%Co/Al2O3 reference catalyst. None of the promoted catalysts (i.e., with Cd, In, or Sn) exhibited surface Co0 site densities higher than that of the unpromoted catalyst. In activity testing, the activities were even much lower than what was expected from the H2-TPD results. Two possible explanations were proposed: (1) the promoters may be located on the surfaces of cobalt particles, blocking surface Co0 but being able to desorb hydrogen or (2) the promoters may facilitate Co oxidation during FTS, as previously observed by Huffman and coworkers when K was added to cobalt catalysts.

Zirconia↗

Persistent Elevated Soot Emissions Induced by Clustered Stochastic Preignition Events

Stochastic Preignition (SPI) is an abnormal combustion phenomenon that can occur in spark-ignition engines particularly under high-load operation. SPI is characterized by uncontrolled initiation of combustion prior to spark discharge, an abnormal combustion process that can lead to severe knock events and significant engine damage. SPI has been associated with fuel properties, lubricant composition, and engine design and operation. Here, in this work, a single-cylinder test engine with a dry-sump oil system was utilized to study the SPI response of E10 and E25 fuels with a range of Reid Vapor Pressure (RVP). An automated test procedure was employed, consisting of ten square-waved load profile segments, with each segment composed of 5 min of low-load operation followed by 25 min of sustained high-load operation. These tests were replicated across multiple days of testing including a lubricant triple flush between tests, and an online Fuel in Oil diagnostic measurement. Exhaust particulate emissions were continuously measured by an AVL microsoot sensor (MSS). Elevated particulate matter emissions were observed to occur concurrently with SPI events as blooms of soot. Particularly after clustered events (i.e., multiple SPI cycles occurring within 10 consecutive engine cycles), high soot emissions were observed to persist over several days of sequential operation despite daily lubricant changes, a complete warm-up procedure, and sustained low-load operation between test segments. This result implies that the particulate emissions trends may be dominated by deposit-based effects, where higher load operation is needed to alter deposition and formation processes. The observed soot blooms were also found to correspond to a reduction in the engine fueling and the fuel engine oil dilution rate despite the engine exhaust remaining at stoichiometric exhaust operation. These observations suggest that post-SPI events, pathways for lubricant migration and consumption into the combustion chamber may occur until these pathways are closed from deposit formation or ring dynamics during extended operation. These observed sooting propensity persisted with all fuels tests, but a linear correlation was observed between the summation of soot and particulate matter index (PMI) value for each fuel as well as SPI events, proving that PMI is a crucial fuel property for reducing SPI.

Splitter, Derek [Oak Ridge National Laboratory (OR↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

CGOLS V: Disk-wide Stellar Feedback and Observational Implications of the Cholla Galactic Wind Model

Abstract We present the fifth simulation in the Cholla Galactic OutfLow Simulation (CGOLS) project—a set of isolated starburst galaxy simulations modeled over large scales (10 kpc) at uniformly high resolution (Δx≈ 5 pc). Supernova feedback in this simulation is implemented as a disk-wide distribution of clusters, and we assess the impact of this geometry on several features of the resulting outflow, including the radial profiles of various phases; mass, momentum, and energy outflow rates; covering fraction of cool gas; mock absorption-line spectra; and X-ray surface brightness. In general, we find that the outflow generated by this model is cooler, slower, and contains more mass in the cool phase than a more centrally concentrated outflow driven by a similar number of supernovae. In addition, the energy loading factors in the hot phase are an order of magnitude lower, indicating much larger losses due to radiative cooling in the outflow. However, coupling between the hot and cool phases is more efficient than in the nuclear burst case, with almost 50% of the total outflowing energy flux carried by the cool phase at a radial distance of 5 kpc. These physical differences have corresponding signatures in observable quantities: the covering fraction of cool gas is much larger, and there is greater evidence of absorption in low and intermediate ionization energy lines. Taken together, our simulations indicate that centrally concentrated starbursts are more effective at driving hot, low-density outflows that will expand far into the halo, while galaxy-wide bursts may be more effective at removing cool gas from the disk.

Astronomy & Astrophysics↗

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load↗

From Cell to System: Accelerated hpc Simulations of BESS Aging under Frequency Regulation and Arbitrage use cases

Lithium-ion battery energy storage systems (BESS) packs have emerged as a leading solution for grid-scale energy storage, enhancing resiliency and balancing load fluctuations. Yet, experimental characterization of large-format LIB packs-particularly to assess performance and degradation over hundreds of cycles - demands substantial hardware investment and multi-year testing campaigns. In this work, we couple a hierarchical, physics-based modeling framework agnostic to electrode chemistries with high-performance computing to accelerate systems level evaluation by upto two orders of magnitude. Building on the open-source liionpack platform, we implement cell, module, and pack-scale electrochemical models enriched with mechanistic aging mechanisms and deploy them on an HPC cluster to simulate 150−200kWh systems over 500 - 1,000 cycles with in days. We subject these virtual B ESS to both constant-current cycling and realistic grid service profiles spanning frequency regulation, ramp-rate support, and energy arbitrage-and quantify the resulting degradation patterns. Our results reveal that localized cell aging can induce substantial nonuniformity at module and pack levels, with service-specific cycling protocols driving distinct aging modes. This rapid, multiscale modeling approach provides a powerful design-space exploration tool for optimizing electrical architecture, control strategies, and operational schedules to prolong pack lifetime and lower total cost of ownership.

Ayalasomayajula, Surya [ORNL] (ORCID:0009000860788↗