Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop heat pipes spacecraft thermal control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A comparative analysis of loop heat pipe based thermal architectures for spacecraft thermal control

Loop Heat Pipes (LHP) have gained acceptance as a viable means of heat transport in many spacecraft in recent years. However, applications using LHP technology tend to only remove waste heat from a single component to an external radiator. Removing heat from multiple components has been done by using multiple LHPs. This paper discusses the development and implementation of a Loop Heat Pipe based thermal architecture for spacecraft. In this architecture, a Loop Heat Pipe with multiple evaporators and condensers is described in which heat load sharing and thermal control of multiple components can be achieved. A key element in using a LHP thermal architecture is defining the need for such an architecture early in the spacecraft design process. This paper describes an example in which a LHP based thermal architecture can be used and how such a system can have advantages in weight, cost and reliability over other kinds of distributed thermal control systems. The example used in this paper focuses on a Mars Rover Thermal Architecture. However, the principles described here are applicable to Earth orbiting spacecraft as well.

loop heat pipes↗

Miniature Heat Transport System for Spacecraft Thermal Control

Loop heat pipes (LHP) are efficient devices for heat transfer and use the basic principle of a closed evaporation-condensation cycle. The advantage of using a loop heat pipe over other conventional methods is that large quantities of heat can be transported through a small cross-sectional area over a considerable distance with no additional power input to the system. By using LHPs, it seems possible to meet the growing demand for high-power cooling devices. Although they are somewhat similar to conventional heat pipes, LHPs have a whole set of unique properties, such as low pressure drops and flexible lines between condenser and evaporator, that make them rather promising. LHPs are capable of providing a means of transporting heat over long distances with no input power other than the heat being transported because of the specially designed evaporator and the separation of liquid and vapor lines. For LHP design and fabrication, preliminary analysis on the basis of dimensionless criteria is necessary because of certain complicated phenomena that take place in the heat pipe. Modeling the performance of the LHP and miniaturizing its size are tasks and objectives of current research. In the course of h s work, the LHP and its components, including the evaporator (the most critical and complex part of the LHP), were modeled with the corresponding dimensionless groups also being investigated. Next, analysis of heat and mass transfer processes in the LHP, selection of the most weighted criteria from known dimensionless groups (thermal-fluid sciences), heat transfer rate limits, (heat pipe theory), and experimental ratios which are unique to a given heat pipe class are discussed. In the third part of the report, two-phase flow heat and mass transfer performances inside the LHP condenser are analyzed and calculated for Earth-normal gravity and microgravity conditions. On the basis of recent models and experimental databanks, an analysis for condensing two-phase flow regimes, pressure gradients, and local heat transfer coefficients using ammonia, propylene, and R134, are carried out.

Ochterbeck, Jay M.↗

Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control

This paper presents the development of the Thermal Loop experiment under NASA's New Millennium Program Space Technology 8 (ST8) Project. The Thermal Loop experiment was originally planned for validating in space an advanced heat transport system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and multiple condensers. Details of the thermal loop concept, technical advances and benefits, Level 1 requirements and the technology validation approach are described. An MLHP breadboard has been built and tested in the laboratory and thermal vacuum environments, and has demonstrated excellent performance that met or exceeded the design requirements. The MLHP retains all features of state-of-the-art loop heat pipes and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. In addition, an analytical model has been developed to simulate the steady state and transient operation of the MHLP, and the model predictions agreed very well with experimental results. A protoflight MLHP has been built and is being tested in a thermal vacuum chamber to validate its performance and technical readiness for a flight experiment.

Ku, Jentung↗

Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control: Validation Results - Part 2

Under NASA s New Millennium Program Space Technology 8 (ST 8) Project, Goddard Space Fight Center has conducted a Thermal Loop experiment to advance the maturity of the Thermal Loop technology from proof of concept to prototype demonstration in a relevant environment , i.e. from a technology readiness level (TRL) of 3 to a level of 6. The thermal Loop is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and multiple condensers designed for future small system applications requiring low mass, low power, and compactness. The MLHP retains all features of state-of-the-art loop heat pipes (LHPs) and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. An MLHP breadboard was built and tested in the laboratory and thermal vacuum environments for the TRL 4 and TRL 5 validations, respectively, and an MLHP proto-flight unit was built and tested in a thermal vacuum chamber for the TRL 6 validation. In addition, an analytical model was developed to simulate the steady state and transient behaviors of the MLHP during various validation tests. The MLHP demonstrated excellent performance during experimental tests and the analytical model predictions agreed very well with experimental data. All success criteria at various TRLs were met. Hence, the Thermal Loop technology has reached a TRL of 6. This paper presents the validation results, both experimental and analytical, of such a technology development effort.

