Search NASA⌕ Search

SEARCH · Search NASA

Results for “longitudinal impedance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Longitudinal impedance of RHIC

The longitudinal impedance of the two RHIC rings has been measured using the effect of potential well distortion on longitudinal Schottky measurements. For the blue RHIC ring Im(Z/n) = 1.5±0.2Ω. For the yellow ring Im(Z/n) = 5.4±1Ω.

43 PARTICLE ACCELERATORS↗

Measurement and Simulation of the RHIC Abort Kicker Longitudinal Impedance

In face of the new upgrades for RHIC the longitudinal impedance of the machine plays an important role in setting the threshold for instabilities and the efficacy of some systems. In this paper we describe the measurement of the longitudinal impedance of the abort kicker for RHIC as well as computer simulations of the structure. The impedance measurement was done by the S21 wire method covering the frequency range from 9 kHz to 2.5 GHz. We observed a sharp resonance peak around 10 MHz and a broader peak around 20 MHz in both, the real and imaginary part, of the Z/n. These two peaks account for a maximum imaginary longitudinal impedance of j15 Ω, a value an order of magnitude larger than the estimated value of j0.2 Ω, which indicates that the kicker is one of the main sources of longitudinal impedance in the machine. A computer model was constructed for simulations in the CST MWS program. Results for the magnet input and the also the beam impedance are compared to the measurements. A more detail study of the system properties and possible changes to reduce the coupling impedance are presented.

43 PARTICLE ACCELERATORS↗

Measurement and simulation of the RHIC abort kicker longitudinal impedence

In face of the new upgrades for RHIC the longitudinal impedance of the machine plays an important role in setting the threshold for instabilities and the efficacy of some systems. In this paper we describe the measurement of the longitudinal impedance of the abort kicker for RHIC as well as computer simulations of the structure. The impedance measurement was done by the S{sub 21} wire method covering the frequency range from 9 kHz to 2.5 GHz. We observed a sharp resonance peak around 10 MHz and a broader peak around 20 MHz in both, the real and imaginary part, of the Z/n. These two peaks account for a maximum imaginary longitudinal impedance of j15 {Omega}, a value an order of magnitude larger than the estimated value of j0.2 {Omega}, which indicates that the kicker is one of the main sources of longitudinal impedance in the machine. A computer model was constructed for simulations in the CST MWS program. Results for the magnet input and the also the beam impedance are compared to the measurements. A more detail study of the system properties and possible changes to reduce the coupling impedance are presented.

99 GENERAL AND MISCELLANEOUS↗

Improving Longitudinal Impedance of Inductive Inserts

In this article, we discuss methods for improving the longitudinal impedance of inductive inserts used for space charge compensation in the proton storage ring (PSR) at Los Alamos Neutron Science Center (LANSCE) Facility. The PSR relies on inductive inserts to counteract the capacitive impedance produced by the space charge of the proton beam, which can otherwise lead to beam debunching. Existing inductive inserts, which utilize Toshiba M4C21A ferrite, have been effective but require heating to reduce resistive components that can cause instabilities at higher frequencies. This article explores the potential of alternative ferrite materials, specifically National Magnetics C2050, to enhance the performance of these inserts by reducing the need for heating and minimizing resistive impedance. Through both analytical modeling and CST Particle Studio simulations, it is demonstrated that optimized ferrite materials and geometries can significantly improve space charge compensation while mitigating instability risks, ultimately enhancing the performance of the PSR.

43 PARTICLE ACCELERATORS↗

NSLS-II longitudinal impedance budget

From the beginning of the NSLS-II project, the vacuum chamber of the NSLS-II storage ring has been optimized to reduce its impedance. The optimization, performed in close collaboration with the Diagnostic, Vacuum, RF, and Mechanical Engineering groups, has been achieved via calculating the impedance of the vacuum chamber components with the use of both analytical and numerical tools, with the numerical computations carried out with the GdfidL code. Fore reliable NSLS-II operation with the total beam current of 500 mA, each component of the vacuum chamber has been individually optimized to minimize the beam-induced heating and to prevent single-bunch and coupled-bunch instabilities. In this study, the impedance calculation and optimization know-how are summarized for all the chamber components, and the total longitudinal impedance budget is analyzed. As a result of this extensive research and engineering effort, the design beam current of 500 mA has been recently accumulated in NSLS-II without any major problem caused by collective effects.

