Search NASA⌕ Search

SEARCH · Search NASA

Results for “longitudinal comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Space Shuttle entry longitudinal aerodynamic comparisons of flight 2 with preflight predictions

An overview of the aerodynamic performance, longitudinal trim, and control surface effectiveness as developed from the second Shuttle flight is presented, along with comparisons with preflight predictions. The Orbiter enters the atmosphere at Mach 29 and descends through all the Mach speeds until touchdown. Control mechanisms for the Orbiter are outlined, noting the lessening of angle of attack as the terminal configuration is reached. Methods of developing the wind tunnel predictions are reviewed, including performance in different altitudes and speed regimes, and the impetus to decouple the flight control system from aerodynamics with respect to uncertainties. Preflight predictions agreed well with the lift/drag ratio above Mach 1, but higher L/D was exhibited than predicted below Mach 1. A deficiency in the wind tunnel environment was concluded for the inaccuracies in the predictions for hypersonic trim characteristics.

Romere, P. O.↗

Space shuttle entry longitudinal aerodynamic comparisons of flights 1-4 with preflight predictions

The Space Shuttle orbiter flight test program has required the aerodynamicist to take a new approach in determining flight characteristics. A conventional flight test program of slowly and cautiously approaching more severe flight conditions was not possible with the orbiter. On the first four orbital flights, The orbiter entered the atmosphere at approximately Mach 29 and decelerated through the Mach range (the subsonic portion of flight had also been flown by another orbiter vehicle during the Approach and Landing Test Program). Certification for these flights was achieved by an extensive wind tunnel test and analysis program. The initial series of flights of the orbiter were heavily instrumented for the purpose of obtaining accurate aerodynamic data. The flight data derived from the entry Mach range provided comparisons between flight and wind tunnel derived predicted data in the areas of both aerodynamic performance and longitudinal trim.

Romere, P. O.↗

On the averaging of cardiac diffusion tensor MRI data: the effect of distance function selection

Diffusion tensor magnetic resonance imaging (DT-MRI) allows a unique insight into the microstructure of highly-directional tissues. The selection of the most proper distance function for the space of diffusion tensors is crucial in enhancing the clinical application of this imaging modality. Both linear and nonlinear metrics have been proposed in the literature over the years. The debate on the most appropriate DT-MRI distance function is still ongoing. Here, in this paper, we presented a framework to compare the Euclidean, affine-invariant Riemannian and log-Euclidean metrics using actual high-resolution DT-MRI rat heart data. We employed temporal averaging at the diffusion tensor level of three consecutive and identically-acquired DT-MRI datasets from each of five rat hearts as a means to rectify the background noise-induced loss of myocyte directional regularity. This procedure is applied here for the first time in the context of tensor distance function selection. When compared with previous studies that used a different concrete application to juxtapose the various DT-MRI distance functions, this work is unique in that it combined the following: (i) metrics were judged by quantitative—rather than qualitative—criteria, (ii) the comparison tools were non-biased, (iii) a longitudinal comparison operation was used on a same-voxel basis. The statistical analyses of the comparison showed that the three DT-MRI distance functions tend to provide equivalent results. Hence, we came to the conclusion that the tensor manifold for cardiac DT-MRI studies is a curved space of almost zero curvature. The signal to noise ratio dependence of the operations was investigated through simulations. Finally, the 'swelling effect' occurrence following Euclidean averaging was found to be too unimportant to be worth consideration.

60 APPLIED LIFE SCIENCES↗

Longitudinal changes in PON1 enzymatic activities in Mexican-American mothers and children with different genotypes and haplotypes

The paraoxonase 1 (PON1) enzyme prevents low-density lipoprotein oxidation and also detoxifies the oxon derivatives of certain neurotoxic organophosphate (OP) pesticides. PON1 activity in infants is low compared to adults, rendering them with lower metabolic and antioxidant capacities. We made a longitudinal comparison of the role of genetic variability on control of PON1 phenotypes in Mexican-American mothers and their children at the time of delivery (n = 388 and 338, respectively) and again 7 years later (n = 280 and 281, respectively) using generalized estimating equations models. At age 7, children's mean PON1 activities were still lower than those of mothers. This difference was larger in children with genotypes associated with low PON1 activities (PON1{sub -108TT}, PON1{sub 192QQ}, and PON1{sub -909CC}). In mothers, PON1 activities were elevated at delivery and during pregnancy compared to 7 years later when they were not pregnant (p < 0.001). In non-pregnant mothers, PON1 polymorphisms and haplotypes accounted for almost 2-fold more variation of arylesterase (AREase) and chlorpyrifos-oxonase (CPOase) activity than in mothers at delivery. In both mothers and children, the five PON1 polymorphisms (192, 55, -108, -909, -162) explained a noticeably larger proportion of variance of paraoxonase activity (62-78%) than AREase activity (12.3-26.6%). Genetic control of PON1 enzymatic activity varies in children compared to adults and is also affected by pregnancy status. In addition to known PON1 polymorphisms, unidentified environmental, genetic, or epigenetic factors may also influence variability of PON1 expression and therefore susceptibility to OPs and oxidative stress.