Ku, Jentung↗

Multi-Evaporator Miniature Loop Heat Pipe for Small Spacecraft Thermal Control: New Technologies and Validation Approach - Part 1

Under NASA s New Millennium Program Space Technology 8 (ST 8) Project, four experiments Thermal Loop, Dependable Microprocessor, SAILMAST, and UltraFlex - were conducted to advance the maturity of individual technologies from proof of concept to prototype demonstration in a relevant environment , i.e. from a technology readiness level (TRL) of 3 to a level of 6. This paper presents the new technologies and validation approach of the Thermal Loop experiment. The Thermal Loop is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and multiple condensers designed for future small system applications requiring low mass, low power, and compactness. The MLHP retains all features of state-of-the-art loop heat pipes (LHPs) and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Details of the thermal loop concept, technical advances, benefits, objectives, level 1 requirements, and performance characteristics are described. Also included in the paper are descriptions of the test articles and mathematical modeling used for the technology validation. An MLHP breadboard was built and tested in the laboratory and thermal vacuum environments for TRL 4 and TRL 5 validations, and an MLHP proto-flight unit was built and tested in a thermal vacuum chamber for the TRL 6 validation. In addition, an analytical model was developed to simulate the steady state and transient behaviors of the MLHP during various validation tests. Capabilities and limitations of the analytical model are also addressed.

Ku, Jentung↗

Miniature Loop Heat Pipe with Multiple Evaporators for Thermal Control of Small Spacecraft

This paper presents an advanced miniature heat transport system for thermal control of small spacecraft. The thermal system consists of a loop heat pipe (LHP) with multiple evaporators and multiple deployable radiators for heat transfer, and variable emittance coatings on the radiators for performance enhancement. Thermoelectric coolers are used to control the loop operating temperature. The thermal system combines the functions of variable conductance heat pipes, thermal switches, thermal diodes, and the state-of-the-art LHPs into a single integrated thermal system. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Steady state and transient analytical models have been developed, and scaling criteria have also been established. A breadboard unit has been built for functional testing in laboratory and thermal vacuum environments. Experimental results show excellent performance of the thermal system and correlate very well with theoretical predictions.

Ku, Jentung↗

Loop Heat Pipe Applications for Thermal Control of Martian Landers/Rovers

In early nineties Mars was designated as the planet to be explored. The present results of Mars program include the following: Background of Mars program. Thermal control design for Martian spacecraft. Loop heat pipe for Lander and Rover. Test results. and LHP applications for future Martian Lander and Rover.

Birur, Gaj↗

Capillary Two-Phase Thermal Devices for Space Applications

This is the presentation file for an invited seminar for Department of Mechanical and Aerospace Engineering at the Case Western Reserve University. The seminar is scheduled for April 1, 2016.Description: This presentation will discuss operating principles and performance characteristics of heat pipes (HPs) and loop heat pipes (LHPs) and their application for spacecraft thermal control. Topics include: 1) HP operating principles; 2) HP performance characteristics; 3) LHP pressure profiles; 4) LHP operating temperature; 5) LHP operating temperature control; and 6) Examples of using HPs and LHPs on NASA flight projects.

Thermal Contgrol↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗

Additive Manufacturing and Experimental Characterization of Nickel-Titanium Shape-Memory Alloy Wick Structures and Heat Pipes for Spacecraft Thermal Control

Shape memory alloys (SMA), such as those based on nickel-titanium (NiTi), are increasingly being applied as multifunctional spacecraft components. For thermal management applications, NiTi flow tubing hinges and self-deploying loop heat pipes have been demonstrated. Emerging additive manufacturing (AM) processes are enabling more complex SMA devices than can be formed from conventional plain wire, tubing, and sheet stock materials. This paper presents our progress toward applying powder bed fusion AM to producing porous NiTi wicks and NiTi-H2O heat pipes, which could be embedded in thermally deploying radiators for spacecraft thermal management. AM near-equiatomic NiTi (55.1 wt% Ni) porous wick specimens were produced with a range of deposition parameters. Transient acetone rate-of-rise experiments were performed to estimate wick permeability (K) and average pore radius (r_pore) values and identify parameter sets with high capillary performance. Surface treatments were evaluated to achieve hydrophilic wick structures. Evaluated treatments included chemical oxide growth with H2O2, oxide and sodium titanate growth with NaOH solution, and ultrasonic cleaning with specialty detergents that can remove hydrocarbon contaminants. The most durable hydrophilic surface conditions were obtained with the NaOH treatment. High performing wick deposition parameters were used to produce a full AM NiTi heat pipe, which was treated with NaOH solution to activate the wick. This heat pipe was operated on a test stand in the inverted configuration (upper evaporator and lower condenser), and demonstrated stable nearly isothermal operation for 150 hrs.

Thermal management↗