43 PARTICLE ACCELERATORS↗

Hydrodynamic and Longitudinal Impedance Analysis of Cerebrospinal Fluid Dynamics at the Craniovertebral Junction in Type I Chiari Malformation

Elevated or reduced velocity of cerebrospinal fluid (CSF) at the craniovertebral junction (CVJ) has been associated with type I Chiari malformation (CMI). Thus, quantification of hydrodynamic parameters that describe the CSF dynamics could help assess disease severity and surgical outcome. In this study, we describe the methodology to quantify CSF hydrodynamic parameters near the CVJ and upper cervical spine utilizing subject-specific computational fluid dynamics (CFD) simulations based on in vivo MRI measurements of flow and geometry. Hydrodynamic parameters were computed for a healthy subject and two CMI patients both pre- and post-decompression surgery to determine the differences between cases. For the first time, we present the methods to quantify longitudinal impedance (LI) to CSF motion, a subject-specific hydrodynamic parameter that may have value to help quantify the CSF flow blockage severity in CMI. In addition, the following hydrodynamic parameters were quantified for each case: maximum velocity in systole and diastole, Reynolds and Womersley number, and peak pressure drop during the CSF cardiac flow cycle. The following geometric parameters were quantified: cross-sectional area and hydraulic diameter of the spinal subarachnoid space (SAS). The mean values of the geometric parameters increased post-surgically for the CMI models, but remained smaller than the healthy volunteer. All hydrodynamic parameters, except pressure drop, decreased post-surgically for the CMI patients, but remained greater than in the healthy case. Peak pressure drop alterations were mixed. To our knowledge this study represents the first subject specific CFD simulation of CMI decompression surgery and quantification of LI in the CSF space. Further study in a larger patient and control group is needed to determine if the presented geometric and/or hydrodynamic parameters are helpful for surgical planning.

59 BASIC BIOLOGICAL SCIENCES↗

Matrix solution to longitudinal impedance of multi-layer circular structures

A matrix method in which radial wave propagation is treated in analogy to longitudinal transmission lines is presented and applied to finding the longitudinal coupling impedance of axially symmetric multi-layer beam tubes. The method is demonstrated in the case of a Higher Order Mode ferrite absorber with an inserted coated ceramic beam tube. The screening of the ferrite damping properties by the dielectric beam tube is discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Matrix solution to longitudinal impedance of multi-layer circular structures

This document provides a top‐level description of a superconducting cavity designed to store hadron beams in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory. It refers to more detailed documents covering the various issues in designing, constructing and operating this cavity.

43 PARTICLE ACCELERATORS↗

Improving Longitudinal Impedance of Inductive Inserts

Space charge compensation is essential to keeping the beam inside a ring such as PSR in the desired bunch form. The space charges of the ring will lead to the beam debunching, and the most prominent form of compensation for this is the use of RF to bunch the ring back. It has long been known however, that the impedance presented to the beam by its space charge could be compensated by a passive component. Such a passive component has been in use in PSR since 2000, but upgrading it could greatly improve the capabilities of the PSR. Additionally, the inserts presently used would require updating to match any changes in the beam pipe, both mechanically and to increase the space charge compensation.

43 PARTICLE ACCELERATORS↗

Numerical Study of Three Dimensional Effects in Longitudinal Space-Charge Impedance

Longitudinal space-charge (LSC) effects are generally considered as detrimental in free-electron lasers as they can seed instabilities. Such “microbunching instabilities” were recently shown to be potentially useful to support the generation of broadband coherent radiation pulses [1, 2]. Therefore there has been an increasing interest in devising accelerator beamlines capable of sustaining this LSC instability as a mechanism to produce a coherent light source. To date most of these studies have been carried out with a one-dimensional impedance model for the LSC. In this paper we use a N-body “Barnes-Hut” algorithm [3] to simulate the 3D space charge force in the beam combined with elegant [4] and explore the limitation of the 1D model often used

43 PARTICLE ACCELERATORS↗

Modeling Longitudinal Dynamics in the Fermilab Booster Synchrotron

The PIP-II project will replace the existing 400 MeV linac with a new, CW-capable, 800 MeV superconducting one. With respect to current operations, a 50% increase in beam intensity in the rapid cycling Booster synchrotron is expected. Booster batches are combined in the Recycler ring; this process limits the allowed longitudinal emittance of the extracted Booster beam. To suppress eddy currents, the Booster has no beam pipe; magnets are evacuated, exposing the beam to core laminations and this has a substantial impact on the longitudinal impedance. Noticeable longitudinal emittance growth is already observed at transition crossing. Operation at higher intensity will likely necessitate mitigation measures. We describe systematic efforts to construct a predictive model for current operating conditions. A longitudinal only code including a laminated wall impedance model, space charge effects, and feedback loops is developed. Parameter validation is performed using detailed measurements of relevant beam, rf and control parameters. An attempt is made to benchmark the code at operationally favorable machine settings.

43 PARTICLE ACCELERATORS↗

Numerical Calculations of the Longitudinal and Transverse Impedances in the Step Transitions

In this paper results of the transverse and longitudinal impedance calculations by means of GdfidL code are presented in axially symmetric and rectangular structures. Wakepotentials are calculated up to 10 m with a bunch length of 1.4 mm. Three types of transitions are considered for each geometry; “narrowing” step, “widening” step and ridge transition. Investigation of the longitudinal impedances in rectangular and in axially symmetric geometries were done earlier by H. G. Hereward and S. A. Kheifets. They considered the coupling impedance of the “widening” and the “narrowing” steps.

97 MATHEMATICS AND COMPUTING↗