60 APPLIED LIFE SCIENCES↗

Spincaloritronic Measurements: A Round Robin Comparison of the Longitudinal Spin Seebeck Effect

The rising field of spin caloritronics focuses on the interactions between spin and heat currents in a magnetic material; the observation of the spin Seebeck effect opened the route to this branch of research. This paper reports the results of a round robin test performed by five partners on a single device highlighting the reproducibility problems related to the measurements of the spin Seebeck coefficient, the quantity that describes the strength of the spin Seebeck effect. Here, this work stimulated the search for more reproducible measurement methods through the analysis of the systematic effects.

47 OTHER INSTRUMENTATION↗

Simulation comparison of a decoupled longitudinal control system and a velocity vector control wheel steering system during landings in wind shear

A simulator comparison of the velocity vector control wheel steering (VCWS) system and a decoupled longitudinal control system is presented. The piloting task was to use the electronic attitude direction indicator (EADI) to capture and maintain a 3 degree glide slope in the presence of wind shear and to complete the landing using the perspective runway included on the EADI. The decoupled control system used constant prefilter and feedback gains to provide steady state decoupling of flight path angle, pitch angle, and forward velocity. The decoupled control system improved the pilots' ability to control airspeed and flight path angle during the final stages of an approach made in severe wind shear. The system also improved their ability to complete safe landings. The pilots preferred the decoupled control system in severe winds and, on a pilot rating scale, rated the approach and landing task with the decoupled control system as much as 3 to 4 increments better than use of the VCWS system.

Kimball, G., Jr.↗

Supersonic full-potential methods for missile body analysis

Accounts are presented of representative applications to missile bodies of arbitrary shape of methods based on the steady form of the full potential equation. The NCOREL and SIMP full-potential codes are compared, and their results are evaluated for the cases of an arrow wing and a wing-body configuration. Attention is given to the effect of cross-sectional and longitudinal geometries. Comparisons of surface pressure and longitudinal force and moment data for circular and elliptic bodies have shown that the full-potential methods yielded excellent results in attached-flow conditions. Results are presented for a conical star body, waveriders, the Shuttle Orbiter, and a highly swept wing-body cruising at Mach 4.

Pittman, James L.↗

Estimation of longitudinal aerodynamic coefficients and comparison with wind-tunnel values

Some recent experience at Ames Research Center in the estimation of aerodynamic coefficients for the Lear-Jet and the Augmentor Wing Jet STOL Research Aircraft is reviewed. The coefficients estimated from flight data are compared with values based on large-scale wind-tunnel tests. The results obtained by the regression and quasilinearization identification techniques are also compared. The regression method generally provides the lower standard deviation in the coefficient estimates and provides the better fit to the wind-tunnel values. The addition of nonlinear terms in the aerodynamic equations decreases the difference between the estimated and measured time histories but also increases the standard deviation in the estimated coefficient values.

Wingrove, R. C.↗

Comparison of theoretical predicted longitudinal aerodynamic characteristics with full-scale wind tunnel data on the ATLIT airplane

An analytical method is presented for predicting the lift coefficient, the pitching moment coefficient, and the drag coefficient of light, twin-engine, propeller-driven airplanes. The method was applied to the Advanced Technology Light Twin-Engine airplane. The calculated characteristics were then correlated against full scale wind tunnel data. The analytical method was found to predict the drag and pitching moment fairly well. However, the lift prediction was extremely poor.

Vandam, C. P. G.↗

Shuttle 'Challenger' aerodynamic performance from flight data - Comparisons with predicted values and 'Columbia' experience

Longitudinal aerodynamic performance comparisons between flight extracted and predicted values are presented for the first eight NASA Space Shuttle entry missions. Challenger results are correlated with the ensemble five flight Columbia experience and indicate effects due to differing angle-of-attack and body flap deflection profiles. An Appendix is attached showing the results of each flight using both the LaRC LAIRS and NOAA atmospheres. Discussions are presented which review apparent density anomalies observed in the flight data, with particular emphasis on the suggested shears and turbulence encountered during STS-2 and STS-4. Atmospheres derived from Shuttle data are presented which show structure different than that remotely sensed and imply regions of unstable air masses as a plausible explanation. Though additional aerodynamic investigations are warranted, an added benefit of Shuttle flight data for atmospheric research is discussed, in particular, as applicable to future NASA space vehicles such as AOTVs and tethered satellites.

Findlay, J. T.↗

Space shuttle: A comparison of wind tunnel facility data on the Grumman H-33 delta winged orbiter

A comparison of longitudinal and lateral directional stability and control characteristics of the Phase B Grumman H-33 orbiter configuration obtained from 6 tests conducted in 4 different facilities is presented. The H-33 orbiter configuration does not include drop tanks. Slope data are used as the medium for comparison. The slope data were computed using the SADSAC system and have been reduced to a common reference system. Data used for comparison were selected based on common configurations wherever possible. Where direct configuration comparisons were not possible, the parameters selected for comparison are regarded as insensitive to the noted differences. Factors considered in comparing the various data were scaling effects, balance operating ranges, balance sensitivities and control deflection accuracies. All factors considered, the comparison among data obtained from the various facilities is excellent. The minor differences in stability and control characteristics are well within the accuracy band of preliminary design model construction specifications.

Gyorfi, R. A.↗